Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
Europace ; 26(7)2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38938169

RESUMEN

AIMS: Subclinical atrial fibrillation (AF) is associated with increased risk of progression to clinical AF, stroke, and cardiovascular death. We hypothesized that in pacemaker patients requiring dual-chamber rate-adaptive (DDDR) pacing, closed loop stimulation (CLS) integrated into the circulatory control system through intra-cardiac impedance monitoring would reduce the occurrence of atrial high-rate episodes (AHREs) compared with conventional DDDR pacing. METHODS AND RESULTS: Patients with sinus node dysfunctions (SNDs) and an implanted pacemaker or defibrillator were randomly allocated to dual-chamber CLS (n = 612) or accelerometer-based DDDR pacing (n = 598) and followed for 3 years. The primary endpoint was time to the composite endpoint of the first AHRE lasting ≥6 min, stroke, or transient ischaemic attack (TIA). All AHREs were independently adjudicated using intra-cardiac electrograms. The incidence of the primary endpoint was lower in the CLS arm (50.6%) than in the DDDR arm (55.7%), primarily due to the reduction in AHREs lasting between 6 h and 7 days. Unadjusted site-stratified hazard ratio (HR) for CLS vs. DDDR was 0.84 [95% confidence interval (CI), 0.72-0.99; P = 0.035]. After adjusting for CHA2DS2-VASc score, the HR remained 0.84 (95% CI, 0.71-0.99; P = 0.033). In subgroup analyses of AHRE incidence, the incremental benefit of CLS was greatest in patients without atrioventricular block (HR, 0.77; P = 0.008) and in patients without AF history (HR, 0.73; P = 0.009). The contribution of stroke/TIA to the primary endpoint (1.3%) was low and not statistically different between study arms. CONCLUSION: Dual-chamber CLS in patients with SND is associated with a significantly lower AHRE incidence than conventional DDDR pacing.


Asunto(s)
Fibrilación Atrial , Estimulación Cardíaca Artificial , Frecuencia Cardíaca , Ataque Isquémico Transitorio , Marcapaso Artificial , Síndrome del Seno Enfermo , Accidente Cerebrovascular , Humanos , Femenino , Masculino , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Fibrilación Atrial/epidemiología , Anciano , Síndrome del Seno Enfermo/terapia , Síndrome del Seno Enfermo/fisiopatología , Estimulación Cardíaca Artificial/métodos , Ataque Isquémico Transitorio/prevención & control , Ataque Isquémico Transitorio/epidemiología , Persona de Mediana Edad , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/epidemiología , Incidencia , Resultado del Tratamiento , Factores de Tiempo , Factores de Riesgo , Desfibriladores Implantables , Técnicas Electrofisiológicas Cardíacas , Acelerometría , Anciano de 80 o más Años
2.
J Cardiovasc Electrophysiol ; 34(4): 947-956, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36709469

RESUMEN

INTRODUCTION: Thoracic impedance (TI) drops measured by implantable cardioverter-defibrillators (ICDs) have been reported to correlate with ventricular tachycardia/fibrillation (VT/VF). The aim of our study was to assess the temporal association of decreasing TI trends with VT/VF episodes through a longitudinal analysis of daily remote monitoring data from ICDs and cardiac resynchronization therapy defibrillators (CRT-Ds). METHODS AND RESULTS: Retrospective data from 2384 patients were randomized 1:1 into a derivation or validation cohort. The TI decrease rate was defined as the percentage of rolling weeks with a continuously decreasing TI trend. The derivation cohort was used to determine a TI decrease rate threshold for a ≥99% specificity of arrhythmia prediction. The associated risk of VT/VF episodes was estimated in the validation cohort by dividing the available follow-up into 60-day assessment intervals. Analyses were performed separately for 1354 ICD and 1030 CRT-D patients. During a median follow-up of 2.0 years, 727 patients (30.4%) experienced 3298 confirmed VT/VF episodes. In the ICD group, a TI decrease rate of >60% was associated with a higher risk of VT/VF episode in a 60-day assessment interval (stratified hazard ratio, 1.42; 95% confidence interval (CI), 1.05-1.92; p = .023). The TI decrease preceded (40.8%) or followed (59.2%) the VT/VF episodes. In the CRT-D group, no association between TI decrease and VT/VF episodes was observed (p = .84). CONCLUSION: In our longitudinal analysis, TI decrease was associated with VT/VF episodes only in ICD patients. Preventive interventions may be difficult since episodes can occur before or after TI decrease.


Asunto(s)
Arritmias Cardíacas , Taquicardia Ventricular , Humanos , Arritmias Cardíacas/terapia , Impedancia Eléctrica , Estudios Retrospectivos , Fibrilación Ventricular , Desfibriladores Implantables
3.
Europace ; 25(5)2023 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-36932709

RESUMEN

AIMS: In subcutaneous implantable cardioverter defibrillator (S-ICD) recipients, the UNTOUCHED study demonstrated a very low inappropriate shock rate on programming a conditional zone between 200 and 250 bpm and a shock zone for arrhythmias >250 bpm. The extent to which this programming approach is adopted in clinical practice is still unknown, as is its impact on the rates of inappropriate and appropriate therapies. METHODS AND RESULTS: We assessed ICD programming on implantation and during follow-up in a cohort of 1468 consecutive S-ICD recipients in 56 Italian centres. We also measured the occurrence of inappropriate and appropriate shocks during follow-up. On implantation, the median programmed conditional zone cut-off was set to 200 bpm (IQR: 200-220) and the shock zone cut-off was 230 bpm (IQR: 210-250). During follow-up, the conditional zone cut-off rate was not significantly changed, while the shock zone cut-off was changed in 622 (42%) patients and the median value increased to 250 bpm (IQR: 230-250) (P < 0.001). UNTOUCHED-like programming of detection cut-offs was adopted in 426 (29%) patients immediately after device implantation, and in 714 (49%, P < 0.001) at the last follow-up. UNTOUCHED-like programming was independently associated with fewer inappropriate shocks (hazard ratio 0.50, 95%CI 0.25-0.98, P = 0.044), and had no impact on appropriate and ineffective shocks. CONCLUSIONS: In recent years, S-ICD implanting centres have increasingly programmed high arrhythmia detection cut-off rates, at the time of implantation in the case of new S-ICD recipients, and during follow-up in the case of pre-existing implants. This has contributed significantly to reducing the incidence of inappropriate shocks in clinical practice. Rordorf: Programming of the S-ICD. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Asunto(s)
Desfibriladores Implantables , Taquicardia Ventricular , Humanos , Desfibriladores Implantables/efectos adversos , Taquicardia Ventricular/diagnóstico , Estudios de Seguimiento , Estudios Prospectivos , Cardioversión Eléctrica , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia
4.
Europace ; 25(6)2023 06 02.
Artículo en Inglés | MEDLINE | ID: mdl-37350404

RESUMEN

AIMS: Subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy is expanding rapidly. However, there are few data on the S-ICD extraction procedure and subsequent patient management. The aim of this analysis was to describe the procedure, management, and outcome of S-ICD extractions in clinical practice. METHODS AND RESULTS: We enrolled consecutive patients who required complete S-ICD extraction at 66 Italian centres. From 2013 to 2022, 2718 patients undergoing de novo implantation of an S-ICD were enrolled. Of these, 71 required complete S-ICD system extraction (17 owing to infection). The S-ICD system was successfully extracted in all patients, and no complications were reported; the median procedure duration was 40 (25th-75th percentile: 20-55) min. Simple manual traction was sufficient to remove the lead in 59 (84%) patients, in whom lead-dwelling time was shorter [20 (9-32) months vs. 30 (22-41) months; P = 0.032]. Hospitalization time was short in the case of both non-infectious [2 (1-2) days] and infectious indications [3 (1-6) days]. In the case of infection, no patients required post-extraction intravenous antibiotics, the median duration of any antibiotic therapy was 10 (10-14) days, and the re-implantation was performed during the same procedure in 29% of cases. No complications arose over a median of 21 months. CONCLUSION: The S-ICD extraction was safe and easy to perform, with no complications. Simple traction of the lead was successful in most patients, but specific tools could be needed for systems implanted for a longer time. The peri- and post-procedural management of S-ICD extraction was free from complications and not burdensome for patients and healthcare system. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Asunto(s)
Desfibriladores Implantables , Humanos , Administración Intravenosa , Antibacterianos , Hospitalización , Resultado del Tratamiento
5.
Europace ; 25(4): 1423-1431, 2023 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-36794691

RESUMEN

AIMS: A previous randomized study demonstrated that the subcutaneous implantable cardioverter defibrillator (S-ICD) was noninferior to transvenous ICD with respect to device-related complications and inappropriate shocks. However, that was performed prior to the widespread adoption of pulse generator implantation in the intermuscular (IM) space instead of the traditional subcutaneous (SC) pocket. The aim of this analysis was to compare survival from device-related complications and inappropriate shocks between patients who underwent S-ICD implantation with the generator positioned in an IM position in comparison with an SC pocket. METHODS AND RESULTS: We analysed 1577 consecutive patients who had undergone S-ICD implantation from 2013 to 2021 and were followed up until December 2021. Subcutaneous patients (n = 290) were propensity matched with patients of the IM group (n = 290), and their outcomes were compared. : During a median follow-up of 28 months, device-related complications were reported in 28 (4.8%) patients and inappropriate shocks were reported in 37 (6.4%) patients. The risk of complication was lower in the matched IM group than in the SC group [hazard ratio 0.41, 95% confidence interval (CI) 0.17-0.99, P = 0.041], as well as the composite of complications and inappropriate shocks (hazard ratio 0.50, 95% CI 0.30-0.86, P = 0.013). The risk of appropriate shocks was similar between groups (hazard ratio 0.90, 95% CI 0.50-1.61, P = 0.721). There was no significant interaction between generator positioning and variables such as gender, age, body mass index, and ejection fraction. CONCLUSION: Our data showed the superiority of the IM S-ICD generator positioning in reducing device-related complications and inappropriate shocks. CLINICAL TRIAL REGISTRATION: Clinical Trial Registration: ClinicalTrials.gov; NCT02275637.


Asunto(s)
Desfibriladores Implantables , Humanos , Desfibriladores Implantables/efectos adversos , Estudios de Casos y Controles , Muerte Súbita Cardíaca/etiología , Estudios Retrospectivos , Resultado del Tratamiento
6.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37536671

RESUMEN

AIMS: Patients with cardiomyopathies and channelopathies are usually younger and have a predominantly arrhythmia-related prognosis; they have nearly normal life expectancy thanks to the protection against sudden cardiac death provided by the implantable cardioverter defibrillator (ICD). The subcutaneous ICD (S-ICD) is an effective alternative to the transvenous ICD and has evolved over the years. This study aimed to evaluate the rate of inappropriate shocks (IS), appropriate therapies, and device-related complications in patients with cardiomyopathies and channelopathies who underwent modern S-ICD implantation. METHODS AND RESULTS: We enrolled consecutive patients with cardiomyopathies and channelopathies who had undergone implantation of a modern S-ICD from January 2016 to December 2020 and who were followed up until December 2022. A total of 1338 S-ICD implantations were performed within the observation period. Of these patients, 628 had cardiomyopathies or channelopathies. The rate of IS at 12 months was 4.6% [95% confidence interval (CI): 2.8-6.9] in patients with cardiomyopathies and 1.1% (95% CI: 0.1-3.8) in patients with channelopathies (P = 0.032). No significant differences were noted over a median follow-up of 43 months [hazard ratio (HR): 0.76; 95% CI: 0.45-1.31; P = 0.351]. The rate of appropriate shocks at 12 months was 2.3% (95% CI: 1.1-4.1) in patients with cardiomyopathies and 2.1% (95% CI: 0.6-5.3) in patients with channelopathies (P = 1.0). The rate of device-related complications was 0.9% (95% CI: 0.3-2.3) and 3.2% (95% CI: 1.2-6.8), respectively (P = 0.074). No significant differences were noted over the entire follow-up. The need for pacing was low, occurring in 0.8% of patients. CONCLUSION: Modern S-ICDs may be a valuable alternative to transvenous ICDs in patients with cardiomyopathies and channelopathies. Our findings suggest that modern S-ICD therapy carries a low rate of IS. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Asunto(s)
Cardiomiopatías , Canalopatías , Desfibriladores Implantables , Humanos , Desfibriladores Implantables/efectos adversos , Canalopatías/complicaciones , Canalopatías/terapia , Resultado del Tratamiento , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Cardiomiopatías/complicaciones , Cardiomiopatías/terapia , Sistema de Registros
7.
J Cardiovasc Electrophysiol ; 33(7): 1472-1479, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35499267

RESUMEN

INTRODUCTION: The Respiratory Disturbance Index (RDI) computed by an implantable cardioverter defibrillator (ICD) algorithm accurately identifies severe sleep apnea (SA). In the present analysis, we tested the hypothesis that RDI could also predict atrial fibrillation (AF) burden. METHODS: Patients with ejection fraction ≤35% implanted with an ICD were enrolled and followed up for 24 months. One month after implantation, patients underwent a polysomnographic study. The weekly mean RDI value was considered, as calculated during the entire follow-up period and over a 1-week period preceding the sleep study. The endpoints were as follows: daily AF burden of ≥5 min, ≥6 h, ≥23 h. RESULTS: Here, 164 patients had usable RDI values during the entire follow-up period. Severe SA (RDI ≥ 30 episodes/h) was diagnosed in 92 (56%) patients at the time of the sleep study. During follow-up, AF burden ≥ 5 min/day was documented in 70 (43%), ≥6 h/day in 48 (29%), and ≥23 h/day in 33 (20%) patients. Device-detected RDI ≥ 30 episodes/h at the time of the polygraphy, as well as the polygraphy-measured apnea hypopnea index ≥ 30 episodes/h, were not associated with the occurrence of the endpoints, using a Cox regression model. However, using a time-dependent model, continuously measured weekly mean RDI ≥ 30 episodes/h was independently associated with AF burden ≥ 5 min/day (hazard ratio [HR]: 2.13, 95% confidence interval [CI]: 1.24-3.65, p = .006), ≥6 h/day (HR: 2.75, 95% CI: 1.37-5.49, p = .004), and ≥23 h/day (HR: 2.26, 95% CI: 1.05-4.86, p = .037). CONCLUSIONS: In heart failure patients, ICD-diagnosed severe SA on follow-up data review identifies patients who are from two- to three-fold more likely to experience an AF episode, according to various thresholds of daily AF burden.


Asunto(s)
Fibrilación Atrial , Desfibriladores Implantables , Insuficiencia Cardíaca , Síndromes de la Apnea del Sueño , Algoritmos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Insuficiencia Cardíaca/complicaciones , Humanos , Síndromes de la Apnea del Sueño/complicaciones , Síndromes de la Apnea del Sueño/diagnóstico , Síndromes de la Apnea del Sueño/terapia
8.
Medicina (Kaunas) ; 59(1)2022 Dec 28.
Artículo en Inglés | MEDLINE | ID: mdl-36676690

RESUMEN

Background. Data on leadless pacemaker (LPM) implantation in an emergency setting are currently lacking. Objective. We aimed to investigate the feasibility of LPM implantation for emergency bradyarrhythmia, in patients referred for urgent PM implantation, in a large, multicenter, real-world cohort of LPM recipients. Methods. Two cohorts of LPM patients, stratified according to the LPM implantation scenario (patients admitted from the emergency department (ED+) vs. elective patients (ED−)) were retrieved from the iLEAPER registry. The primary outcome of the study was a comparison of the peri-procedural complications between the groups. The rates of peri-procedural characteristics (overall procedural and fluoroscopic duration) were deemed secondary outcomes. Results. A total of 1154 patients were enrolled in this project, with patients implanted due to an urgent bradyarrhythmia (ED+) representing 6.2% of the entire cohort. Slow atrial fibrillation and complete + advanced atrioventricular blocks were more frequent in the ED+ cohort (76.3% for ED+ vs. 49.7% for ED−, p = 0.025; 37.5% vs. 27.3%, p = 0.027, respectively). The overall procedural times were longer in the ED+ cohort (60 (45−80) mins vs. 50 (40−65) mins, p < 0.001), showing higher rates of temporary pacing (94.4% for ED+ vs. 28.9% for ED−, p < 0.001). Emergency LPM implantation was not correlated with an increase in the rate of major complications compared to the control group (6.9% ED+ vs. 4.2% ED−, p = 0.244). Conclusion. LPM implantation is a feasible procedure for the treatment of severe bradyarrhythmia in an urgent setting. Urgent LPM implantation was not correlated with an increase in the rate of major complications compared to the control group, but it was associated with longer procedural times.


Asunto(s)
Fibrilación Atrial , Marcapaso Artificial , Humanos , Bradicardia/terapia , Fibrilación Atrial/terapia , Resultado del Tratamiento
9.
J Cardiovasc Electrophysiol ; 32(9): 2528-2535, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34252991

RESUMEN

INTRODUCTION: Factors influencing malignant arrhythmia onset are not fully understood. We explored the circadian periodicity of ventricular arrhythmias (VAs) in patients with implantable cardioverter and cardiac resynchronization defibrillators (ICD/CRT-D). METHODS: Time, morphology (monomorphic/polymorphic), and mode of termination (anti-tachycardia pacing [ATP] or shock) of VAs stored in a database of remote monitoring data were adjudicated. Episodes were grouped in six 4-h timeslots from 00:00 to 24:00. Circadian distributions and adjusted marginal odds ratios (ORs), with 95% confidence interval (CI), were analyzed using mixed-effect models and logit generalized estimating equations, respectively, to account for within-subject correlation of multiple episodes. RESULTS: Among 1303 VA episodes from 446 patients (63% ICD and 37% CRT-D), 120 (9%) self-extinguished, and 842 (65%) were terminated by ATP, 343 (26%) by shock. VAs clustered from 08:00 to 16:00 with 44% of episodes, as compared with 22% from 00:00 to 08:00 (p < .001) and 34% from 16:00 to 24:00 (p = .005). Episodes were more likely to be polymorphic at night with an adjusted marginal OR of 1.66 (CI, 1.15-2.40; p = .007) at 00:00-04:00 versus other timeslots. Episodes were less likely to be terminated by ATP in the 00:00-04:00 (success-to-failure ratio, 0.67; CI, 0.46-0.98; p = .039) and 08:00-12:00 (0.70; CI, 0.51-0.96; p = .02) timeslots, and most likely to be terminated by ATP between 12:00 and 16:00 (success-to-failure ratio 1.42; CI, 1.06-1.91; p = .02). CONCLUSION: VAs did not distribute uniformly over the 24 h, with a majority of episodes occurring from 08:00 to 16:00. Nocturnal episodes were more likely to be polymorphic. The efficacy of ATP depended on the time of delivery.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Taquicardia Ventricular , Arritmias Cardíacas , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Resultado del Tratamiento
10.
Int J Clin Pract ; 75(3): e13820, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33164319

RESUMEN

OBJECTIVE: The MINERVA trial showed that in pacemaker patients with atrial fibrillation (AF) history, DDDRP pacing combining three algorithms - (a) atrial antitachycardia pacing with Reactive ATP enabled, (b) atrial preventive pacing and (c) managed ventricular pacing (MVP)-may effectively delay progression to persistent/permanent AF compared with standard DDDR pacing. We performed a comparative non-randomised evaluation to evaluate if Reactive ATP can be the main driver of persistent/permanent AF reduction independently on preventive pacing. METHODS: Thirty-one centres included consecutive dual-chamber pacemaker patients with AF history. Reactive ATP was programmed in all patients while preventive atrial pacing was not enabled. These patients were compared with the three groups of MINERVA randomised trial (Control DDDR, MVP, and DDDRP). The main endpoint was the incidence of AF longer than 7 consecutive days. RESULTS: A total of 146 patients (73 years old, 54% male) were included and followed for a median observation period of 31 months. The 2-year incidence of AF > 7 days was 12% in the Reactive ATP group, very similar to that found in the DDDRP arm of the MINERVA trial (13.8%, P = .732) and significantly lower than AF incidence found in the MINERVA Control DDDR arm (25.8%, P = .012) and in the MINERVA MVP arm (25.9%, P = .025). CONCLUSIONS: In a real-world population of dual-chamber pacemaker patients with AF history, the use of Reactive ATP is associated with a low incidence of persistent AF, highlighting that the positive results of the MINERVA trial were related to the effectiveness of Reactive ATP rather than to preventive pacing.


Asunto(s)
Fibrilación Atrial , Marcapaso Artificial , Anciano , Fibrilación Atrial/prevención & control , Estimulación Cardíaca Artificial , Femenino , Atrios Cardíacos , Humanos , Incidencia , Masculino , Resultado del Tratamiento
11.
Echocardiography ; 38(10): 1821-1827, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34555196

RESUMEN

Left atrial intramural hematoma (LAIH) is an uncommon entity for which a timely diagnosis is critical for decision making. Cardiac surgical or catheter-based procedures are potential causing factors. Though cardiac computerized tomography and magnetic resonance are highly accurate diagnostic modalities, their role is limited by the lack of widespread availability. The present clinical case illustrates the diagnostic features of LAIH that can be obtained using echocardiography at the bedside in critically ill patients. We report a case of LAIH, that followed a catheter ablation procedure and was complicated by cardiac and cerebral ischemia. Cardiac surgical management was required.


Asunto(s)
Apéndice Atrial , Ablación por Catéter , Ecocardiografía , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Hematoma/diagnóstico por imagen , Hematoma/cirugía , Humanos
12.
J Cardiovasc Electrophysiol ; 31(7): 1694-1701, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32369225

RESUMEN

BACKGROUND: Ablation index (AI) is a new lesion quality marker that has been demonstrated to allow a high single-procedure arrhythmia-free survival in single-center studies. This prospective, multi-center study was designed to evaluate the reproducibility of pulmonary vein (PV) isolation guided by the AI. METHODS: A total of 490 consecutive patients with paroxysmal (80.4%) and persistent AF underwent first time PV isolation and were divided in four study groups according to operator's preference in choosing the ablation catheter (a contact force (ST) or contact force surround flow (STSF) catheter) and the AI setting (330-450 or 380-500 at anterior wall or posterior wall, respectively). RESULTS: At 12 months a high rate of freedom from AF recurrences was observed in patients with both paroxysmal and persistent AF (91% vs 83.3%; P = .039). There was no difference in the rate of AF recurrence among the four study groups (4.5% in group ST330-450, 12.2% in group ST 380-500, 14.9% in group STSF330-450, 9.4% in group STSF380-500; P = .083). Recurrence was also similar between patients treated with a ST (8%) or STSF catheter (12.1%; P = .2), and within patients targeting an AI settings of 330 to 450 (10.9%) or 380 to 500 (10.3%; P = .64). In patients with paroxysmal AF, there was no difference (P = .12) in the 1-year freedom from AF recurrence among 14 operators that performed ≥10 ablation procedure. CONCLUSIONS: An ablation protocol respecting strict criteria for contiguity and quality lesion resulted in high rate of 1-year freedom from AF recurrence, irrespective of the ablation catheters, AI settings, and operator.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Humanos , Estudios Prospectivos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Recurrencia , Sistema de Registros , Reproducibilidad de los Resultados , Resultado del Tratamiento
13.
Europace ; 22(12): 1822-1829, 2020 12 23.
Artículo en Inglés | MEDLINE | ID: mdl-33118017

RESUMEN

AIMS: The traditional technique for subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation involves three incisions and a subcutaneous pocket. Recently, a two-incision and intermuscular (IM) technique has been adopted. The PRAETORIAN score is a chest radiograph-based tool that predicts S-ICD conversion testing. We assessed whether the S-ICD implantation technique affects optimal position of the defibrillation system according to the PRAETORIAN score. METHODS AND RESULTS: We analysed consecutive patients undergoing S-ICD implantation. The χ2 test and regression analysis were used to determine the association between the PRAETORIAN score and implantation technique. Two hundred and thirteen patients were enrolled. The S-ICD generator was positioned in an IM pocket in 174 patients (81.7%) and the two-incision approach was adopted in 199 (93.4%). According to the PRAETORIAN score, the risk of conversion failure was classified as low in 198 patients (93.0%), intermediate in 13 (6.1%), and high in 2 (0.9%). Patients undergoing the two-incision and IM technique were more likely to have a low (<90) PRAETORIAN score than those undergoing the three-incision and subcutaneous technique (two-incision: 94.0% vs. three-incision: 78.6%; P = 0.004 and IM: 96.0% vs. subcutaneous: 79.5%; P = 0.001). Intermuscular plus two-incision technique was associated with a low-risk PRAETORIAN score (hazard ratio 3.76; 95% confidence interval 1.01-14.02; P = 0.04). Shock impedance was lower in PRAETORIAN low-risk patients than in intermediate-/high-risk categories (66 vs. 96 Ohm; P = 0.001). The PRAETORIAN score did not predict shock failure at 65 J. CONCLUSION: In this cohort of S-ICD recipients, combining the two-incision technique and IM generator implantation yielded the lowest PRAETORIAN score values, indicating optimal defibrillation system position. CLINICAL TRIAL REGISTRATION: http://clinicaltrials.gov/ Identifier: NCT02275637.


Asunto(s)
Desfibriladores Implantables , Estudios de Cohortes , Impedancia Eléctrica , Humanos , Implantación de Prótesis/efectos adversos , Factores de Riesgo
14.
J Cardiovasc Electrophysiol ; 30(9): 1626-1635, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31165517

RESUMEN

INTRODUCTION: Clinical trials did not provide conclusive evidence concerning the benefit of prophylactic implantable cardioverter-defibrillators (ICDs) in patients with severe nonischemic cardiomyopathy (NICM). We aimed to compare incidence of appropriate sustained ventricular arrhythmia (SVA) and device therapy in ischemic cardiomyopathy (ICM) vs NICM ICD and/or cardiac resynchronization therapy (CRT-D) patients. METHODS AND RESULTS: We analyzed remote-monitoring data from devices of the Home Monitoring Expert Alliance network. SVA recordings were adjudicated by three independent electrophysiologists. Our cohort included 1,946 patients who received either an ICD (55%) or a CRT-D (45%) for primary prevention of sudden cardiac death. Median (interquartile range) age was 70 (62-77) years, 81% were male, and 52% were in the ICM group. Patients were remotely monitored for a maximum follow-up of 5 years. The 5-year product-limit estimate of SVA incidence in patients with an ICD was 47.3% (95% confidence interval [CI], 41.0%-53.9%) in the ICM group and 44.7% (36.9%-53.3%) in the NICM group. In patients with a CRT-D, SVA incidence was 45.7% (37.3%-55.0%) in ICM patients and 49.2% (40.4%-58.7%) in NICM patients. The adjusted hazard ratio for SVA in the ICM vs NICM group was 0.96 (95% CI: 0.70-1.30, P = .77) in ICD patients and 0.85 (95% CI: 0.61-1.18, P = .34) in CRT-D patients. SVAs triggered appropriate device therapies with similar incidence in all groups. CONCLUSION: In a large cohort of remotely monitored ICD and CRT-D recipients, SVA incidence did not significantly differ in ICM and NICM patients.


Asunto(s)
Arritmias Cardíacas/terapia , Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca , Cardiomiopatías/fisiopatología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Prevención Primaria/instrumentación , Tecnología de Sensores Remotos , Anciano , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/fisiopatología , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/mortalidad , Cardiomiopatías/diagnóstico , Cardiomiopatías/mortalidad , Causas de Muerte , Bases de Datos Factuales , Muerte Súbita Cardíaca/epidemiología , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/mortalidad , Femenino , Humanos , Incidencia , Italia/epidemiología , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/mortalidad , Isquemia Miocárdica/fisiopatología , Valor Predictivo de las Pruebas , Falla de Prótesis , Factores de Riesgo , Procesamiento de Señales Asistido por Computador , Factores de Tiempo , Resultado del Tratamiento
15.
Europace ; 21(12): 1890-1899, 2019 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-31665280

RESUMEN

AIMS: Female sex is considered an independent risk factor of transvenous leads extraction (TLE) procedure. The aim of the study was to evaluate the effectiveness of TLE in women compared with men. METHODS AND RESULTS: A post hoc analysis of risk factors and effectiveness of TLE in women and men included in the ESC-EHRA EORP ELECTRa registry was conducted. The rate of major complications was 1.96% in women vs. 0.71% in men; P = 0.0025. The number of leads was higher in men (mean 1.89 vs. 1.71; P < 0.0001) with higher number of abandoned leads in women (46.04% vs. 34.82%; P < 0.0001). Risk factors of TLE differed between the sexes, of which the major were: signs and symptoms of venous occlusion [odds ratio (OR) 3.730, confidence interval (CI) 1.401-9.934; P = 0.0084], cumulative leads dwell time (OR 1.044, CI 1.024-1.065; P < 0.001), number of generator replacements (OR 1.029, CI 1.005-1.054; P = 0.0184) in females and the number of leads (OR 6.053, CI 2.422-15.129; P = 0.0001), use of powered sheaths (OR 2.742, CI 1.404-5.355; P = 0.0031), and white blood cell count (OR 1.138, CI 1.069-1.212; P < 0.001) in males. Individual radiological and clinical success of TLE was 96.29% and 98.14% in women compared with 98.03% and 99.21% in men (P = 0.0046 and 0.0098). CONCLUSION: The efficacy of TLE was lower in females than males, with a higher rate of periprocedural major complications. The reasons for this difference are probably related to disparities in risk factors in women, including more pronounced leads adherence to the walls of the veins and myocardium. Lead management may be key to the effectiveness of TLE in females.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Remoción de Dispositivos , Complicaciones Intraoperatorias/epidemiología , Complicaciones Posoperatorias/epidemiología , Infecciones Relacionadas con Prótesis/terapia , Anciano , Anciano de 80 o más Años , Suministros de Energía Eléctrica , Europa (Continente) , Femenino , Humanos , Recuento de Leucocitos , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Marcapaso Artificial , Sistema de Registros , Factores Sexuales , Factores de Tiempo , Insuficiencia de la Válvula Tricúspide/epidemiología , Trombosis de la Vena/epidemiología
16.
Europace ; 20(6): 1001-1009, 2018 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-29016759

RESUMEN

Aims: The Really ProMRI study evaluates magnetic resonance imaging (MRI) access for patients with cardiac implantable electronic devices (CIEDs) as well as the performance of magnetic resonance (MR)-conditional leads when undergoing MRI. Methods and results: Patients either with an MR-conditional pacemaker or implantable defibrillator (ICD) system or with at least a component (device or one or more leads) from an MR-conditional system, were asked to fill in a questionnaire when they were referred to a MR scan. The rate of prescription, denial, or execution of MR examinations was evaluated in a 1-year follow-up visit. In total, 555 patients [median age (interquartile range) 72.2 (62.2-78.6); 72% male] were enrolled, 49% (270) with a pacemaker, 51% (285) with an ICD system. Five-hundred and ten patients completed the follow-up period. A total of 37 MRI referrals were reported in 35 patients, with a consequent event rate of 7.0/100 patient-years (CI, 4.9-9.7). Fourteen were denied, while 23 [66%; (CI, 48-81%)] were performed. The number of patients with MR referrals was not statistically different between pacemaker and ICD groups (21 vs. 14; P = 0.178). The rate of scans performed was higher in the pacemaker subjects (19/23 vs. 4/14, P = 0.003), while it was similar between patients with or without a complete MR-conditional system (19/30 vs. 4/7, P = 0.606). Conclusion: In this study, we reported a 7.0/100 patient-year's event rate of MR prescriptions in CIED patients. Many examinations were denied, despite MR-conditional systems, especially in ICD patients. Regulatory and cultural changes are needed to allow wider access to MR imaging in CIED patients with MR-conditional systems.


Asunto(s)
Desfibriladores Implantables/estadística & datos numéricos , Imagen por Resonancia Magnética , Marcapaso Artificial/estadística & datos numéricos , Utilización de Procedimientos y Técnicas/estadística & datos numéricos , Anciano , Seguridad de Equipos/métodos , Seguridad de Equipos/normas , Femenino , Conocimientos, Actitudes y Práctica en Salud , Accesibilidad a los Servicios de Salud , Mal Uso de los Servicios de Salud/estadística & datos numéricos , Cardiopatías/terapia , Humanos , Italia , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Sistema de Registros/estadística & datos numéricos
17.
Europace ; 19(11): 1826-1832, 2017 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-28011803

RESUMEN

AIMS: A recommendation for a subcutaneous-implantable cardioverter-defibrillator (S-ICD) has been added to recent European Society of Cardiology Guidelines. However, the S-ICD is not ideally suitable for patients who need pacing. The aim of this survey was to analyse the current practice of ICD implantation and to evaluate the actual suitability of S-ICD. METHODS AND RESULTS: The survey 'S-ICD Why Not?' was an independent initiative taken by the Italian Heart Rhythm Society (AIAC). Clinical characteristics, selection criteria, and factors guiding the choice of ICD type were collected in consecutive patients who underwent ICD implantation in 33 Italian centres from September to December 2015. A cardiac resynchronization therapy (CRT) device was implanted in 39% (369 of 947) of patients undergoing de novo ICD implantation. An S-ICD was implanted in 12% of patients with no CRT indication (62 of 510 with available data). S-ICD patients were younger than patients who received transvenous ICD, more often had channelopathies, and more frequently received their device for secondary prevention of sudden death. More frequently, the clinical reason for preferring a transvenous ICD over an S-ICD was the need for pacing (45%) or for antitachycardia pacing (36%). Nonetheless, only 7% of patients fulfilled conditions for recommending permanent pacing, and 4% of patients had a history of monomorphic ventricular tachycardia that might have been treatable with antitachycardia pacing. CONCLUSION: The vast majority of patients needing ICD therapy are suitable candidates for S-ICD implantation. Nevertheless, it currently seems to be preferentially adopted for secondary prevention of sudden death in young patients with channelopathies.


Asunto(s)
Arritmias Cardíacas/terapia , Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca , Canalopatías , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Prevención Secundaria/instrumentación , Adulto , Anciano , Arritmias Cardíacas/complicaciones , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/genética , Terapia de Resincronización Cardíaca/efectos adversos , Toma de Decisiones Clínicas , Muerte Súbita Cardíaca/etiología , Cardioversión Eléctrica/efectos adversos , Electrocardiografía , Femenino , Encuestas de Atención de la Salud , Humanos , Italia , Masculino , Persona de Mediana Edad , Selección de Paciente , Factores de Riesgo , Resultado del Tratamiento
18.
Europace ; 18(9): 1374-82, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26612878

RESUMEN

AIMS: It is not known whether heart failure (HF) patients with prolonged QRS who undergo cardiac resynchronization therapy combined with a defibrillator (CRT-D) have a prognostic advantage over HF patients with narrow QRS (therefore without indication for CRT) treated with an implantable cardioverter defibrillator (ICD) only. The aim of this study was to compare the long-term mortality of a group of HF patients with prolonged QRS receiving CRT-D with that of a similar group of patients with narrow QRS receiving ICD only. METHODS AND RESULTS: A total of 312 patients (mean age 66 ± 13 years; 84% male, mean left ventricular ejection fraction 25 ± 4%, mean New York Heart Association class 2.6 ± 0.5) were included in the analysis. Of these, 138 with a QRS complex duration ≥120 ms received a CRT-D. During follow-up, the time and cause of death were assessed. During a median follow-up of 46 months, CRT-D patients showed significantly lower overall mortality (P = 0.038). Compared with patients receiving ICD only, CRT-D patients showed lower HF mortality (P = 0.003). Coronary mortality, non-cardiac mortality, and sudden mortality were similar in both groups (all P > 0.05). A positive response to CRT was an independent predictor of reduced mortality on multivariate analysis (hazard ratio: 0.27; P = 0.047). CONCLUSION: In HF patients treated with ICD, the subgroup of patients with prolonged QRS who receive CRT-D displays better long-term survival than narrow QRS ICD recipients, owing to their reduced HF mortality.


Asunto(s)
Arritmias Cardíacas/terapia , Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Sistema de Conducción Cardíaco/fisiopatología , Insuficiencia Cardíaca/terapia , Potenciales de Acción , Anciano , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/fisiopatología , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/mortalidad , Causas de Muerte , Distribución de Chi-Cuadrado , Supervivencia sin Enfermedad , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/mortalidad , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Frecuencia Cardíaca , Humanos , Italia , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Análisis Multivariante , Modelos de Riesgos Proporcionales , Factores Protectores , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
19.
G Ital Cardiol (Rome) ; 24(7): 551-570, 2023 Jul.
Artículo en Italiano | MEDLINE | ID: mdl-37392121

RESUMEN

The number of cardiac implantable electronic device (CIED) implantations has increased over recent years as a result of population growth, increasing life expectancy, adoption of guidelines, and better access to healthcare. Device-related infection is, however, one of the most serious complications of CIED therapy associated with significant morbidity, mortality, and financial healthcare burden. Although many preventive strategies such as administration of intravenous antibiotic therapy before implantation are well recognized, uncertainties still exist about other regimens. Uncertainties have remained about the role of various preventive, diagnostic, and treatment measures such as skin antiseptics, pocket antibiotic solutions, anti-bacterial envelopes, prolonged antibiotics post-implantation, and others. The key aspect to successful treatment of definite CIED infections is complete removal of all parts of the system and transvenous hardware, including the device and all leads. Thus, transvenous lead extraction has been increasing. Expert consensus statements on how to prevent, diagnose, and treat CIED infections and on lead extraction have been published by the European Heart Rhythm Association in 2020 and 2018, respectively. The aim of this AIAC position paper is to describe the current knowledge on the risks for device-related infections and to assist healthcare professionals in their clinical decision making regarding its prevention, diagnosis, and management by providing the latest update of the most effective strategies.


Asunto(s)
Cardiopatías , Corazón , Humanos , Antibacterianos/uso terapéutico , Toma de Decisiones Clínicas , Electrónica
20.
Heart Rhythm ; 20(7): 992-997, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36966948

RESUMEN

BACKGROUND: The HeartLogic algorithm (Boston Scientific) has proved to be a sensitive and timely predictor of impending heart failure (HF) decompensation. OBJECTIVE: The purpose of this study was to determine whether remotely monitored data from this algorithm could be used to identify patients at high risk for mortality. METHODS: The algorithm combines implantable cardioverter-defibrillator (ICD)-measured accelerometer-based heart sounds, intrathoracic impedance, respiration rate, ratio of respiration rate to tidal volume, night heart rate, and patient activity into a single index. An alert is issued when the index crosses a programmable threshold. The feature was activated in 568 ICD patients from 26 centers. RESULTS: During median follow-up of 26 months [25th-75th percentile 16-37], 1200 alerts were recorded in 370 patients (65%). Overall, the time IN-alert state was 13% of the total observation period (151/1159 years) and 20% of the follow-up period of the 370 patients with alerts. During follow-up, 55 patients died (46 in the group with alerts). The rate of death was 0.25 per patient-year (95% confidence interval [CI] 0.17-0.34) IN-alert state and 0.02 per patient-year (95% CI 0.01-0.03) OUT of the alert state, with an incidence rate ratio of 13.72 (95% CI 7.62-25.60; P <.001). After multivariate correction for baseline confounders (age, ischemic cardiomyopathy, kidney disease, atrial fibrillation), the IN-alert state remained significantly associated with the occurrence of death (hazard ratio 9.18; 95% CI 5.27-15.99; P <.001). CONCLUSION: The HeartLogic algorithm provides an index that can be used to identify patients at higher risk for all-cause mortality. The index state identifies periods of significantly increased risk of death.


Asunto(s)
Fibrilación Atrial , Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Terapia de Resincronización Cardíaca/efectos adversos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/etiología , Fibrilación Atrial/terapia , Algoritmos
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda