Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 118
Filtrar
1.
Cell ; 183(2): 395-410.e19, 2020 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-33007268

RESUMEN

Collective metastasis is defined as the cohesive migration and metastasis of multicellular tumor cell clusters. Disrupting various cell adhesion genes markedly reduces cluster formation and colonization efficiency, yet the downstream signals transmitted by clustering remain largely unknown. Here, we use mouse and human breast cancer models to identify a collective signal generated by tumor cell clusters supporting metastatic colonization. We show that tumor cell clusters produce the growth factor epigen and concentrate it within nanolumina-intercellular compartments sealed by cell-cell junctions and lined with microvilli-like protrusions. Epigen knockdown profoundly reduces metastatic outgrowth and switches clusters from a proliferative to a collective migratory state. Tumor cell clusters from basal-like 2, but not mesenchymal-like, triple-negative breast cancer cell lines have increased epigen expression, sealed nanolumina, and impaired outgrowth upon nanolumenal junction disruption. We propose that nanolumenal signaling could offer a therapeutic target for aggressive metastatic breast cancers.


Asunto(s)
Neoplasias de la Mama/fisiopatología , Uniones Intercelulares/patología , Metástasis de la Neoplasia/fisiopatología , Animales , Adhesión Celular/fisiología , Línea Celular Tumoral , Movimiento Celular/fisiología , Epigen/metabolismo , Transición Epitelial-Mesenquimal/genética , Humanos , Ratones , Células Neoplásicas Circulantes/patología , Transducción de Señal/fisiología , Neoplasias de la Mama Triple Negativas/patología
2.
Radiology ; 310(2): e232313, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38349238

RESUMEN

Background The Eastern Cooperative Oncology Group-American College of Radiology Imaging Network Cancer Research Group multicenter A6702 trial identified an optimal apparent diffusion coefficient (ADC) cutoff to potentially reduce biopsies by 21% without affecting sensitivity. Whether this performance can be achieved in clinical settings has not yet been established. Purpose To validate the performance of point-of-care ADC measurements with the A6702 trial ADC cutoff for reducing unnecessary biopsies in lesions detected at breast MRI. Materials and Methods Consecutive breast MRI examinations performed from May 2015 to January 2019 at a single medical center and showing biopsy-confirmed Breast Imaging Reporting and Data System category 4 or 5 lesions, without ipsilateral cancer, were identified. Point-of-care lesion ADC measurements collected at clinical interpretation were retrospectively evaluated. MRI examinations included axial T2-weighted, diffusion-weighted, and dynamic contrast-enhanced sequences. Sensitivity and biopsy reduction rates were calculated by applying the A6702 optimal (ADC, 1.53 × 10-3 mm2/sec) and alternate conservative (1.68 × 10-3 mm2/sec) cutoffs. Lesion pathologic outcomes were the reference standard. To assess reproducibility, one radiologist repeated ADC measurements, and agreement was summarized using the intraclass correlation coefficient. Results A total of 240 lesions in 201 women (mean age, 49 years ± 13 [SD]) with pathologic outcomes (63 malignant and 177 benign) were included. Applying the optimal ADC cutoff produced an overall biopsy reduction rate of 15.8% (38 of 240 lesions [95% CI: 11.2, 20.9]), with a sensitivity of 92.1% (58 of 63 lesions [95% CI: 82.4, 97.4]; sensitivity was 97.2% [35 of 36 lesions] [95% CI: 82.7, 99.6] for invasive cancers). Results were similar for screening versus diagnostic examinations (P = .92 and .40, respectively). Sensitivity was higher for masses than for nonmass enhancements (NMEs) (100% vs 85.3%; P = .009). Applying the conservative ADC cutoff achieved a sensitivity of 95.2% (60 of 63 lesions [95% CI: 86.7, 99.0]), with a biopsy reduction rate of 10.4% (25 of 240 lesions [95% CI: 6.7, 14.5]). Repeated single-reader measurements showed good agreement with clinical ADCs (intraclass correlation coefficient, 0.72 [95% CI: 0.58, 0.81]). Conclusion This study validated the clinical use of ADC cutoffs to reduce MRI-prompted biopsies by up to 16%, with a suggested tradeoff of lowered sensitivity for in situ and microinvasive disease manifesting as NME. Clinical trial registration no. NCT02022579 © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Honda and Iima in this issue.


Asunto(s)
Imagen por Resonancia Magnética , Sistemas de Atención de Punto , Femenino , Humanos , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Biopsia
3.
Magn Reson Med ; 91(5): 1803-1821, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38115695

RESUMEN

PURPOSE: K trans $$ {K}^{\mathrm{trans}} $$ has often been proposed as a quantitative imaging biomarker for diagnosis, prognosis, and treatment response assessment for various tumors. None of the many software tools for K trans $$ {K}^{\mathrm{trans}} $$ quantification are standardized. The ISMRM Open Science Initiative for Perfusion Imaging-Dynamic Contrast-Enhanced (OSIPI-DCE) challenge was designed to benchmark methods to better help the efforts to standardize K trans $$ {K}^{\mathrm{trans}} $$ measurement. METHODS: A framework was created to evaluate K trans $$ {K}^{\mathrm{trans}} $$ values produced by DCE-MRI analysis pipelines to enable benchmarking. The perfusion MRI community was invited to apply their pipelines for K trans $$ {K}^{\mathrm{trans}} $$ quantification in glioblastoma from clinical and synthetic patients. Submissions were required to include the entrants' K trans $$ {K}^{\mathrm{trans}} $$ values, the applied software, and a standard operating procedure. These were evaluated using the proposed OSIP I gold $$ \mathrm{OSIP}{\mathrm{I}}_{\mathrm{gold}} $$ score defined with accuracy, repeatability, and reproducibility components. RESULTS: Across the 10 received submissions, the OSIP I gold $$ \mathrm{OSIP}{\mathrm{I}}_{\mathrm{gold}} $$ score ranged from 28% to 78% with a 59% median. The accuracy, repeatability, and reproducibility scores ranged from 0.54 to 0.92, 0.64 to 0.86, and 0.65 to 1.00, respectively (0-1 = lowest-highest). Manual arterial input function selection markedly affected the reproducibility and showed greater variability in K trans $$ {K}^{\mathrm{trans}} $$ analysis than automated methods. Furthermore, provision of a detailed standard operating procedure was critical for higher reproducibility. CONCLUSIONS: This study reports results from the OSIPI-DCE challenge and highlights the high inter-software variability within K trans $$ {K}^{\mathrm{trans}} $$ estimation, providing a framework for ongoing benchmarking against the scores presented. Through this challenge, the participating teams were ranked based on the performance of their software tools in the particular setting of this challenge. In a real-world clinical setting, many of these tools may perform differently with different benchmarking methodology.


Asunto(s)
Medios de Contraste , Imagen por Resonancia Magnética , Humanos , Reproducibilidad de los Resultados , Imagen por Resonancia Magnética/métodos , Programas Informáticos , Algoritmos
4.
AJR Am J Roentgenol ; 222(1): e2329933, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37850579

RESUMEN

DWI is a noncontrast MRI technique that measures the diffusion of water molecules within biologic tissue. DWI is increasingly incorporated into routine breast MRI examinations. Currently, the main applications of DWI are breast cancer detection and characterization, prognostication, and prediction of treatment response to neoadjuvant chemotherapy. In addition, DWI is promising as a noncontrast MRI alternative for breast cancer screening. Problems with suboptimal resolution and image quality have restricted the mainstream use of DWI for breast imaging, but these shortcomings are being addressed through several technologic advancements. In this review, we present an up-to-date assessment of the use of DWI for breast cancer imaging, including a summary of the clinical literature and recommendations for future use.


Asunto(s)
Neoplasias de la Mama , Humanos , Femenino , Imagen de Difusión por Resonancia Magnética/métodos , Aumento de la Imagen/métodos , Sensibilidad y Especificidad , Mama
5.
Breast Cancer Res ; 25(1): 138, 2023 11 09.
Artículo en Inglés | MEDLINE | ID: mdl-37946201

RESUMEN

PURPOSE: To investigate combined MRI and 18F-FDG PET for assessing breast tumor metabolism/perfusion mismatch and predicting pathological response and recurrence-free survival (RFS) in women treated for breast cancer. METHODS: Patients undergoing neoadjuvant chemotherapy (NAC) for locally-advanced breast cancer were imaged at three timepoints (pre, mid, and post-NAC), prior to surgery. Imaging included diffusion-weighted and dynamic contrast-enhanced (DCE-) MRI and quantitative 18F-FDG PET. Tumor imaging measures included apparent diffusion coefficient, peak percent enhancement (PE), peak signal enhancement ratio (SER), functional tumor volume, and washout volume on MRI and standardized uptake value (SUVmax), glucose delivery (K1) and FDG metabolic rate (MRFDG) on PET, with percentage changes from baseline calculated at mid- and post-NAC. Associations of imaging measures with pathological response (residual cancer burden [RCB] 0/I vs. II/III) and RFS were evaluated. RESULTS: Thirty-five patients with stage II/III invasive breast cancer were enrolled in the prospective study (median age: 43, range: 31-66 years, RCB 0/I: N = 11/35, 31%). Baseline imaging metrics were not significantly associated with pathologic response or RFS (p > 0.05). Greater mid-treatment decreases in peak PE, along with greater post-treatment decreases in several DCE-MRI and 18F-FDG PET measures were associated with RCB 0/I after NAC (p < 0.05). Additionally, greater mid- and post-treatment decreases in DCE-MRI (peak SER, washout volume) and 18F-FDG PET (K1) were predictive of prolonged RFS. Mid-treatment decreases in metabolism/perfusion ratios (MRFDG/peak PE, MRFDG/peak SER) were associated with improved RFS. CONCLUSION: Mid-treatment changes in both PET and MRI measures were predictive of RCB status and RFS following NAC. Specifically, our results indicate a complementary relationship between DCE-MRI and 18F-FDG PET metrics and potential value of metabolism/perfusion mismatch as a marker of patient outcome.


Asunto(s)
Neoplasias de la Mama , Humanos , Femenino , Adulto , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/tratamiento farmacológico , Fluorodesoxiglucosa F18/uso terapéutico , Terapia Neoadyuvante/métodos , Radiofármacos/uso terapéutico , Estudios Prospectivos , Resultado del Tratamiento , Imagen por Resonancia Magnética/métodos , Tomografía de Emisión de Positrones/métodos
6.
Radiology ; 308(2): e230576, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37581498

RESUMEN

Background Contrast-enhanced mammography (CEM) and abbreviated breast MRI (ABMRI) are emerging alternatives to standard MRI for supplemental breast cancer screening. Purpose To compare the diagnostic performance of CEM, ABMRI, and standard MRI. Materials and Methods This single-institution, prospective, blinded reader study included female participants referred for breast MRI from January 2018 to June 2021. CEM was performed within 14 days of standard MRI; ABMRI was produced from standard MRI images. Two readers independently interpreted each CEM and ABMRI after a washout period. Examination-level performance metrics calculated were recall rate, cancer detection, and false-positive biopsy recommendation rates per 1000 examinations and sensitivity, specificity, and positive predictive value of biopsy recommendation. Bootstrap and permutation tests were used to calculate 95% CIs and compare modalities. Results Evaluated were 492 paired CEM and ABMRI interpretations from 246 participants (median age, 51 years; IQR, 43-61 years). On 49 MRI scans with lesions recommended for biopsy, nine lesions showed malignant pathology. No differences in ABMRI and standard MRI performance were identified. Compared with standard MRI, CEM demonstrated significantly lower recall rate (14.0% vs 22.8%; difference, -8.7%; 95% CI: -14.0, -3.5), lower false-positive biopsy recommendation rate per 1000 examinations (65.0 vs 162.6; difference, -97.6; 95% CI: -146.3, -50.8), and higher specificity (87.8% vs 80.2%; difference, 7.6%; 95% CI: 2.3, 13.1). Compared with standard MRI, CEM had significantly lower cancer detection rate (22.4 vs 36.6; difference, -14.2; 95% CI: -28.5, -2.0) and sensitivity (61.1% vs 100%; difference, -38.9%; 95% CI: -66.7, -12.5). The performance differences between CEM and ABMRI were similar to those observed between CEM and standard MRI. Conclusion ABMRI had comparable performance to standard MRI and may support more efficient MRI screening. CEM had lower recall and higher specificity compared with standard MRI or ABMRI, offset by lower cancer detection rate and sensitivity compared with standard MRI. These trade-offs warrant further consideration of patient population characteristics before widespread screening with CEM. Clinical trial registration no. NCT03517813 © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Chang in this issue.


Asunto(s)
Neoplasias de la Mama , Femenino , Humanos , Persona de Mediana Edad , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Estudios Prospectivos , Sensibilidad y Especificidad , Detección Precoz del Cáncer/métodos , Mamografía/métodos , Imagen por Resonancia Magnética/métodos
7.
J Therm Biol ; 111: 103437, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36585071

RESUMEN

OBJECTIVES: To determine the impact of physical activity on temperature after within-limb calibration (TAWiC) measures and their reproducibility. To determine if thermal imaging from a smartphone attached thermal camera is comparable to thermal imaging using a handheld thermal camera for detection of arthritis in children. METHODS: Children without symptoms were enrolled to the "asymptomatic exercise cohort", and received infrared imaging, using a standard handheld camera, after initial resting period, after activity, and after second resting period. Children seen in the rheumatology clinic with knee pain were enrolled into the "symptomatic knee pain cohort" and received imaging with both the smartphone-attached and handheld cameras before a routine clinical exam. TAWiC was defined as the temperature differences between joint and ipsilateral mid-tibia as the main readout for arthritis detection. RESULTS: The asymptomatic exercise cohort demonstrated notable changes in absolute and TAWiC temperatures collected by thermal imaging after physical activity, and temperatures did not consistently return to pre-activity levels after a second period of rest. The 95th TAWiC from anterior view were, resting one -0.1 C (0.5), activity -0.7 C (0.5), resting two -0.2 C (0.6) (resting 1 vs resting 2, p-value = 0.13). In the symptomatic knee pain cohort, the smartphone attached and handheld thermal cameras performed similarly in regards to detection of joint inflammation and evaluation of joint temperature using the TAWiC algorithm, with high sensitivity of 80% (55.2-100.0%) and specificity of 84.2% (76.0-92.4%) in the anterior knee view when compared with the gold standard joint exam performed by a pediatric rheumatologist. The mean 95th TAWiC temperature difference between the two cameras was -0.1 C (-0.1 to 0.0) (p = 0.0004). CONCLUSIONS: This study showed continued validity of the TAWiC algorithm across two distinct thermal camera platforms and demonstrates promise for improved accessibility and utility of this technology for arthritis detection.


Asunto(s)
Artritis , Teléfono Inteligente , Humanos , Niño , Reproducibilidad de los Resultados , Temperatura Corporal , Dolor
8.
Eur Radiol ; 32(10): 6588-6597, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35507050

RESUMEN

OBJECTIVES: To perform a survey among all European Society of Breast Imaging (EUSOBI) radiologist members to gather representative data regarding the clinical use of breast DWI. METHODS: An online questionnaire was developed by two board-certified radiologists, reviewed by the EUSOBI board and committees, and finally distributed among EUSOBI active and associated (not based in Europe) radiologist members. The questionnaire included 20 questions pertaining to technical preferences (acquisition time, magnet strength, breast coils, number of b values), clinical indications, imaging evaluation, and reporting. Data were analyzed using descriptive statistics, the Chi-square test of independence, and Fisher's exact test. RESULTS: Of 1411 EUSOBI radiologist members, 275/1411 (19.5%) responded. Most (222/275, 81%) reported using DWI as part of their routine protocol. Common indications for DWI include lesion characterization (using an ADC threshold of 1.2-1.3 × 10-3 mm2/s) and prediction of response to chemotherapy. Members most commonly acquire two separate b values (114/217, 53%), with b value = 800 s/mm2 being the preferred value for appraisal among those acquiring more than two b values (71/171, 42%). Most did not use synthetic b values (169/217, 78%). While most mention hindered diffusion in the MRI report (161/213, 76%), only 142/217 (57%) report ADC values. CONCLUSION: The utilization of DWI in clinical practice among EUSOBI radiologists who responded to the survey is generally in line with international recommendations, with the main application being the differentiation of benign and malignant enhancing lesions, treatment response assessment, and prediction of response to chemotherapy. Report integration of qualitative and quantitative DWI data is not uniform. KEY POINTS: • Clinical performance of breast DWI is in good agreement with the current recommendations of the EUSOBI International Breast DWI working group. • Breast DWI applications in clinical practice include the differentiation of benign and malignant enhancing, treatment response assessment, and prediction of response to chemotherapy. • Report integration of DWI results is not uniform.


Asunto(s)
Neoplasias de la Mama , Imagen de Difusión por Resonancia Magnética , Mama/diagnóstico por imagen , Mama/patología , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Imagen de Difusión por Resonancia Magnética/métodos , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Sensibilidad y Especificidad , Encuestas y Cuestionarios
9.
Radiology ; 298(1): 60-70, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33201788

RESUMEN

Background The Eastern Cooperative Oncology Group and American College of Radiology Imaging Network Cancer Research Group A6702 multicenter trial helped confirm the potential of diffusion-weighted MRI for improving differential diagnosis of suspicious breast abnormalities and reducing unnecessary biopsies. A prespecified secondary objective was to explore the relative value of different approaches for quantitative assessment of lesions at diffusion-weighted MRI. Purpose To determine whether alternate calculations of apparent diffusion coefficient (ADC) can help further improve diagnostic performance versus mean ADC values alone for analysis of suspicious breast lesions at MRI. Materials and Methods This prospective trial (ClinicalTrials.gov identifier: NCT02022579) enrolled consecutive women (from March 2014 to April 2015) with a Breast Imaging Reporting and Data System category of 3, 4, or 5 at breast MRI. All study participants underwent standardized diffusion-weighted MRI (b = 0, 100, 600, and 800 sec/mm2). Centralized ADC measures were performed, including manually drawn whole-lesion and hotspot regions of interest, histogram metrics, normalized ADC, and variable b-value combinations. Diagnostic performance was estimated by using the area under the receiver operating characteristic curve (AUC). Reduction in biopsy rate (maintaining 100% sensitivity) was estimated according to thresholds for each ADC metric. Results Among 107 enrolled women, 81 lesions with outcomes (28 malignant and 53 benign) in 67 women (median age, 49 years; interquartile range, 41-60 years) were analyzed. Among ADC metrics tested, none improved diagnostic performance versus standard mean ADC (AUC, 0.59-0.79 vs AUC, 0.75; P = .02-.84), and maximum ADC had worse performance (AUC, 0.52; P < .001). The 25th-percentile ADC metric provided the best performance (AUC, 0.79; 95% CI: 0.70, 0.88), and a threshold using median ADC provided the greatest reduction in biopsy rate of 23.9% (95% CI: 14.8, 32.9; 16 of 67 BI-RADS category 4 and 5 lesions). Nonzero minimum b value (100, 600, and 800 sec/mm2) did not improve the AUC (0.74; P = .28), and several combinations of two b values (0 and 600, 100 and 600, 0 and 800, and 100 and 800 sec/mm2; AUC, 0.73-0.76) provided results similar to those seen with calculations of four b values (AUC, 0.75; P = .17-.87). Conclusion Mean apparent diffusion coefficient calculated with a two-b-value acquisition is a simple and sufficient diffusion-weighted MRI metric to augment diagnostic performance of breast MRI compared with more complex approaches to apparent diffusion coefficient measurement. © RSNA, 2020 Online supplemental material is available for this article.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética/métodos , Adulto , Anciano , Mama/diagnóstico por imagen , Diagnóstico Diferencial , Femenino , Humanos , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Sociedades Médicas , Adulto Joven
10.
Radiology ; 301(2): 295-308, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34427465

RESUMEN

Background Suppression of background parenchymal enhancement (BPE) is commonly observed after neoadjuvant chemotherapy (NAC) at contrast-enhanced breast MRI. It was hypothesized that nonsuppressed BPE may be associated with inferior response to NAC. Purpose To investigate the relationship between lack of BPE suppression and pathologic response. Materials and Methods A retrospective review was performed for women with menopausal status data who were treated for breast cancer by one of 10 drug arms (standard NAC with or without experimental agents) between May 2010 and November 2016 in the Investigation of Serial Studies to Predict Your Therapeutic Response with Imaging and Molecular Analysis 2, or I-SPY 2 TRIAL (NCT01042379). Patients underwent MRI at four points: before treatment (T0), early treatment (T1), interregimen (T2), and before surgery (T3). BPE was quantitatively measured by using automated fibroglandular tissue segmentation. To test the hypothesis effectively, a subset of examinations with BPE with high-quality segmentation was selected. BPE change from T0 was defined as suppressed or nonsuppressed for each point. The Fisher exact test and the Z tests of proportions with Yates continuity correction were used to examine the relationship between BPE suppression and pathologic complete response (pCR) in hormone receptor (HR)-positive and HR-negative cohorts. Results A total of 3528 MRI scans from 882 patients (mean age, 48 years ± 10 [standard deviation]) were reviewed and the subset of patients with high-quality BPE segmentation was determined (T1, 433 patients; T2, 396 patients; T3, 380 patients). In the HR-positive cohort, an association between lack of BPE suppression and lower pCR rate was detected at T2 (nonsuppressed vs suppressed, 11.8% [six of 51] vs 28.9% [50 of 173]; difference, 17.1% [95% CI: 4.7, 29.5]; P = .02) and T3 (nonsuppressed vs suppressed, 5.3% [two of 38] vs 27.4% [48 of 175]; difference, 22.2% [95% CI: 10.9, 33.5]; P = .003). In the HR-negative cohort, patients with nonsuppressed BPE had lower estimated pCR rate at all points, but the P values for the association were all greater than .05. Conclusions In hormone receptor-positive breast cancer, lack of background parenchymal enhancement suppression may indicate inferior treatment response. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Philpotts in this issue.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/tratamiento farmacológico , Quimioterapia Adyuvante/métodos , Medios de Contraste , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Terapia Neoadyuvante/métodos , Adulto , Anciano , Mama/diagnóstico por imagen , Estudios de Cohortes , Femenino , Humanos , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
11.
J Magn Reson Imaging ; 51(1): 43-61, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31004391

RESUMEN

The degree of normal fibroglandular tissue that enhances on breast MRI, known as background parenchymal enhancement (BPE), was initially described as an incidental finding that could affect interpretation performance. While BPE is now established to be a physiologic phenomenon that is affected by both endogenous and exogenous hormone levels, evidence supporting the notion that BPE frequently masks breast cancers is limited. However, compelling data have emerged to suggest BPE is an independent marker of breast cancer risk and breast cancer treatment outcomes. Specifically, multiple studies have shown that elevated BPE levels, measured qualitatively or quantitatively, are associated with a greater risk of developing breast cancer. Evidence also suggests that BPE could be a predictor of neoadjuvant breast cancer treatment response and overall breast cancer treatment outcomes. These discoveries come at a time when breast cancer screening and treatment have moved toward an increased emphasis on targeted and individualized approaches, of which the identification of imaging features that can predict cancer diagnosis and treatment response is an increasingly recognized component. Historically, researchers have primarily studied quantitative tumor imaging features in pursuit of clinically useful biomarkers. However, the need to segment less well-defined areas of normal tissue for quantitative BPE measurements presents its own unique challenges. Furthermore, there is no consensus on the optimal timing on dynamic contrast-enhanced MRI for BPE quantitation. This article comprehensively reviews BPE with a particular focus on its potential to increase precision approaches to breast cancer risk assessment, diagnosis, and treatment. It also describes areas of needed future research, such as the applicability of BPE to women at average risk, the biological underpinnings of BPE, and the standardization of BPE characterization. Level of Evidence: 3 Technical Efficacy Stage: 5 J. Magn. Reson. Imaging 2020;51:43-61.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Mama/diagnóstico por imagen , Femenino , Humanos
12.
Eur Radiol ; 30(5): 2561-2570, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-31965256

RESUMEN

Diffusion MRI (often called diffusion-weighted imaging or DWI) has enjoyed a tremendous growth since its introduction in the mid-1980s, especially to investigate neurological disorders and in oncology. At a time when standardization and quality control appear as critical as ever to support widespread utilization, our aim was to address common fundamental questions that arise regarding results obtained with DWI. We focus on six questions taking breast DWI as an example, as breast DWI is increasingly used in clinical practice, but most of our conclusions would apply to DWI in general. We show especially that noise can act in a pernicious way specific to DWI. Ignoring such noise effects could lead to incorrect data interpretations or conclusions, of which authors and readers may be genuinely unaware. While addressing these six questions, we give practical examples of how noise effects can be understood, corrected when possible, or taken to our advantage. Key Points • Ignoring noise effects in DWI could lead to incorrect data interpretations or conclusions, of which authors and readers may be genuinely unaware. • In vivo apparent diffusion coefficient (ADC) decreases with b value, which must therefore be reported along with ADC. • Synthesized DWI boosts contrast at the expense of accurate diffusion/microstructure characterization.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Mama/patología , Imagen de Difusión por Resonancia Magnética/métodos , Medios de Contraste/farmacología , Femenino , Humanos
13.
Eur Radiol ; 30(3): 1436-1450, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31786616

RESUMEN

The European Society of Breast Radiology (EUSOBI) established an International Breast DWI working group. The working group consists of clinical breast MRI experts, MRI physicists, and representatives from large vendors of MRI equipment, invited based upon proven expertise in breast MRI and/or in particular breast DWI, representing 25 sites from 16 countries. The aims of the working group are (a) to promote the use of breast DWI into clinical practice by issuing consensus statements and initiate collaborative research where appropriate; (b) to define necessary standards and provide practical guidance for clinical application of breast DWI; (c) to develop a standardized and translatable multisite multivendor quality assurance protocol, especially for multisite research studies; (d) to find consensus on optimal methods for image processing/analysis, visualization, and interpretation; and (e) to work collaboratively with system vendors to improve breast DWI sequences. First consensus recommendations, presented in this paper, include acquisition parameters for standard breast DWI sequences including specifications of b values, fat saturation, spatial resolution, and repetition and echo times. To describe lesions in an objective way, levels of diffusion restriction/hindrance in the breast have been defined based on the published literature on breast DWI. The use of a small ROI placed on the darkest part of the lesion on the ADC map, avoiding necrotic, noisy or non-enhancing lesion voxels is currently recommended. The working group emphasizes the need for standardization and quality assurance before ADC thresholds are applied. The working group encourages further research in advanced diffusion techniques and tailored DWI strategies for specific indications. Key Points • The working group considers breast DWI an essential part of a multiparametric breast MRI protocol and encourages its use. • Basic requirements for routine clinical application of breast DWI are provided, including recommendations on b values, fat saturation, spatial resolution, and other sequence parameters. • Diffusion levels in breast lesions are defined based on meta-analysis data and methods to obtain a reliable ADC value are detailed.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Mama/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética/métodos , Mama/patología , Neoplasias de la Mama/patología , Consenso , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Sensibilidad y Especificidad
14.
Breast Cancer Res ; 21(1): 102, 2019 09 04.
Artículo en Inglés | MEDLINE | ID: mdl-31484577

RESUMEN

BACKGROUND: Diffusion-weighted imaging (DWI) can increase breast MRI diagnostic specificity due to the tendency of malignancies to restrict diffusion. Diffusion tensor imaging (DTI) provides further information over conventional DWI regarding diffusion directionality and anisotropy. Our study evaluates DTI features of suspicious breast lesions detected on MRI to determine the added diagnostic value of DTI for breast imaging. METHODS: With IRB approval, we prospectively enrolled patients over a 3-year period who had suspicious (BI-RADS category 4 or 5) MRI-detected breast lesions with histopathological results. Patients underwent multiparametric 3 T MRI with dynamic contrast-enhanced (DCE) and DTI sequences. Clinical factors (age, menopausal status, breast density, clinical indication, background parenchymal enhancement) and DCE-MRI lesion parameters (size, type, presence of washout, BI-RADS category) were recorded prospectively by interpreting radiologists. DTI parameters (apparent diffusion coefficient [ADC], fractional anisotropy [FA], axial diffusivity [λ1], radial diffusivity [(λ2 + λ3)/2], and empirical difference [λ1 - λ3]) were measured retrospectively. Generalized estimating equations (GEE) and least absolute shrinkage and selection operator (LASSO) methods were used for univariate and multivariate logistic regression, respectively. Diagnostic performance was internally validated using the area under the curve (AUC) with bootstrap adjustment. RESULTS: The study included 238 suspicious breast lesions (95 malignant, 143 benign) in 194 women. In univariate analysis, lower ADC, axial diffusivity, and radial diffusivity were associated with malignancy (OR = 0.37-0.42 per 1-SD increase, p < 0.001 for each), as was higher FA (OR = 1.45, p = 0.007). In multivariate analysis, LASSO selected only ADC (OR = 0.41) as a predictor for a DTI-only model, while both ADC (OR = 0.41) and FA (OR = 0.88) were selected for a model combining clinical and imaging parameters. Post-hoc analysis revealed varying association of FA with malignancy depending on the lesion type. The combined model (AUC = 0.81) had a significantly better performance than Clinical/DCE-MRI-only (AUC = 0.76, p < 0.001) and DTI-only (AUC = 0.75, p = 0.002) models. CONCLUSIONS: DTI significantly improves diagnostic performance in multivariate modeling. ADC is the most important diffusion parameter for distinguishing benign and malignant breast lesions, while anisotropy measures may help further characterize tumor microstructure and microenvironment.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Mama/diagnóstico por imagen , Imagen de Difusión Tensora , Aumento de la Imagen/métodos , Adulto , Anciano , Anciano de 80 o más Años , Mama/patología , Medios de Contraste , Diagnóstico Diferencial , Imagen de Difusión por Resonancia Magnética , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Persona de Mediana Edad , Estudios Prospectivos , Curva ROC , Microambiente Tumoral , Adulto Joven
15.
Radiology ; 293(3): 504-520, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31592734

RESUMEN

Diffusion-weighted (DW) MRI is a rapid technique that measures the mobility of water molecules within tissue, reflecting the cellular microenvironment. At DW MRI, breast cancers typically exhibit reduced diffusivity and appear hyperintense to surrounding tissues. On the basis of this characteristic, DW MRI may offer an unenhanced method to detect breast cancer without the costs and safety concerns associated with dynamic contrast material-enhanced MRI, the current reference standard in the setting of high-risk screening. This application of DW MRI has not been widely explored but is particularly timely given the growing health concerns related to the long-term use of gadolinium-based contrast material. Moreover, increasing breast density notification legislation across the United States is raising awareness of the limitations of mammography in women with dense breasts, emphasizing the need for additional cost-effective supplemental screening examinations. Preliminary studies suggest unenhanced MRI with DW MRI may provide higher sensitivity than screening mammography for the detection of breast malignancies. Larger prospective multicenter trials are needed to validate single-center findings and assess the performance of DW MRI for generalized breast cancer screening. Standardization of DW MRI acquisition and interpretation is essential to ensure reliable sensitivity and specificity, and an optimal approach for screening using readily available techniques is proposed here.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética/métodos , Detección Precoz del Cáncer , Femenino , Humanos
16.
BMC Cancer ; 19(1): 1043, 2019 Nov 05.
Artículo en Inglés | MEDLINE | ID: mdl-31690273

RESUMEN

BACKGROUND: Radiological imaging plays a central role in the diagnosis of breast cancer (BC). Some studies suggest MRI techniques like diffusion weighted imaging (DWI) may provide further prognostic value by discriminating between tumors with different biologic characteristics including receptor status and molecular subtype. However, there is much contradictory reported data regarding such associations in the literature. The purpose of the present study was to provide evident data regarding relationships between quantitative apparent diffusion coefficient (ADC) values on DWI and pathologic prognostic factors in BC. METHODS: Data from 5 centers (661 female patients, mean age, 51.4 ± 10.5 years) were acquired. Invasive ductal carcinoma (IDC) was diagnosed in 625 patients (94.6%) and invasive lobular carcinoma in 36 cases (5.4%). Luminal A carcinomas were diagnosed in 177 patients (28.0%), luminal B carcinomas in 279 patients (44.1%), HER 2+ carcinomas in 66 cases (10.4%), and triple negative carcinomas in 111 patients (17.5%). The identified lesions were staged as T1 in 51.3%, T2 in 43.0%, T3 in 4.2%, and as T4 in 1.5% of the cases. N0 was found in 61.3%, N1 in 33.1%, N2 in 2.9%, and N3 in 2.7%. ADC values between different groups were compared using the Mann-Whitney U test and by the Kruskal-Wallis H test. The association between ADC and Ki 67 values was calculated by Spearman's rank correlation coefficient. RESULTS: ADC values of different tumor subtypes overlapped significantly. Luminal B carcinomas had statistically significant lower ADC values compared with luminal A (p = 0.003) and HER 2+ (p = 0.007) lesions. No significant differences of ADC values were observed between luminal A, HER 2+ and triple negative tumors. There were no statistically significant differences of ADC values between different T or N stages of the tumors. Weak statistically significant correlation between ADC and Ki 67 was observed in luminal B carcinoma (r = - 0.130, p = 0.03). In luminal A, HER 2+ and triple negative tumors there were no significant correlations between ADC and Ki 67. CONCLUSION: ADC was not able to discriminate molecular subtypes of BC, and cannot be used as a surrogate marker for disease stage or proliferation activity.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Carcinoma Ductal/diagnóstico , Imagen de Difusión por Resonancia Magnética/métodos , Ganglios Linfáticos/diagnóstico por imagen , Glándulas Mamarias Humanas/diagnóstico por imagen , Adulto , Neoplasias de la Mama/patología , Carcinoma Ductal/patología , Diagnóstico por Imagen , Femenino , Humanos , Ganglios Linfáticos/patología , Metástasis Linfática , Glándulas Mamarias Humanas/patología , Persona de Mediana Edad , Invasividad Neoplásica , Estadificación de Neoplasias , Fenotipo , Pronóstico
17.
J Magn Reson Imaging ; 50(6): 1742-1753, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31026118

RESUMEN

BACKGROUND: The change in apparent diffusion coefficient (ADC) measured from diffusion-weighted imaging (DWI) has been shown to be predictive of pathologic complete response (pCR) for patients with locally invasive breast cancer undergoing neoadjuvant chemotherapy. PURPOSE: To investigate the additive value of tumor ADC in a multicenter clinical trial setting. STUDY TYPE: Retrospective analysis of multicenter prospective data. POPULATION: In all, 415 patients who enrolled in the I-SPY 2 TRIAL from 2010 to 2014 were included. FIELD STRENGTH/SEQUENCE: 1.5T or 3T MRI system using a fat-suppressed single-shot echo planar imaging sequence with b-values of 0 and 800 s/mm2 for DWI, followed by a T1-weighted sequence for dynamic contrast-enhanced MRI (DCE-MRI) performed at pre-NAC (T0), after 3 weeks of NAC (T1), mid-NAC (T2), and post-NAC (T3). ASSESSMENT: Functional tumor volume and tumor ADC were measured at each MRI exam; pCR measured at surgery was assessed as the binary outcome. Breast cancer subtype was defined by hormone receptor (HR) and human epidermal growth factor receptor 2 (HER2) status. STATISTICAL TESTS: A logistic regression model was used to evaluate associations between MRI predictors with pCR. The cross-validated area under the curve (AUC) was calculated to assess the predictive performance of the model with and without ADC. RESULTS: In all, 354 patients (128 HR+/HER2-, 60 HR+/HER2+, 34 HR-/HER2+, 132 HR-/HER2-) were included in the analysis. In the full cohort, adding ADC predictors increased the AUC from 0.76 to 0.78 at mid-NAC and from 0.76 to 0.81 at post-NAC. In HR/HER2 subtypes, the AUC increased from 0.52 to 0.65 at pre-NAC for HR+/HER2-, from 0.67 to 0.73 at mid-NAC and from 0.72 to 0.76 at post-NAC for HR+/HER2+, from 0.71 to 0.81 at post-NAC for triple negatives. DATA CONCLUSION: The addition of ADC to standard functional tumor volume MRI showed improvement in the prediction of treatment response in HR+ and triple-negative breast cancer. LEVEL OF EVIDENCE: 2 Technical Efficacy Stage: 4 J. Magn. Reson. Imaging 2019;50:1742-1753.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/tratamiento farmacológico , Imagen de Difusión por Resonancia Magnética/métodos , Imagen Eco-Planar/métodos , Terapia Neoadyuvante , Adulto , Anciano , Área Bajo la Curva , Neoplasias de la Mama/patología , Neoplasias de la Mama/cirugía , Terapia Combinada , Ciclofosfamida/administración & dosificación , Esquema de Medicación , Femenino , Humanos , Persona de Mediana Edad , Invasividad Neoplásica , Estadificación de Neoplasias , Paclitaxel/administración & dosificación , Estudios Prospectivos , Trastuzumab/administración & dosificación , Resultado del Tratamiento , Carga Tumoral/efectos de los fármacos
18.
J Magn Reson Imaging ; 49(6): 1617-1628, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30350329

RESUMEN

BACKGROUND: Quantitative diffusion-weighted imaging (DWI) MRI is a promising technique for cancer characterization and treatment monitoring. Knowledge of the reproducibility of DWI metrics in breast tumors is necessary to apply DWI as a clinical biomarker. PURPOSE: To evaluate the repeatability and reproducibility of breast tumor apparent diffusion coefficient (ADC) in a multi-institution clinical trial setting, using standardized DWI protocols and quality assurance (QA) procedures. STUDY TYPE: Prospective. SUBJECTS: In all, 89 women from nine institutions undergoing neoadjuvant chemotherapy for invasive breast cancer. FIELD STRENGTH/SEQUENCE: DWI was acquired before and after patient repositioning using a four b-value, single-shot echo-planar sequence at 1.5T or 3.0T. ASSESSMENT: A QA procedure by trained operators assessed artifacts, fat suppression, and signal-to-noise ratio, and determine study analyzability. Mean tumor ADC was measured via manual segmentation of the multislice tumor region referencing DWI and contrast-enhanced images. Twenty cases were evaluated multiple times to assess intra- and interoperator variability. Segmentation similarity was assessed via the Sørenson-Dice similarity coefficient. STATISTICAL TESTS: Repeatability and reproducibility were evaluated using within-subject coefficient of variation (wCV), intraclass correlation coefficient (ICC), agreement index (AI), and repeatability coefficient (RC). Correlations were measured by Pearson's correlation coefficients. RESULTS: In all, 71 cases (80%) passed QA evaluation: 44 at 1.5T, 27 at 3.0T; 60 pretreatment, 11 after 3 weeks of taxane-based treatment. ADC repeatability was excellent: wCV = 4.8% (95% confidence interval [CI] 4.0, 5.7%), ICC = 0.97 (95% CI 0.95, 0.98), AI = 0.83 (95% CI 0.76, 0.87), and RC = 0.16 * 10-3 mm2 /sec (95% CI 0.13, 0.19). The results were similar across field strengths and timepoint subgroups. Reproducibility was excellent: interreader ICC = 0.92 (95% CI 0.80, 0.97) and intrareader ICC = 0.91 (95% CI 0.78, 0.96). DATA CONCLUSION: Breast tumor ADC can be measured with excellent repeatability and reproducibility in a multi-institution setting using a standardized protocol and QA procedure. Improvements to DWI image quality could reduce loss of data in clinical trials. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;49:1617-1628.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Mama/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética , Neoplasias/diagnóstico por imagen , Adulto , Anciano , Artefactos , Biomarcadores/metabolismo , Neoplasias de la Mama/patología , Quimioterapia Adyuvante , Ensayos Clínicos como Asunto , Medios de Contraste , Femenino , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Persona de Mediana Edad , Terapia Neoadyuvante , Variaciones Dependientes del Observador , Estudios Prospectivos , Garantía de la Calidad de Atención de Salud , Control de Calidad , Receptor ErbB-2/metabolismo , Reproducibilidad de los Resultados , Relación Señal-Ruido
19.
J Comput Assist Tomogr ; 43(1): 85-92, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30052617

RESUMEN

OBJECTIVES: The aims of this study were to identify optimal quantitative breast magnetic resonance imaging background parenchymal enhancement (BPE) parameters associated with breast cancer risk and compare performance to qualitative assessments. METHODS: Using a matched case-control cohort of 46 high-risk women who underwent screening magnetic resonance imaging (23 who developed breast cancer matched to 23 who did not), fibroglandular tissue area, BPE area, and intensity metrics (mean, SD, quartiles, skewness, and kurtosis) were quantitatively measured at varying enhancement thresholds. Optimal thresholds for discriminating between cancer and control cohorts were identified for each metric and performance summarized using area under the receiver operating characteristic curve. RESULTS: Women who developed breast cancer exhibited greater BPE area (adjusted P = 0.004) and higher intensity statistics (adjusted P < 0.004, except skewness and kurtosis with P > 0.99) than did control subjects, with areas under the receiver operating characteristic curve ranging from 0.75 to 0.78 at optimized thresholds. CONCLUSIONS: Elevated quantitative BPE parameters, related to both area and intensity of enhancement, are associated with breast cancer development.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Mama/diagnóstico por imagen , Estudios de Casos y Controles , Estudios de Cohortes , Estudios de Evaluación como Asunto , Femenino , Humanos , Persona de Mediana Edad , Riesgo
20.
Breast Cancer Res ; 20(1): 58, 2018 06 19.
Artículo en Inglés | MEDLINE | ID: mdl-29921323

RESUMEN

BACKGROUND: Numerous studies have analyzed associations between apparent diffusion coefficient (ADC) and histopathological features such as Ki-67 proliferation index in breast cancer (BC), with mixed results. The purpose of this study was to perform a multicenter analysis to determine relationships between ADC and expression of Ki-67 and tumor grade in BC. METHODS: For this study, data from six centers were acquired. The sample comprises 870 patients (all female; mean age, 52.6 ± 10.8 years). In every case, breast magnetic resonance imaging with diffusion-weighted imaging was performed. The comparison of ADC values in groups was performed by Mann-Whitney U test where the p values are adjusted for multiple testing (Bonferroni correction). The association between ADC and Ki-67 values was calculated by Spearman's rank correlation coefficient. Sensitivity, specificity, negative and positive predictive values, accuracy, and AUC were calculated for the diagnostic procedures. ADC thresholds were chosen to maximize the Youden index. RESULTS: Overall, data of 870 patients were acquired for this study. The mean ADC value of the tumors was 0.98 ± 0.22 × 10- 3 mm2 s- 1. ROC analysis showed that it is impossible to differentiate high/moderate grade tumors from grade 1 lesions using ADC values. Youden index identified a threshold ADC value of 1.03 with a sensitivity of 56.2% and specificity of 67.9%. The positive predictive value was 18.2%, and the negative predictive value was 92.4%. The level of the Ki-67 proliferation index was available for 845 patients. The mean value was 12.33 ± 21.77%. ADC correlated with weak statistical significant with expression of Ki-67 (p = - 0.202, p < 0.001). ROC analysis was performed to distinguish tumors with high proliferative potential from tumors with low expression of Ki-67 using ADC values. Youden index identified a threshold ADC value of 0.91 (sensitivity 64%, specificity 50%, positive predictive value 67.7%, negative predictive value 45.0%). CONCLUSIONS: ADC cannot be used as a surrogate marker for proliferation activity and/or for tumor grade in breast cancer.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/genética , Imagen de Difusión por Resonancia Magnética , Antígeno Ki-67/genética , Adulto , Anciano , Neoplasias de la Mama/fisiopatología , Proliferación Celular/genética , Femenino , Humanos , Persona de Mediana Edad , Clasificación del Tumor , Estadísticas no Paramétricas
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda