Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 71(7): 612-20, 2015 07.
Artículo en Japonés | MEDLINE | ID: mdl-26194435

RESUMEN

PURPOSE: A graph plot (GP) method using 123I-N-isopropyl-p-iodoamphetamine (123I-IMP) has been proposed as a simple and non-invasive estimation of quantitative cerebral bloodflow (CBF). A regression equation for the GP method was estimated by the data of resting state. Therefore, the accuracy of CBF values in high flow range may be an underestimated possibility in this method.The aim of this study was to formulate a new regression equation for the GP method by the data of resting state and acetazolamide (ACZ) challenge, and to clarify the accuracy of it. METHODS: The images of 26 consecutive patients who underwent both 123I-IMP chest radioisotope-angiography (RIA) and single photon emission computed tomography (SPECT) examinations were used to construct the new regression equation. Examinations of the resting state and ACZ challenge were performed in different days. All patients were analyzed by both the GP method and autoradiography (ARG) method which is the conventional examination with the one-point arterial blood sampling. A linear regression equation between the index of the input function was obtained by the GP method and CBF value of ARG. The linear regression equation based on the resting data was compared with the equation based on the resting and ACZ challenge (rest+stress) data. RESULTS: Goodliner correlation was obtained between the index of the input function obtained by the GP method and CBF value of the ARG method in the rest+stress state (y=2.75x+15.1, r=0.78). In contrast, correlation results between the index of the input function obtained by the GP method and CBF value of the ARG method in the resting state was expressed as y=2.28x+18.4, r=0.54 rCBF values based on the resting data was 20% underestimated in the high flow range compared with values based on the rest+stress data. CONCLUSION: The new linear regression equation for the GP method is useful for clinical study. Key words: non-invasive cerebral blood flow measurement method, graph plot (GP), autoradiography (ARG), 123I-N-isopropyl-p-iodoamphetamine (123I-IMP).


Asunto(s)
Circulación Cerebrovascular , Radioisótopos de Yodo , Yofetamina , Radiofármacos , Reología/métodos , Tomografía Computarizada de Emisión de Fotón Único/métodos , Acetazolamida , Adulto , Anciano , Autorradiografía/métodos , Femenino , Humanos , Modelos Lineales , Masculino , Persona de Mediana Edad
2.
Asia Ocean J Nucl Med Biol ; 6(1): 50-56, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29333467

RESUMEN

OBJECTIVES: We developed a simple non-invasive I-123-N-isopropyl-p-iodoamphetamine (123I-IMP) quantification method by analyzing chest RI-angiography and single photon emission computed tomography (SPECT) images based on the microsphere model (SIMS method). Theoretically, the SIMS method could be changed to the simple non-invasive ARG (SIARG) method by modifying the integrated washout ratio (WR) to one-point WR. If the regional cerebral blood flow (rCBF) values derived from the SIARG and ARG methods correlate well, the facilities employing the ARG method can easily switch to the SIARG method. The purpose of this study was to develop the SIARG method by modifying the SIMS method, and to confirm the feasibility of this method. METHODS: The correlation between the input counts of the SIARG method and the blood counts was determined by linear regression analysis. The rCBF values determined by the SIARG method were compared with the values obtained with the ARG and SIMS methods. RESULTS: There was a good linear correlation between the SIARG counts and the arterial blood counts obtained by the ARG method (r=0.85, P<0.001, n=29). The rCBF values obtained by the ARG and SIARG methods (n=29, 696 ROIs) correlated well (y=1.01x - 3.6, r=0.85, P<0.001). Similarly, the rCBF values obtained by the SIARG and SIMS methods (n=29, 696 ROIs) correlated well (y=0.98x - 15.2, r=0.90, P<0.001). rCBF values obtained by the SIARG method were almost the same as the values obtained by the ARG method, and values of the SIMS method were 15 ml/100g/min higher that of those obtained by the SIARG method. CONCLUSION: The rCBF values obtained by the ARG, SIARG, and SIMS methods correlated very well. Therefore, the SIARG method is potentially useful for examinations in routine clinical practice.

3.
Ann Nucl Med ; 30(3): 242-9, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26733060

RESUMEN

OBJECTIVE: In clinical practice, measurement of the rCBF has mainly been conducted by I-123-N-isopropyl-p-iodoamphetamine ((123)I-IMP) SPECT using the microsphere (MS) method, with continuous arterial blood sampling. While several non-invasive (123)I-IMP quantification methods have been developed, their accuracy has been shown to be lower than that of the MS method. Therefore, a non-invasive quantification method for use in routine clinical practice is being sought. The purpose of this study was to develop a simple non-invasive (123)I-IMP quantification method (SIMS method) with a simple input function-determining protocol based on the MS method. METHOD: The input function for the SIMS method was determined using the administered dose and the integrated lung washout ratio obtained by analyzing the count-time activity curve of the pulmonary artery and lung on dynamic chest images. The mean CBF (mCBF) and input function measured in 80 patients by the SIMS method was compared with those determined using the MS method. RESULT: A good correlation was observed between the counts measured by continuous arterial blood sampling in the MS method and the estimated counts by image analysis in the new method (r = 0.94, p < 0.01). Similarly, a good correlation was observed between the mCBF values determined by the MS method and the SIMS method (r = 0.83, p < 0.01). CONCLUSION: The mCBF values determined by the SIMS method were closely consistent with the values obtained by the MS method. This finding indicates the possibility of use of the SIMS method for routine clinical study.


Asunto(s)
Circulación Cerebrovascular , Yofetamina , Microesferas , Tomografía Computarizada de Emisión de Fotón Único/métodos , Anciano , Humanos , Persona de Mediana Edad , Estudios Retrospectivos
4.
Phys Med ; 32(9): 1180-5, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27601249

RESUMEN

We recently developed a simple noninvasive (123)I-IMP microsphere (SIMS) method using chest dynamic planar images and brain single photon emission computed tomography. The SIMS method is an automatic analysis method, except for the process of setting the region of interest (ROI) of the input function. If a fully automatic ROI setting algorithm can be developed to determine the input function for the SIMS method, repeatability and reproducibility of the analysis of regional cerebral blood flow (rCBF) of the SIMS method can be guaranteed. The purpose of this study is to develop a fully automatic input function determination program for the SIMS method and to confirm the clinical usefulness of this program. The automatic input function determination program consists of two ROI setting programs for the PA and lung regions, and it is developed using the image phase analysis of a chest RI angiogram. To confirm the clinical usefulness of this program, the rCBF in 34 patients measured using the automatic method were compared with the values obtained through the manual setting method. Input functions by the automatic and manual methods were approximately equal. A good correlation was observed between the rCBF values obtained by the automatic method and those obtained by the manual setting method (r=0.96, p<0.01). Further, the total time taken for the automatic SIMS analysis is 1-2min as compared to 20-30min for the current analysis, and therefore, this technique contributes to the improvement of the throughput of nuclear medical examinations.


Asunto(s)
Circulación Cerebrovascular , Procesamiento de Imagen Asistido por Computador/métodos , Inosina Monofosfato/química , Radioisótopos de Yodo/química , Tomografía Computarizada de Emisión de Fotón Único , Anciano , Angiografía , Área Bajo la Curva , Automatización , Femenino , Humanos , Pulmón/diagnóstico por imagen , Masculino , Microesferas , Persona de Mediana Edad , Reconocimiento de Normas Patrones Automatizadas , Arteria Pulmonar/diagnóstico por imagen , Radiofármacos , Análisis de Regresión , Reproducibilidad de los Resultados
5.
Asia Ocean J Nucl Med Biol ; 3(2): 77-82, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-27408886

RESUMEN

OBJECTIVES: Improved brain uptake ratio (IBUR), employing (99m)Tc-ethyl cysteinate dimer ((99m)Tc-ECD), is an automatic non-invasive method for quantitatively measuring regional cerebral blood flow (rCBF). This method was developed by the reconstruction of the theory and linear regression equation, based on rCBF measurement by H2 (15)O positron emission tomography. Clarification of differences in rCBF values obtained by Patlak plot (PP) and IBUR method is important for clinical diagnosis during the transition period between these methods. Our purpose in this study was to demonstrate the relationship between rCBF values obtained by IBUR and PP methods and to evaluate the clinical applicability of IBUR method. METHODS: The mean CBF (mCBF) and rCBF values in 15 patients were obtained using the IBUR method and compared with PP method values. RESULTS: Overall, mCBF and rCBF values, obtained using these independent techniques, were found to be correlated (r=0.68). The mCBF values obtained by the IBUR method ranged from 18.9 to 44.9 ml/100g/min, whereas those obtained by the PP method ranged from 34.7 to 48.1 ml/100g/min. The rCBF values obtained by the IBUR method ranged from 16.3 to 60.2 ml/100g/min, whereas those obtained by the PP method were within the range of 26.7-58.8 ml/100g/min. CONCLUSION: The ranges of mCBF and rCBF values, obtained by the IBUR method, were approximately 60% lower than those obtained by the PP method; therefore, this method can be useful for diagnosing lower flow area. Re-analysis of prior PP data, using the IBUR method, could be potentially useful for the clinical follow-up of rCBF.

6.
Phys Med ; 30(4): 513-20, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24491399

RESUMEN

Non-invasive quantitative measurements are useful for clinical study as these are simple and pain-free procedures. A new non-invasive semi-automatic quantitative measurement method, the improved brain uptake ratio (IBUR) method using (99m)Tc-ECD SPECT, has recently been reported. If an automatic ROI setting algorithm could be developed to determine the input function for the IBUR method, analysis of regional cerebral blood flow (rCBF) can be completed within a few min without recourse to complex techniques, through a fully automatic rCBF analysis program. The purpose of this study was to develop an automatic input function determination program for (99m)Tc-ECD non-invasive cerebral blood flow quantification and to confirm the feasibility of use of this program. The images of 15 consecutive patients who underwent both (99m)Tc-ECD chest RI angiography and SPECT examinations were used for development of the automatic arterial input function program. The images of 69 consecutive patients were used for validation of the program. The coincidence ratio between the ROI automatic method and the manual setting method was 98%. The mean difference in the ROI location was ±6.4 mm in the X direction and ±8.6 mm in the Y direction. Individual rCBF values obtained using these independent techniques were also reasonably well correlated (r = 0.95). The total time for the IBUR analysis using the automatic method is 2-3 min as compared to 20-30 min for the current analysis method. This technique improves the throughput of nuclear medical examinations.


Asunto(s)
Circulación Cerebrovascular , Cisteína/análogos & derivados , Compuestos de Organotecnecio , Imagen de Perfusión/métodos , Tomografía Computarizada de Emisión de Fotón Único/métodos , Adulto , Anciano , Aorta/diagnóstico por imagen , Aorta/fisiología , Automatización , Estudios de Factibilidad , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda