Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Electrocardiol ; 74: 122-127, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36183522

RESUMEN

BACKGROUND: Hypertrophic cardiomyopathy (HCM), a disease with myocardial fibrosis manifestation, is a common cause of sudden cardiac death (SCD) due to ventricular arrhythmias (VA). Current clinical risk stratification criteria are inadequate in identifying patients who are at risk for VA and in need of an implantable cardioverter defibrillator (ICD) for primary prevention. OBJECTIVE: We aimed to develop a risk prediction approach based on imaging biomarkers from the combination of late gadolinium contrast-enhanced (LGE) MRI and T1 mapping. We then aimed to compare the prediction to a virtual heart computational risk assessment approach based on LGE-T1 virtual heart models. METHODS: The methodology involved combining short-axis LGE-MRI with post-contrast T1 maps to define personalized thresholds for diffuse and dense fibrosis. The combined LGE-T1 maps were used to evaluate imaging biomarkers for VA risk prediction. The risk prediction capability of the biomarkers was compared with that of the LGE-T1 virtual heart arrhythmia inducibility simulation. VA risk prediction performance from both approaches was compared to clinical outcome (presence of clinical VA). RESULTS: Image-based biomarkers, including hypertrophy, signal intensity heterogeneity, and fibrotic border complexity, could not discriminate high vs low VA risk. LGE-T1 virtual heart technology outperformed all the image-based biomarker metrics and was statistically significant in predicting VA risk in HCM. CONCLUSIONS: We combined two MR imaging techniques to analyze imaging biomarkers in HCM. Raw and processed image-based biomarkers cannot discriminate patients with VA from those without VA. Hybrid LGE-T1 virtual heart models could correctly predict VA risk for this cohort and may improve SCD risk stratification to better identify HCM patients for primary preventative ICD implantation.


Asunto(s)
Cardiomiopatía Hipertrófica , Electrocardiografía , Humanos , Cardiomiopatía Hipertrófica/complicaciones , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Imagen por Resonancia Magnética , Tecnología
2.
Artículo en Inglés | MEDLINE | ID: mdl-38934970

RESUMEN

BACKGROUND: Ventricular tachycardia (VT), which can lead to sudden cardiac death, occurs frequently in patients after myocardial infarction. Radiofrequency catheter ablation (RFA) is a modestly effective treatment of VT, but it has limitations and risks. Cardiac magnetic resonance (CMR)-based heart digital twins have emerged as a useful tool for identifying VT circuits for RFA treatment planning. However, the CMR resolution used to reconstruct these digital twins may impact VT circuit predictions, leading to incorrect RFA treatment planning. OBJECTIVES: This study sought to predict RFA targets in the arrhythmogenic substrate using heart digital twins reconstructed from both clinical and high-resolution 2-dimensional CMR datasets and compare the predictions. METHODS: High-resolution (1.35 × 1.35 × 3 mm), or oversampled resolution (Ov-Res), short-axis late gadolinium-enhanced CMR was acquired by combining 2 subsequent clinical resolution (Clin-Res) (1.35 × 1.35 × 6 mm) short-axis late gadolinium-enhanced CMR scans from 6 post-myocardial infarction patients undergoing VT ablation and used to reconstruct a total of 3 digital twins (1 Ov-Res, 2 Clin-Res) for each patient. Rapid pacing was used to assess VT circuits and identify the optimal ablation targets in each digital twin. VT circuits predicted by the digital twins were compared with intraprocedural electroanatomic mapping data and used to identify emergent VT. RESULTS: The Ov-Res digital twins reduced partial volume effects and better predicted unique VT circuits compared with the Clin-Res digital twins (66.6% vs 54.5%; P < 0.01). Only the Ov-Res digital twin successfully identified emergent VT after a failed initial ablation. CONCLUSIONS: Digital twin infarct geometry and VT circuit predictions depend on the magnetic resonance resolution. Ov-Res digital twins better predict VT circuits and emergent VT, which may improve RFA outcomes.

3.
Elife ; 112022 01 25.
Artículo en Inglés | MEDLINE | ID: mdl-35076018

RESUMEN

Hypertrophic cardiomyopathy (HCM) is associated with risk of sudden cardiac death (SCD) due to ventricular arrhythmias (VAs) arising from the proliferation of fibrosis in the heart. Current clinical risk stratification criteria inadequately identify at-risk patients in need of primary prevention of VA. Here, we use mechanistic computational modeling of the heart to analyze how HCM-specific remodeling promotes arrhythmogenesis and to develop a personalized strategy to forecast risk of VAs in these patients. We combine contrast-enhanced cardiac magnetic resonance imaging and T1 mapping data to construct digital replicas of HCM patient hearts that represent the patient-specific distribution of focal and diffuse fibrosis and evaluate the substrate propensity to VA. Our analysis indicates that the presence of diffuse fibrosis, which is rarely assessed in these patients, increases arrhythmogenic propensity. In forecasting future VA events in HCM patients, the imaging-based computational heart approach achieved 84.6%, 76.9%, and 80.1% sensitivity, specificity, and accuracy, respectively, and significantly outperformed current clinical risk predictors. This novel VA risk assessment may have the potential to prevent SCD and help deploy primary prevention appropriately in HCM patients.


Asunto(s)
Cardiomiopatía Hipertrófica/diagnóstico por imagen , Simulación por Computador , Imagen por Resonancia Magnética , Taquicardia Ventricular/etiología , Adulto , Anciano , Cardiomiopatía Hipertrófica/complicaciones , Cardiomiopatía Hipertrófica/patología , Cardiomiopatía Hipertrófica/fisiopatología , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Femenino , Fibrosis , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Miocardio/patología , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/terapia , Adulto Joven
5.
Proc SPIE Int Soc Opt Eng ; 97892016 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-28649165

RESUMEN

Complex vascular anatomies can cause the failure of image-guided endovascular procedures. 3D printed patient-specific vascular phantoms provide clinicians and medical device companies the ability to preemptively plan surgical treatments, test the likelihood of device success, and determine potential operative setbacks. This research aims to present advanced mesh manipulation techniques of stereolithographic (STL) files segmented from medical imaging and post-print surface optimization to match physiological vascular flow resistance. For phantom design, we developed three mesh manipulation techniques. The first method allows outlet 3D mesh manipulations to merge superfluous vessels into a single junction, decreasing the number of flow outlets and making it feasible to include smaller vessels. Next we introduced Boolean operations to eliminate the need to manually merge mesh layers and eliminate errors of mesh self-intersections that previously occurred. Finally we optimize support addition to preserve the patient anatomical geometry. For post-print surface optimization, we investigated various solutions and methods to remove support material and smooth the inner vessel surface. Solutions of chloroform, alcohol and sodium hydroxide were used to process various phantoms and hydraulic resistance was measured and compared with values reported in literature. The newly mesh manipulation methods decrease the phantom design time by 30 - 80% and allow for rapid development of accurate vascular models. We have created 3D printed vascular models with vessel diameters less than 0.5 mm. The methods presented in this work could lead to shorter design time for patient specific phantoms and better physiological simulations.

6.
Proc SPIE Int Soc Opt Eng ; 97892016 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-28615797

RESUMEN

3D printing an anatomically accurate, functional flow loop phantom of a patient's cardiac vasculature was used to assist in the surgical planning of one of the first native transcatheter mitral valve replacement (TMVR) procedures. CTA scans were acquired from a patient about to undergo the first minimally-invasive native TMVR procedure at the Gates Vascular Institute in Buffalo, NY. A python scripting library, the Vascular Modeling Toolkit (VMTK), was used to segment the 3D geometry of the patient's cardiac chambers and mitral valve with severe stenosis, calcific in nature. A stereolithographic (STL) mesh was generated and AutoDesk Meshmixer was used to transform the vascular surface into a functioning closed flow loop. A Stratasys Objet 500 Connex3 multi-material printer was used to fabricate the phantom with distinguishable material features of the vasculature and calcified valve. The interventional team performed a mock procedure on the phantom, embedding valve cages in the model and imaging the phantom with a Toshiba Infinix INFX-8000V 5-axis C-arm bi-Plane angiography system. RESULTS: After performing the mock-procedure on the cardiac phantom, the cardiologists optimized their transapical surgical approach. The mitral valve stenosis and calcification were clearly visible. The phantom was used to inform the sizing of the valve to be implanted. CONCLUSION: With advances in image processing and 3D printing technology, it is possible to create realistic patient-specific phantoms which can act as a guide for the interventional team. Using 3D printed phantoms as a valve sizing method shows potential as a more informative technique than typical CTA reconstruction alone.

SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda