Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Tipo del documento
Publication year range
1.
Rev Gastroenterol Peru ; 36(3): 231-241, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27716760

RESUMEN

Teaching models in endoscopy are important tools to minimize risks derived from endoscopic procedures, taking into account that therapeutic endoscopy, also known as surgical endoscopy, has greatly developed during the last decade. This results from the fact that minimally invasive procedures present relevant contributions and promote more comfort to patients. In this context, ex vivo teaching models and virtual simulators are important tools to the safe acquisition of abilities. In this article, the Brazilian Society of Digestive Endoscopy presents and describes its first course of therapeutic ERCP and EUS in models of laboratory teaching.


Asunto(s)
Colangiopancreatografia Retrógrada Endoscópica , Endoscopía Gastrointestinal/educación , Endosonografía , Gastroenterología/educación , Modelos Educacionales , Entrenamiento Simulado/métodos , Animales , Brasil , Pollos , Simulación por Computador , Curriculum , Humanos , Técnicas In Vitro , Modelos Anatómicos , Porcinos
2.
Arq Bras Cir Dig ; 29(4): 269-271, 2016.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-28076484

RESUMEN

Background: Models for endoscopic retrograde cholangiopancreatography training allow practice with an expert feedback and without risks. A method to rapidly exchange the papilla can be time saving and accelerate the learning curve. Aim: To demonstrate a newly method of rapid exchange papilla in ex-vivo models to teach retrograde cholangiopancreatography advanced procedures. Methods: A new model of ex-vivo papilla was developed in order to resemble live conditions of procedures as cannulation, papilotomy or fistula-papilotomy, papiloplasty, biliary dilatation, plastic and metallic stentings. Results: The ex-vivo model of papilla rapid exchange is feasible and imitates with realism conditions of retrograde cholangiopancreatography procedures. Conclusion: This model allows an innovative method of advanced endoscopic training.


Racional: Nas últimas décadas os simuladores de colangiopancreatografia retrógrada tiveram grande evolução. Atualmente dispõem-se de vários métodos para realizar o treinamento minimizando os riscos de complicações e tornando a curva de aprendizagem muito rápida. Objetivo: Demonstrar uma variação dos modelos ex-vivos desenvolvidos para o treinamento avançado em colangiopancreatografia retrograda. Método: Foi criado um modelo ex-vivo simulando fatores e condições reais para o treinamento avançado de colangiopancreatografia retrograda como canulação, papilotomia, fistulotomia, papiloplastia e uso de próteses plásticas e metálicas. Resultados: Esse modelo ex-vivo, com a possibilidade de troca rápida da papila, mostrou-se viável e no treinamento simula condições muito próximas às reais. Conclusão: Neste modelo há grande inovação para o treinamento de novos endoscopistas em procedimento avançados na colangiopancreatografia retrógrada.


Asunto(s)
Ampolla Hepatopancreática , Colangiopancreatografia Retrógrada Endoscópica/métodos , Radiología/educación , Animales , Modelos Animales , Porcinos , Factores de Tiempo
3.
ABCD (São Paulo, Impr.) ; 29(4): 269-271, Oct.-Dec. 2016. graf
Artículo en Inglés | LILACS | ID: biblio-837542

RESUMEN

ABSTRACT Background: Models for endoscopic retrograde cholangiopancreatography training allow practice with an expert feedback and without risks. A method to rapidly exchange the papilla can be time saving and accelerate the learning curve. Aim: To demonstrate a newly method of rapid exchange papilla in ex-vivo models to teach retrograde cholangiopancreatography advanced procedures. Methods: A new model of ex-vivo papilla was developed in order to resemble live conditions of procedures as cannulation, papilotomy or fistula-papilotomy, papiloplasty, biliary dilatation, plastic and metallic stentings. Results: The ex-vivo model of papilla rapid exchange is feasible and imitates with realism conditions of retrograde cholangiopancreatography procedures. Conclusion: This model allows an innovative method of advanced endoscopic training.


RESUMO Racional: Nas últimas décadas os simuladores de colangiopancreatografia retrógrada tiveram grande evolução. Atualmente dispõem-se de vários métodos para realizar o treinamento minimizando os riscos de complicações e tornando a curva de aprendizagem muito rápida. Objetivo: Demonstrar uma variação dos modelos ex-vivos desenvolvidos para o treinamento avançado em colangiopancreatografia retrograda. Método: Foi criado um modelo ex-vivo simulando fatores e condições reais para o treinamento avançado de colangiopancreatografia retrograda como canulação, papilotomia, fistulotomia, papiloplastia e uso de próteses plásticas e metálicas. Resultados: Esse modelo ex-vivo, com a possibilidade de troca rápida da papila, mostrou-se viável e no treinamento simula condições muito próximas às reais. Conclusão: Neste modelo há grande inovação para o treinamento de novos endoscopistas em procedimento avançados na colangiopancreatografia retrógrada.


Asunto(s)
Animales , Radiología/educación , Ampolla Hepatopancreática , Colangiopancreatografia Retrógrada Endoscópica/métodos , Porcinos , Factores de Tiempo , Modelos Animales
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda