1.
Eur Radiol ; 29(11): 5941-5949, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31041562

RESUMEN

OBJECTIVE: To evaluate feasibility and diagnostic performance of multi-level calcium suppression in spectral detector computed tomography (SDCT) for assessment of bone metastasis. MATERIALS AND METHODS: Retrospective IRB-approved study on 21 patients who underwent SDCT (120 kV, reference mAs 116) and MRI. Thoracic and lumbar vertebrae (n = 357) were included and categorized as normal (n = 133) or metastatic (n = 203) based on MRI (STIR, T1w, ±contrast). The multi-level virtual non-calcium (VNCa) algorithm computes dynamic soft tissue/calcium pairs allowing for computation of different suppression index levels to address inter-individual variance of prevalent calcium composition weights. We computed images with low, medium, and high calcium suppression indices and compared them with conventional images (VNCa_low/med/high and conventional images (CI)). For quantitative image analysis, regions of interest were placed in normal and metastatic bone. Two readers reviewed the datasets independently in multiple sessions. They determined the presence of vertebral metastases on a per vertebra basis using a binary scale. Statistic assessment was performed using ANOVA with Tukey HSD, Student's T test, and ROC analysis. RESULTS: Attenuation of both normal and metastatic bone was lower in VNCa images than that in conventional images (e.g., CI/VNCa_low, - 46.3 to 238.8 HU/343.3-60.2 HU; p ≤ 0.05). VNCa_low+med improved separation of normal and metastatic bone in ROC analysis (AUC, CI/VNCa_low/VNCa_med = 0.74/0.95/0.98; p ≤ 0.05). In subjective analysis, both sensitivity and specificity were clearly improved in VNCa_low as compared with CI (0.85/0.84 versus 0.78/0.82). Readers showed a good inter-rater reliability (kappa = 0.65). CONCLUSIONS: Multi-level VNCa reconstructed from SDCT improve quantitative separation of normal and metastatic bone and subjective determination of bone metastases when using low to intermediate calcium suppression indices. KEY POINTS: • Spectral detector CT allows for multi-level calcium suppression in CT images and low and medium calcium suppression indices improved separation of normal and metastatic bone. • Thus, multi-level calcium suppression allows to optimize image contrast in regard to dedicated pathologies. • Low-level virtual non-calcium images (index 25-50) improved diagnostic performance regarding detection of metastasis.


Asunto(s)
Enfermedades de la Médula Ósea/diagnóstico por imagen , Calcio , Neoplasias de la Columna Vertebral/secundario , Tomografía Computarizada por Rayos X/métodos , Adulto , Algoritmos , Médula Ósea/diagnóstico por imagen , Métodos Epidemiológicos , Femenino , Humanos , Vértebras Lumbares/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Neoplasias de la Columna Vertebral/diagnóstico por imagen , Vértebras Torácicas/diagnóstico por imagen
3.
Sci Rep ; 13(1): 11431, 2023 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-37454162

RESUMEN

To assess ischaemic penumbra through the post-processing of the spectral multiphasic CT Angiography (mCTA) data in acute ischaemic stroke (AIS) patients. Thirty one consecutive patients strongly suspected of severe Middle Cerebral Artery AIS presenting less than 6 h after onset of symptoms or with unknown time of onset of symptoms underwent a standardized CT protocol in spectral mode including Non Contrast CT, mCTA, and Perfusion CT (CTP) on a dual-layer MDCT system. Areas disclosing delayed enhancement on iodine density (ID) maps were highlighted by subtraction of the serial mCTA datasets. Two neuroradiologists independently rated the correspondence between delayed enhancing areas at mCTA and the penumbral/infarcted areas delineated by two validated CTP applications using a 5-levels scoring scale. Interobserver agreement between observers was evaluated by kappa statistics. Dose delivery was recorded for each acquisition. Averaged correspondence score between penumbra delineation using subtracted mCTA-derived ID maps and CTP ones was 2.76 for one application and 2.9 for the other with best interobserver agreement kappa value at 0.59. All 6 stroke mimics out of the 31 patients' cohort were correctly identified. Average dose delivery was 7.55 mSv for the whole procedure of which CTP accounted for 39.7%. Post-processing of spectral mCTA data could allow clinically relevant assessment of the presence or absence of ischaemic penumbra in AIS-suspected patients if results of this proof-of-concept study should be confirmed in larger patients'series.


Asunto(s)
Isquemia Encefálica , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Humanos , Accidente Cerebrovascular/diagnóstico por imagen , Isquemia Encefálica/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Infarto de la Arteria Cerebral Media , Angiografía Cerebral/métodos , Encéfalo/diagnóstico por imagen
4.
Eur J Radiol ; 159: 110681, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36592582

RESUMEN

PURPOSE: To evaluate the clinical applicability of a prototype virtual non-contrast (VNC) reconstruction algorithm based on coronary CT angiography (cCTA) to assess calcified coronary plaques by calcium scoring (CACS). METHODS: Eighty consecutive patients suspected of coronary artery disease were retrospectively included. All patients underwent a cardiac CT using a dual-layer spectral-detector CT system. The standardized acquisition protocol included unenhanced CACS and cCTA. Datasets were acquired using 120 keV. VNC-reconstructions were calculated from the cCTA images at 2.5 mm (VNC group 1), 2.5 of 0.9 mm (group 2), and 0.9 mm (group 3) slice thickness. We compared the Agatston score and Coronary Artery Calcium Data and Reporting System (CAC-DRS) of all VNC reconstructions with the true non-contrast (TNC)-dataset as the gold standard. RESULTS: In total, 73 patients were evaluated. Fifty patients (68.5 %) had a CACS > 0 based on TNC. We found a significant difference in the Agatston score comparing all VNC-reconstructions (1: 1.35, 2: 3.7, 3: 10.4) with the TNC dataset (3.8) (p < 0.001). Correlation analysis of the datasets showed an excellent correlation of the TNC results with the different VNC-reconstructions (r = 0.904-0.974, p < 0.001) with a slope of 1.89-2.53. Mean differences and limits of agreement by Bland-Altman analysis between TNC and group 1 were 83 and -196 to 362, respectively. By using the VNC-reconstructions, in group 1 23 patients (31.5 %), in group 2 10 (13.7 %), and in group 3 23 (31.5 %) were reclassified according to CAC-DRS compared to TNC. Classification according to CAC-DRS revealed a significant difference between TNC and group 1 (p = 0.024) and no significance compared to groups 2 and 3 (p = 0.670 and 0.273). CONCLUSION: The investigated VNC reconstruction algorithm of routine cCTA allows the detection and evaluation of coronary calcium burden without the requirement for an additional acquisition of an unenhanced CT scan for CACS and, therefore, a reduction of radiation exposure.


Asunto(s)
Calcio , Tomografía Computarizada por Rayos X , Humanos , Calcio/análisis , Estudios Retrospectivos , Estudios de Factibilidad , Tomografía Computarizada por Rayos X/métodos , Angiografía Coronaria/métodos
5.
Abdom Radiol (NY) ; 43(8): 2066-2074, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29185013

RESUMEN

PURPOSE: To investigate a benefit from virtual monoenergetic reconstructions (VMIs) for assessment of arterially hyper-enhancing liver lesions in phantom and patients and to compare hybrid-iterative and spectral image reconstructions of conventional images (CI-IR and CI-SR). METHODS: All imaging was performed on a SDCT (Philips Healthcare, Best, The Netherlands). Images of a non-anthropomorphic phantom with a lesion-mimicking insert (containing iodine in water solution) and arterial-phase images from contrast-enhanced patient examinations were evaluated. VMIs (40-200 keV, 10 keV increment), CI-IR, and CI-SR were reconstructed using different strengths of image denoising. ROIs were placed in lesions, liver/matrix, muscle; signal-to-noise, contrast-to-noise, and lesion-to-liver ratios (SNR, CNR, and LLR) were calculated. Qualitatively, 40, 70, and 110 keV and CI images were assessed by two radiologists on five-point Likert scales regarding overall image quality, lesion assessment, and noise. RESULTS: In phantoms, SNR was increased threefold by VMI40keV compared with CI-IR/SR (5.8 ± 1.1 vs. 18.8 ± 2.2, p ≤ 0.001), while no difference was found between CI-IR and CI-SR (p = 1). Denoising was capable of noise reduction by 40%. In total, 20 patients exhibiting 51 liver lesions were assessed. Attenuation was the highest in VMI40keV, while image noise was comparable to CI-IR resulting in a threefold increase of CNR/LLR (CI-IR 1.3 ± 0.8/4.4 ± 2.0, VMI40keV: 3.8 ± 2.7/14.2 ± 7.5, p ≤ 0.001). Subjective lesion delineation was the best in VMI40keV image (p ≤ 0.01), which also provided the lowest perceptible noise and the best overall image quality. CONCLUSIONS: VMIs improve assessment of arterially hyper-enhancing liver lesions since they increase lesion contrast while maintaining low image noise throughout the entire keV spectrum. These data suggest that to consider VMI screening after arterially hyper-enhancing liver lesions.


Asunto(s)
Neoplasias Hepáticas/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Factibilidad , Femenino , Humanos , Hígado/irrigación sanguínea , Hígado/diagnóstico por imagen , Neoplasias Hepáticas/irrigación sanguínea , Masculino , Persona de Mediana Edad , Fantasmas de Imagen
6.
Br J Radiol ; 88(1046): 20140683, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25465353

RESUMEN

OBJECTIVE: To compare six different scenarios for correcting for breathing motion in abdominal dual-energy CT (DECT) perfusion measurements. METHODS: Rigid [RRComm(80 kVp)] and non-rigid [NRComm(80 kVp)] registration of commercially available CT perfusion software, custom non-rigid registration [NRCustom(80 kVp], demons algorithm) and a control group [CG(80 kVp)] without motion correction were evaluated using 80 kVp images. Additionally, NRCustom was applied to dual-energy (DE)-blended [NRCustom(DE)] and virtual non-contrast [NRCustom(VNC)] images, yielding six evaluated scenarios. After motion correction, perfusion maps were calculated using a combined maximum slope/Patlak model. For qualitative evaluation, three blinded radiologists independently rated motion correction quality and resulting perfusion maps on a four-point scale (4 = best, 1 = worst). For quantitative evaluation, relative changes in metric values, R(2) and residuals of perfusion model fits were calculated. RESULTS: For motion-corrected images, mean ratings differed significantly [NRCustom(80 kVp) and NRCustom(DE), 3.3; NRComm(80 kVp), 3.1; NRCustom(VNC), 2.9; RRComm(80 kVp), 2.7; CG(80 kVp), 2.7; all p < 0.05], except when comparing NRCustom(80 kVp) with NRCustom(DE) and RRComm(80 kVp) with CG(80 kVp). NRCustom(80 kVp) and NRCustom(DE) achieved the highest reduction in metric values [NRCustom(80 kVp), 48.5%; NRCustom(DE), 45.6%; NRComm(80 kVp), 29.2%; NRCustom(VNC), 22.8%; RRComm(80 kVp), 0.6%; CG(80 kVp), 0%]. Regarding perfusion maps, NRCustom(80 kVp) and NRCustom(DE) were rated highest [NRCustom(80 kVp), 3.1; NRCustom(DE), 3.0; NRComm(80 kVp), 2.8; NRCustom(VNC), 2.6; CG(80 kVp), 2.5; RRComm(80 kVp), 2.4] and had significantly higher R(2) and lower residuals. Correlation between qualitative and quantitative evaluation was low to moderate. CONCLUSION: Non-rigid motion correction improves spatial alignment of the target region and fit of CT perfusion models. Using DE-blended and DE-VNC images for deformable registration offers no significant improvement. ADVANCES IN KNOWLEDGE: Non-rigid algorithms improve the quality of abdominal CT perfusion measurements but do not benefit from DECT post processing.


Asunto(s)
Algoritmos , Neoplasias Pancreáticas/diagnóstico por imagen , Imagen de Perfusión/métodos , Radiografía Abdominal , Tomografía Computarizada por Rayos X/métodos , Abdomen , Humanos , Movimiento (Física) , Recurrencia Local de Neoplasia/diagnóstico por imagen , Reproducibilidad de los Resultados , Respiración
7.
Eur J Radiol ; 82(2): 208-14, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23062281

RESUMEN

PURPOSE: To evaluate the feasibility of dual-energy CT (DECT)-perfusion of pancreatic carcinomas for assessing the differences in perfusion, permeability and blood volume of healthy pancreatic tissue and histopathologically confirmed solid pancreatic carcinoma. MATERIALS AND METHODS: 24 patients with histologically proven pancreatic carcinoma were examined prospectively with a 64-slice dual source CT using a dynamic sequence of 34 dual-energy (DE) acquisitions every 1.5s (80 ml of iodinated contrast material, 370 mg/ml, flow rate 5 ml/s). 80 kV(p), 140 kV(p), and weighted average (linearly blended M0.3) 120 kV(p)-equivalent dual-energy perfusion image data sets were evaluated with a body-perfusion CT tool (Body-PCT, Siemens Medical Solutions, Erlangen, Germany) for estimating perfusion, permeability, and blood volume values. Color-coded parameter maps were generated. RESULTS: In all 24 patients dual-energy CT-perfusion was. All carcinomas could be identified in the color-coded perfusion maps. Calculated perfusion, permeability and blood volume values were significantly lower in pancreatic carcinomas compared to healthy pancreatic tissue. Weighted average 120 kV(p)-equivalent perfusion-, permeability- and blood volume-values determined from DE image data were 0.27 ± 0.04 min(-1) vs. 0.91 ± 0.04 min(-1) (p<0.0001), 0.5 ± 0.07 *0.5 min(-1) vs. 0.67 ± 0.05 *0.5 min(-1) (p=0.06) and 0.49 ± 0.07 min(-1) vs. 1.28 ± 0.11 min(-1) (p<0.0001). Compared with 80 and 140 kV(p) the standard deviations of the kV(p)120 kV(p)-equivalent values were manifestly smaller. CONCLUSION: Dual-energy CT-perfusion of the pancreas is feasible. The use of DECT improves the accuracy of CT-perfusion of the pancreas by fully exploiting the advantages of enhanced iodine contrast at 80 kV(p) in combination with the noise reduction at 140 kV(p). Therefore using dual-energy perfusion data could improve the delineation of pancreatic carcinomas.


Asunto(s)
Adenocarcinoma/diagnóstico por imagen , Neoplasias Pancreáticas/diagnóstico por imagen , Imagen de Perfusión/métodos , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad