Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros

Banco de datos
Idioma
Tipo del documento
Publication year range
1.
Herald of Medicine ; (12): 131-136, 2024.
Artículo en Zh | WPRIM | ID: wpr-1023690

RESUMEN

Objective To evaluate the efficacy and safety of tigecycline combined with cefoperazone-sulbactam sodium in the treatment of multi-/extensively-drug resistant Acinetobacter baumannii(MDRAB/XDRAB)associated central nervous system(CNS)infection,and to provide clinical evidence for antibiotic treatment of MDRAB/XDRAB-related intracranial disease.Methods The Wanfang Data Knowledge Service Platform,Chinese Biomedical Literature Database,VIP Chinese Science and Technology Journal Full-text Database,China National Knowledge Infrastructure(CNKI),Pubmed,Embase database,and Cochrane Library were searched to extract the literature of randomized controlled studies on tigecycline and cefoperazone sulbactam in the treatment of MDRAB/XDRAB CNS infection until September 1st,2022.The included studies were assessed for quality using the Cochrane Collaboration Risk of Bias assessment tool,and valid data were extracted and meta-analyzed using RevMan5.4 software.Results A total of 184 articles were screened and 4 Chinese RCTs were finally included,with a sample size of 267 cases.Meta-analysis showed that the overall efficacy of combination therapy for MDRAB/XDRAB CNS infection was better than monotherapy[OR = 4.30,95%CI =(1.93,9.58),P<0.01].Combination therapy had a better bacterial clearance[OR=4.20,95%CI=(2.08,8.48),P<0.01].And combination therapy resulted in a lower incidence of adverse effects[OR= 0.19,95%CI =(0.05,0.67),P<0.05].There was no apparent difference in cure rate between combination therapy and monotherapy(P>0.05).Conclusion Current evidence suggests that tigecycline combined with cefoperazone-sulbactam sodium may have better clinical efficacy and safety than monotherapy for MDRAB/XDRAB CNS infections.Limited by the number and quality of included studies,needs to be verified by more and higher-quality studies.

2.
Chinese Journal of Radiology ; (12): 95-100, 2020.
Artículo en Zh | WPRIM | ID: wpr-868265

RESUMEN

Objective:To investigate the feasibility of one-step coronary and carotid-cerebrovascular computed tomography angiography (CTA) using high-pitch Double Turbo Flash mode and to analyze the image quality and radiation dose in patients with heart rate variability using multi-slice detector dual-source CT.Methods:A total of 79 patients with heart rate variability higher than 3 beat/min (bpm) were retrospectively analyzed. They were grouped by the scanning methods. Group A ( n=40) were performed double turbo flash mode for one-step coronary and carotid-cerebrovascular arteriesinjected with one injection of contrast agent.further divided into Single A (only the phase 1 image)and Double A(combined images of phases 1 and 2). Group B ( n=39) were performed separately with twice injection of contrast agent. Subjective scoring was performed on the image quality of the group Single A, Double A and B using a 4-point. Then the objective parameters of image quality, CT attenuations, image noise, signal-to-noise (SNR), and contrast-to-noise (CNR), were evaluated. Then subjective scores, objective evaluation indicators, and radiation dose were compared with one-way ANOVA analysis among the three groups.Contrast agent were compared by using t test in group A and B. Results:No significant difference was found ( F=2.093, P=0.128) for the subjective scores of the head and neck CTA among the three groups with (3.47±0.51), (3.53±0.51), (3.69±0.47). Significant difference was found ( F=50.955, P<0.01) for the subjective scores of coronary CTA among the three groups with (2.70±0.76), (3.35±0.66), (3.58±0.50), and there was no statistically significant difference between Double A and B groups ( P=0.104), met the requirements for diagnosis. The objective evaluation of the three groups compared the head and neck CTA images were statistically significant ( P<0.05), of which the difference between the Single A and the Double A was not statistically significant ( P>0.05), met the requirements for diagnosis; the differences in SNR and CNR of coronary CTA images are statistically significant ( F=12.991, 12.236, P<0.01), and there was no statistically significant difference between Double A and B ( P>0.05), met the requirements for diagnosis. Radiation dose in the group Double A was lower than group B (decreased by 46.15%, P<0.01).The amount of the contrast agent in the group Double A was lower than group B (decreased by 44.13%, t=-45.455; P<0.01). Conclusion:The double turbo flash mode is feasibility for one-step coronary and carotid-cerebrovascular CTA in patients with the heart rate variability using multi-slice dual-source CT.This scan mode can maintain the diagnostic image quality with low contrast agent and radiation dose.

3.
Chinese Journal of Radiology ; (12): 95-100, 2020.
Artículo en Zh | WPRIM | ID: wpr-799424

RESUMEN

Objective@#To investigate the feasibility of one-step coronary and carotid-cerebrovascular computed tomography angiography (CTA) using high-pitch Double Turbo Flash mode and to analyze the image quality and radiation dose in patients with heart rate variability using multi-slice detector dual-source CT.@*Methods@#A total of 79 patients with heart rate variability higher than 3 beat/min (bpm) were retrospectively analyzed. They were grouped by the scanning methods. Group A (n=40) were performed double turbo flash mode for one-step coronary and carotid-cerebrovascular arteriesinjected with one injection of contrast agent.further divided into Single A (only the phase 1 image)and Double A(combined images of phases 1 and 2). Group B (n=39) were performed separately with twice injection of contrast agent. Subjective scoring was performed on the image quality of the group Single A, Double A and B using a 4-point. Then the objective parameters of image quality, CT attenuations, image noise, signal-to-noise (SNR), and contrast-to-noise (CNR), were evaluated. Then subjective scores, objective evaluation indicators, and radiation dose were compared with one-way ANOVA analysis among the three groups.Contrast agent were compared by using t test in group A and B.@*Results@#No significant difference was found (F=2.093, P=0.128) for the subjective scores of the head and neck CTA among the three groups with (3.47±0.51), (3.53±0.51), (3.69±0.47). Significant difference was found (F=50.955, P<0.01) for the subjective scores of coronary CTA among the three groups with (2.70±0.76), (3.35±0.66), (3.58±0.50), and there was no statistically significant difference between Double A and B groups (P=0.104), met the requirements for diagnosis. The objective evaluation of the three groups compared the head and neck CTA images were statistically significant (P<0.05), of which the difference between the Single A and the Double A was not statistically significant (P>0.05), met the requirements for diagnosis; the differences in SNR and CNR of coronary CTA images are statistically significant (F=12.991, 12.236, P<0.01), and there was no statistically significant difference between Double A and B (P>0.05), met the requirements for diagnosis. Radiation dose in the group Double A was lower than group B (decreased by 46.15%,P<0.01).The amount of the contrast agent in the group Double A was lower than group B (decreased by 44.13%, t=-45.455;P<0.01).@*Conclusion@#The double turbo flash mode is feasibility for one-step coronary and carotid-cerebrovascular CTA in patients with the heart rate variability using multi-slice dual-source CT.This scan mode can maintain the diagnostic image quality with low contrast agent and radiation dose.

4.
Chinese Journal of Neurology ; (12): 544-546, 2018.
Artículo en Zh | WPRIM | ID: wpr-710980

RESUMEN

Brevundimonas vesicularis is a rare opportunistic pathogen, which is rare in clinical practice, especially in cases of central nervous system infection. There are no reports in China, and only one case is reported abroad. We analyzed the clinical data of one case of bacterial meningitis caused by Brevundimonas vesicularis in our department, in order to improve the understanding of the disease.

5.
Artículo en Zh | WPRIM | ID: wpr-953789

RESUMEN

@#Soldiers are a group whose mental level are significantly low when special tasks in military exercises and actual combat training and other military stress. And one of main reasons caused in combat effectiveness reducing or potential non-combat loss is psychological and physiological and pathological damage which caused by military stress. This article reviewed the research about psychological stress reaction under military stress in the past years.

SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda