Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 71
Filtrar
1.
Opt Lett ; 46(7): 1514-1517, 2021 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-33793468

RESUMEN

In this work, we theoretically study the transduction of orbital angular momentum (OAM) l for infrared pump lasers into the THz domain. In the case of optical rectification, the transduction of OAM occurs only through a spin-orbit interaction, with the selection rule on the OAM l=0 valid for any kind of polarization of the pump, which means that there is no transfer of OAM along the propagation axis. In difference frequency generation, the selection rule for the difference Δl between the OAM of the pump fields with linear or circular polarization is l=Δl, whereas l ranges from Δl-2 to Δl+2 in cases of both radial and azimuthal polarization. Moreover, for THz generation in the latter case, the high diffraction obtained with tightly focused pumps yields l tending to Δl±2, while l tends to zero in the opposite case of large pump beams.

2.
Zhonghua Fu Chan Ke Za Zhi ; 56(10): 665-670, 2021 Oct 25.
Artículo en Zh | MEDLINE | ID: mdl-34823314

RESUMEN

Objective: To study the cut-off values of urinary microalbumin (mAlb), transferrin (TRF) and α1-microglobulin (α1-MG) during pregnancy in pre-eclampsia (PE) with proteinuria. Methods: A total of 210 pregnant women were enrolled in Renji Hospital from January 2016 to December 2019, including 92 (43.8%) cases of PE pregnant women and 118 (56.2%) cases of normal pregnant women. According to the diagnostic test evaluation method, the positive predictive values, negative predictive values and accuracy of non-pregnant cut-off values of urinary mAlb, TRF and α1-MG for the quantitative determination of 24-hour proteinuria were analyzed. The receiver operating characteristic (ROC) curve was applied to determine the optimal cut-point values of urinary mAlb, TRF and α1-MG during pregnancy. Results: (1) The diagnostic study of non-pregnant adults urinary mAlb, TRF and α1-MG cut-off values for the determination of 24-hour proteinuria value: when urinary mAlb was 30.0 mg/L, TRF was 2.5 mg/L, α1-MG was 12.5 mg/L as the cut-off value, the positive predictive values of the corresponding 24-hour proteinuria value≥ 300 mg were 88.1% (89/101), 88.2% (90/102) and 78.9% (75/95), its negative predictive values were 97.2% (106/109), 98.1% (106/108) and 85.2% (98/115), its diagnostic accuracy were 92.9% (195/210), 93.3% (196/210) and 82.4% (173/210), respectively. As the 24-hour proteinuria value≥ 300 mg was the golden standard, there were significant differences between the diagnostic method of the non-pregnant cut-off value of urinary mAlb, TRF and the golden standard (P<0.05). There was no significant difference between the diagnostic method of the non-pregnant cut-off value of urinary α1-MG and the golden standard (P>0.05). (2) Research on the ROC curve and the optimal cut-point value of urinary mAlb, TRF and α1-MG value: as the 24-hour proteinuria value≥ 300 mg as the criterion, the ROC curve of urinary mAlb, TRF and α1-MG were 0.992, 0.984 and 0.907, respectively. The optimal cut-point values of urinary mAlb, TRF and α1-MG were 86.5 mg/L (Youden index=0.927), 5.5 mg/L (Youden index=0.923), and 15.4 mg/L (Youden index=0.687). (3) The diagnostic study of the optimal cut-point value of urinary mAlb, TRF and α1-MG for the determination of 24-hour proteinuria value: according to the ROC results, when urinary mAlb was 86.5 mg/L, urinary TRF was 5.5 mg/L, and urinary α1-MG was 15.4 mg/L as the cut-off value, the positive predictive values of the corresponding 24-hour proteinuria value≥300 mg were 98.9% (86/87), 95.7% (88/92), 87.7% (71/81), and its negative predictive values were 95.1% (117/123), 96.6% (114/118), 83.7% (108/129), and its accuracy were 96.7% (203/210), 96.2% (202/210), 85.2% (179/210). As the 24-hour proteinuria value≥ 300 mg was the golden standard, there was no significant difference between the diagnostic method of the best cut-off values of urinary mAlb, TRF, α1-MG and the golden standard (P>0.05). Conclusion: It is recommended to define the cut-off values of mAlb, TRF and α1-MG as 86.5 mg/L, 5.5 mg/L and 15.4 mg/L, respectively, during pregnancy.


Asunto(s)
Preeclampsia , Adulto , Femenino , Humanos , Preeclampsia/diagnóstico , Valor Predictivo de las Pruebas , Embarazo , Proteinuria/diagnóstico , Curva ROC , Sensibilidad y Especificidad , Transferrina
3.
Cryo Letters ; 40(6): 322-332, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-33966058

RESUMEN

BACKGROUND: Cryopreservation is a promising plant germplasm preservation technique that provides genetically stable plantlets. OBJECTIVE: To investigate whether the cryopreservation protocol developed for garlic compromises the performance of the cryopreserved plants, compared to garlic plants grown in the field. MATERIALS AND METHODS: The field performance of cryopreserved garlic plantlets under in vivo conditions was compared with garlic derived from the field. We assessed both net photosynthetic rate, bulb characteristics and the efficiency of cryotherapy-induced virus eradication. RESULTS: The superiority of the morphological traits of cryopreserved garlic increased gradually with the growth of the garlic plant. Cryopreservation also improved the net photosynthetic rate, bulb diameter (by 13.4-18.2%), bulb weight (by 37.9-50.5%), and clove number per bulb (by 25.7-63.6%). The highest virus elimination rate due to cryopreservation was 75.0% for onion yellow dwarf virus (OYDV). CONCLUSION: These findings suggest cryopreservation as a promising method for conservation and improvement of garlic.

4.
Genet Mol Res ; 16(1)2017 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-28362995

RESUMEN

MiR-200b, a member of the microRNA-200 family, has been identified to be capable of suppressing glioma cell growth through targeting CREB1 or CD133. However, whether miR-200b affects the biological behavior (proliferation, invasion, and migration) of glioma cells is poorly understood. The aim of this study was to evaluate the effect of miR-200b on the biological behavior of glioma cells in vitro. MiRNA-200b mimics, miRNA-200b inhibitor, and mimic control were transfected into conventionally cultured glioma U251 cells, followed by measuring the expression of miR-200b and CD133 in transfected cells by RT-PCR; effect of miR-200b on CD133 mRNA 3'-UTR luciferase activity by luciferase reporter assay; proliferation activity of transfected U251 cells by MTT method; and changes in U251 cell invasion and migration by Transwell method after transfection. Compared to that in the miRNA-200b inhibitor, mimic control, and blank control groups, miRNA-200b expression was significantly increased and CD133 mRNA expression was significantly decreased in the mimic miRNA-200b group in a time-dependent manner (P < 0.05). Meanwhile, dual luciferase reporter assay showed that miR-200b could inhibit CD133 activity through binding to the 3'-UTR of CD133 mRNA (P < 0.05). Furthermore, the proliferation activity and invasion and migration abilities of U251 cells transfected with miRNA-200b mimic were significantly decreased (P < 0.05). In conclusion, overexpression of miR-200b inhibited the proliferation, invasion, and migration of glioma cells possibly through targeting CD133.


Asunto(s)
Antígeno AC133/genética , Glioma/genética , MicroARNs/genética , Regiones no Traducidas 3' , Antígeno AC133/metabolismo , Apoptosis/genética , Ciclo Celular/genética , Línea Celular Tumoral , Movimiento Celular/genética , Proliferación Celular/genética , Regulación Neoplásica de la Expresión Génica , Glioma/metabolismo , Glioma/patología , Humanos , MicroARNs/biosíntesis , MicroARNs/metabolismo , Neoplasias del Sistema Nervioso/genética , Neoplasias del Sistema Nervioso/metabolismo , Neoplasias del Sistema Nervioso/patología , ARN Mensajero/genética , ARN Mensajero/metabolismo , Transfección
5.
Mymensingh Med J ; 33(2): 544-553, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38557539

RESUMEN

Covid-19 was first detected on 8th March of 2020 in Bangladesh after the global pandemic being started. As a new virus and disease there are scarcity of data of SARS-CoV-2 and Covid-19 respectively in our country. Aim of this study is to assess the demographic characteristics, clinical profiles, underlying co-morbid conditions, treatment pattern and outcome of the SARS-CoV-2 positive patients in Jashore, Bangladesh. This retrospective study recruited 208 RT-PCR positive Covid-19 patients from 1st April 2020 to 15th May 2020 who appeared at Flu corner centre, 250 Bedded General Hospital, Jashore, Bangladesh. Data was collected online through telephone, mobile and email due to the high contagious property of Covid-19. Out of total 208 Covid-19 patients, the mean age of the participants was 37.0±15.0 years with a male and female ratio of 2.06:1. Underlying comorbidities were documented in 36.5% of total Covid-19 patents of which hypertension in 16.3%, diabetes in 14.4%, respiratory diseases in 8.7% and pre-existing coronary arterial diseases in 6.3% patients. Though 17.8% Covid-19 patients were asymptomatic, the most common symptoms were fever (68.8%), cough (30.8%), myalgia (30.8%), sore throat (22.1%), vertigo (21.6%), respiratory distress (20.7%), anorexia (17.8%), nasal congestion (16.3%), nausea or vomiting (13.9%) and diarrhoea (13.0%). Whereas, the symptomatic patients were classified as flu-like illness (77.9%), mild to moderate pneumonia (2.4%) and severe pneumonia (1.9%). Many patients (19.2%) recovered spontaneously and 22.1% patients cured by the only simple symptomatic treatment. The most commonly received antibiotics were Azithromycin and Doxycycline. Home stay management was demonstrated in 73.1% patients, whereas, 26.0% patients required general ward admission and only 0.9% patients required referral for the HDU or ICU management with an average duration of hospital stay of 16±6 days. A high satisfactory outcome was found as evident by complete recovery in 98.08% of Covid-19 patients, complications (0.48%) and fatality (1.44%) even in this secondary care center. Therefore, we can conclude that the disease was well managed with highly satisfactory outcomes even in the low resource health care setting in the early stage of Covid-19 pandemic era. Hence, the early case detection, identification of the high-risk groups and proper management may mitigate to develop complications and fatalities of Covid-19.


Asunto(s)
COVID-19 , Humanos , Masculino , Femenino , Adulto Joven , Adulto , Persona de Mediana Edad , COVID-19/epidemiología , COVID-19/terapia , SARS-CoV-2 , Estudios Retrospectivos , Pandemias , Bangladesh/epidemiología , Atención Secundaria de Salud , Hospitales
7.
Artículo en Zh | MEDLINE | ID: mdl-35610680

RESUMEN

Objective: To explore the feasibility and short-term effect of tensor tympani muscle Tenotomy in the treatment of Meniere's disease under otoscope. The possible pathogenesis was discussed and our views were put forward. Methods: The clinical data of 9 cases of Meniere's disease treated by otoscopic Tenotomy were analyzed retrospectively, including 2 males, 7 females, 5 right ones, 2 left ones and 2 bilateral ones. The average age was (56.33± 10.56) years, ranging from 38 to 75 years. We evaluated intraoperative findings and short-term postoperative efficacy, respectively evaluated postoperative aural fullness, tinnitus and hearing recovery, and evaluated postoperative vertigo attack in a short time. Results: Nine patients were completed the operation under general anaesthesia and otoscopy, and no serious complications occurred. We found new pathological changes in tympanic cavity in some cases during operation. There were rupture of round window membrane in 1 case, severe fibrous hyperplasia near the round window membrane and vestibular window and adhesion with ossicular chain in 1 case, fibrous cord and membranous hyperplasia near vestibular window and round window membrane in 1 case, fibrous hyperplasia and adhesion near the round window membrane in 2 cases, membranous hyperplasia and adhesion around vestibular window in 1 case. No fibrous hyperplasia was found in 3 cases in the tympanic cavity. The round window membrane can be exposed in 4 cases and failed in 5 cases. After 3 months of follow-up, we found that we found that 5/5 cases of aural fullness disappeared, 2/2 cases of earache disappeared, 3/8 cases of tinnitus improved, 5/8 cases presented with improvement and no aggravation, 3/3 cases of hearing allergy improved, 4/9 cases of hearing improved, and 5/9 cases showed no improvement or decrease. 9 patients were followed up for 3 months, of whom 8 patients had no vertigo, one patient suffered from vertigo twice within 3 months after operation, and the patient suffered from rupture of round window membrane. Conclusions: Endoscopic Tenotomy for Meniere's disease has obvious curative effect and quick recovery after operation. During the operation, we find that most of Meniere's patients have fibrous cord hyperplasia near the inner ear window membrane, which may be the pathological manifestation after repeated rupture and repair of the inner ear window membrane. The vertigo of Meniere's disease may be related to the destruction and repair of inner ear membrane structure caused by improper contraction or spasm of tympanic tensor muscle.


Asunto(s)
Enfermedad de Meniere , Acúfeno , Anciano , Femenino , Humanos , Hiperplasia/patología , Masculino , Enfermedad de Meniere/complicaciones , Enfermedad de Meniere/cirugía , Persona de Mediana Edad , Otoscopios/efectos adversos , Estudios Retrospectivos , Tenotomía/efectos adversos , Tensor del Tímpano/patología , Tensor del Tímpano/cirugía , Acúfeno/complicaciones , Vértigo/etiología
9.
Zhonghua Kou Qiang Yi Xue Za Zhi ; 52(4): 259-264, 2017 Apr 09.
Artículo en Zh | MEDLINE | ID: mdl-28412794

RESUMEN

Objective: To build scaffold materials with different concentrations of alginate and collagen, and to observe the effects of alginate/collagen ratio on the proliferation of human adipose-derived mesenchymal stem cells (hAMSC) and osteogenic differentiation. The optimal concentration of alginate/collagen will be chosen for constructing hydrogel that will be used for bone tissue engineering. Methods: Soluble hydrogel scaffold materials containing alginate/collagen were prepared, and the following groups were established based on different alginate/collagen ratio: 4∶1 (group A), 2∶1 (group B), and 1∶1 (group C). Cell proliferation on the material surface was observed using the cell counting kit-8 (CCK-8) assay, while cell viability in each material group were observed using live/dead staining. Quantitative real-time PCR(qPCR) was used to measure the differential expression of osteogenesis-related genes on and in the materials. Immunofluorescence staining was used to measure the differential gene expression of osteogenesis-related proteins in each group. Results: The results from the CCK-8 assay showed increasing cell proliferation rate on the lyophilized hydrogel material surface as the collagen concentration increased, and the highest cell proliferation was observed in group C. Live/dead staining assay indicated that cells were able to proliferate in all three types of hydrogel materials, and the highest cell viability was found in material from group B ([87.50±2.65]%). qPCR showed that the expression of osteogenesis-related genes in group C was the highest, among the three groups, while the expression of osteocalcin in group B was significantly higher than those in the other two groups (P<0.05). Immunofluorescence staining was carried out for osteocalcin on and in the hydrogel material and the results were consistent with that of qPCR. Conclusions: The alginate/collagen scaffold materials did not show adverse effects on the cell proliferation of hAMSC and osteogenenic differentiation. Bone tissue engineering can use 10% hydrogel material, and when the sodium alginate and collagen have a ratio of 2∶1, the hydrogel can be conducive to cell differentiation and proliferation.


Asunto(s)
Tejido Adiposo/citología , Alginatos/farmacología , Diferenciación Celular/efectos de los fármacos , Proliferación Celular/efectos de los fármacos , Colágeno/farmacología , Células Madre Mesenquimatosas/efectos de los fármacos , Osteogénesis/genética , Andamios del Tejido/química , Huesos , Recuento de Células/instrumentación , Supervivencia Celular , Expresión Génica , Ácido Glucurónico/farmacología , Ácidos Hexurónicos/farmacología , Humanos , Hidrogel de Polietilenoglicol-Dimetacrilato , Células Madre Mesenquimatosas/citología , Osteocalcina/metabolismo , Reacción en Cadena en Tiempo Real de la Polimerasa , Ingeniería de Tejidos/métodos
11.
Biomaterials ; 22(19): 2595-9, 2001 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-11519778

RESUMEN

Polysiloxane/liquid crystal composite membrane was first suggested to be used as biomaterials. In this work, the polydimethyl-methylhydrosiloxane and polydimethyl-methylethylenesilosiane, as a substrate, were blended with cholesteryl oleyl carbonate (COC) in tetrahydrofuran, and then crosslinked into membranes on glass plates by means of the platinum catalyst at 110 degrees C for 20 min. The effects of the liquid-crystal content in composite membranes on the formation of liquid-crystal phase were verified by the observation of optical polarization microscopy. The relationship between the morphology of the composite membranes and blood compatibility was identified by the dynamic blood-clotting tests, haemolysis ratio measurement, platelet adhesion and SEM observation. The results show that the blood-compatibility of composite membranes with the concentration of liquid crystal 20, 30% (wt) is more excellent than that of other composite membranes.


Asunto(s)
Materiales Biocompatibles , Fenómenos Fisiológicos Sanguíneos , Ésteres del Colesterol , Hemólisis , Histocompatibilidad/fisiología , Membranas Artificiales , Adhesividad Plaquetaria/fisiología , Siloxanos , Plaquetas/ultraestructura , Reactivos de Enlaces Cruzados , Furanos , Humanos , Microscopía Electrónica de Rastreo , Microscopía de Polarización , Solventes
12.
Leuk Lymphoma ; 27(5-6): 439-44, 1997 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-9477125

RESUMEN

Recent work has demonstrated the importance of Janus family kinases (JAKs) and signal transducers and activators of transcription (STATs) in the stimulus-response coupling of receptors lacking intrinsic tyrosine kinase activity. In particular, the JAK-STAT pathway appears critical in signal transduction by interferon as well as numerous hematopoietic growth factors interacting with members of the hemapoietin receptor superfamily. Although ligands that interact with receptor tyrosine kinases (RTK), such as epidermal growth factor (EGF), platelet-derived growth factor (PDGF) and colony stimulating factor-1 (CSF-1), have been shown to induce increases in phosphorylation of both JAKs and STATs, little is known about activation of this pathway by stem cell factor (SCF). This review will summarize what is known about the JAK/STAT pathway in relation to SCF signal transduction.


Asunto(s)
Proteínas de Unión al ADN/fisiología , Proteínas Tirosina Quinasas/metabolismo , Proteínas Proto-Oncogénicas , Transducción de Señal , Factor de Células Madre/fisiología , Activación Transcripcional , Animales , Líquido Cefalorraquídeo/metabolismo , Factor de Crecimiento Epidérmico/metabolismo , Hematopoyesis , Humanos , Interferones/fisiología , Janus Quinasa 2 , Ratones , Fosforilación , Factor de Crecimiento Derivado de Plaquetas/metabolismo , Proteínas Tirosina Quinasas/fisiología , Proteínas Tirosina Quinasas Receptoras/metabolismo
13.
J Chromatogr A ; 897(1-2): 205-14, 2000 Nov 03.
Artículo en Inglés | MEDLINE | ID: mdl-11128204

RESUMEN

High-performance ion chromatography (HPIC) is first successfully used to analyze tetracycline antibiotics (TCs) in this work. The TCs are well separated on a solvent compatible polymeric cation-exchange column within 12 min. Isocratic elution with acetonitrile-hydrochloride is very advantageous for routine analysis. HPIC may be seen as a specific variant of the more common high-performance liquid chromatography (HPLC) for water-soluble and polar pharmaceuticals with low hydrophobicity. The detection limits (signal-to-noise ratio=3:1) of oxytetracycline (OTC), tetracycline (TC), chlortetracycline (CTC), doxycycline (DC) are 10, 10, 20 and 20 microg l(-1), respectively. Samples are prepared by vortex mixing with an ethylenediaminetetraacetic acid disodium salt (Na2EDTA)-McIlvaine buffer (pH 4.0) solution and the mixture filtrates through a molecular weight cut-off filter. The method has been successfully applied to monitor the OTC removal rate through every reactor in the process of OTC manufacturing wastewater treatment by bio-chemical technology. It is also applicable to determine the TCs residues in milk and milk powder with satisfying results.


Asunto(s)
Ácidos/química , Cromatografía Líquida de Alta Presión/métodos , Polímeros/química , Tetraciclinas/análisis , Artefactos , Residuos de Medicamentos/análisis , Sensibilidad y Especificidad
14.
J Chromatogr A ; 920(1-2): 101-7, 2001 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-11452987

RESUMEN

The common eluents used with a bifunctional ion-exchange column (IonPac CS5A) for separating transition metals are pyridine-2,6-dicarboxylic acid and oxalic acid (Ox). When Ox is used, cadmium and manganese co-elute. Although much research has been done to overcome the Cd2+-Mn2+ co-elution problem, the role of lithium hydroxide in separating the transition metals has received little attention. In this study, it is found that when the Ox concentration is higher than 35 mM, Cu2+ elutes after Pb2+ and Ox plays a predominant role in the retention behavior of the seven metals. When Ox concentration is lower than 35 mM especially when its concentration (25 mM) is half of the usually used standard concentration (50 mM), Cu2+ elutes before Pb2+, and at the same time, Mn2+ and Cd2+ can also be baseline separated. Lithium hydroxide plays a predominant role in the separation of the metals separated by cation exchange. So, lithium hydroxide is used to adjust the pH of the eluent. The use of an isocratic elution (25 mM Ox/LiOH/2 mM Na2SO4, pH 3.88) allows the separation of seven metals (Cu2+, Pb2+, Co2+, Mn2+, Cd2+, Zn2+ and Ni2+) in a single run. The effects of inorganic modifiers such as NaNO3, Na2SO4 and Na4P3O7 on retention behavior of the metals are also investigated.


Asunto(s)
Cromatografía por Intercambio Iónico/instrumentación , Metales/química , Ácido Oxálico/química , Concentración de Iones de Hidrógeno
15.
J Chromatogr A ; 868(2): 209-16, 2000 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-10701671

RESUMEN

A system which combines column switching and concentration was developed. A binary eluent mechanism was developed to study the effect of high sample concentration matrix on retention time shifts of the trace analyte. Separation conditions were chosen according to this mechanism to reduce the retention time shift of ammonium in the presence of high concentration sodium ion: high concentration sulfuric acid (25 mmol/l) was used as the eluent, and a hydronium-selective column of high capacity--a CS12 column, was employed. Since the retention time shift was reduced, the interval between onset and the complete elution of a high concentration ammonium standard (10 mg/l) was directly defined as the column-switching time window, which greatly simplified the procedure for determining the time window. Results showed that for ammonium below 1 mg/l, 90% ammonium was introduced and concentrated. Detection limits of 12.8 microg/l were obtained for ammonium with sodium at 1000 mg/l.


Asunto(s)
Amoníaco/análisis , Cromatografía Liquida/métodos , Agua de Mar/química , Iones
16.
J Chromatogr A ; 857(1-2): 343-9, 1999 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-10536855

RESUMEN

A novel, highly sensitive method for simultaneous separation and determination of Cu2+, Ni2+, Zn2+, Cd2+, Co2+, Mn2+ and Pb2+ in biochemical samples was developed and evaluated by ion chromatography. All of these metals were well separated on a bifunctional ion-exchange column by a concentration gradient of oxalic acid and sodium chloride eluents, coupled with spectrophotometric detection after post-column derivatization with 2-[(5-bromo-2-pyridyl)azo]-5-diethylaminophenol at 560 nm. The method detection limits (signal-to-noise 3:1) were at microg l(-1) levels. The calibration graphs were linear (r2>0.999) over two-orders of magnitude. This technique was optimized and validated by analyzing five standard biochemical references.


Asunto(s)
Cromatografía por Intercambio Iónico/métodos , Metales Pesados/análisis , Animales , Bivalvos/química , Hígado/química , Plantas/química , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Porcinos
17.
J Chromatogr A ; 884(1-2): 53-9, 2000 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-10917422

RESUMEN

A binary eluent model was proposed to study the retention behavior of trace anions in the presence of high concentrations of co-eluent anions. According to this model, the effect of the matrix on the retention of trace anions can be suppressed by using a high-concentration eluent. Based on the model, a simplified 'heart-cut' column-switching technology was proposed, in which the column-switching time window can be determined directly by standard solution of the analyte. By using this technology, a detection limit of 50 microg/l was obtained for nitrate in the presence of 5,000 mg/l chloride and 250 mg/l sulfate. The effect of the matrix on the concentration efficiency of weak acid anions was studied according to the result of phosphate. The possibility of the determination of weak acid anion by the 'heart-cut' technology was also discussed. The technology has been applied for the determination of nitrate in high salinity sea water, the spike recovery is in the range of 89.2-101.3%.


Asunto(s)
Aniones/análisis , Cromatografía Liquida/instrumentación , Cromatografía Liquida/métodos
18.
J Chromatogr A ; 883(1-2): 127-36, 2000 Jun 23.
Artículo en Inglés | MEDLINE | ID: mdl-10910207

RESUMEN

An improved scheme of chelation ion chromatography (CIC) system and a mixed eluent for the simultaneous determination of transition metals are described. A method based on the improved CIC system and the mixed eluent (PDCA/Na2C2O4/LiOH/NaCl) for the analysis of seven metals (Pb2+, Cu2+, Ni2+, Zn2+, Co2+, Cd2+ and Mn2+) at microg l(-1) levels in a single isocratic elution is developed. The optimize conditions which are different from references for analyte concentration and chromatographic separation are studied in detail. D418 chelation resin is used to further reduce values of the reagent blank. The above seven metals are measured at 565 nm using 2-[(5-Bromo-2-Pyridyl)-Azo]-5-Diethyl-AminoPhenol(5-Br-PADAP) as the post-column derivatizing reagent. Detection limits range from 0.3 to 12 microg l(-1) when 4 ml of sample is pre-concentrated. The results of real sample analysis are satisfactory.


Asunto(s)
Quelantes/química , Cromatografía Liquida/métodos , Metales/análisis , Iones , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
19.
J Chromatogr A ; 850(1-2): 277-81, 1999 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-10457488

RESUMEN

In this paper, the separation and determination of the sweetener aspartame by ion chromatography coupled with electrochemical amperometric detection is reported. Sodium saccharin, acesulfame-K and aspartame were separated using 27.5 mmol/l NaOH isocratic elution on a Dionex IonPac AS4A-SC separation column. Aspartame can be determined by integrated amperometric detection without interference from the other two sweeteners. The method can be applied to the determination of aspartame in powered tabletop, fruit juice and carbonated beverage samples, and the results obtained by integrated amperometry were in agreement with those obtained using a UV detection method. A method for determining analytes with an NH2 group by ion chromatography with integrated amperometry was developed.


Asunto(s)
Aspartame/análisis , Cromatografía por Intercambio Iónico/métodos , Electroquímica
20.
J Chromatogr A ; 800(2): 247-55, 1998 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-9561765

RESUMEN

A novel, highly sensitive method for the simultaneous separation and determination of lead, copper, cadmium and other transition metals in drinking water was achieved by on-line sample pretreatment of chelation ion chromatography. Manganese, which coeluted with cadmium, was oxidized to permanganate by ammonium persulfate before injection. Permanganate, with bulk quantity of alkali, alkaline earth metals, iron and aluminum, was eliminated by pyrophosphoric acid-ammonium acetate buffer solution (pH 5.5), while retaining heavy and transition metals on a selective chelating resin (MetPac CC-1 column). Then, they were disabsorbed and transferred to a sulfonated cation exchanger (TMC-1 column). Finally, the concentrated trace metals were separated on a bifunctional ion-exchange column (CS5A) by a concentration gradient of oxalic acid and sodium nitrate eluents, coupled with post-column spectrophotometric detection with 2-[(5-bromo-2-pyridyl)azo]-5-diethylaminophenol (5-Br-PADAP) at 560 nm. The separation and color-development conditions were optimized. The detection limits for the method (signal-to-noise ratio = 3:1) were at or below the microgram l-1 level. The results of drinking water analyses were satisfactory.


Asunto(s)
Quelantes/química , Cromatografía por Intercambio Iónico/métodos , Agua Dulce/química , Metales Pesados/química , Sistemas en Línea , Contaminantes Químicos del Agua/análisis , Purificación del Agua/métodos , Cadmio/química , Cobre/química , Concentración de Iones de Hidrógeno , Plomo/química , Modelos Lineales , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS