Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Electrophoresis ; 42(9-10): 1093-1101, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33665842

RESUMEN

Electroporation is a promising method to inactivate cells and it has wide applications in medical science, biology and environmental health. Here, we investigate the bacteria inactivation performance of two different microfluidic electroporation devices with rhombus and circular micropillars used for generating locally enhanced electric field strength. Experiments are carried out to characterize the inactivation performance (i.e., the log removal efficiency) of two types of bacteria: Escherichia coli (E. coli, gram-negative) and Enterococcus faecalis (E. faecalis, gram-positive) in these two microfluidic devices. We find that under the same applied electric field, the device with rhombus micropillars performs better than the device with circular micropillars for both E. coli and E. faecalis. Numerical simulations show that due to the corner-induced singularity effect, the maximum electric field enhancement is higher in the device with rhombus micropillars than that in the device with circular micropillars. We also study the effects of DC and AC electric fields and flowrate. Our experiments demonstrate that the use of the DC field achieves higher log removal efficiencies than the use of AC field.


Asunto(s)
Microfluídica , Electricidad , Electroporación , Escherichia coli , Dispositivos Laboratorio en un Chip
2.
Biotechnol Bioeng ; 117(4): 1127-1136, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31885078

RESUMEN

Disruption of the blood-brain barrier (BBB) leads to various neurovascular diseases. Development of therapeutics required to cross the BBB is difficult due to a lack of relevant in vitro models. We have developed a three-dimensional (3D) microfluidic BBB chip (BBBC) to study cell interactions in the brain microvasculature and to test drug candidates of neurovascular diseases. We isolated primary brain microvascular endothelial cells (ECs), pericytes, and astrocytes from neonatal rats and cocultured them in the BBBC. To mimic the 3D in vivo BBB structure, we used type I collagen hydrogel to pattern the microchannel via viscous finger patterning technique to create a matrix. ECs, astrocytes, and pericytes were cocultured in the collagen matrix. The fluid flow in the BBBC was controlled by a pump-free strategy utilizing gravity as driving force and resistance in a paper-based flow resistor. The primary cells cultured in the BBBC expressed high levels of junction proteins and formed a tight endothelial barrier layer. Addition of tumor necrosis factor alpha to recapitulate neuroinflammatory conditions compromised the BBB functionality. To mitigate the neuroinflammatory stimulus, we treated the BBB model with the glucocorticoid drug dexamethasone, and observed protection of the BBB. This BBBC represents a new simple, cost-effective, and scalable in vitro platform for validating therapeutic drugs targeting neuroinflammatory conditions.


Asunto(s)
Barrera Hematoencefálica , Técnicas de Cocultivo/instrumentación , Evaluación Preclínica de Medicamentos/instrumentación , Dispositivos Laboratorio en un Chip , Animales , Antiinflamatorios/farmacología , Astrocitos/citología , Astrocitos/efectos de los fármacos , Astrocitos/metabolismo , Barrera Hematoencefálica/citología , Barrera Hematoencefálica/efectos de los fármacos , Barrera Hematoencefálica/metabolismo , Encéfalo/citología , Células Cultivadas , Técnicas de Cocultivo/métodos , Diseño de Equipo , Inflamación/metabolismo , Técnicas Analíticas Microfluídicas/instrumentación , Pericitos/citología , Pericitos/efectos de los fármacos , Pericitos/metabolismo , Ratas , Ratas Sprague-Dawley
3.
Electrophoresis ; 40(18-19): 2522-2529, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31177580

RESUMEN

Electroporation is a powerful tool for inactivating cells and transfecting biological cells and has applications in biology, genetic engineering, medicine, environment, and many others. We report a new continuous flow device embedded with insulating micropillars to achieve better performance of cell inactivation. The use of micropillars creates multiple electroporation zones with enhanced local electric field strengths. Using a model solution of Saccharomyces cerevisiae, we examined the inactivation performance of the device under various applied electric voltages and flow rates. Results from the numerical simulations and experiments showed that even with an induced transmembrane potential of 0.58 V, close to 63% of cell inactivation was achieved at a flow rate of 2.5 mL/h. This was higher than the 24% cell inactivation observed for a reference device without micropillars that was subjected to the same conditions.


Asunto(s)
Técnicas Citológicas/instrumentación , Electroporación/instrumentación , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Citológicas/métodos , Electroporación/métodos , Diseño de Equipo , Técnicas Analíticas Microfluídicas/métodos , Saccharomyces cerevisiae/citología
4.
Electrophoresis ; 37(19): 2458-2461, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-27122248

RESUMEN

Heavy metals and some metalloids are the most significant inorganic contaminants specified in toxicity characteristic leaching procedure (TCLP) in determining the safety of landfills or further utilization. As a consequence, a great deal of efforts had been made on the development of miniaturized analytical devices, such as Microchip Electrophoresis (ME) and µTAS for on-site testing of heavy metals and metalloids to prevent spreading of those pollutants or decrease the reutilization period of waste materials such as incineration bottom ash. However, the bottleneck lied in the long and tedious conventional TCLP that requires 18 h of leaching. Without accelerating the TCLP process, the on-site testing of the waste material leachates was impossible. In this study, therefore, a new accelerated leaching method (ALM) combining ultrasonic assisted leaching with tumbling was developed to reduce the total leaching time from 18 h to 30 min. After leaching, the concentrations of heavy metals and metalloids were determined with ICP-MS or ICP-optical emission spectroscopy. No statistical significance between ALM and TCLP was observed for most heavy metals (i.e., cobalt, manganese, mercury, molybdenum, nickel, silver, strontium, and tin) and metalloids (i.e., arsenic and selenium). For the heavy metals with statistical significance, correlation factors derived between ALM and TCLP were 0.56, 0.20, 0.037, and 0.019 for barium, cadmium, chromium, and lead, respectively. Combined with appropriate analytical techniques (e.g., ME), the ALM can be applied to rapidly prepare the incineration bottom ash samples as well as other environmental samples for on-site determination of heavy metals and metalloids.


Asunto(s)
Ceniza del Carbón/química , Monitoreo del Ambiente/métodos , Metaloides/análisis , Metales Pesados/análisis , Sonicación/métodos , Espectrometría de Masas , Metaloides/química , Metales Pesados/química , Factores de Tiempo
5.
Biomed Microdevices ; 16(2): 269-75, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24288016

RESUMEN

This paper reports a lab-on-a-chip for the detection of Sarin nerve agent based on rapid electrochemical detection. The chemical warfare agent Sarin (C4H10FO2P, O-isopropyl methylphosphonofluoridate) is a highly toxic organophosphate that induces rapid respiratory depression, seizures and death within minutes of inhalation. As purified Sarin is colourless, odourless, water soluble and a easily disseminated nerve agent, it has been used as a weapon in terrorist or military attacks. To ascertain whether potable water supplies have been adulterated with this extremely potent poison, an inexpensive, sensitive and easy to use portable test kit would be of interest to first responders investigating such attacks. We report here an amperometric-based approach for detecting trace amounts of Sarin in water samples using a screen-printed electrode (SPE) integrated in a microfluidic chip. Enzymatic inhibition was obtained by exposing the immobilised biosensor in the microfluidic platform to Sarin in water samples. With the aid of cobalt phthalocyanine modified SPE, the device could detect Sarin at part-per-billion levels with concentration as low as 1 nM. The detection method reported here represents a significant improvement over the authors'previous optical-based detection method.


Asunto(s)
Sustancias para la Guerra Química/análisis , Técnicas Electroquímicas , Indoles/química , Dispositivos Laboratorio en un Chip , Sarín/análisis , Técnicas Electroquímicas/instrumentación , Técnicas Electroquímicas/métodos , Isoindoles , Sensibilidad y Especificidad
6.
Micromachines (Basel) ; 11(7)2020 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-32610583

RESUMEN

Micromixers are critical components in the lab-on-a-chip or micro total analysis systems technology found in micro-electro-mechanical systems. In general, the mixing performance of the micromixers is determined by characterising the mixing time of a system, for example the time or number of circulations and vibrations guided by tracers (i.e., fluorescent dyes). Our previous study showed that the mixing performance could be detected solely from the electrical measurement. In this paper, we employ electromagnetic micromixers to investigate the correlation between electrical and mechanical behaviours in the mixer system. This work contemplates the "anti-reciprocity" concept by providing a theoretical insight into the measurement of the mixer system; the work explains the data interdependence between the electrical point impedance (voltage per unit current) and the mechanical velocity. This study puts the electromagnetic micromixer theory on a firm theoretical and empirical basis.

7.
Drug Discov Today ; 23(4): 815-829, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29357288

RESUMEN

Microfluidic platforms have recently become popular as in vitro models because of their superiority in recapitulating microenvironments compared with conventional in vitro models. By providing various biochemical and biomechanical cues, healthy and diseased models at the organ level can be applied to disease progression and treatment studies. Microfluidic technologies are especially suitable for modeling biological barriers because the flow in the microchannels mimics the blood flow and body fluids at the interfaces of crucial organs, such as lung, intestine, liver, kidney, brain, and skin. These barriers have similar structures and can be studied with similar approaches for the testing of pharmaceutical compounds. Here, we review recent developments in microfluidic platforms for modeling biological barriers in the circulatory system.


Asunto(s)
Sistema Cardiovascular/fisiopatología , Técnicas Analíticas Microfluídicas/métodos , Microfluídica/métodos , Animales , Biomimética/métodos , Humanos , Modelos Biológicos
8.
J Colloid Interface Sci ; 311(2): 609-18, 2007 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-17434175

RESUMEN

A lattice Boltzmann method-based single-phase free surface model is developed to study the interfacial dynamics of coalescence, droplet formation and detachment phenomena related to surface tension and wetting effects. Compared with the conventional multiphase models, the lattice Boltzmann-based single-phase model has a higher computational efficiency since it is not necessary to simulate the motion of the gas phase. A perturbation, which is given in the same fashion as the perturbation step in Gunstensen's color model, is added to the distribution functions of the interface cells for incorporating the surface tension into the single-phase model. The assignment of different mass gradients along the fluid-wall interface is used to model the wetting properties of the solid surface. Implementations of the model are demonstrated for simulating the processes of the droplet coalescence, the droplet formation and detachment from ceiling and from nozzles with different shapes and different wall wetting properties.


Asunto(s)
Microfluídica , Modelos Químicos , Simulación por Computador , Modelos Estadísticos , Tensión Superficial , Humectabilidad
9.
Macromol Biosci ; 17(4)2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-27892655

RESUMEN

Fabrication of tissue engineering scaffolds with the use of novel 3D printing has gained lot of attention, however systematic investigation of biomaterials for 3D printing have not been widely explored. In this report, well-defined structures of polycaprolactone (PCL) and PCL- carbon nanotube (PCL-CNT) composite scaffolds have been designed and fabricated using a 3D printer. Conditions for 3D printing has been optimized while the effects of varying CNT percentages with PCL matrix on the thermal, mechanical and biological properties of the printed scaffolds are studied. Raman spectroscopy is used to characterise the functionalized CNTs and its interactions with PCL matrix. Mechanical properties of the composites are characterised using nanoindentation. Maximum peak load, elastic modulus and hardness increases with increasing CNT content. Differential scanning calorimetry (DSC) studies reveal the thermal and crystalline behaviour of PCL and its CNT composites. Biodegradation studies are performed in Pseudomonas Lipase enzymatic media, showing its specificity and effect on degradation rate. Cell imaging and viability studies of H9c2 cells from rat origin on the scaffolds are performed using fluorescence imaging and MTT assay, respectively. PCL and its CNT composites are able to show cell proliferation and have the potential to be used in cardiac tissue engineering.


Asunto(s)
Corazón/fisiología , Nanocompuestos/química , Nanotubos de Carbono/química , Poliésteres/farmacología , Impresión Tridimensional , Ingeniería de Tejidos/métodos , Andamios del Tejido/química , Animales , Rastreo Diferencial de Calorimetría , Muerte Celular/efectos de los fármacos , Conductividad Eléctrica , Corazón/efectos de los fármacos , Lipasa/metabolismo , Ensayo de Materiales , Microscopía Fluorescente , Mioblastos/citología , Mioblastos/efectos de los fármacos , Imagen Óptica , Ratas , Espectrometría Raman , Temperatura
10.
Biomicrofluidics ; 10(2): 024110, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27042252

RESUMEN

Blood plasma contains biomarkers and substances that indicate the physiological state of an organism, and it can be used to diagnose various diseases or body condition. To improve the accuracy of diagnostic test, it is required to obtain the high purity of blood plasma. This paper presents a low-cost, disposable microfluidics device for blood plasma extraction using magnetophoretic behaviors of blood cells. This device uses alternating magnetophoretic capture modes to trap and separate paramagnetic and diamagnetic cells away from blood plasma. The device system is composed of two parts, a disposable microfluidics chip and a non-disposable (reusable) magnetic field source. Such modularized device helps the structure of the disposable part dramatically simplified, which is beneficial for low-cost mass production. A series of numerical simulation and parametric study have been performed to describe the mechanism of blood cell separation in the microchannel, and the results are discussed. Furthermore, experimental feasibility test has been carried out in order to demonstrate the blood plasma extraction process of the proposed device. In this experiment, pure blood plasma has been successfully extracted with yield of 21.933% from 75 µl 1:10 dilution of deoxygenated blood.

11.
Lab Chip ; 15(18): 3627-37, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26237523

RESUMEN

The term "Lab-on-a-Chip," is synonymous with describing microfluidic devices with biomedical applications. Even though microfluidics have been developing rapidly over the past decade, the uptake rate in biological research has been slow. This could be due to the tedious process of fabricating a chip and the absence of a "killer application" that would outperform existing traditional methods. In recent years, three dimensional (3D) printing has been drawing much interest from the research community. It has the ability to make complex structures with high resolution. Moreover, the fast building time and ease of learning has simplified the fabrication process of microfluidic devices to a single step. This could possibly aid the field of microfluidics in finding its "killer application" that will lead to its acceptance by researchers, especially in the biomedical field. In this paper, a review is carried out of how 3D printing helps to improve the fabrication of microfluidic devices, the 3D printing technologies currently used for fabrication and the future of 3D printing in the field of microfluidics.


Asunto(s)
Dispositivos Laboratorio en un Chip , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Analíticas Microfluídicas/estadística & datos numéricos , Impresión Tridimensional/instrumentación
12.
Lab Chip ; 13(20): 4124-33, 2013 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-23969512

RESUMEN

There have been considerable efforts to engineer three-dimensional (3D) microfluidic environments to enhance cellular function over conventional two-dimensional (2D) cultures in microfluidic chips, but few involve topographical features, such as micro/nano-grooves, which are beneficial for cell types of cardiac, skeletal and neuronal lineages. Here we have developed a cost-effective and scalable method to incorporate micro-topographical cues into microfluidic chips to induce cell alignment. Using commercially available optical media as molds for replica molding, we produced large surface areas of polydimethylsiloxane (PDMS) micro-grooved substrates and plasma-bonded them to multiple microfluidic chips. Besides aligning a 2D monolayer of cells, the micro-grooved substrate can align 3D cellular constructs on chip. C2C12 mouse myoblasts were cultured three-dimensionally in a microfluidic chip with incorporated PDMS micro-grooved substrate remodeled into an aligned 3D cellular construct, where the actin cytoskeleton and nuclei were preferentially oriented along the micro-grooves. Cells within the 3D cellular constructs can align without being in direct contact with the micro-grooves due to synergism between topography and fluid shear stress. Aligned C2C12 3D cellular constructs showed enhanced differentiation into skeletal muscles as compared to randomly aligned ones. This novel method enables the routine inclusion of micro-topographical cues into 2D or 3D microfluidic cultures to generate relevant physiological models for studying tissue morphogenesis and drug screening applications.


Asunto(s)
Técnicas de Cultivo de Célula/métodos , Técnicas Analíticas Microfluídicas/métodos , Animales , Técnicas de Cultivo de Célula/economía , Diferenciación Celular , Línea Celular , Análisis Costo-Beneficio , Dimetilpolisiloxanos , Ratones , Técnicas Analíticas Microfluídicas/economía , Mioblastos/citología
13.
Biomaterials ; 34(21): 5078-87, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23601659

RESUMEN

Cell alignment by underlying topographical cues has been shown to affect important biological processes such as differentiation and functional maturation in vitro. However, the routine use of cell culture substrates with micro- or nano-topographies, such as grooves, is currently hampered by the high cost and specialized facilities required to produce these substrates. Here we present cost-effective commercially available optical media as substrates for aligning cells in culture. These optical media, including CD-R, DVD-R and optical grating, allow different cell types to attach and grow well on them. The physical dimension of the grooves in these optical media allowed cells to be aligned in confluent cell culture with maximal cell-cell interaction and these cell alignment affect the morphology and differentiation of cardiac (H9C2), skeletal muscle (C2C12) and neuronal (PC12) cell lines. The optical media is amenable to various chemical modifications with fibronectin, laminin and gelatin for culturing different cell types. These low-cost commercially available optical media can serve as scalable substrates for research or drug safety screening applications in industry scales.


Asunto(s)
Técnicas de Cultivo de Célula/métodos , Fenómenos Ópticos , Cemento de Policarboxilato/farmacología , Animales , Adhesión Celular/efectos de los fármacos , Diferenciación Celular/efectos de los fármacos , Línea Celular , Núcleo Celular/efectos de los fármacos , Núcleo Celular/metabolismo , Polaridad Celular/efectos de los fármacos , Proliferación Celular/efectos de los fármacos , Forma de la Célula/efectos de los fármacos , Discos Compactos , Módulo de Elasticidad/efectos de los fármacos , Ratones , Ratas , Propiedades de Superficie
14.
Lab Chip ; 13(12): 2405-13, 2013 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-23645079

RESUMEN

Fluorescence excitation enhancement by plasmonic nanostructures such as gold nanohole arrays has been a hot topic in biosensing and bioimaging in recent years. However, the high throughput and high yield fabrication of precisely designed metal nanostructures for optimized fluorescence excitation remains a challenge. Our work is the first report combining nanopattern nickel mould fabrication and UV imprinting for gold nanostructure mass fabrication in high yield. We report our successful gold nanohole array mass fabrication on a 4'' glass wafer, by first fabricating a high fidelity nickel mould, then using the mould for UV nanoimprinting on a polymer coated on the glass, evaporating the gold film on the glass wafer, and lifting off the polymer to obtain a gold nanohole array on the glass. Our optimized process for wafer fabrication can achieve almost 100% yield from nanoimprinting to gold lift-off, while the fabricated nickel mould has >70% defect-free area with the rest having a few scattered defects. In our work, the size and pitch of the gold nanohole array are designed to enhance the fluorescent dye Alexa 647. When the fabricated gold nanohole array is used for prostate specific antigen (PSA) detection by establishing a sandwiched fluorescence assay on the gold surface, a detection limit of 100 pg ml(-1) is achieved, while with a same thickness of gold film, only 1 ng ml(-1) is detected.


Asunto(s)
Biomarcadores/análisis , Oro/química , Inmunoensayo , Nanoestructuras/química , Colorantes Fluorescentes/química , Humanos , Masculino , Níquel/química , Antígeno Prostático Específico/análisis
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda