Clin Oral Investig ; 23(3): 1121-1132, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29959598

RESUMEN

OBJECTIVES: Due to severe limitations of dental pulp sensitivity tests, the direct recording of pulsed blood flow, using photoplethysmography (PPG), has been proposed. In vivo evaluation is methodologically difficult and in vitro models have hitherto been adversely influenced by shortcomings in emulating the in vivo situation. Consequently, the aim of this study was to test an improved data acquisition system and to use this configuration for recording pulsed blood in a new model. MATERIALS AND METHODS: We introduced a PPG signal detection system by recording signals under different blood flow conditions at two wavelengths (625 and 940 nm). Pulsed blood flow signals were measured using an in vitro model, containing a molar with a glass pulp and a resin socket, which closely resembled in vivo conditions with regard to volumetric blood flow, pulp anatomy, and surrounding tissue. RESULTS: The detection system showed improved signal strength without stronger blanketing of noise. On the tooth surface, it was possible to detect signals emanating from pulsed blood flow from the glass pulp and from surrounding tissue at 625 nm. At 940 nm, pulp derived signals were recorded, without interference signals from surrounding tissue. CONCLUSION: The PPG-based method has the potential to detect pulsed blood flow in small volumes in the pulp and (at 625 nm) also in adjacent tissues. CLINICAL RELEVANCE: The results show the need for clear differentiation of the spatial origins of blood flow signals of any vitality test method to be applied to teeth.


Asunto(s)
Cavidad Pulpar , Prueba de la Pulpa Dental , Pulpa Dental , Flujometría por Láser-Doppler , Diente Molar
2.
Stud Health Technol Inform ; 94: 144-50, 2003.
Artículo en Inglés | MEDLINE | ID: mdl-15455880

RESUMEN

Mechanical properties of biological tissue represent important diagnostic information and are of histological relevance (hard lesions, "nodes" in organs: tumors; calcifications in vessels: arteriosclerosis). The problem is, that such information is usually obtained by digital palpation only, which is limited with respect to sensitivity. It requires intuitive assessment and does not allow quantitative documentation. A suitable sensor is required for quantitative detection of mechanical tissue properties. On the other hand, there is also some need for a realistic mechanical display of those tissue properties. Suitable actuator arrays with high spatial resolution and real-time capabilities are required operating in a haptic sensor actuator system with different applications. The sensor system uses real time ultrasonic elastography whereas the tactile actuator is based on electrorheological fluids. Due to their small size the actuator array elements have to be manufactured by micro-mechanical production methods. In order to supply the actuator elements with individual high voltages a sophisticated switching and control concept have been designed. This haptic system has the potential of inducing real time substantial forces, using a compact lightweight mechanism which can be applied to numerous areas including intraoperative navigation, telemedicine, teaching, space and telecommunication.


Asunto(s)
Simulación por Computador , Elasticidad , Alemania , Humanos , Reología , Interfaz Usuario-Computador