RESUMEN
AIMS: We hypothesized that amiodarone (AM), unlike d-sotalol (DS) (a 'pure' Class III agent), not only prolongs the action potential duration (APD) but also causes post-repolarization refractoriness (PRR), thereby preventing premature excitation and providing superior antiarrhythmic efficacy. METHODS AND RESULTS: We tested this hypothesis in 31 patients with inducible ventricular tachycardia (VT) during programmed stimulation with the use of the 'Franz' monophasic action potential (MAP) catheter with simultaneous pacing capability. We determined the effective refractory period (ERP) for each of three extrastimuli (S2-S4) and the corresponding MAP duration at 90% repolarization (APD90), both during baseline and on randomized therapy with either DS (n = 15) or AM (n = 16). We defined ERP > APD90 as PRR and ERP < APD90 as 'encroachment' on repolarization. A revised computer action potential model was developed to help explain the mechanisms of these in-vivo human-heart phenomena. Encroachment but not PRR was present in all patients at baseline and during DS treatment (NS vs. baseline), and VT was non-inducible in only 2 of 15 DS patients. In contrast, in 12 of 16 AM patients PRR was present (P < 0.001 vs. baseline), and VT was no longer inducible. Our model (with revised sodium channel kinetics) reproduced encroachment and drug-induced PRR. CONCLUSION: Both, AM and DS, prolonged APD90 but only AM produced PRR and prevented encroachment of premature extrastimuli. Our computer simulations suggest that PRR is due to altered kinetics of the slow inactivation of the rapid sodium current. This may contribute to the high antiarrhythmic efficacy of AM.
Asunto(s)
Amiodarona/uso terapéutico , Antiarrítmicos/uso terapéutico , Sistema de Conducción Cardíaco/efectos de los fármacos , Frecuencia Cardíaca/efectos de los fármacos , Periodo Refractario Electrofisiológico/efectos de los fármacos , Bloqueadores de los Canales de Sodio/uso terapéutico , Canales de Sodio/efectos de los fármacos , Sotalol/uso terapéutico , Taquicardia Ventricular/tratamiento farmacológico , Potenciales de Acción , Anciano , Anciano de 80 o más Años , Estimulación Cardíaca Artificial , Simulación por Computador , Técnicas Electrofisiológicas Cardíacas , Femenino , Sistema de Conducción Cardíaco/metabolismo , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Modelos Cardiovasculares , Análisis Numérico Asistido por Computador , Valor Predictivo de las Pruebas , Estudios Prospectivos , Sodio/metabolismo , Canales de Sodio/metabolismo , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/metabolismo , Taquicardia Ventricular/fisiopatología , Factores de Tiempo , Resultado del TratamientoRESUMEN
BACKGROUND: The complex relationship between heart failure and atrial tachyarrhythmias (AT/atrial fibrillation [AF]) is not well understood. We examined the temporal association between changes in intrathoracic impedance, suggesting thoracic fluid accumulation, and AT/AF occurrence in cardiac resynchronization therapy-defibrillator and implantable cardioverter defibrillator (ICD) patients. METHODS: A retrospective analysis was conducted on stored implantable device data to identify patients with automatic monitoring of daily AT/AF burden and intrathoracic impedance. Daily population trends in AT/AF burden before and after a fluid index threshold crossing (FIC) were determined. RESULTS: A total of 73,018 patients (68 ± 12 years, 51% ICD, 75% male) were evaluated over 18.6 ± 11.5 months. Kaplan-Meier analysis indicated a significantly higher probability of FIC events in the first month following the onset of persistent AT/AF when compared to a matched group without persistent AT/AF (hazard ratio [HR] 1.65, 95% confidence interval [CI] [1.58, 1.72], P < 0.001). Conversely, patients were significantly more likely to experience an episode of persistent AF in the first month after the FIC event (HR 1.32, 95% CI [1.08, 1.63], P = 0.008). The probability of a fluid index crossing within 30 days of the onset of persistent AT/AF was significantly lower in a subgroup of patients with adequate rate control (35.8% [34.3-37.4%] vs 42.0% [39.6-44.6%]; HR 1.24 [1.13-1.36]). CONCLUSION: Thoracic fluid accumulation, as indicated by decreasing intrathoracic impedance, was more likely to occur immediately after the onset of persistent AT/AF, especially in the presence of inadequate rate control. Likewise, the onset of persistent AT/AF was more likely following a decrease in intrathoracic impedance.
Asunto(s)
Fibrilación Atrial/epidemiología , Fibrilación Atrial/prevención & control , Dispositivos de Terapia de Resincronización Cardíaca/estadística & datos numéricos , Desfibriladores Implantables/estadística & datos numéricos , Derrame Pleural/diagnóstico , Derrame Pleural/epidemiología , Anciano , Cardiografía de Impedancia/estadística & datos numéricos , Causalidad , Comorbilidad , Femenino , Insuficiencia Cardíaca , Humanos , Incidencia , Masculino , Reproducibilidad de los Resultados , Estudios Retrospectivos , Factores de Riesgo , Sensibilidad y Especificidad , Estados Unidos/epidemiologíaRESUMEN
BACKGROUND: The Heart Rhythm Society strongly recommends remote monitoring (RM) of cardiovascular implantable electronic devices (CIEDs) because of the clinical outcome benefits to patients. However, many patients do not adhere to RM and, thus, do not achieve these benefits. There has been limited study of patient-level barriers and facilitators to RM adherence; understanding patient perspectives is essential to developing solutions to improve adherence. OBJECTIVE: We sought to identify barriers and facilitators associated with adherence to RM among veterans with CIEDs followed by the Veterans Health Administration. METHODS: We interviewed 40 veterans with CIEDs regarding their experiences with RM. Veterans were stratified into 3 groups based on their adherence to scheduled RM transmissions over the past 2 years: 6 fully adherent (≥95%), 25 partially adherent (≥65% but <95%), and 9 nonadherent (<65%). As the focus was to understand challenges with RM adherence, partially adherent and nonadherent veterans were preferentially weighted for selection. Veterans were mailed a letter stating they would be called to understand their experiences and perspectives of RM and possible barriers, and then contacted beginning 1 week after the letter was mailed. Interviews were structured (some questions allowing for open-ended responses to dive deeper into themes) and focused on 4 predetermined domains: knowledge of RM, satisfaction with RM, reasons for nonadherence, and preferences for health care engagement. RESULTS: Of the 44 veterans contacted, 40 (91%) agreed to participate. The mean veteran age was 75.3 (SD 7.6) years, and 98% (39/40) were men. Veterans had been implanted with their current CIED for an average of 4.4 (SD 2.8) years. A total of 58% (23/40) of veterans recalled a discussion of home monitoring, and 45% (18/40) reported a good understanding of RM; however, when asked to describe RM, their understanding was sometimes incomplete or not correct. Among the 31 fully or partially adherent veterans, nearly all were satisfied with RM. Approximately one-third recalled ever being told the results of a remote transmission. Among partially or nonadherent veterans, only one-fourth reported being contacted by a Department of Veterans Affairs health care professional regarding not having sent a remote transmission; among those who had troubleshooted to ensure they could send remote transmissions, they often relied on the CIED manufacturer for help (this experience was nearly always positive). Most nonadherent veterans felt more comfortable engaging in RM if they received more information or education. Most veterans were interested in being notified of a successful remote transmission and learning the results of their remote transmissions. CONCLUSIONS: Veterans with CIEDs often had limited knowledge about RM and did not recall being contacted about nonadherence. When they were contacted and troubleshooted, the experience was positive. These findings provide opportunities to optimize strategies for educating and engaging patients in RM.
RESUMEN
BACKGROUND: Implantable cardioverter-defibrillators (ICDs) improve outcomes in patients with heart failure (HF) with left ventricular ejection fraction (LVEF) ≤35%. Less is known about whether outcomes varied between the 2 noninvasive imaging modalities used to estimate LVEF-2-dimensional echocardiography (2DE) and multigated acquisition radionuclide ventriculography (MUGA)-which use different principles (geometric vs count-based, respectively). OBJECTIVE: The purpose of this study was to examine whether the effect of ICD on mortality in patients with HF and LVEF ≤35% varied on the basis of LVEF measured by 2DE or MUGA. METHODS: Of the 2521 patients with HF with LVEF ≤35% in the Sudden Cardiac Death in Heart Failure Trial, 1676 (66%) were randomized to either placebo or ICD, of whom 1386 (83%) had LVEF measured by 2DE (n = 971) or MUGA (n = 415). Hazard ratios (HRs) and 97.5% confidence intervals (CIs) for mortality associated with ICD were estimated overall, checking for interaction, and within the 2 imaging subgroups. RESULTS: Of the 1386 patients in the present analysis, all-cause mortality occurred in 23.1% (160 of 692) and 29.7% (206 of 694) of patients randomized to ICD or placebo, respectively (HR 0.77; 97.5% CI 0.61-0.97), which is consistent with that in 1676 patients in the original report. HRs (97.5% CIs) for all-cause mortality in the 2DE and MUGA subgroups were 0.79 (0.60-1.04) and 0.72 (0.46-1.11), respectively (P = .693 for interaction). Similar associations were observed for cardiac and arrhythmic mortalities. CONCLUSION: We found no evidence that in patients with HF and LVEF ≤35%, the effect of ICD on mortality varied by the noninvasive imaging method used to measure LVEF.
Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Función Ventricular Izquierda , Volumen Sistólico , Desfibriladores Implantables/efectos adversos , Modelos de Riesgos Proporcionales , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/terapiaRESUMEN
OBJECTIVE: Recent evidence suggests that hydroxychloroquine use is not associated with higher 1-year risk of long QT syndrome (LQTS) in patients with rheumatoid arthritis (RA). Less is known about its long-term risk, the examination of which was the objective of this study. METHODS: We conducted a propensity score-matched active-comparator safety study of hydroxychloroquine in 8,852 veterans (mean age 64 ± 12 years, 14% women, 28% Black) with newly diagnosed RA. A total of 4,426 patients started on hydroxychloroquine and 4,426 started on another nonbiologic disease-modifying antirheumatic drug (DMARD) and were balanced on 87 baseline characteristics. The primary outcome was LQTS during 19-year follow-up through December 31, 2019. RESULTS: Incident LQTS occurred in 4 (0.09%) and 5 (0.11%) patients in the hydroxychloroquine and other DMARD groups, respectively, during the first 2 years. Respective 5-year incidences were 17 (0.38%) and 6 (0.14%), representing 11 additional LQTS events in the hydroxychloroquine group (number needed to harm 403; [95% confidence interval (95% CI)], 217-1,740) and a 181% greater relative risk (95% CI 11%-613%; P = 0.030). Although overall 10-year risk remained significant (hazard ratio 2.17; 95% CI 1.13-4.18), only 5 extra LQTS occurred in hydroxychloroquine group over the next 5 years (years 6-10) and 1 over the next 9 years (years 11-19). There was no association with arrhythmia-related hospitalization or all-cause mortality. CONCLUSIONS: Hydroxychloroquine use had no association with LQTS during the first 2 years after initiation of therapy. There was a higher risk thereafter that became significant after 5 years of therapy. However, the 5-year absolute risk was very low, and the absolute risk difference was even lower. Both risks attenuated during longer follow-up. These findings provide evidence for long-term safety of hydroxychloroquine in patients with RA.
Asunto(s)
Antirreumáticos , Artritis Reumatoide , Síndrome de QT Prolongado , Veteranos , Humanos , Femenino , Persona de Mediana Edad , Anciano , Masculino , Hidroxicloroquina/efectos adversos , Estudios de Cohortes , Estudios de Seguimiento , Estudios Retrospectivos , Artritis Reumatoide/diagnóstico , Artritis Reumatoide/tratamiento farmacológico , Artritis Reumatoide/epidemiología , Antirreumáticos/efectos adversos , Síndrome de QT Prolongado/inducido químicamente , Síndrome de QT Prolongado/diagnóstico , Síndrome de QT Prolongado/epidemiología , Metotrexato/uso terapéuticoRESUMEN
OBJECTIVE: Hydroxychloroquine (HCQ) may prolong the QT interval, a risk factor for torsade de pointes, a potentially fatal ventricular arrhythmia. This study was undertaken to examine the cardiovascular safety of HCQ in patients with rheumatoid arthritis (RA). METHODS: We conducted an active comparator safety study of HCQ in a propensity score-matched cohort of 8,852 US veterans newly diagnosed as having RA between October 1, 2001 and December 31, 2017. Patients were started on HCQ (n = 4,426) or another nonbiologic disease-modifying antirheumatic drug (DMARD; n = 4,426) after RA diagnosis, up to December 31, 2018, and followed up for 12 months after therapy initiation, up to December 31, 2019. RESULTS: Patients had a mean ± SD age of 64 ± 12 years, 14% were women, and 28% were African American. The treatment groups were balanced with regard to 87 baseline characteristics. There were 3 long QT syndrome events (0.03%), 2 of which occurred in patients receiving HCQ. Of the 56 arrhythmia-related hospitalizations (0.63%), 30 occurred in patients in the HCQ group (hazard ratio [HR] associated with HCQ 1.16 [95% confidence interval (95% CI) 0.68-1.95]). All-cause mortality occurred in 144 (3.25%) and 136 (3.07%) of the patients in the HCQ and non-HCQ groups, respectively (HR associated with HCQ 1.06 [95% CI, 0.84-1.34]). During the first 30 days of follow-up, there were no long QT syndrome events, 2 arrhythmia-related hospitalizations (none in the HCQ group), and 13 deaths (6 in the HCQ group). CONCLUSION: Our findings indicate that the incidence of long QT syndrome and arrhythmia-related hospitalization is low in patients with RA during the first year after the initiation of HCQ or another nonbiologic DMARD. We found no evidence that HCQ therapy is associated with a higher risk of adverse cardiovascular events or death.
Asunto(s)
Antirreumáticos/efectos adversos , Arritmias Cardíacas/epidemiología , Artritis Reumatoide/tratamiento farmacológico , Hidroxicloroquina/efectos adversos , Síndrome de QT Prolongado/epidemiología , Anciano , Antirreumáticos/uso terapéutico , Arritmias Cardíacas/inducido químicamente , Femenino , Humanos , Hidroxicloroquina/uso terapéutico , Incidencia , Síndrome de QT Prolongado/inducido químicamente , Masculino , Persona de Mediana Edad , Estados Unidos , VeteranosRESUMEN
BACKGROUND: Heart failure is associated with ventricular tachyarrhythmias (VT/VF). Fluid accumulation during worsened heart failure may trigger VT/VF. Increased intrathoracic impedance has been correlated with fluid accumulation during heart failure. Implanted defibrillators capable of daily measures of intrathoracic impedance allow correlation of impedance with occurrence of VT/VF. We hypothesized that VT/VF episodes are preceded by decreases in intrathoracic impedance. The goal was to identify the relationship of intrathoracic impedance measured by implanted cardioverter defibrillators to the occurrence of VT/VF. METHOD: Implanted defibrillator follow-up data were obtained retrospectively. Those with Medtronic OptiVol (Medtronic Inc., Minneapolis, MN, USA), storing averaged daily and reference impedance values, were reviewed for VT/VF episodes. Impedance changes in the week leading up to VT/VF were analyzed. RESULTS: A total of 317 VT/VF episodes in a cohort of 121 patients' follow-up data were evaluated. Averaged daily intrathoracic impedance declined preceding 64% of VT/VF episodes, with an average decline of 0.46 +/- 0.35 Ohms from the day before the VT/VF episodes. However, the mean values of the averaged daily and reference impedance did not change significantly. A novel measure, DeltaTI, the sum of the daily differences between the averaged daily and reference impedance, was negative preceding 66% of VT/VF episodes (P < 0.001). The mean DeltaTI was -4.0 +/- 1.3 Ohms, which was significantly lower than the theoretically expected value of zero Ohms (P < 0.01). CONCLUSION: (1) Averaged daily impedance declined preceding 64% of VT/VF episodes, but the overall decline was of small magnitude; (2) a novel measure, DeltaTI, was negative preceding 66% of VT/VF episodes, and significantly below zero.
Asunto(s)
Cardiografía de Impedancia , Desfibriladores Implantables , Taquicardia Ventricular/fisiopatología , Anciano , Anciano de 80 o más Años , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/etiología , Humanos , Masculino , Persona de Mediana Edad , Taquicardia Ventricular/complicaciones , Taquicardia Ventricular/terapia , Fibrilación Ventricular/fisiopatología , Fibrilación Ventricular/terapiaRESUMEN
BACKGROUND: Defibrillator implanters have adopted different approaches to managing failures of multicomponent implanted cardioverter defibrillator (ICD) leads. Although recent publications identified single-component failures as common mechanisms of failure, there are no published data regarding how best to manage these failures. METHODS: An internet-based survey was conducted to identify current management strategies. Questions were asked regarding isolated failure of a high-voltage coil or of a pace/sense electrode, in order to identify the frequency of various techniques to correct these failures. RESULTS: A worldwide query collected strategies from 376 physicians identifying themselves as ICD-implanting physicians. Replies came from 28 countries, with the USA accounting for 83.2%. The survey was completed by 85.6% of respondents. Implant experience was >10 years for 61.1%, 3-10 years for 29.1%, and <3 years for 10.4%. When the right ventricular coil failed, 52% abandoned and 48% explanted the failed lead. In superior vena cava coil failure, 61.2% chose to simply exclude this coil, using the other intact lead components. For pace/sense defects, 53.1% chose to implant a new pace/sense lead or switch sensing electrodes, using the intact lead components. Medical literature (76.1%), personal experience (67.6%), and professional guidelines (63.7%) were strong decision-making influences. CONCLUSIONS: (1) Management decisions for single-component failures of ICD leads are complex; (2) Significant differences in management strategy exist among physicians; (3) Medical literature and professional guidelines are strong influences for these decisions; (4) A lead failure registry could help identify reasons for such differences and help guide management.
Asunto(s)
Desfibriladores Implantables/estadística & datos numéricos , Remoción de Dispositivos/estadística & datos numéricos , Electrodos Implantados/estadística & datos numéricos , Análisis de Falla de Equipo/métodos , Análisis de Falla de Equipo/estadística & datos numéricos , Falla de Equipo/estadística & datos numéricos , Pautas de la Práctica en Medicina/estadística & datos numéricos , Recolección de Datos , Humanos , InternacionalidadRESUMEN
BACKGROUND: Acute decompensated heart failure (HF) is the leading cause for hospital readmission. Large-scale sustainable interventions to reduce readmission rate have not been fully explored or proven effective. OBJECTIVE: We studied the impact of hospice and palliative care service utilization on 30-day all-cause hospital readmissions for patients with HF. METHODS AND RESULTS: Data were retrieved from the Department of Veterans Affairs Corporate Data Warehouse. The study included 238 116 HF admissions with primary diagnosis of HF belonging to 130 812 patients. Among these patients, 2592 had hospice and palliative care utilizations and 68 245 patients did not. Rehospitalization was calculated within 30 days of index hospitalization. Propensity scores were used to match hospice and nonhospice patients on demographics, Charlson comorbidity categories, and 30-day survival. In the matched group, logistic regression was used to estimate effects of hospice on readmission, controlling for any covariates that had failed to balance. The average age of the matched patients was 74 years old, 14% were African American, 75% Caucasian, 2% Asian, and 17% female. After propensity matching, the odds ratio for readmission was 1.29. The 95% confidence interval for the odds was 1.13 to 1.48, suggesting that veterans receiving services have a higher chance of readmission. CONCLUSION: In a large cohort study of older US Veterans, utilization of hospice and palliative care services was associated with a higher 30-day all-cause readmission rate among hospitalized patients with HF. Further prospective studies should be conducted to confirm results and test generalizability outside the Veterans Affairs system of care.
Asunto(s)
Insuficiencia Cardíaca/enfermería , Cuidados Paliativos al Final de la Vida/estadística & datos numéricos , Hospitalización/estadística & datos numéricos , Cuidados Paliativos/estadística & datos numéricos , Alta del Paciente/estadística & datos numéricos , Readmisión del Paciente/estadística & datos numéricos , Veteranos/estadística & datos numéricos , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Estados UnidosRESUMEN
BACKGROUND: Age is the strongest predictor of atrial fibrillation (AF), yet little is known about AF incidence in the oldest old. HYPOTHESIS: AF incidence declines after age 90 years, and morbidity is compressed into a brief period at the end of life. METHODS: In this retrospective, longitudinal cohort study of patients (born 1905-1935), we examined cumulative lifetime incidence of AF and its impact on mortality. Data included records from 1 062 610 octogenarians, 317 161 nonagenarians, and 3572 centenarians. Kaplan-Meier curves were used to estimate cumulative incidence of AF by age group, incidence rates were compared using log-rank tests, and Cox proportional hazards model was used to estimate unadjusted hazard ratios. The primary outcome was AF incidence at age > 80 years; the secondary outcome was mortality. RESULTS: The cumulative AF incidence rate was 5.0% in octogenarians, 5.4% in nonagenarians, and 2.3% in centenarians. Octogenarians and nonagenarians had a higher risk of AF incidence compared to centenarians (adjusted hazard ratio 8.74, 95% confidence interval [CI]: 6.31-12.04; and 2.98, 95% CI: 2.17-4.1, respectively). The lowest hazard ratio for mortality in patients with AF compared to those without was 2.3 (95% CI: 2.3-2.4) in patients who were on antiplatelet and anticoagulant medication and had a score of 0 on the Elixhauser comorbidity index score. CONCLUSIONS: Although AF incidence increased with age, being a centenarian was associated with reduced incidence and compression of morbidity. Patients with AF had a higher adjusted mortality rate. However, data suggest that a regimen of anticoagulants and antiplatelets may reduce risk of mortality in patients over 80 with an AF diagnosis.
Asunto(s)
Envejecimiento , Fibrilación Atrial/mortalidad , Factores de Edad , Anciano , Anciano de 80 o más Años , Anticoagulantes/uso terapéutico , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/fisiopatología , Femenino , Humanos , Incidencia , Estimación de Kaplan-Meier , Estudios Longitudinales , Masculino , Inhibidores de Agregación Plaquetaria/uso terapéutico , Pronóstico , Modelos de Riesgos Proporcionales , Factores Protectores , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Estados Unidos/epidemiología , United States Department of Veterans Affairs , Salud de los VeteranosRESUMEN
Bridging basic and clinical electrophysiology has been facilitated by monophasic action potential recordings. The electrocardiogram is a useful clinical approach in detecting abnormal repolarization, but falls short in depicting local repolarization details. The MAP waveform is a reflection of local transmembrane action potentials. We hope to convey a basic understanding of monophasic action potential recording and highlight the clinical utility in both ventricular and atrial arrhythmias.
Asunto(s)
Potenciales de Acción/fisiología , Mapeo del Potencial de Superficie Corporal/métodos , Electrocardiografía/métodos , HumanosRESUMEN
OBJECTIVES: To assess the incidence of chronic illness and its effect on veteran centenarians. DESIGN: Retrospective longitudinal cohort study. SETTING: United States Veterans Affairs Corporate Data Warehouse (CDW). PARTICIPANTS: Community-dwelling veterans born between 1910 and 1915 who survived to at least age 80 (N = 86,892; 31,121 octogenarians, 52,420 nonagenarians, 3,351 centenarians). MEASUREMENTS: The Kaplan-Meier method was used to estimate cumulative incidence of chronic conditions according to age group. Incidence rates were compared using the log-rank test. Cox proportional hazards models were used to estimate unadjusted hazard ratios. RESULTS: Ninety-seven percent of Centenarians were male, 88.0% were white, 31.8% were widowed, 87.5% served in World War II, and 63.9% did not have a service-related disability. The incidence rates of chronic illnesses were higher in octogenarians than centenarians (atrial fibrillation, 15.0% vs 0.6%, P < .001; heart failure, 19.3% vs 0.4%, P < .001; chronic obstructive pulmonary disease, 17.9% vs 0.6%, P < .001; hypertension, 29.6% vs 3.0%, P < .001; end-stage renal disease, 7.2% vs 0.1%, P < .001; malignancy, 14.1% vs 0.6%, P < .001; diabetes mellitus, 11.1% vs 0.4%, P < .001; stroke, 4.6% vs 0.4%, P < .001) and in nonagenarians than centenarians (atrial fibrillation, 13.2% vs 3.5%, P < .001; heart failure, 15.8% vs 3.3%, P < .001; chronic obstructive pulmonary disease, 11.8% vs 3.5%, P < .001; hypertension, 27.2% vs 12.8%, P < .001; end-stage renal disease, 11.9% vs 4.5%, P < .001; malignancy, 8.6% vs 2.3%, P < .001; diabetes mellitus, 7.5% vs 2.2%, P < .001; and stroke, 3.5% vs 1.3%, P < .001). CONCLUSION: In a large cohort of predominantly male community-dwelling elderly veterans, centenarians had a lower incidence of chronic illness than those in their 80s and 90s, demonstrating similar compression of morbidity and extension of health span observed in other studies.
Asunto(s)
Enfermedad Crónica/epidemiología , Vida Independiente , Veteranos/estadística & datos numéricos , Factores de Edad , Anciano de 80 o más Años , Bases de Datos Factuales , Femenino , Insuficiencia Cardíaca/epidemiología , Humanos , Hipertensión/epidemiología , Incidencia , Estudios Longitudinales , Masculino , Morbilidad , Enfermedad Pulmonar Obstructiva Crónica/epidemiología , Estudios Retrospectivos , Estados UnidosRESUMEN
BACKGROUND: In the Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT), a significant fraction of the patients with congestive heart failure ultimately did not die suddenly of arrhythmic causes. Patients with CHF will benefit from better tools to identify if implantable cardioverter-defibrillator (ICD) therapy is needed. OBJECTIVES: We aimed to identify predictor variables from baseline SCD-HeFT patients' R-R intervals that correlate to arrhythmic sudden cardiac death (SCD) and mortality and to design an ICD therapy screening test. METHODS: Ten predictor variables were extracted from prerandomization Holter data from 475 patients enrolled in the ICD arm of the SCD-HeFT by using novel and traditional heart rate variability methods. All variables were correlated to SCD using the Mann-Whitney-Wilcoxon test and receiver operating characteristic analysis. ICD therapy screening tests were designed by minimizing the cost of false classifications. Survival analysis, including log-rank test and Cox models, was also performed. RESULTS: A short-term fractal exponent, α1, and a long-term fractal exponent, α2, from detrended fluctuation analysis, the ratio of low- to high-frequency power, the number of premature ventricular contractions per hour, and the heart rate turbulence slope are all statistically significant for predicting the occurrences of SCD (P < .001) and survival (log-rank, P < .01). The most powerful multivariate predictor tool using the Cox proportional hazards regression model was α2 with a hazard ratio of 0.0465 (95% confidence interval 0.00528-0.409; P < .01). CONCLUSION: Predictor variables extracted from R-R intervals correlate to the occurrences of SCD and distinguish survival functions among patients with ICDs in SCD-HeFT. We believe that SCD prediction models should incorporate Holter-based R-R interval analysis to refine ICD patient selection, especially to exclude patients who are unlikely to benefit from ICD therapy.
Asunto(s)
Amiodarona/uso terapéutico , Arritmias Cardíacas/complicaciones , Muerte Súbita Cardíaca/epidemiología , Electrocardiografía Ambulatoria , Insuficiencia Cardíaca/complicaciones , Frecuencia Cardíaca/fisiología , Medición de Riesgo/métodos , Adulto , Anciano , Anciano de 80 o más Años , Antiarrítmicos/uso terapéutico , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/terapia , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Tasa de Supervivencia/tendencias , Factores de Tiempo , Estados Unidos/epidemiología , Adulto JovenRESUMEN
Despite remarkable advances in design, implantable cardioverter-defibrillator (ICD) leads remain the component most susceptible to failure, which often leads to substantial adverse clinical outcomes. This article focuses on management strategies when ICD lead systems fail. Two cases involving management decisions for ICD lead failures are presented and discussed. One involves a common mode of presentation, inappropriate shocks. The second involves an alert in a patient with a complex system and multiple comorbidities. Although a systematic approach is outlined, management decisions must be balanced by a risk-and-benefit assessment of the individual patient.
RESUMEN
Hypertension refractory to conventional management with medication remains a significant cause of cardiovascular morbidity and mortality. Alternative strategies are warranted in this subgroup of patients. The target of these strategies centers around sympathetic neural activity, which is thought to play a key role in hypertension. We will review the historic and current approaches toward altering sympathetic neural activity, specifically discussing surgical sympathectomy, catheter-based renal denervation strategies, and baroreflex activation therapy.
Asunto(s)
Ablación por Catéter , Hipertensión/cirugía , Riñón/inervación , Simpatectomía/métodos , Ablación por Catéter/instrumentación , Diseño de Equipo , HumanosRESUMEN
Background. Right ventricular pacing (RVP) has been associated with adverse outcomes, including heart failure and death. Minimizing RVP has been proposed as a therapeutic goal for a variety of pacing devices and indications. Objective. Quantify survival according to frequency of RVP in veterans with pacemakers. Methods. We analyzed electrograms from transtelephonic monitoring of veterans implanted with pacemakers between 1995 and 2005 followed by the Eastern Pacemaker Surveillance Center. We compared all cause mortality and time to death between patients with less than 20% and more than 80% RVP. Results. Analysis was limited to the 7198 patients with at least six trans-telephonic monitoring records (mean = 21). Average follow-up was 5.3 years. Average age at pacemaker implant was significantly lower among veterans with <20% RVP (67 years versus 72 years; P < .0001). An equal proportion of deaths during follow-up were noted for each group: 126/565 patients (22%) with <20% RVP and 1113/4968 patients (22%) with >80% RVP. However, average post-implant survival was 4.3 years with <20% RVP versus 4.7 years with >80% RVP (P < .0001). Conclusions. Greater frequency (>80%) of RVP was not associated with higher mortality in this population of veterans. Those veterans utilizing <20% RVP had a shortened adjusted survival rate (P = .0016).