Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Más filtros

Banco de datos
Tipo del documento
Publication year range
1.
Phys Rev Lett ; 128(19): 195001, 2022 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-35622043

RESUMEN

The new hohlraum experimental platform and the quasi-3D simulation model are developed to enable the study of the indirect drive experiment using the six-cylinder-port hohlraum for the first time. It is also the first implosion experiment for the six laser-entrance-hole hohlraum to effectively use all the laser beams of the laser facility that is primarily designed for the cylindrical hohlraum. The experiments performed at the 100 kJ Laser Facility produce a peak hohlraum radiation temperature of ∼222 eV for ∼80 kJ and 2 ns square laser pulse. The inferred x-ray conversion efficiency η∼87% is similar to the cylindrical hohlraum and higher than the octahedral spherical hohlraum at the same laser facility, while the low laser backscatter is similar to the outer cone of the cylindrical hohlraum. The hohlraum radiation temperature and M-band (>1.6 keV) flux can be well reproduced by the quasi-3D simulation. The variations of the yield-over-clean and the hot spot shape can also be semiquantitatively explained by the calculated major radiation asymmetry of the quasi-3D simulation. Our work demonstrates the capability for the study of the indirect drive with the six-cylinder-port hohlraum at the cylindrically configured laser facility, which is essential for numerically assessing the laser energy required by the ignition-scale six-cylinder-port hohlraum.

2.
Phys Rev Lett ; 128(7): 075001, 2022 Feb 18.
Artículo en Inglés | MEDLINE | ID: mdl-35244411

RESUMEN

A new method for measuring the time-dependent drive flux at the hohlraum center is proposed as a better alternative to conventional wall-based techniques. The drive flux here is obtained by simultaneous measurement of the reemitted flux and shock velocity from a three-layered "cakelike" sample. With these two independent observables, the influence induced by the uncertainty of the material parameters of the sample can be effectively decreased. The influence from the closure of the laser entrance hole, which was the main challenge in conventional wall-based techniques, was avoided through localized reemitted flux measurement, facilitating drive flux measurement throughout the entire time history. These studies pave a new way for probing the time-dependent drive flux, for both cylindrical hohlraums and novel hohlraums with six laser entrance holes.

3.
Phys Rev Lett ; 127(24): 245001, 2021 Dec 10.
Artículo en Inglés | MEDLINE | ID: mdl-34951808

RESUMEN

In inertial confinement approaches to fusion, the asymmetry of target implosion is a major obstacle to achieving high gain in the laboratory. A recently proposed octahedral spherical hohlraum makes it possible to naturally create spherical target irradiation without supplementary symmetry control. Before any decision is made to pursue an ignition-scale laser system based on the octahedral hohlraum, one needs to test the concept with the existing facilities. Here, we report a proof-of-concept experiment for the novel octahedral hohlraum geometry on the cylindrically configured SGIII laser facility without a symmetry control. All polar and equatorial self-emission images of the compressed target show a near round shape of convergence ratio 15 under both square and shaped laser pulses. The observed implosion performances agree well with the ideal spherical implosion simulation. It also shows limitations with using the existing facilities and adds further weight to the need to move to a spherical port geometry for future ignition laser facilities.

4.
Phys Rev Lett ; 120(16): 165001, 2018 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-29756949

RESUMEN

The first octahedral spherical hohlraum energetics experiment is accomplished at the SGIII laser facility. For the first time, the 32 laser beams are injected into the octahedral spherical hohlraum through six laser entrance holes. Two techniques are used to diagnose the radiation field of the octahedral spherical hohlraum in order to obtain comprehensive experimental data. The radiation flux streaming out of laser entrance holes is measured by six flat-response x-ray detectors (FXRDs) and four M-band x-ray detectors, which are placed at different locations of the SGIII target chamber. The radiation temperature is derived from the measured flux of FXRD by using the blackbody assumption. The peak radiation temperature inside hohlraum is determined by the shock wave technique. The experimental results show that the octahedral spherical hohlraum radiation temperature is in the range of 170-182 eV with drive laser energies of 71 kJ to 84 kJ. The radiation temperature inside the hohlraum determined by the shock wave technique is about 175 eV at 71 kJ. For the flat-top laser pulse of 3 ns, the conversion efficiency of gas-filled octahedral spherical hohlraum from laser into soft x rays is about 80% according to the two-dimensional numerical simulation.

5.
J Org Chem ; 83(3): 1312-1319, 2018 02 02.
Artículo en Inglés | MEDLINE | ID: mdl-29320186

RESUMEN

A microwave-irradiated solvent-free pinacol rearrangement of hydrobenzoin substrates catalyzed by a combination of N-fluorobenzenesulfonimide and FeCl3·6H2O was developed. Its selectivity was first investigated by density functional theory (DFT) calculations. Then the functional group tolerance was examined by synthesizing a series of substrates designed based on the insight provided by the DFT calculations. The application of the methodology was demonstrated by the efficient one-pot synthesis of (±)-latifine and (±)-cherylline, both are 4-aryltetrahydroisoquinoline alkaloids isolated from Amaryllidacecae plants.

6.
Org Biomol Chem ; 16(47): 9147-9151, 2018 12 05.
Artículo en Inglés | MEDLINE | ID: mdl-30465587

RESUMEN

A unique gold(i)-catalyzed 5-endo-dig cyclization/aerobic oxidation cascade strategy from 1,5-enyne substrates with molecular oxygen as the oxidant to yield the indenone was described. The reaction mechanism was studied by heavy atom labelling and some related experiments. This method was applied to the formal total synthesis of isoprekinamycin.

7.
Org Biomol Chem ; 16(40): 7361-7374, 2018 10 17.
Artículo en Inglés | MEDLINE | ID: mdl-30124720

RESUMEN

A multifaceted gold(i)-catalyzed aromaticity-driven double 6-endo cascade cyclization strategy to synthesize both 12H-benzo[a]xanthen-12-ones and benzo[a]acridin-12(7H)-ones, whose core motifs xanthone and acridone both exist as important scaffolds in an immense number of bioactive compounds, was developed. The scopes of this strategy were examined by using a batch of synthetic 1,3-diphenylprop-2-yn-1-one substrates. To probe the mechanism of this cyclization a control experiment for synthesizing intermediates was performed. Thus, a putative mechanism was determined according to this experiment and previous studies.

8.
J Org Chem ; 82(20): 11102-11109, 2017 10 20.
Artículo en Inglés | MEDLINE | ID: mdl-28944672

RESUMEN

A cascade [3,3]-sigmatropic rearrangement/aromatization strategy to the synthesis of 2-(3-methylbenzofuran-2-yl)phenol derivatives was developed and applied to the collective syntheses of seven 2-arylbenzofuran-containing natural products, namely glycybenzofuran, glycyuralin E, lespedezol A1, puerariafuran, 7,2',4'-trihydroxy-3-benzofurancarboxylic acid, coumestrol, and 4'-O-methylcoumestrol. Among them, the total syntheses of glycybenzofuran, glycyuralin E, puerariafuran, 7,2',4'-trihydroxy-3-benzofurancarboxylic acid, and 4'-O-methylcoumestrol were reported for the first time. The practicality of this novel strategy in preparation of the key intermediates was demonstrated by performing the reaction on gram scale and by synthesizing a series of natural products with 2-(3-methylbenzofuran-2-yl)phenol scaffolds in a common strategy.

9.
Phys Rev Lett ; 117(2): 025002, 2016 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-27447512

RESUMEN

The first spherical hohlraum energetics experiment is accomplished on the SGIII-prototype laser facility. In the experiment, the radiation temperature is measured by using an array of flat-response x-ray detectors (FXRDs) through a laser entrance hole at four different angles. The radiation temperature and M-band fraction inside the hohlraum are determined by the shock wave technique. The experimental observations indicate that the radiation temperatures measured by the FXRDs depend on the observation angles and are related to the view field. According to the experimental results, the conversion efficiency of the vacuum spherical hohlraum is in the range from 60% to 80%. Although this conversion efficiency is less than the conversion efficiency of the near vacuum hohlraum on the National Ignition Facility, it is consistent with that of the cylindrical hohlraums used on the NOVA and the SGIII-prototype at the same energy scale.

10.
Phys Rev Lett ; 109(14): 145004, 2012 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-23083253

RESUMEN

The proposal of simultaneously determining the hohlraum peak radiation temperature T(R) and M-band fraction f(M) by shock velocity measurement technique [Y. S. Li et al. Phys. Plasmas 18, 022701 (2011)] is demonstrated for the first time in recent experiments conducted on SGIII-prototype laser facility. In the experiments, T(R) and f(M) are determined by using the observed shock velocities in Al and Ti. For the Au hohlraum used in the experiments, T(R) is about 160 eV and f(M) is around 4.3% under a 1 ns laser pulse of 2 kJ. The results from this method are complementary to those from the broadband x-ray spectrometer, and the technique can be further used to determine T(R) and f(M) inside an ignition hohlraum.

11.
Sci Rep ; 11(1): 14492, 2021 Jul 14.
Artículo en Inglés | MEDLINE | ID: mdl-34262058

RESUMEN

In inertial confinement fusion, quantitative and high-spatial resolution ([Formula: see text]m) measurements of the X-rays self-emitted by the hotspot are critical for studying the physical processes of the implosion stagnation stage. Herein, the 8 ± 0.39-keV monochromatic X-ray distribution from the entire hotspot is quantitatively observed in 5-[Formula: see text]m spatial resolution using a Kirkpatrick-Baez microscope, with impacts from the responses of the diagnosis system removed, for the first time, in implosion experiments at the 100 kJ laser facility in China. Two-dimensional calculations along with 2.5% P2 drive asymmetry and 0.3 ablator self-emission are congruent with the experimental results, especially for the photon number distribution, hotspot profile, and neutron yield. Theoretical calculations enabled a better understanding of the experimental results. Furthermore, the origins of the 17.81% contour profile of the deuterium-deuterium hotspot and the accurate Gaussian source approximation of the core emission area in the implosion capsule are clarified in detail. This work is significant for quantitatively exploring the physical conditions of the hotspot and updating the theoretical model of capsule implosion.

12.
Rev Sci Instrum ; 89(9): 093505, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30278718

RESUMEN

An ultraviolet Thomson-scattering system has been designed and implemented on the Shenguang-III laser facility, a 48-beam, 3ω (351 nm), 180 kJ-level laser driver for high energy density physics and inertial confinement fusion researches. The 4ω (263.3 nm) probe beam of the Thomson-scattering system is injected from the north pole (top) of the target chamber, with an assistant beam-pointing monitor to achieve high pointing accuracy. The Thomson-scattered light is collected by a double-Cassegrain optical transmission system, which provides an achromatic image over a wide wavelength range of 200-800 nm. A novel on-line alignment method is developed and applied to the diagnostic system, ensuring a volumetric positioning accuracy of ∼30 µm for the scattering volume. An online calibration is also conducted to provide the wavelength benchmark and the spectral resolution of the system. This Thomson-scattering system has been tested in a complicated experimental environment with gas-filled hohlraums, and a high-quality ion feature of the scattered light has been obtained.

13.
Rev Sci Instrum ; 89(1): 013501, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29390682

RESUMEN

In laser driven hohlraums, laser beams on the same incident cone may have different beam and plasma conditions, causing beam-to-beam backscatter difference and subsequent azimuthal variations in the x-ray drive on the capsule. To elucidate the large variation of backscatter proportion from beam to beam in some gas-filled hohlraum shots on Shenguang-III, two 28.5° beams have been measured with the Stimulated Raman Scattering (SRS) time-resolved spectra. A bifurcated fiber is used to sample two beams and then coupled to a spectrometer and streak camera combination to reduce the cost. The SRS spectra, characterized by a broad wavelength, were further corrected considering the temporal distortion and intensity modulation caused by components along the light path. This measurement will improve the understanding of the beam propagation inside the hohlraum and related laser plasma instabilities.

14.
Org Lett ; 19(13): 3402-3405, 2017 07 07.
Artículo en Inglés | MEDLINE | ID: mdl-28598637

RESUMEN

The cyclization order of the difunctional 1,2-diphenylethynes was precisely tuned under the catalysis of gold by changing the nitrogen substitution of the substrates, leading to the facile preparation of benzo[a]carbazole and indeno[1,2-c]quinoline derivatives. The mechanisms of these domino cyclizations were probed by control experiments, and an insight into the selectivity of the cyclization was gained by density functional theory (DFT) calculations. This research represents a unified and common method to access benzo[a]carbazoles and indeno[1,2-c]quinolines.

15.
Phys Rev E ; 95(3-1): 031202, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28415291

RESUMEN

Octahedral spherical hohlraums with a single laser ring at an injection angle of 55^{∘} are attractive concepts for laser indirect drive due to the potential for achieving the x-ray drive symmetry required for high convergence implosions. Laser-plasma instabilities, however, are a concern given the long laser propagation path in such hohlraums. Significant stimulated Raman scattering has been observed in cylindrical hohlraums with similar laser propagation paths during the ignition campaign on the National Ignition Facility (NIF). In this Rapid Communication, experiments demonstrating low levels of laser-driven plasma instability (LPI) in spherical hohlraums with a laser injection angle of 55^{∘} are reported and compared to that observed with cylindrical hohlraums with injection angles of 28.5^{∘} and 55^{∘}, similar to that of the NIF. Significant LPI is observed with the laser injection of 28.5^{∘} in the cylindrical hohlraum where the propagation path is similar to the 55^{∘} injection angle for the spherical hohlraum. The experiments are performed on the SGIII laser facility with a total 0.35-µm incident energy of 93 kJ in a 3 nsec pulse. These experiments demonstrate the role of hohlraum geometry in LPI and demonstrate the need for systematic experiments for choosing the optimal configuration for ignition studies with indirect drive inertial confinement fusion.

16.
Chem Commun (Camb) ; 52(37): 6233-6, 2016 05 07.
Artículo en Inglés | MEDLINE | ID: mdl-26979089

RESUMEN

A gold(i)-catalyzed substituent-controlled strategy for the stereoselective synthesis of bicyclic furan and pyran derivatives has been developed. The mechanisms of the reactions have been studied thoroughly by deuterium labelling experiments. The applications of the methodologies were demonstrated by evaluating the preliminary anti-fungal activity of the synthetic compounds.

17.
Org Lett ; 18(4): 680-3, 2016 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-26841301

RESUMEN

A unique strategy for the regiospecific synthesis of bicyclic furopyran derivatives has been developed via a gold(I)-catalyzed propargyl-Claisen rearrangement/6-endo-trig cyclization of propargyl vinyl ethers. The introduction of angle strain into the substrates significantly altered the reaction's regioselectivity. Insight into the regioselectivity of the cycloisomerization was obtained with density functional theory calculations.

18.
Rev Sci Instrum ; 82(10): 103108, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22047281

RESUMEN

A study was conducted with a line-imaging velocity interferometer on sandwich targets at the Shen Guang-III prototype laser facility in China, with the goal of eliminating the preheat effect. A sandwich target structure was used to reduce the x-ray preheat limitation (radiation temperature ~170 eV) in a radiative drive shock experiment. With a thick ablator, the preheat effect appeared before the shock arrived at the window. After adding a shield layer of high-Z material on the ablator, x-rays which penetrated the ablator were so weak that the blank-out effect could not be measured. This experiment indicates that the sandwich target may provide a valuable technique in experiments such as equation of state and shock timing for inertial confinement fusion studies.

19.
Rev Sci Instrum ; 82(11): 113501, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22128970

RESUMEN

Streak camera is widely used in continuous time diagnostics in fast physical process. To produce accurate result, it requires delicate calibration and a reliable analysis method. High quality sweep-rate data with uncertainty smaller than 0.5% are obtained over the full record area by a constrained fitting method of peak position measurement, with a short pulse laser and an etalon as the fiducial source. The temporal response is linearized by this full-screen sweep-rate data, which eliminates errors in measurement due to nonlinearity and space-distortion inherent in streak camera.

SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda