Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Acta Radiol ; 50(2): 181-93, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19169917

RESUMEN

BACKGROUND: In diagnosing acute pulmonary embolism (PE) in azotemic patients, scintigraphy and magnetic resonance imaging are frequently inconclusive or not available in many hospitals. Computed tomography is readily available, but relatively high doses (30-50 g I) of potentially nephrotoxic iodine contrast media (CM) are used. PURPOSE: To report on the diagnostic quality and possible contrast-induced nephropathy (CIN) after substantially reduced CM doses to diagnose PE in azotemic patients using 80-peak kilovoltage (kVp) 16-row multidetector computed tomography (MDCT) combined with CM doses tailored to body weight, fixed injection duration adapted to scan time, automatic bolus tracking, and saline chaser. MATERIAL AND METHODS: Patients with estimated glomerular filtration rate (eGFR) <50 ml/min were scheduled to undergo 80-kVp MDCT using 200 mg I/kg, and those with eGFR >or=50 ml/min, 120-kVp MDCT with 320 mg I/kg. Both protocols used an 80-kg maximum dose weight and a fixed 15-s injection time. Pulmonary artery density and contrast-to-noise ratio were measured assuming 70 Hounsfield units (HU) for a fresh clot. CIN was defined as a plasma creatinine rise >44.2 micromol/l from baseline. RESULTS: 89/148 patients (63/68 females) underwent 80-/120-kVp protocols, respectively, with 95% of the examinations being subjectively excellent or adequate. Mean values in the 80-/120-kVp cohorts regarding age were 82/65 years, body weight 66/78 kg, effective mAs 277/117, CM dose 13/23 g I, pulmonary artery density 359/345 HU, image noise (1 standard deviation) 24/21 HU, contrast-to-noise ratio 13/13, and dose-length product 173/258 mGy x cm. Only 1/65 and 2/119 patients in the 80- and 120-kVp cohorts, respectively, with negative CT and no anticoagulation suffered non-fatal thromboembolism during 3-month follow-up. No patient developed CIN. CONCLUSION: 80-kVp 16-row MDCT with optimization of injection parameters may be performed with preserved diagnostic quality, using markedly reduced CM doses compared with common routine practice, which should be to the benefit of patients at risk of CIN.


Asunto(s)
Azotemia/complicaciones , Medios de Contraste/administración & dosificación , Embolia Pulmonar/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Ácidos Triyodobenzoicos/administración & dosificación , Enfermedad Aguda , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Modelos Lineales , Masculino , Persona de Mediana Edad , Interpretación de Imagen Radiográfica Asistida por Computador , Estudios Retrospectivos
2.
Angiology ; 50(1): 31-6, 1999 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-9924886

RESUMEN

Ultrasound is sometimes employed as an alternative technique to phlebography in the diagnosis of deep venous thromboses (DVT). To evaluate the efficacy of ultrasound, 74 patients suspected of DVT in the lower limbs were examined with both ultrasound and phlebography. The results indicate that positive reports following ultrasound examination are reliable but that negative reports are not very dependable. The authors urge, therefore, a degree of caution before ultrasound is introduced as a routine method in hospital care.


Asunto(s)
Trombosis de la Vena/diagnóstico , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Pierna/irrigación sanguínea , Masculino , Persona de Mediana Edad , Flebografía , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Ultrasonografía , Trombosis de la Vena/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda