1.
J Pharm Biomed Anal ; 33(5): 1103-15, 2003 Dec 04.
Artículo en Inglés | MEDLINE | ID: mdl-14656601

RESUMEN

The aim of the study was to assess the feasibility of metabonomics in clinical studies. A 1H nuclear magnetic resonance (NMR)-based metabonomic analysis was performed on plasma and urine samples obtained from a group of 12 healthy male subjects on two separate study days 14 days apart. The subjects were fed a standard diet and plasma and urine samples were obtained on both days. The 1H NMR spectra obtained for urine and plasma samples were analysed using principal components analysis (PCA) in order to generate metabonomic data. In plasma there was relatively little variability between subjects and study days. In the case of endogenous urinary metabolite profiles there was considerable inter-subject variability, but less intra-subject variation. In all subjects diurnal variation was seen with urine samples. This suggests the possibility to collect consistent metabonomics data in clinical studies.


Asunto(s)
Análisis Químico de la Sangre/métodos , Resonancia Magnética Nuclear Biomolecular/métodos , Urinálisis/métodos , Adulto , Análisis Químico de la Sangre/normas , Ritmo Circadiano/fisiología , Glucosa/metabolismo , Humanos , Individualidad , Lípidos/sangre , Lípidos/orina , Masculino , Persona de Mediana Edad , Análisis de Componente Principal/métodos , Análisis de Componente Principal/normas , Protones , Urinálisis/normas
2.
Rheumatology (Oxford) ; 43(1): 19-21, 2004 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-12923282

RESUMEN

OBJECTIVE: To investigate the variability between different high-field scanners in magnetic resonance imaging (MRI) measurement of knee cartilage volume in healthy female volunteers. METHODS: Five volunteers had both knees scanned using three different MRI scanners. Cartilage volume in each compartment was measured from the images by image segmentation. The data were analysed using analysis of variance models. RESULTS: The mean total cartilage volume of the 10 knees scanned at three different centres was 16.15, 16.40 and 15.63 ml for the Siemens, GE and Philips scanners respectively. Small systematic differences were seen in the total knee cartilage volume results. CONCLUSIONS: Although there were small systematic differences in knee cartilage volume, the three MRI scanners gave broadly similar results.


Asunto(s)
Cartílago Articular/anatomía & histología , Articulación de la Rodilla/anatomía & histología , Imagen por Resonancia Magnética/instrumentación , Adulto , Análisis de Varianza , Anatomía Transversal , Femenino , Humanos , Persona de Mediana Edad , Sensibilidad y Especificidad
3.
Eur Radiol ; 14(11): 1968-73, 2004 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-15309497

RESUMEN

The purpose was to evaluate the inter-visit, inter-observer and intra-observer variation of quantitative and qualitative tendon examinations in vivo for a cohort of asymptomatic volunteers. Eleven healthy male subjects were recruited. The following tendons were assessed by ultrasonography: Achilles tendon, patellar tendon, triceps tendon, extensor pollicis longus, flexor carpi radialis and supraspinatus. For each tendon a quantitative measurement of tendon size was made at a predefined anatomical location. Two experienced sonologists, blind to one another's findings, evaluated each of the tendons independently. Each tendon was evaluated on two occasions 1 week apart. No difference was found to be attributed to variation in tendon size between visits. Inter-observer variation was a source of error with intra-subject, inter-visit measurements proving more reproducible. There was some significant variation between observers. This variation was more marked with some tendon measures than others. Inter-observer variation for triceps, flexor carpi radialis and supraspinatus was most marked. Minimum detectable change in tendons varied from 13 to 57% depending on the plane of scanning and the tendon being examined. Good reproducibility of quantitative tendon measurements can be achieved within a study using two observers by following a defined scanning protocol. However, it is recommended that the same observer perform serial assessments. The data allow minimal detectable changes in tendon size to be calculated.


Asunto(s)
Tendones/anatomía & histología , Tendones/diagnóstico por imagen , Adulto , Estudios de Cohortes , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valores de Referencia , Reproducibilidad de los Resultados , Ultrasonografía Doppler/métodos