Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Publication year range
1.
J Taibah Univ Med Sci ; 18(6): 1599-1607, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37711760

RESUMEN

Objectives: To determine the diagnostic performance and influencing factors of 128-slice coronary computed tomography angiography (CCTA) compared with invasive coronary angiography (ICA) in patients with suspected coronary artery disease (CAD). Methods: A cross-sectional analysis study enrolled 139 patients suspected of having CAD, who underwent and received a 128-slice CCTA and ICA. Results: The patient-based model showed high sensitivity and a positive predictive value of 93.2% and 95.3%, respectively (for stenosis ≥50%). However, these values were lower when analyzed using vessel-based (85.6% and 81.1%) and segment-based (73.9% and 66.6%) models. Specificity and negative predictive value were highest in the segment-based model, decreasing in vessel- and patient-based models at 96.4% and 95.4%, 90.5% and 90.0%, and 36.4% and 42.1%, respectively (for stenosis ≥70%). All diagnostic values were reduced when the calcium score was ≥400 Agatston units. Conclusion: 128-slice CCTA is an optimal, minimally invasive, and high-performance method to diagnose the stenosis and morphology of coronary artery lesions. The diagnostic performance of 128-slice CCTA is very high. Heart rate and body mass index do not affect diagnostic accuracy, whereas a calcium score ≥400 Agatston units is a factor that causes a decrease in diagnostic performance.

2.
Wellcome Open Res ; 4: 143, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31681857

RESUMEN

The number of controlled human infection models (CHIMs) conducted worldwide has increased considerably in recent years, although few have been conducted in low and middle-income countries (LMICs), where infectious diseases have the greatest burden. Recently Oxford University Clinical Research Unit (OUCRU) in Ho Chi Minh City (HCMC) started developing CHIM research proposals motivated by the need to develop a clearer and more grounded understanding of the issues surrounding the conduct of CHIMs in LMICs. To explore initial perceptions and barriers to conducting CHIMs in Vietnam, OUCRU researchers conducted a set of key stakeholder interviews early in 2018 and held a CHIM workshop in HCMC in March 2018. This paper summarizes the discussions from the workshop and outlines a way forward for conducting CHIMs in Vietnam.

SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda