INTRODUCTION: Sample preparation in bio analytical chemistry poses a challenge because it can be compound dependent. We compared six sample extraction techniques i.e. QuEChERS (Q), liquid extraction (LE), protein precipitation (PPT), Q-PPT, Q-LE and LE-PPT for the extraction of antiretroviral drugs emtricitabine, tenofovir, efavirenz, lopinavir and rotinavir in human blood plasma. METHOD: A multiple reaction monitoring liquid chromatography- tandem mass spectrometry method for the determination of the same antiretroviral drugs developed and validated in this laboratory was used. Comparisons were based on the efficiencies of extraction, the precisions and accuracies. Using United States Food and Drug Administration guidelines, analytical performance characteristics i.e. limits of detection, lower limits of quantification and upper limits of quantification were also compared. RESULTS: The percent mean recoveries ranged between 68.8 and 81.2% for single modes and 52.4-70.5% for mixed mode techniques. The precisions of all the extraction techniques were within the Using United States Food and Drug Administration guidelines acceptable range of <15% at all concentration levels for all analytes. Accuracy ranged between 8.73 and 65.94% for single mode techniques and between 21.73 and 51.59% for mixed mode techniques. DISCUSSION: The mixed modes gave slightly lower recoveries but Q-LE compared well with the single modes at slightly higher spike levels. Limits of detection for all the six sample preparation techniques fell below the clinically relevant therapeutic range of approximately 3-8ppm. Therefore all techniques can be employed for routine therapeutic drug monitoring studies.


Asunto(s)
Métodos Analíticos de la Preparación de la Muestra/métodos , Antirretrovirales/sangre , Monitoreo de Drogas/métodos , Métodos Analíticos de la Preparación de la Muestra/instrumentación , Cromatografía Líquida de Alta Presión/instrumentación , Cromatografía Líquida de Alta Presión/métodos , Monitoreo de Drogas/instrumentación , Humanos , Límite de Detección , Estándares de Referencia , Reproducibilidad de los Resultados , Reserpina/análisis , Infecciones por Retroviridae/sangre , Infecciones por Retroviridae/tratamiento farmacológico , Espectrometría de Masa por Ionización de Electrospray/instrumentación , Espectrometría de Masa por Ionización de Electrospray/métodos , Espectrometría de Masas en Tándem/instrumentación , Espectrometría de Masas en Tándem/métodos
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda