Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Phys Rev Lett ; 132(3): 035101, 2024 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-38307081

RESUMEN

Magnetic reconnection is a ubiquitous and fundamental process in plasmas by which magnetic fields change their topology and release magnetic energy. Despite decades of research, the physics governing the reconnection process in many parameter regimes remains controversial. Contemporary reconnection theories predict that long, narrow current sheets are susceptible to the tearing instability and split into isolated magnetic islands (or plasmoids), resulting in an enhanced reconnection rate. While several experimental observations of plasmoids in the regime of low-to-intermediate ß (where ß is the ratio of plasma thermal pressure to magnetic pressure) have been made, there is a relative lack of experimental evidence for plasmoids in the high-ß reconnection environments which are typical in many space and astrophysical contexts. Here, we report strong experimental evidence for plasmoid formation in laser-driven high-ß reconnection experiments.

2.
Rev Sci Instrum ; 95(10)2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-39360876

RESUMEN

Measurement of proton spectra is an important diagnostic for a variety of high energy density physics experiments. Current diagnostics are either not designed to capture the spectrum of low-energy protons or are unsuitable for high debris experiments. To bridge the gap, a new CR-39 based compact magnetic spectrometer (MagSpec) has been developed to measure proton spectra in the 1-20 MeV energy range, with a particular focus on the low-energy (1-6 MeV) spectrum, for use in experiments at the OMEGA Laser Facility and the National Ignition Facility (NIF). In the MagSpec diagnostic, protons of different energies are dispersed as they pass through a magnetic field before impinging on a differentially filtered CR-39 surface, resulting in a spatial distribution of CR-39 tracks that corresponds to the energy spectrum. In this paper, we discuss details of the design and implementation of MagSpec on the NIF and OMEGA.

3.
Rev Sci Instrum ; 95(9)2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-39315911

RESUMEN

Image plates (IPs), or phosphor storage screens, are a technology employed frequently in inertial confinement fusion (ICF) and high energy density plasma (HEDP) diagnostics because of their sensitivity to many types of radiation, including, x rays, protons, alphas, beta particles, and neutrons. Prior studies characterizing IPs are predicated on the signal level remaining below the scanner saturation threshold. Since the scanning process removes some signal from the IP via photostimulated luminescence, repeatedly scanning an IP can bring the signal level below the scanner saturation threshold. This process, in turn, raises concerns about the signal response of IPs after an arbitrary number of scans and whether such a process yields, for example, a constant ratio of signal between the nth and n + 1st scan. Here, the sensitivity of IPs is investigated when scanned multiple times. It is demonstrated that the ratio of signal decay is not a constant with the number of scans and that the signal decay depends on the x-ray energy. As such, repeatedly scanning an IP with a mixture of signal types (e.g., x ray, neutron, and protons) enables ICF and HEDP diagnostics employing IPs to better isolate a particular signal type.

4.
Rev Sci Instrum ; 95(9)2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-39315912

RESUMEN

Image plates (IPs) are a quickly recoverable and reusable radiation detector often used to measure proton and x-ray fluence in laser-driven experiments. Recently, IPs have been used in a proton radiography detector stack on the OMEGA laser, a diagnostic historically implemented with CR-39, or radiochromic film. The IPs used in this and other diagnostics detect charged particles, neutrons, and x-rays indiscriminately. IPs detect radiation using a photo-stimulated luminescence (PSL) material, often phosphor, in which electrons are excited to metastable states by ionizing radiation. Protons at MeV energies deposit energy deeper into the IP compared with x rays below ∼20 keV due to the Bragg peak present for protons. This property is exploited to discriminate between radiation types. Doses of mono-energetic protons between 1.7 and 14 MeV are applied to IPs using the MIT linear electrostatic ion accelerator. This paper presents the results from consecutive scans of IPs irradiated with different proton energies. The PSL ratios between subsequent scans are shown to depend on proton energy, with higher energy protons having lower PSL ratios for each scan. This finding is separate from the known energy dependence in the absolute sensitivity of IPs. The results can be compared to complimentary work on x rays, showing a difference between protons and x rays, forging a path to discriminate between proton and x-ray fluence in mixed radiation environments.

5.
Rev Sci Instrum ; 95(9)2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-39302171

RESUMEN

Radiochromic film (RCF) and image plates (IPs) are both commonly used detectors in diagnostics fielded at inertial confinement fusion (ICF) and high-energy-density physics (HEDP) research facilities. Due to the intense x-ray background in all ICF/HEDP experiments, accurately calibrating the optical density of RCF as a function of x-ray dose, and the photostimulated luminescence per photon of IPs as a function of x-ray energy, is necessary for interpreting experimental results. Various measurements of the sensitivity curve of different IPs to x rays have been performed [Izumi et al., Proc. SPIE 8850, 885006 (2013) and Rosenberg et al., Rev. Sci. Instrum. 90(1), 013506 (2019)]; however, calibrating RCF is a tedious process that depends on factors such as the orientation in which the RCF is scanned in the film scanner and the batch of RCF used. These issues can be mitigated by cross-calibrating RCF with IPs to enable the use of IPs for the determination of dose on the RCF without scanning the RCF. Here, the first cross-calibration of RCF with IPs to quasi-monoenergetic titanium, copper, and molybdenum K-line x rays is presented. It is found that the IP-inferred dose rates on the RCF for the Ti and Mo x rays agree well with the measured dose rates, while the IP-inferred dose rate for the Cu x rays is larger than the measured dose rate by ∼2×. Explanations for this discrepancy and plans for future work are discussed.

6.
Rev Sci Instrum ; 95(10)2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-39356191

RESUMEN

This paper reports on investigations on the impact of higher neutron fluences on the detection efficiency of protons with CR-39, a charged particle track detector. CR-39 is widely used as a diagnostic for inertial fusion applications and is an integral component of numerous particle diagnostics at the OMEGA laser facility and National Ignition Facility. As experiments continue to produce higher and higher yields, existing diagnostics are impacted by higher particle fluences than they were originally designed for. This paper presents data from experiments measuring proton signal on pieces of CR-39 with different levels of neutron fluence with two different etch times. The experiments show a decrease in signal recovery with increased neutron fluence, which is exacerbated at longer etch times. At 3 h etch time, data suggest a 17% ± 7% signal loss at 1.3 × 105 neutron-induced tracks per cm2 and a 67% ± 21% loss at 6 h etch time. Careful signal isolation techniques can recover most of the proton tracks even with moderate neutron fluence.

7.
Rev Sci Instrum ; 94(3): 033510, 2023 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-37012781

RESUMEN

The Particle Time of Flight (PTOF) diagnostic is a chemical vapor deposition diamond detector used for measuring multiple nuclear bang times at the National Ignition Facility. Due to the non-trivial, polycrystalline structure of these detectors, individual characterization and measurement are required to interrogate the sensitivity and behavior of charge carriers. In this paper, a process is developed for determining the x-ray sensitivity of PTOF detectors and relating it to the intrinsic properties of the detector. We demonstrate that the diamond sample measured has a significant non-homogeneity in its properties, with the charge collection well described by a linear model ax + b, where a = 0.63 ± 0.16 V-1 mm-1 and b = 0.00 ± 0.04 V-1. We also use this method to confirm an electron to hole mobility ratio of 1.5 ± 1.0 and an effective bandgap of 1.8 eV rather than the theoretical 5.5 eV, leading to a large sensitivity increase.

8.
Phys Rev E ; 105(6): L063202, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35854613

RESUMEN

In laser-produced high-energy-density plasmas, large-scale strong magnetic fields are spontaneously generated by the Biermann battery effects when temperature and density gradients are misaligned. Saturation of the magnetic field takes place when convection and dissipation balance field generation. While theoretical and numerical modeling provide useful insight into the saturation mechanisms, experimental demonstration remains elusive. In this letter, we report an experiment on the saturation dynamics and scaling of Biermann battery magnetic field in the regime where plasma convection dominates. With time-gated charged-particle radiography and time-resolved Thomson scattering, the field structure and evolution as well as corresponding plasma conditions are measured. In these conditions, the spatially resolved magnetic fields are reconstructed, leading to a picture of field saturation with a scaling of B∼1/L_{T} for a convectively dominated plasma, a regime where the temperature gradient scale (L_{T}) exceeds the ion skin depth.

9.
Rev Sci Instrum ; 93(10): 103538, 2022 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-36319383

RESUMEN

Electron-temperature (Te) measurements in implosions provide valuable diagnostic information, as Te is negligibly affected by residual flows and other non-thermal effects unlike ion-temperature inferred from a fusion product spectrum. In OMEGA cryogenic implosions, measurement of Te(t) can be used to investigate effects related to time-resolved hot-spot energy balance. The newly implemented phase-2 Particle X-ray Temporal Diagnostic (PXTD) utilizes four fast-rise (∼15 ps) scintillator-channels with distinct x-ray filtering. Titanium and stepped aluminum filtering were chosen to maximize detector sensitivity in the 10-20 keV range, as it has been shown that these x rays have similar density and temperature weighting to the emitted deuterium-tritium fusion neutrons (DTn) from OMEGA Cryo-DT implosions. High quality data have been collected from warm implosions at OMEGA. These data have been used to infer spatially integrated Te(t) with <10% uncertainty at peak emission. Nuclear and x-ray emission histories are measured with 10 ps relative timing uncertainty for x rays and DTn and 12 ps for x rays and deuterium-He3 protons (D3Hep). A future upgrade to the system will enable spatially integrated Te(t) with 40 ps time-resolution from cryogenic DT implosions.

10.
Rev Sci Instrum ; 93(11): 113534, 2022 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-36461490

RESUMEN

Charged particle spectrometry is a critical diagnostic to study inertial-confinement-fusion plasmas and high energy density plasmas. The OMEGA Laser Facility has two fixed magnetic charged particle spectrometers (CPSs) to measure MeV-ions. In situ calibration of these spectrometers was carried out using 241Am and 226Ra alpha emitters. The alpha emission spectrum from the sources was measured independently using surface-barrier detectors (SBDs). The energy dispersion and broadening of the CPS systems were determined by comparing the CPS measured alpha spectrum to that of the SBD. The calibration method significantly constrains the energy dispersion, which was previously obtained through the measurement of charged particle fusion products. Overall, a small shift of 100 keV was observed between previous and the calibration done in this work.

11.
Rev Sci Instrum ; 92(1): 013504, 2021 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-33514215

RESUMEN

This paper presents data from experiments with protons at non-normal incidence to CR-39 nuclear track detectors, analyzing the properties of detection efficiency, proton track diameter, track contrast, and track eccentricity. Understanding the CR-39 response to protons incident at an angle is important for designing charged particle detectors for inertial confinement fusion (ICF) applications. This study considers protons with incident energies less than 3 MeV. In this regime, an incident angle of 10° has no effect on CR-39 detection efficiency, and >85% detection efficiency is preserved up through 25° in the range of 1.0 MeV-2.1 MeV. For ICF applications, incident angles above 30° are deemed impractical for detector design due to significant drops in proton detection at all energies. We observe significant reductions in detection efficiency compared to theoretical predictions, particularly at low energies where proton tracks are etched away. The proton track diameter measured by the scan system is observed to decrease with higher incident angles. The track diameters are analyzed with two fitting models, and it is shown that the diameter-energy relation can be fit with the existing models at angles up to 30°. The optical contrast of the tracks tends to increase with the angle, meaning that the tracks are fainter, and a larger increase is observed for higher energies. Eccentricity, a measure of how elongated proton tracks are, increases with the incident angle and drops after the critical angle. The lowest energy tracks remain nearly circular even at higher angles.

12.
Rev Sci Instrum ; 92(6): 063502, 2021 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-34243553

RESUMEN

We report on the design and implementation of a new system used to characterize the energy-dependent x-ray transmission curve, Θ(E), through filters used in high-energy density physics diagnostics. Using an Amptek X-123-CdTe x-ray spectrometer together with a partially depleted silicon surface barrier detector, both the energy spectrum and total emission of an x-ray source have been accurately measured. By coupling these detectors with a custom PROTO-XRD x-ray source with interchangeable cathodes, accurate characterizations of Θ(E) for filters of varying materials and thicknesses have been obtained. The validity of the technique has been confirmed by accurately reproducing areal densities for high-purity filters with known x-ray transmission properties. In this paper, the experimental setup is described and the results of absorption calibrations performed on a variety of different filters are presented.

13.
Rev Sci Instrum ; 92(8): 083506, 2021 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-34470381

RESUMEN

New designs and a new analysis technique have been developed for an existing compact charged-particle spectrometer on the NIF and OMEGA. The new analysis technique extends the capabilities of this diagnostic to measure arbitrarily shaped ion spectra down to 1 MeV with yields as low as 106. Three different designs are provided optimized for the measurement of DD protons, T3He deuterons, and 3He3He protons. The designs are highly customizable, and a generalized framework is provided for optimizing the design for alternative applications. Additionally, the understanding of the detector's response and uncertainties is greatly expanded upon. A new calibration procedure is also developed to increase the precision of the measurements.

14.
Rev Sci Instrum ; 92(2): 023507, 2021 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-33648078

RESUMEN

Electron-temperature (Te) measurements in implosions provide valuable diagnostic information, as Te is unaffected by residual flows and other non-thermal effects unlike ion temperature inferred from a fusion product spectrum. In OMEGA cryogenic implosions, measurement of Te(t) can be used to investigate effects related to time-resolved hot-spot energy balance. The proposed diagnostic utilizes five fast-rise (∼15 ps) scintillator channels with distinct x-ray filtering. Titanium and stepped aluminum filtering were chosen to maximize detector sensitivity in the 10 keV-20 keV range, as it has been shown that these x rays have similar density and temperature weighting to the emitted deuterium-tritium fusion neutrons. Initial data collected using a prototype nosecone on the existing neutron temporal diagnostic demonstrate the validity of this diagnostic technique. The proposed system will be capable of measuring spatially integrated Te(t) with 20 ps time resolution and <10% uncertainty at peak emission in cryogenic DT implosions.

15.
J Am Soc Mass Spectrom ; 12(5): 599-606, 2001 May.
Artículo en Inglés | MEDLINE | ID: mdl-11349958

RESUMEN

A computer program is described that can rapidly process low-resolution electrospray liquid chromatography/mass spectrometry (LC/MS) for peptides and proteins and assign molecular weights for observed components. The program first analyzes individual scans using a deconvolution algorithm similar to that previously described by Zhang and Marshall. Results for the entire run are then sorted by mass and those values found in adjacent scans are grouped together. The list of found components can also be compared to a user defined list of target molecular weight values making it easy to compare the results from different analyses. The program also has the capability to process a rolling average of scans that improves the performance when analyzing high molecular weight components. Other program features facilitate closer examination of selected spectra or regions of the chromatogram to check the MoWeD mass assignments. The utility of the program was demonstrated by the analysis of LC/MS data derived from a complex mixture of proteins derived from a bacterial whole cell lysate that had previously been analyzed manually. The MoWeD analysis was 30 times faster and provided a more comprehensive list of the components present.


Asunto(s)
Péptidos/análisis , Péptidos/química , Proteínas/análisis , Proteínas/química , Programas Informáticos , Bacillus anthracis/química , Espectrometría de Masas/instrumentación , Espectrometría de Masas/métodos , Peso Molecular , Espectrometría de Masa por Ionización de Electrospray/instrumentación , Espectrometría de Masa por Ionización de Electrospray/métodos
16.
Patient Educ Couns ; 29(2): 167-78, 1996 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-9006233

RESUMEN

Meta-analysis, a quantitative research review, was conducted on 65 studies of the effect of education, exercise and/or psychosocial support (hereafter called psychoeducational care) in adults with chronic obstructive pulmonary disease (COPD). Studies ranged in publication date from 1954 to 1994. Only 34% of studies had subjects that were randomly assigned to treatment condition, and only 15% of studies had a placebo-type control group. Analyses by type of treatment showed that pulmonary rehabilitation (large muscle exercise and education plus a variety of psychosocial or behavioral interventions) had statistically significant beneficial effects on psychological well-being (d+ = 0.58, n = 13), endurance (d+ = 0.77, n = 13), functional status (d+ = 0.63, n = 8), VO2 (d+ = 0.56, n = 5), dyspnea (d+ = 0.71, n = 10), and adherence (d+ = 1.76, n = 2). A statistically significant beneficial effect of pulmonary rehabilitation was not found on Forced Expiratory Volume at 1 s. Across 7 outcomes examined, treatments including education-alone had significant beneficial effect on the accuracy of performing inhaler skills (d+ = 1.27, n = 7). Based on a very small sample of studies, a non-significant but small or medium sized effect of education-alone was evident on health care utilization (d+ = 0.26, n = 3) and on adherence to treatment regimen (d+ = 0.50, n = 2). Such results are inconclusive, suggesting that further research may be indicated. Relaxation-alone had statistically significant beneficial effects on both dyspnea (d+ = 0.91, n = 3) and psychological well-being (d+ = 0.39, n = 6). The research base has methodological weaknesses that should be rectified in future research. Nonetheless, based on the best evidence available to date, identified types of psychoeducational care have been shown to improve the functioning and well-being of adults with COPD.


Asunto(s)
Terapia por Ejercicio , Enfermedades Pulmonares Obstructivas/psicología , Enfermedades Pulmonares Obstructivas/rehabilitación , Educación del Paciente como Asunto/organización & administración , Apoyo Social , Adulto , Servicios de Salud/estadística & datos numéricos , Humanos , Cooperación del Paciente , Proyectos de Investigación , Resultado del Tratamiento
17.
Nurs Clin North Am ; 30(3): 409-20, 1995 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-7567567

RESUMEN

The proliferation of research in nursing is greater today than at any other time in the history of nursing. In order for this research to be meaningful for practice, research utilization efforts are imperative. This article reviews three prominent research utilization models spanning three decades of development. Future challenges and suggestions for improving the process are identified. Through research utilization efforts, nurses are given the power to make informed choices regarding implementation of research-based assessments, diagnoses, interventions, and outcome measures that ultimately will result in improved patient outcomes.


Asunto(s)
Investigación en Enfermería Clínica , Difusión de Innovaciones , Modelos de Enfermería , Humanos , Iowa , Michigan , Atención de Enfermería
18.
Healthy People 2000 Stat Notes ; (19): 1-31, 2000 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-11475488

RESUMEN

The Health Status Indicators (HSIs) were developed as part of the Healthy People 2000 process to facilitate the comparison of health status measures at national, State and local levels. In this report, the number of HSIs where the national target has been attained and the number of HSIs that have improved significantly are enumerated for the United States, the District of Columbia, and each State. Based on data for 1998, the United States had attained targets for 6 of the 17 HSIs with national targets. Twenty-three States had attained targets for 9 or more of the HSIs and 37 States had either attained the target for, or had made significant progress on, at least 12 of the indicators. Substantial progress has therefore been made since the Healthy People 2000 National Health Promotion and Disease Prevention Objectives were published in 1991.


Asunto(s)
Indicadores de Salud , Indicadores de Calidad de la Atención de Salud , Predicción , Encuestas Epidemiológicas , Humanos , Mortalidad , Evaluación de Programas y Proyectos de Salud , Administración en Salud Pública , Indicadores de Calidad de la Atención de Salud/estadística & datos numéricos , Indicadores de Calidad de la Atención de Salud/tendencias , Estados Unidos
19.
AACN Clin Issues Crit Care Nurs ; 5(2): 103-14, 1994 May.
Artículo en Inglés | MEDLINE | ID: mdl-7767804

RESUMEN

Making choices about patient-care interventions pervades critical care nursing practice. Research utilization activities provide the reasoning by which assessment parameters are established, preventative actions are identified, and interventions are evaluated in the clinical setting for positive effects on patient outcomes. For research results to be directly applicable, they must be transformed into clinical innovations specific to a patient population, clinical situation, or institutional setting. A brief summary of using research findings to design clinical innovations is provided. Examples of selected clinical innovations are included to illustrate the steps of the research utilization process. Clinical innovations are intended to improve or validate patient outcomes and are considered the key to quality patient care.


Asunto(s)
Investigación en Enfermería Clínica , Cuidados Críticos/métodos , Difusión de Innovaciones , Humanos , Modelos de Enfermería , Planificación de Atención al Paciente
20.
J Biomol Tech ; 11(3): 135-41, 2000 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-19499049

RESUMEN

Mass spectrometry has become an indispensable analytical tool for studies related to the structure and function of peptides and proteins. The variety of analytical methods, the range of instrument capabilities, and the complexity of the data obtained make it difficult for most laboratories to acquire the necessary expertise to make optimal use of their instrumentation.We describe an expert system approach to automating specific types of analyses in a way that makes it easier to transfer the capability to do specific experiments to other laboratories. Central to the approach is the creation of a computer program (ie, a virtual instrument) that controls the operation of physical components, analyzes incoming data, automatically adjusts instrument parameters to achieve the goal of the analysis, and reports the results. By interacting with the mass spectrometer through the computer operating system, it is possible to add useful functions to the system without altering any of the manufacturer-controlled data system software. The usefulness of this approach is illustrated by the automation of experiments to confirm the sequences of synthetic peptides and perform LC/MS/MS peak parking experiments and real-time database searches.

SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda