Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Clin Orthop Relat Res ; 480(11): 2232-2250, 2022 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-36001022

RESUMEN

BACKGROUND: A nanostructured titanium surface that promotes antimicrobial activity and osseointegration would provide the opportunity to create medical implants that can prevent orthopaedic infection and improve bone integration. Although nanostructured surfaces can exhibit antimicrobial activity, it is not known whether these surfaces are safe and conducive to osseointegration. QUESTIONS/PURPOSES: Using a sheep animal model, we sought to determine whether the bony integration of medical-grade, titanium, porous-coated implants with a unique nanostructured surface modification (alkaline heat treatment [AHT]) previously shown to kill bacteria was better than that for a clinically accepted control surface of porous-coated titanium covered with hydroxyapatite (PCHA) after 12 weeks in vivo. The null hypothesis was that there would be no difference between implants with respect to the primary outcomes: interfacial shear strength and percent intersection surface (the percentage of implant surface with bone contact, as defined by a micro-CT protocol), and the secondary outcomes: stiffness, peak load, energy to failure, and micro-CT (bone volume/total volume [BV/TV], trabecular thickness [Tb.Th], and trabecular number [Tb.N]) and histomorphometric (bone-implant contact [BIC]) parameters. METHODS: Implants of each material (alkaline heat-treated and hydroxyapatite-coated titanium) were surgically inserted into femoral and tibial metaphyseal cancellous bone (16 per implant type; interference fit) and in tibial cortices at three diaphyseal locations (24 per implant type; line-to-line fit) in eight skeletally mature sheep. At 12 weeks postoperatively, bones were excised to assess osseointegration of AHT and PCHA implants via biomechanical push-through tests, micro-CT, and histomorphometry. Bone composition and remodeling patterns in adult sheep are similar to that of humans, and this model enables comparison of implants with ex vivo outcomes that are not permissible with humans. Comparisons of primary and secondary outcomes were undertaken with linear mixed-effects models that were developed for the cortical and cancellous groups separately and that included a random effect of animals, covariates to adjust for preoperative bodyweight, and implant location (left/right limb, femoral/tibial cancellous, cortical diaphyseal region, and medial/lateral cortex) as appropriate. Significance was set at an alpha of 0.05. RESULTS: The estimated marginal mean interfacial shear strength for cancellous bone, adjusted for covariates, was 1.6 MPa greater for AHT implants (9.3 MPa) than for PCHA implants (7.7 MPa) (95% CI 0.5 to 2.8; p = 0.006). Similarly, the estimated marginal mean interfacial shear strength for cortical bone, adjusted for covariates, was 6.6 MPa greater for AHT implants (25.5 MPa) than for PCHA implants (18.9 MPa) (95% CI 5.0 to 8.1; p < 0.001). No difference in the implant-bone percent intersection surface was detected for cancellous sites (cancellous AHT 55.1% and PCHA 58.7%; adjusted difference of estimated marginal mean -3.6% [95% CI -8.1% to 0.9%]; p = 0.11). In cortical bone, the estimated marginal mean percent intersection surface at the medial site, adjusted for covariates, was 11.8% higher for AHT implants (58.1%) than for PCHA (46.2% [95% CI 7.1% to 16.6%]; p < 0.001) and was not different at the lateral site (AHT 75.8% and PCHA 74.9%; adjusted difference of estimated marginal mean 0.9% [95% CI -3.8% to 5.7%]; p = 0.70). CONCLUSION: These data suggest there is stronger integration of bone on the AHT surface than on the PCHA surface at 12 weeks postimplantation in this sheep model. CLINICAL RELEVANCE: Given that the AHT implants formed a more robust interface with cortical and cancellous bone than the PCHA implants, a clinical noninferiority study using hip stems with identical geometries can now be performed to compare the same surfaces used in this study. The results of this preclinical study provide an ethical baseline to proceed with such a clinical study given the potential of the alkaline heat-treated surface to reduce periprosthetic joint infection and enhance implant osseointegration.


Asunto(s)
Antiinfecciosos , Oseointegración , Animales , Antiinfecciosos/farmacología , Durapatita/farmacología , Humanos , Prótesis e Implantes , Ovinos , Propiedades de Superficie , Titanio/farmacología
2.
J Neurotrauma ; 40(9-10): 965-980, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36200622

RESUMEN

Spinal cord injury (SCI) frequently results in motor, sensory, and autonomic dysfunction for which there is currently no cure. Recent pre-clinical and clinical research has led to promising advances in treatment; however, therapeutics indicating promise in rodents have not translated successfully in human trials, likely due, in part, to gross anatomical and physiological differences between the species. Therefore, large animal models of SCI may facilitate the study of secondary injury processes that are influenced by scale, and may assist the translation of potential therapeutic interventions. The aim of this study was to characterize two severities of thoracic contusion SCI in female domestic pigs, measuring motor function and spinal cord lesion characteristics, over 2 weeks post-SCI. A custom-instrumented weight-drop injury device was used to release a 50 g impactor from 10 cm (n = 3) or 20 cm (n = 7) onto the exposed dura, to induce a contusion at the T10 thoracic spinal level. Hind limb motor function was assessed at 8 and 13 days post-SCI using a 10-point scale. Volume and extent of lesion-associated signal hyperintensity in T2-weighted magnetic resonance (MR) images were assessed at 3, 7, and 14 days post-injury. Animals were transcardially perfused at 14 days post-SCI and spinal cord tissue was harvested for histological analysis. Bowel function was retained in all animals and transient urinary retention occurred in one animal after catheter removal. All animals displayed hind limb motor deficits. Animals in the 10-cm group demonstrated some stepping and weight-bearing and scored a median 2-3 points higher on the 10-point motor function scale at 8 and 13 days post-SCI, than did the 20-cm group. Histological lesion volume was 20% greater, and 30% less white matter was spared, in the 20-cm group than in the 10-cm group. The MR signal hyperintensity in the 20-cm injury group had a median cranial-caudal extent approximately 1.5 times greater than the 10-cm injury group at all three time-points, and median volumes 1.8, 2.5, and 4.5 times greater at day 3, 7, and 14 post-injury, respectively. Regional differences in axonal injury were observed between groups, with amyloid precursor protein immunoreactivity greatest in the 20-cm group in spinal cord sections adjacent to the injury epicenter. This study demonstrated graded injuries in a domestic pig strain, with outcome measures comparable to miniature pig models of contusion SCI. The model provides a vehicle for the study of SCI and potential treatments, particularly where miniature pig strains are not available and/or where small animal models are not appropriate for the research question.


Asunto(s)
Contusiones , Traumatismos de la Médula Espinal , Femenino , Porcinos , Humanos , Animales , Porcinos Enanos , Modelos Animales de Enfermedad , Médula Espinal/patología
3.
Spine (Phila Pa 1976) ; 41(17): 1331-1339, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26913464

RESUMEN

STUDY DESIGN: In-vivo ovine model of intervertebral disc degeneration (IVD) to evaluate treatment with stem cells. OBJECTIVE: To determine if stem cells delivered to the nucleus pulposus (NP) or the annulus fibrosus (AF) of degenerated lumbar IVDs leads to improved indices of disc health. SUMMARY OF BACKGROUND DATA: Previous studies assessing the efficacy of stem cell injections into degenerated IVDs have reported positive findings. However, studies have been limited to small animals, targeting solely the NP, with short term follow-up. METHODS: Mesenchymal precursor cells (MSC) were obtained from the iliac crest of 8-week-old sheep. IVD degeneration was induced by postero-lateral annulotomy at three lumbar levels in eight 2-year-old sheep. Six months later, each degenerated IVD was randomized to one of three treatments: Injection of MSC into (i) previously incised AF (AFI), (ii) NP (NPI), or (iii) no injection (negative control, NC). The adjacent IVD received injection of phosphate buffered saline into NP (positive control, PC). Radiographs and magnetic resonance imaging scans were obtained at baseline, 6, 9, and 12 months. Discs were harvested at 12 months for biochemical and histological analyses. RESULTS: IVD degeneration was consistently observed postannulotomy, and characterized by reduced disc height index (DHI), disc height (DH), glycosaminoglycan (GAG) content, and increased grade of disc degeneration.Six months after stem cell injection, DHI and DH had recovered in AFI and NPI groups when compared with NC group (P < 0.01). Mean Pfirrmann grade improved from 3.25 to 2.67 (AFI group) and from 2.96 to 2.43 (NPI group). Mean histopathological grade improved for both AFI (P < 0.002) and NPI (P < 0.02) groups. Both AFI and NPI groups demonstrated spontaneous repair of the postero-lateral annular lesion. CONCLUSION: In this large animal model, injection of MSCs into the annulus fibrosus or the nucleus pulposus of degenerated IVD resulted in significant improvements in disc health. LEVEL OF EVIDENCE: N/A.


Asunto(s)
Degeneración del Disco Intervertebral/patología , Disco Intervertebral/patología , Vértebras Lumbares/patología , Trasplante de Células Madre Mesenquimatosas , Células Madre Mesenquimatosas/citología , Cicatrización de Heridas/efectos de los fármacos , Animales , Modelos Animales de Enfermedad , Glicosaminoglicanos/análisis , Degeneración del Disco Intervertebral/terapia , Imagen por Resonancia Magnética/métodos , Trasplante de Células Madre Mesenquimatosas/métodos , Ovinos
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda