Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
J Refract Surg ; 22(1): 102-3, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16447943

RESUMEN

PURPOSE: To present a case of traumatic dislocation of an Ophtec Artisan phakic intraocular lens (PIOL) and an analysis of the endothelial cell count. METHODS: The patient presented with blurred vision in his left eye after sustaining a brow laceration. History included uncomplicated bilateral implantation of an Artisan PIOL to correct myopia. RESULTS: The brow laceration was sutured and topical dexamethasone 0.1% qid was prescribed. One week after presentation, the PIOL was relocated. Postoperatively, endothelial cell count analysis was performed in both eyes. CONCLUSIONS: A decrease in the hexagonality of the endothelial cells was noted in both eyes, which was substantially lower in the injured eye.


Asunto(s)
Endotelio Corneal/patología , Lesiones Oculares/complicaciones , Migración de Cuerpo Extraño/cirugía , Lentes Intraoculares , Técnicas de Sutura , Cámara Anterior , Recuento de Células , Endotelio Corneal/lesiones , Lesiones Oculares/patología , Lesiones Oculares/cirugía , Estudios de Seguimiento , Migración de Cuerpo Extraño/etiología , Migración de Cuerpo Extraño/patología , Humanos , Iris/cirugía , Implantación de Lentes Intraoculares , Masculino , Persona de Mediana Edad , Miopía/cirugía , Agudeza Visual
2.
Br J Ophthalmol ; 75(1): 38-41, 1991 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-1991085

RESUMEN

The design and use of a new device for obtaining corneoscleral buttons for storage and corneal discs for keratoplasty from neonatal and adult donor eyes is described. The device is simple to use and eliminates most of the difficulties in handling infant donor eyes. It thus minimises the risk of damage to the corneal endothelium and the formation of stretch striae, which reduce the quality of the donor material for transplantation.


Asunto(s)
Trasplante de Córnea/métodos , Recién Nacido , Oftalmología/instrumentación , Donantes de Tejidos , Adulto , Córnea/anatomía & histología , Endotelio Corneal/anatomía & histología , Humanos , Preservación de Órganos , Manejo de Especímenes
3.
Br J Ophthalmol ; 73(2): 121-5, 1989 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-2649146

RESUMEN

Posterior folds in human donor corneas stored as whole eyes in moist chambers, or isolated in McCarey-Kaufman medium at 4 degrees C, have been studied by light and scanning electron microscopy to determine whether or not endothelial cells on the folds are damaged. Extensive, often irreversible cell damage was found associated with most of the folds. Hence posterior folds in donor corneas are of importance in that they indirectly reduce the quality of the donor cornea for transplantation.


Asunto(s)
Córnea/ultraestructura , Anciano , Anciano de 80 o más Años , Trasplante de Córnea , Endotelio Corneal/ultraestructura , Femenino , Humanos , Masculino , Microscopía Electrónica de Rastreo , Persona de Mediana Edad , Preservación de Órganos , Factores de Tiempo
4.
Br J Ophthalmol ; 74(5): 261-4, 1990 May.
Artículo en Inglés | MEDLINE | ID: mdl-2354131

RESUMEN

Six human donor corneas were studied with the scanning electron microscope to quantify the hazards to the endothelium during the excision of corneoscleral buttons. Although the number studied was small, it was found that: (1) striae were more numerous in the flaccid, very young, donor corneas (under 1 year old) than in the more rigid adult corneas: (2) iridocorneal endothelial touch can result in loss of the posterior membrane and death of the touched endothelial cells. This corroborates the findings of other investigators. Both findings are important, because these conditions reduce the quality of the donor cornea for transplantation.


Asunto(s)
Trasplante de Córnea , Endotelio Corneal/ultraestructura , Adolescente , Supervivencia Celular , Femenino , Humanos , Lactante , Masculino , Microscopía Electrónica de Rastreo , Persona de Mediana Edad , Manejo de Especímenes , Donantes de Tejidos , Conservación de Tejido
5.
Cornea ; 17(5): 544-9, 1998 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-9756450

RESUMEN

PURPOSE: To evaluate changes in the donor corneal endothelium in the intact globe and in the in vivo rabbit cornea to characterize more fully the formation of "dark events" without relief images in the endothelial mosaic. METHODS: Six ex vivo human donor corneas in the intact globe and an in vivo rabbit model were used to assess the morphological changes associated with osmotically increasing fluid movement from the anterior chamber into the stroma by specular (SM), confocal (CM), and transmission and scanning electron microscopy (TEM, SEM). RESULTS: After application of hyperosmotic solution on the anterior surface of the cornea, dark events without relief images were observed by SM and CM. In both human and rabbit corneas, SEM showed that apical pores at the Y-junctions between endothelial cells became enlarged. Large subendothelial spaces were observed on Descemet's membrane by TEM with some spaces communicating with the anterior chamber. CONCLUSIONS: The findings suggest that these openings at the Y-junctions may represent intercellular channels that may also act as pathways for the formation of intercellular and subendothelial vacuoles in both the rabbit and human donor corneal endothelium. By virtue of their location, these vacuoles are characterized by lack of relief images as seen with the contact SM.


Asunto(s)
Endotelio Corneal/ultraestructura , Adulto , Anciano , Animales , Cámara Anterior/efectos de los fármacos , Transporte Biológico , Sustancia Propia/efectos de los fármacos , Endotelio Corneal/efectos de los fármacos , Humanos , Soluciones Hipertónicas/farmacología , Microscopía Confocal , Microscopía Electrónica , Microscopía Electrónica de Rastreo , Persona de Mediana Edad , Ósmosis , Conejos , Sacarosa/farmacología
7.
Br J Ophthalmol ; 79(4): 396, 1995 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-7742300
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda