Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Diagnostics (Basel) ; 13(3)2023 Jan 27.
Artículo en Inglés | MEDLINE | ID: mdl-36766568

RESUMEN

The aim of this study was to evaluate the relationship between skeletal sagittal nasal profile morphology and sagittal skeletal malocclusions. Regarding lateral cephalometric films, the study was conducted in a total of 135 individuals without any prior orthodontic treatment (mean age of 17.91 ± 1.91), including 49 males (mean age 17.91 ± 1.16) and 86 females (mean age 17.78 ± 1.91 years). The groups were divided into two groups as male and female according to gender, and three groups as skeletal Class 1, Class 2, and Class 3 according to the Steiner's ANB angle. In addition, skeletal groups were compared within groups by dividing into two groups of male and female. A total of eight parameters, three skeletal sagittal angular (SNA, SNB, and ANB angles), four nasal linear (R-A, N-A, N-ANS, and N-R distances) and one nasal angular (N1-N2/N2-R angle), were measured on each cephalometric film. The arithmetic mean and standard deviation of all measured nasal parameters were calculated. For statistical analysis, independent sample t-test and one-way analysis of variance (One-Way ANOVA) were used for normally distributed data, and Mann Whitney U and Kruskal Wallis tests were used for data that did not show normal distribution. For statistical analysis, p < 0.05 was considered significant. R-A, N-A, and N-ANS linear nasal parameters differed significantly between the male and female groups, which were evaluated regardless of the skeletal groups, with a higher rate in males (p < 0.05). N-R linear nasal parameter showed a statistically significant difference between skeletal malocclusion groups, which were evaluated regardless of gender. N-R distance was found to be significantly longer in skeletal Class 3 individuals than in Class 1 and 2 individuals (p < 0.05). There was no statistically significant difference in nasal bone concavity angle in all groups (p > 0.05). R-A and N-A linear nasal parameters showed statistically significant differences between male and female sex groups in all skeletal malocclusion classes (p < 0.05). At first, results showed that males had longer measurements than females in all linear nasal parameters. Second, longer measurements were found in all linear nasal parameters in skeletal Class 3 individuals than those in skeletal Class 1 and Class 2 individuals. Third, the nasal bone concavity angle was greater in skeletal Class 2 individuals than the others.

2.
Materials (Basel) ; 16(2)2023 Jan 11.
Artículo en Inglés | MEDLINE | ID: mdl-36676460

RESUMEN

Bracket failure is one of the most important problems encountered during fixed orthodontic treatment. For this reason, different types of adhesive agents have been developed over the years. Consequently, the aim of this study was to evaluate the shear bond strength of brackets bonded to teeth etched with a conventional acid etching method in a laboratory environment by using different types of adhesive agents and comparing the number of shear strokes. Sixty human maxillary premolars were divided into three groups and Gemini stainless steel metal brackets (3M Unitek, Monrovia, CA, USA) were bonded to all teeth. In Group 1, Transbond™ XT Primer (3M Unitek, Monrovia, CA, USA) and Transbond™ XT Light Cure Adhesive Paste composite (3M Unitek, Monrovia, CA, USA) were used. In Group 2, BracePaste® MTP Primer (American Orthodontics, Sheboygan, CA, USA) and BracePaste® Adhesive composite (American Orthodontics, Sheboygan, WI, USA) were used. In Group 3, Ortho Solo™ Primer (Ormco, Orange, CA, USA) and Grengloo™ Adhesive composite (Ormco, Brea, CA, USA) were used. The samples were subjected to a shear test with a closed-loop controlled, low-cycle fatigue machine with a capacity of 10 N and a crosshead speed of 300 mm/min. The number of shear strokes of the brackets was recorded. According to the Kruskal−Wallis and Mann−Whitney U tests performed on the data obtained, statistically significant differences were found between the groups in terms of the numbers of shear strokes (p < 0.05). Significantly higher numbers of shear strokes and higher shear bond strengths were observed in Group 3 compared with Group 1 and Group 2 (p < 0.05). There was no statistically significant difference between the numbers of shear strokes for Group 1 and Group 2 samples (p > 0.05). To conclude the study, it was observed that the type of adhesive used had an effect on the bond strength of the bracket and that the Grengloo™ adhesive agent showed higher shear bond strength. It was observed that BracePaste® Adhesive and Transbond™ XT Light Cure Adhesive Paste adhesive agents had similar shear bond strengths.

3.
Materials (Basel) ; 16(3)2023 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-36769990

RESUMEN

The aim of this study was to compare the demineralizations of the enamel surfaces around different types of orthodontic brackets in an artificial cariogenic environment. A total of 90 extracted human maxillary first premolar teeth were used in this in vitro study. The teeth were divided into 6 groups, 5 study and 1 control, each consisting of 15 samples. Victory metal, Gemini metal, Clarity self-ligating ceramic, APC Clarity Advanced ceramic and Clarity Advanced ceramic brackets (3M Unitek, Monrovia, Calif) used in the study groups were bonded to the teeth with the direct technique. The gingival, occlusal and proximal enamel surfaces adjacent to the brackets were measured with a DIAGNOdent pen (KaVo, Biberach, Germany) (T0). Then, the teeth were placed in a cariogenic suspension environment containing Streptococcus mutans, sucrose and artificial saliva. The teeth were removed from the cariogenic suspension at the end of 28 days. Enamel surfaces were remeasured with DIAGNOdent and the values were recorded (T1). Whether the obtained data were homogeneously distributed or not was determined by the Kolmogorov-Smirnov test, within-group comparisons were performed with the Wilcoxon test, and between-group comparisons were performed with Mann-Whitney U and Kruskal-Wallis tests. Significance level was accepted as p < 0.05. In all groups, the demineralization values of the enamel surfaces in the gingival, proximal and occlusal surfaces adjacent to the brackets were significantly higher in the T1 period than in the T0 period (p < 0.05). In the T1 period of Gemini metal, Clarity self-ligating ceramic and Clarity advanced ceramic bracket groups, the demineralization values of the proximal enamel surfaces were found to be significantly higher than the Victory metal and APC Clarity Advanced ceramic bracket groups (p < 0.05). In the T1 period, the demineralization values of the occlusal enamel surfaces of the Victory metal, APC Clarity Advanced ceramic bracket groups and control group were significantly lower than the Gemini metal, Clarity self-ligating ceramic and Clarity Advanced ceramic bracket groups (p < 0.05). Significant increases in enamel demineralization values were observed as a consequence of increased retention areas for microbial dental plaque on enamel surfaces adjacent to the bracket. Considering the importance of minimizing enamel demineralization in fixed orthodontic treatments, less enamel demineralization in Victory metal and APC Clarity Advanced ceramic bracket groups showed that these brackets can be preferred in patients with poor oral hygiene.

4.
J Adhes Dent ; 12(2): 117-22, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20157670

RESUMEN

PURPOSE: To determine the effects of thermocycling on shear bond strengths (SBSs) of a self-etching primer (SEP)after 10,000 and 20,000 thermal cycles. The tested hypothesis was that 10,000 and 20,000 thermal cycles would affect the bond strength of metal brackets bonded to enamel with the self-etching primer. MATERIALS AND METHODS: Brackets were bonded to bovine incisors with two etching protocols. In group CM (conventional method), teeth were etched with 37% phosphoric acid for 30 s. In group SEP, a self-etching primer (Transbond Plus, 3M Unitek) was applied. Brackets were bonded with light-curing adhesive (Transbond XT, 3M Unitek). The SBSs were determined after water storage at 370°C for 24 h, after 10,000 and 20,000 cycles of thermocycling. RESULTS: For both groups (CM and SEP), SBSs decreased with 10,000 and 20,000 thermal cycles. These decreased SBSs were significantly different from the values obtained with no thermocycling. Highest SBSs were observed with no thermocycling for groups CM and SEP (18.6 and 18.0 MPa, respectively). These values were not statistically different from each other. Lowest SBSs were obtained with 10,000 and 20,000 thermal cycles for group SEP (14.2 and 14.7 MPa, respectively). These values were significantly different from all other SBSs. CONCLUSION: This study indicates that the SEP (Transbond Plus) provides clinically acceptable bond strength values compared with the conventional method after 10,000 and 20,000 thermal cycles.


Asunto(s)
Grabado Ácido Dental/métodos , Recubrimiento Dental Adhesivo , Análisis del Estrés Dental , Soportes Ortodóncicos , Cementos de Resina , Animales , Bovinos , Desconsolidación Dental , Esmalte Dental , Calor , Ensayo de Materiales , Ácidos Fosfóricos , Distribución Aleatoria , Resistencia al Corte
5.
Materials (Basel) ; 13(19)2020 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-32992817

RESUMEN

Based on the development of many adhesive systems and bonding techniques, bonding strength of orthodontic brackets has become even more important in modern clinical orthodontics. The aim of this study was to determine mean shearing stroke frequency of different orthodontic bracket types and bonding agents under cycling loading. Therefore, 10 different types of orthodontic bracket from 4 different brands were divided into 2 groups. Two different adhesives, namely Transbond™ XT etch-and-rinse for Group 1 and Transbond™ Plus self-etching-primer adhesive for Group 2 were considered. The brackets were tested under cycling loading force of 10-N and a crosshead speed of 300 mm/min and 40 cycle/min. The frequency of strokes that the brackets failed were determined and these data were analyzed by statistical analysis using an independent sample t-test and one-way analysis of variance (ANOVA). The level of significance was set at p < 0.05. Generally, differences between the frequency of shearing strokes of the bracket failures were found to be statistically significant depending on the type of adhesives and brackets (p < 0.05). The bonding technique for Group 1 was found to have a significantly higher shear bonding strength than Group 2. It is also seen that different types of bracket belonging to the same or different brands had different shear bonding strength. It may be concluded that: (i) all bracket types used in this study can be applied with both bonding techniques, (ii) in order to minimize the risk of hard tissue damage, ceramic brackets should be carefully bonded using the self-etching primary adhesive technique.

6.
Eur J Orthod ; 31(1): 84-9, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19164413

RESUMEN

The aim of this study was to compare the shear bond strength (SBS) and debonding characteristics of a polymer mesh base ceramic bracket bonded with two different surface conditioning methods. InVu Readi-Base ceramic brackets were bonded to 100 human premolars with different etching protocols. With conventional method (CM), the teeth were etched with 37 per cent phosphoric acid for 30 seconds, while Transbond Plus self-etching primer (SEP) was applied as recommended by the manufacturer. SBS testing was performed on 25 samples of each group while the remaining 25 samples of each group were subjected to plier or machine debonding after thermocycling for 1000 cycles. The adhesive remnant index (ARI) was used to determine the amount of composite resin on the enamel. Statistical analysis included Kruskal-Wallis and Mann-Whitney U-tests and Weibull analysis. No significant difference was observed between the CM (9.22 MPa) and SEP (9.04 MPa) groups (P=0.684). ARI scores of machine and plier debonding for both groups showed a significant difference (P

Asunto(s)
Grabado Ácido Dental/métodos , Cerámica/química , Recubrimiento Dental Adhesivo/métodos , Desconsolidación Dental , Materiales Dentales/química , Diseño de Aparato Ortodóncico , Soportes Ortodóncicos , Polímeros/química , Adhesividad , Desconsolidación Dental/instrumentación , Desconsolidación Dental/métodos , Esmalte Dental/ultraestructura , Falla de Equipo , Humanos , Ensayo de Materiales , Ácidos Fosfóricos/química , Cementos de Resina/química , Resistencia al Corte , Estrés Mecánico , Propiedades de Superficie , Temperatura
7.
Angle Orthod ; 78(2): 351-6, 2008 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-18251621

RESUMEN

OBJECTIVE: To determine the effects of thermocycling on shear bond strengths (SBSs) of a self-etching primer (SEP) after 0, 2000, and 5000 thermal cycles. MATERIALS AND METHODS: Brackets were bonded to bovine incisors with two etching protocols. In the control group (conventional method) teeth were etched with 37% phosphoric acid. In the experimental group, an SEP (Transbond Plus) was applied as recommended by the manufacturer. Brackets were bonded with light-cure adhesive paste (Transbond XT) and light cured for 20 seconds in both groups. The SBSs were measured after water storage at 37 degrees C for 24 hours, after 2000 and 5000 cycles of thermocycling between 5 degrees C and 55 degrees C. Bond failure location was determined with the Adhesive Remnant Index (ARI). RESULTS: In the control group, SBSs did not show any significant differences among 0, 2000, and 5000 thermal cycles. However, in group SEP, SBSs decreased with 2000 and 5000 thermal cycles, and these decreases were significantly different from no thermocyling (P < .001). A significant difference was observed between ARI scores of the control group with 5000 thermal cycles and group SEP with no thermal cycles (P < .003). In addition, a significant difference was found between group SEP with no thermocycling and with 5000 thermal cycles (P < .003). CONCLUSION: The results of this study indicate that the SEP (Transbond Plus) provides clinically acceptable bond strength values compared with the conventional method after thermocycling.


Asunto(s)
Recubrimiento Dental Adhesivo , Cementos de Resina , Animales , Bovinos , Análisis del Estrés Dental , Calor , Ensayo de Materiales , Resistencia al Corte
8.
Biomed Res Int ; 2018: 5434609, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29854764

RESUMEN

OBJECTIVE: The aim of this study is to present a new adjustable Cise space maintainer for preventive orthodontic applications. METHODS: Stainless steel based new design consists of six main components. In order to understand the major displacement and stress fields, structural analysis for the design is considered by using finite element method. RESULTS: Similar to major displacement at y-axis, critical stresses σx and τxy possess a linear distribution with constant increasing. Additionally, strain energy density (SED) plays an important role to determine critical biting load capacity. CONCLUSION: Structural analysis shows that the space maintainer is stable and is used for maintaining and/or regaining the space which arouses early loss of molar tooth.


Asunto(s)
Recubrimiento Dental Adhesivo/métodos , Resinas Compuestas/química , Análisis de Elementos Finitos , Humanos , Diente Molar/química , Soportes Ortodóncicos , Acero Inoxidable/química
9.
Angle Orthod ; 88(6): 733-739, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30124325

RESUMEN

OBJECTIVES:: To compare the extent of root resorption and the amount of tooth movement between continuous orthodontic force and intermittent orthodontic force that was activated in a similar way to a 4-week orthodontic adjustment period. MATERIALS AND METHODS:: Twenty-five patients who required the extraction of upper first premolars were recruited in this study. A buccally directed continuous force of 150 g was applied to the upper first premolar on one side for 15 weeks. A buccally directed intermittent force (28 days on, 7 days off) of the same magnitude was applied to the contralateral first premolar. The teeth were extracted at the end of the experimental period and processed for volumetric evaluations of resorption craters. The degree of tooth movement and rotation were measured on the study models. RESULTS:: Continuous force application displayed significantly higher root resorption volume than the intermittent force application ( P < .05), particularly on the buccal and lingual surfaces (P < .05) and the middle third of the root ( P < .01). There was more tipping and rotational movement in the continuous force group. CONCLUSIONS:: In a 4-week orthodontic adjustment period, intermittent force significantly reduced the amount of root resorption compared with continuous force. Although there was less degree of tooth movement with intermittent force, unwanted rotational movement was avoided. This is crucial in patients who are predisposed to orthodontically induced inflammatory root resorption, and the use of this intermittent regimen should be considered.


Asunto(s)
Resorción Radicular/diagnóstico por imagen , Técnicas de Movimiento Dental/efectos adversos , Adolescente , Diente Premolar/diagnóstico por imagen , Femenino , Humanos , Masculino , Radiografía Dental , Resorción Radicular/etiología , Extracción Dental , Técnicas de Movimiento Dental/métodos , Microtomografía por Rayos X
10.
Angle Orthod ; 77(5): 901-6, 2007 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-17902234

RESUMEN

OBJECTIVE: To evaluate shear bond strengths (SBSs) of a self-etching primer (SEP) following saliva contamination at different stages of bonding at debond times of 5, 15, and 30 minutes and 24 hours. MATERIALS AND METHODS: Two-hundred forty human premolars were divided into four groups: group 1, uncontaminated; group 2, saliva contamination after priming; group 3, saliva contamination before priming; and group 4, saliva contamination before and after priming. Four subgroups according to debond times of 5, 15, 30 minutes and 24 hours were composed. Metal brackets were bonded with an SEP (Transbond Plus) and light-cure adhesives paste (Transbond XT). SBS values and the adhesive remnants were determined. RESULTS: The highest SBS was obtained at a debond time of 24 hours for the control group. This was significantly different from the other groups. SBSs at 5, 15, and 30 minutes showed no significant difference from each other in the control group (P>.05). Lowest SBSs were obtained at a debond time of 5 minutes for groups 1, 2, 3, and 4 (8.38, 7.10, 7.06, and 6.26 MPa, respectively) and were not significantly different from each other (P>.05). SBSs at 24 hours were not significantly different from each other for groups 2, 3, and 4 (P>.05). Significant differences were found in the adhesive remnant (P<.001). CONCLUSIONS: SEP (Transbond Plus) may produce clinically acceptable bracket bonding after 5, 15, and 30 minutes from time of placement on the teeth, even with light and heavy saliva contamination.


Asunto(s)
Grabado Dental/métodos , Recubrimientos Dentinarios/química , Contaminación de Equipos , Cementos de Resina/química , Saliva , Análisis de Varianza , Distribución de Chi-Cuadrado , Desconsolidación Dental , Humanos , Soportes Ortodóncicos , Resistencia al Corte , Factores de Tiempo
11.
Biomed Res Int ; 2017: 3546262, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28377927

RESUMEN

Objective. The aim of this study is to evaluate the factors that affect wearing time and patient behavior during reverse pull headgear therapy with a newly designed reverse pull headgear. Methods. In clinical practice, new reverse pull headgears were applied to fifteen patients. The patients were monitored during reverse pull headgear therapy and the data were evaluated. Statistical analysis was made. Results. During the study, patients were monitored successfully and the evaluations showed that patients wear the new reverse pull headgears mostly at night. There are differences between days of week and hours of day. Weekends are more popular than weekdays for wearing reverse pull headgear. Conclusions. This new type of reverse pull headgears can be used successfully in clinical practice and can help the clinician. Study showed that the most important factor that affects the cooperation of reverse pull headgear patient is aesthetic appearance.


Asunto(s)
Aparatos de Tracción Extraoral , Maloclusión de Angle Clase III/terapia , Pacientes/psicología , Adolescente , Cefalometría , Niño , Femenino , Humanos , Masculino , Maloclusión de Angle Clase III/fisiopatología , Maloclusión de Angle Clase III/psicología
12.
Appl Bionics Biomech ; 2016: 5728382, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27528796

RESUMEN

The aim of this study is to present a new upper molar distalization appliance called Cise distalizer designed as intraoral device supported with orthodontic mini screw for upper permanent molar distalization. The new appliance consists of eight main components. In order to understand the optimum force level, the appliance under static loading is tested by using strain gage measurement techniques. Results show that one of the open coils produces approximately 300 gr distalization force. Cise distalizer can provide totally 600 gr distalization force. This range of force level is enough for distalization of upper first and second molar teeth.

13.
Eur J Dent ; 5(2): 210-214, 2011 04.
Artículo en Inglés | MEDLINE | ID: mdl-21494391

RESUMEN

Pulp stones are usually found in the pulp chamber. Radiographically, they appear as radiopaque structures in the pulp chambers or root canals of individual teeth. Generalized pulp stones throughout the dentition are usually associated with systemic or genetic disorders of the dentine. This report presents an unusual case of a 13-year-old girl with generalized pulp stones with clinically normal crowns. The patient's main complaint was a crossbite affecting all permanent canines. Radiographic examination revealed multiple pulp stones and several teeth with atypically shaped roots. Orthodontic treatment, gingivoplasty, and esthetic restorations were performed, thus using a multidisciplinary approach to establish functionally and esthetically sound dentition.

14.
Eur J Dent ; 4(2): 171-4, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20396449

RESUMEN

OBJECTIVES: To determine the color preferences for elastic ligatures among patients receiving fixed-appliance orthodontic therapy. METHODS: Five hundred patients with metal brackets (336 female patients and 164 male patients) were included, and their color preferences for elastic ligatures were recorded using a color scale. Chi-square analysis was performed to evaluate the color preferences and to determine the influence of age and gender on color preferences (P<.05). RESULTS: Two hundred and seventy-six patients (55.2%) preferred strikingly colorful elastic ligatures, while 224 patients (44.8%) preferred less noticeable elastic ligatures. No significant difference was observed between the color preferences of female and male patients (P>.05). However, significant differences were observed between the color preferences of adolescents and older patients (P<.001). CONCLUSIONS: Female patients preferred red-purple-colored tones, while male patients preferred blue-black-colored tones. Adolescents preferred colorful elastic ligatures, while older patients preferred ligatures with less-noticeable colors. A stock of 10-12 colorful and less-noticeable elastic ligatures seems to be adequate to ensure patient satisfaction.

SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda