Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
País como asunto
Tipo del documento
Publication year range
1.
Radiography (Lond) ; 29(1): 184-189, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36469993

RESUMEN

INTRODUCTION: The use of computed tomography (CT) in healthcare institutions has increased rapidly in recent years. The Singapore Health Services (SingHealth) cluster of healthcare institutions has taken the first step in establishing a local cluster-wide CT Diagnostic Reference Levels (DRL) in Singapore. CT dose data from each institution were collected through two primary dosimetry metrics: volume CT dose index (CTDIvol measured in mGy) and dose-length product (DLP measured in mGy.cm). METHODS: Data from 19 CT scanners in seven institutions under one of Singapore healthcare cluster were retrospectively collected and analysed. The five common adult CT examinations analysed were CT Brain (non-contrast enhanced), CT Chest (IV contrast enhanced), CT Kidney-Ureter-Bladder (CT KUB, non-contrast enhanced), CT Pulmonary Angiogram (CT PA, IV contrast enhanced) and CT Abdomen-Pelvis (CT AP, IV contrast enhanced, single phase). Median CTDIvol and DLP values for the five CT examinations from each institution were derived, with the cluster DRLs determined as the 75th percentile of the distribution of the institution median dose values. RESULTS: A total of 2413 dose data points were collected over a six-month period from June to November 2020. The cluster CT DRLs for the five CT examinations were determined to be 47 mGy and 820 mGy.cm for CT Brain, 5.4 mGy and 225 mGy.cm for CT Chest, 6.7 mGy and 248 mGy.cm for CT PA, 4.6 mGy and 190 mGy.cm for CT KUB and 6.9 mGy and 349 mGy.cm for CT AP. CONCLUSION: The establishment of the cluster CT DRLs provided individual institutions with a better understanding if their CT doses are unusually high or low, while emphasising that these DRLs are not meant as hard dose limits or constraints to follow strictly.


Asunto(s)
Niveles de Referencia para Diagnóstico , Tomografía Computarizada por Rayos X , Adulto , Humanos , Dosis de Radiación , Estudios Retrospectivos , Singapur , Tomografía Computarizada por Rayos X/métodos , Atención a la Salud
2.
Matrix Biol ; 28(1): 53-61, 2009 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-19041721

RESUMEN

The microstructure of keratan sulphate purified from the interglobular domain, the keratan sulphate-rich region and total aggrecan was compared using fluorophore-assisted-carbohydrate-electrophoresis. Keratan sulphate in the interglobular domain was substantially less sulphated than keratan sulphate elsewhere on aggrecan, based on the ratio of unsulphated: monosulphated disaccharides generated by endo-beta-galactosidase digestion, and the ratio of monosulphated: disulphated disaccharides generated by keratanase II digestion. The ratio of unsulphated: monosulphated: disulphated disaccharides was 1:4:5 for keratan sulphate from total aggrecan and the keratan sulphate-rich region, but only 1:0.9:0.8 for the interglobular domain. These results show that keratan sulphate in the interglobular domain of pig aggrecan has a microstructure that is distinct from keratan sulphate in the keratan sulphate-rich region.


Asunto(s)
Agrecanos/química , Sulfato de Queratano/química , Sulfato de Queratano/metabolismo , Porcinos , Agrecanos/aislamiento & purificación , Secuencia de Aminoácidos , Animales , Secuencia Conservada , Humanos , Datos de Secuencia Molecular , Fragmentos de Péptidos/aislamiento & purificación , Fragmentos de Péptidos/metabolismo , Estructura Terciaria de Proteína , Alineación de Secuencia
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda