Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
J Card Fail ; 2024 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-38851449

RESUMEN

BACKGROUND: Prediction of outcomes remains an unmet need in candidates for LVADs. The development of right-heart failure portends an excess in mortality rates, but imaging parameters of right ventricular systolic function have failed to demonstrate a prognostic role. By integrating pulmonary pressure, right ventriculoarterial coupling could fill this gap. METHODS: The ASSIST-ICD registry was used to test right ventriculoarterial coupling as a surrogate parameter at implantation for the prediction of all-cause mortality. RESULTS: The ratio of the tricuspid annular-plane systolic excursion over the estimated systolic pulmonary pressure (TAPSE/sPAP) was not associated with long-term survival in univariate analysis (P = 0.89), nor was the pulmonary artery pulsatility index (PAPi) (P = 0.13). Conversely, the ratio of the right atrial pressure over the pulmonary capillary wedge pressure (RAP/PCWP) was associated with all-cause mortality (P < 0.01). After taking tricuspid regurgitation severity, LVAD indication, LVAD model, age, blood urea nitrogen levels, and pulmonary vascular resistance into account, RAP/PCWP remained associated with survival (HR 1.35 [1.10 - 1.65]; P < 0.01). CONCLUSION: Among pre-implant RVAC surrogates, only RAP/PCWP was associated with long-term all-cause mortality in LVAD recipients. This association was independent of established risk factors.

2.
Crit Care ; 28(1): 54, 2024 02 20.
Artículo en Inglés | MEDLINE | ID: mdl-38374103

RESUMEN

BACKGROUND: Both critically ill patients with coronavirus disease 2019 (COVID-19) and patients receiving extracorporeal membrane oxygenation (ECMO) support exhibit a high incidence of healthcare-associated infections (HAI). However, data on incidence, microbiology, resistance patterns, and the impact of HAI on outcomes in patients receiving ECMO for severe COVID-19 remain limited. We aimed to report HAI incidence and microbiology in patients receiving ECMO for severe COVID-19 and to evaluate the impact of ECMO-associated infections (ECMO-AI) on in-hospital mortality. METHODS: For this study, we analyzed data from 701 patients included in the ECMOSARS registry which included COVID-19 patients supported by ECMO in France. RESULTS: Among 602 analyzed patients for whom HAI and hospital mortality data were available, 214 (36%) had ECMO-AI, resulting in an incidence rate of 27 ECMO-AI per 1000 ECMO days at risk. Of these, 154 patients had bloodstream infection (BSI) and 117 patients had ventilator-associated pneumonia (VAP). The responsible microorganisms were Enterobacteriaceae (34% for BSI and 48% for VAP), Enterococcus species (25% and 6%, respectively) and non-fermenting Gram-negative bacilli (13% and 20%, respectively). Fungal infections were also observed (10% for BSI and 3% for VAP), as were multidrug-resistant organisms (21% and 15%, respectively). Using a Cox multistate model, ECMO-AI were not found associated with hospital death (HR = 1.00 95% CI [0.79-1.26], p = 0.986). CONCLUSIONS: In a nationwide cohort of COVID-19 patients receiving ECMO support, we observed a high incidence of ECMO-AI. ECMO-AI were not found associated with hospital death. Trial registration number NCT04397588 (May 21, 2020).


Asunto(s)
COVID-19 , Infección Hospitalaria , Oxigenación por Membrana Extracorpórea , Neumonía Asociada al Ventilador , Sepsis , Humanos , COVID-19/epidemiología , COVID-19/terapia , COVID-19/complicaciones , Estudios de Cohortes , Oxigenación por Membrana Extracorpórea/efectos adversos , Oxigenación por Membrana Extracorpórea/métodos , Infección Hospitalaria/epidemiología , Neumonía Asociada al Ventilador/etiología , Sepsis/complicaciones , Atención a la Salud , Estudios Retrospectivos
3.
Crit Care Med ; 51(1): 36-46, 2023 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-36519982

RESUMEN

OBJECTIVES: Prone positioning and venovenous extracorporeal membrane oxygenation (ECMO) are both useful interventions in acute respiratory distress syndrome (ARDS). Combining the two therapies is feasible and safe, but the effectiveness is not known. Our objective was to evaluate the potential survival benefit of prone positioning in venovenous ECMO patients cannulated for COVID-19-related ARDS. DESIGN: Retrospective analysis of a multicenter cohort. PATIENTS: Patients on venovenous ECMO who tested positive for severe acute respiratory syndrome coronavirus 2 by reverse transcriptase polymerase chain reaction or with a diagnosis on chest CT were eligible. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: All patients on venovenous ECMO for respiratory failure in whom prone position status while on ECMO and in-hospital mortality were known were included. Of 647 patients in 41 centers, 517 were included. Median age was 55 (47-61), 78% were male and 95% were proned before cannulation. After cannulation, 364 patients (70%) were proned and 153 (30%) remained in the supine position for the whole ECMO run. There were 194 (53%) and 92 (60%) deaths in the prone and the supine groups, respectively. Prone position on ECMO was independently associated with lower in-hospital mortality (odds ratio = 0.49 [0.29-0.84]; p = 0.010). In 153 propensity score-matched pairs, mortality rate was 49.7% in the prone position group versus 60.1% in the supine position group (p = 0.085). Considering only patients alive at decannulation, propensity-matched proned patients had a significantly lower mortality rate (22.4% vs 37.8%; p = 0.029) than nonproned patients. CONCLUSIONS: Prone position may be beneficial in patients supported by venovenous ECMO for COVID-19-related ARDS but more data are needed to draw definitive conclusions.


Asunto(s)
COVID-19 , Oxigenación por Membrana Extracorpórea , Síndrome de Dificultad Respiratoria , Humanos , Masculino , Persona de Mediana Edad , Femenino , Posición Prona , Estudios Retrospectivos , COVID-19/terapia , Síndrome de Dificultad Respiratoria/terapia
4.
Anesthesiology ; 136(5): 732-748, 2022 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-35348610

RESUMEN

BACKGROUND: Despite expanding use, knowledge on extracorporeal membrane oxygenation support during the COVID-19 pandemic remains limited. The objective was to report characteristics, management, and outcomes of patients receiving extracorporeal membrane oxygenation with a diagnosis of COVID-19 in France and to identify pre-extracorporeal membrane oxygenation factors associated with in-hospital mortality. A hypothesis of similar mortality rates and risk factors for COVID-19 and non-COVID-19 patients on venovenous extracorporeal membrane oxygenation was made. METHODS: The Extracorporeal Membrane Oxygenation for Respiratory Failure and/or Heart failure related to Severe Acute Respiratory Syndrome-Coronavirus 2 (ECMOSARS) registry included COVID-19 patients supported by extracorporeal membrane oxygenation in France. This study analyzed patients included in this registry up to October 25, 2020, and supported by venovenous extracorporeal membrane oxygenation for respiratory failure with a minimum follow-up of 28 days after cannulation. The primary outcome was in-hospital mortality. Risk factors for in-hospital mortality were analyzed. RESULTS: Among 494 extracorporeal membrane oxygenation patients included in the registry, 429 were initially supported by venovenous extracorporeal membrane oxygenation and followed for at least 28 days. The median (interquartile range) age was 54 yr (46 to 60 yr), and 338 of 429 (79%) were men. Management before extracorporeal membrane oxygenation cannulation included prone positioning for 411 of 429 (96%), neuromuscular blockage for 419 of 427 (98%), and NO for 161 of 401 (40%). A total of 192 of 429 (45%) patients were cannulated by a mobile extracorporeal membrane oxygenation unit. In-hospital mortality was 219 of 429 (51%), with a median follow-up of 49 days (33 to 70 days). Among pre-extracorporeal membrane oxygenation modifiable exposure variables, neuromuscular blockage use (hazard ratio, 0.286; 95% CI, 0.101 to 0.81) and duration of ventilation (more than 7 days compared to less than 2 days; hazard ratio, 1.74; 95% CI, 1.07 to 2.83) were independently associated with in-hospital mortality. Both age (per 10-yr increase; hazard ratio, 1.27; 95% CI, 1.07 to 1.50) and total bilirubin at cannulation (6.0 mg/dl or more compared to less than 1.2 mg/dl; hazard ratio, 2.65; 95% CI, 1.09 to 6.5) were confounders significantly associated with in-hospital mortality. CONCLUSIONS: In-hospital mortality was higher than recently reported, but nearly half of the patients survived. A high proportion of patients were cannulated by a mobile extracorporeal membrane oxygenation unit. Several factors associated with mortality were identified. Venovenous extracorporeal membrane oxygenation support should be considered early within the first week of mechanical ventilation initiation.


Asunto(s)
COVID-19 , Oxigenación por Membrana Extracorpórea , Insuficiencia Respiratoria , COVID-19/terapia , Estudios de Cohortes , Oxigenación por Membrana Extracorpórea/efectos adversos , Humanos , Masculino , Pandemias , Insuficiencia Respiratoria/etiología , Insuficiencia Respiratoria/terapia , Estudios Retrospectivos
5.
Cardiovasc Drugs Ther ; 36(2): 285-294, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-33528720

RESUMEN

PURPOSE: Hybrid aortic arch repair in patients with chronic residual aortic dissection (RAD) is a less invasive alternative to conventional surgical treatment. The aim of this study was to describe the short-term and long-term results of hybrid treatment for RAD after type A repair. METHODS: In this retrospective single-center cohort study, all patients treated for chronic RAD with hybrid aortic arch repair were included. Indications for treatment were rapid aortic growth, aortic diameter > 55 mm, or aortic rupture. RESULTS: Between 2009 and 2020, we performed 29 hybrid treatments for chronic RAD. Twenty-four patients were treated for complete supra-aortic debranching in zones 0 and 5 with left subclavian artery debranching alone in zone 2. There was 1 perioperative death (3.4%): The patient was treated for an aortic rupture. There was no spinal cord ischemia and 1 minor stroke (3.4%). After a median follow-up of 25.4 months (range 3-97 months), the long-term mortality was 10.3% (3/29) with no late aortic-related deaths. Twenty-seven patients (93.1%) developed FL thrombosis of the descending thoracic aorta; the rate of aneurysmal progression on thoraco-abdominal aorta was 41.4% (12/29), and the rate of aortic reintervention was 34.5% (10/29). CONCLUSION: In a high-volume aortic center, hybrid repair of RAD is associated with good anatomical results and a low risk of perioperative morbidity and mortality, including that of patients treated in zone 0. A redo replacement of the ascending aortic segment is sometimes necessary to provide a safer proximal landing zone and reduce the risk of type 1 endoleak after TEVAR.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Rotura de la Aorta , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Rotura de la Aorta/diagnóstico por imagen , Rotura de la Aorta/etiología , Rotura de la Aorta/cirugía , Implantación de Prótesis Vascular/efectos adversos , Estudios de Cohortes , Procedimientos Endovasculares/efectos adversos , Humanos , Estudios Retrospectivos , Factores de Riesgo , Stents , Factores de Tiempo , Resultado del Tratamiento
6.
Circulation ; 141(4): 260-268, 2020 01 28.
Artículo en Inglés | MEDLINE | ID: mdl-31736332

RESUMEN

BACKGROUND: Two competing transcatheter aortic valve replacement (TAVR) technologies are currently available. Head-to-head comparisons of the relative performances of these 2 devices have been published. However, long-term clinical outcome evaluation remains limited by the number of patients analyzed, in particular, for recent-generation devices. METHODS: Based on the French administrative hospital-discharge database, the study collected information for all consecutive patients treated with a TAVR device commercialized in France between 2014 and 2018. Propensity score matching was used for the analysis of outcomes during follow-up. The objective of this study was to analyze the outcomes of TAVR according to Sapien 3 balloon-expandable (BE) versus Evolut R self-expanding TAVR technology at a nationwide level in France. RESULTS: A total of 31 113 patients treated with either Sapien 3 BE or Evolut R self-expanding TAVR were found in the database. After matching on baseline characteristics, 20 918 patients were analyzed (10 459 in each group with BE or self-expanding valves). During follow-up (mean [SD], 358 [384]; median [interquartile range], 232 [10-599] days), BE TAVR was associated with a lower yearly incidence of all-cause death (relative risk, 0.88; corrected P=0.005), cardiovascular death (relative risk, 0.82; corrected P=0.002), and rehospitalization for heart failure (relative risk, 0.84; corrected P<0.0001). BE TAVR was also associated with lower rates of pacemaker implantation after the procedure (relative risk, 0.72; corrected P<0.0001). CONCLUSIONS: On the basis of the largest cohort available, we observed that Sapien 3 BE valves were associated with lower rates of all-cause death, cardiovascular death, rehospitalization for heart failure, and pacemaker implantation after a TAVR procedure.


Asunto(s)
Estenosis de la Válvula Aórtica , Bases de Datos Factuales , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Supervivencia sin Enfermedad , Femenino , Estudios de Seguimiento , Francia , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/cirugía , Humanos , Estudios Longitudinales , Masculino , Readmisión del Paciente , Estudios Retrospectivos , Tasa de Supervivencia
7.
J Card Surg ; 36(6): 2004-2012, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33686755

RESUMEN

BACKGROUND: There are insufficient studies comparing rapid deployment aortic valve replacement (RDAVR) and trans-aortic valve replacement (TAVR) in intermediate-risk patients with severe aortic stenosis (AS). AIMS: We compared 2-year outcomes between RDAVR with INTUITY and TAVR with SAPIEN 3 in intermediate-risk patients with AS. METHODS: Inclusion criteria were patients with severe AS at a EuroSCORE II ≥ 4%, who received RDAVR or TAVR implantation and clinical evaluation by the Heart Team. Regression adjustment for the propensity score was used to compare RDAVR and TAVR. Primary outcome was the composite criterion of death, disabling stroke, or rehospitalization. SECONDARY OUTCOMES: major bleeding complications postoperation, paravalvular regurgitation ≥ 2, patient-prosthesis mismatch, and pacemaker implantation. RESULTS: A total of 152 patients were included from 2012 to 2018: 48 in the RDAVR group and 104 in the TAVR group. The mean age was 82.7 ± 6.0,51.3% patients were female, the mean EuroSCORE II was 6.03 ± 1.6%, mean baseline LVEF was 56 ± 13%, mean indexed effective orifice area was 0.41 ± 0.1 cm/m2 , and the mean gradient was 51.7 ± 14.7 mmHg. RDAVR patients were younger (79.5 ± 6 years vs. 82.6 ± 6 years; p = .01), and at higher risk (EuroSCORE II, 6.61 ± 1.8% vs. 5.63 ± 1.5%; p = .005), Twenty-two patients (45.99%) in the RDAVR group and 32 (66.67%) in the TAVR group met the composite criterion. Through the 1:1 propensity score matching analysis, there was a significant difference between the groups, favoring RDAVR (HR = 0.58 [95% CI: 0.34-1.00]; p = .04). No differences were observed in terms of patient-prosthesis mismatch (0.83 [0.35-1.94]; p = .67), major bleeding events (1.33 [0.47-3.93]; p = .59), paravalvular regurgitation ≥ 2 (0.33[0-6.28]; p = .46), or pacemaker implantation (0.84 [0.25-2.84]; p = .77) CONCLUSION: RDAVR was associated with better 2-year outcomes than TAVR in intermediate-risk patients with severe symptomatic AS.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Catéteres , Femenino , Humanos , Masculino , Puntaje de Propensión , Diseño de Prótesis , Factores de Riesgo , Resultado del Tratamiento
8.
Crit Care Med ; 48(10): e971-e975, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32618700

RESUMEN

OBJECTIVES: The main objective of the study was to determine the prevalence of venous thromboembolism events in patients infected with severe acute respiratory syndrome coronavirus 2 requiring venovenous extracorporeal membrane oxygenation. The secondary objective was to compare venous thromboembolism events and coagulation variables in patients requiring venovenous extracorporeal membrane oxygenation according to the pathogen. DESIGN: Retrospective observational analysis at a single center. SETTING: Tertiary referral university teaching hospital. PATIENTS: Patients with severe acute respiratory syndrome coronavirus 2-related severe acute respiratory distress syndrome requiring venovenous extracorporeal membrane oxygenation therapy with an injected CT scan performed after extracorporeal membrane oxygenation retrieval. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: We included 13 severe acute respiratory syndrome coronavirus 2 patients requiring venovenous extracorporeal membrane oxygenation. All of these patients experienced venous thromboembolism: 10 patients (76.9%) had isolated cannula-associated deep vein thrombosis, two patients (15.4%) had isolated pulmonary embolism, and one patient (7.7%) had both cannula-associated deep vein thrombosis and pulmonary embolism. Eleven patients (84.6%) had cannula-associated deep vein thrombosis. A jugular associated cannula-associated deep vein thrombosis was identified in seven patients (53.8%), a femoral associated cannula-associated deep vein thrombosis was identified in 10 patients (76.9%), and six patients (46.2%) had both femoral and jugular cannula-associated deep vein thrombosis. A pulmonary embolism was found in three patients (23.1%). No patient had central venous catheter-related deep vein thrombosis. One patient had thrombotic occlusion of the centrifugal pump, and one had oxygenator thrombosis requiring circuit replacement. Three patients (23.1%) had significant bleeding. Three patients (23.1%) had laboratory-confirmed heparin-induced thrombocytopenia, and all of them developed cannula-associated deep vein thrombosis. These three patients had femoral cannula-associated deep vein thrombosis, and two had an oxygenator or pump thrombosis. The mean activated partial thromboplastin time ratio was higher in the severe acute respiratory syndrome coronavirus 2 group than in the influenza group and the community-acquired pneumonia group (1.91 vs 1.48 vs 1.53; p = 0.001), which was also found in regard to the percentage of patients with an activated partial thromboplastin time ratio greater than 1.8 (47.8% vs 20% vs 20.9%; p = 0.003) and the mean prothrombin ratio (86.3 vs 61.6 vs 67.1; p = 0.003). There was no difference in baseline characteristics or venous thromboembolism events. CONCLUSIONS: We report a 100% occurrence of venous thromboembolism in critically ill patients supported by venovenous extracorporeal membrane oxygenation for severe acute respiratory syndrome coronavirus 2-related acute respiratory distress syndrome using CT scan imaging despite a high target and close monitoring of anticoagulation.


Asunto(s)
Anticoagulantes/administración & dosificación , Infecciones por Coronavirus/terapia , Oxigenación por Membrana Extracorpórea/efectos adversos , Neumonía Viral/terapia , Síndrome Respiratorio Agudo Grave/diagnóstico por imagen , Síndrome Respiratorio Agudo Grave/terapia , Tromboembolia Venosa/tratamiento farmacológico , COVID-19 , Estudios de Cohortes , Infecciones por Coronavirus/diagnóstico , Cuidados Críticos/métodos , Enfermedad Crítica/mortalidad , Enfermedad Crítica/terapia , Oxigenación por Membrana Extracorpórea/métodos , Femenino , Francia , Mortalidad Hospitalaria/tendencias , Hospitales Universitarios , Humanos , Unidades de Cuidados Intensivos , Masculino , Pandemias , Neumonía Viral/diagnóstico , Estudios Retrospectivos , Medición de Riesgo , Síndrome Respiratorio Agudo Grave/mortalidad , Tasa de Supervivencia , Centros de Atención Terciaria , Tomografía Computarizada por Rayos X/métodos , Resultado del Tratamiento , Tromboembolia Venosa/etiología , Tromboembolia Venosa/mortalidad
9.
Diagnostics (Basel) ; 14(13)2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-39001296

RESUMEN

BACKGROUND: Cardiac injury caused by a sharp object is a medical and surgical therapeutic challenge. Mortality risk factors have been identified but there are major discrepancies in the literature. The aim of this study was to analyse the management of victims of penetrating cardiac injuries before and after admission to hospital and the anatomical characteristics of these injuries in order to facilitate diagnosis of the most critical patients. METHODS: To carry out this study, we conducted a retrospective analytical study with epidemiological data on victims of penetrating cardiac injuries. We included two types of patients, with those who underwent autopsy in our institution after death from sharp injury to the heart or great vessels and those who survived with treatment in the emergency department or intensive care unit between January 2015 and February 2022. RESULTS: We included 30 autopsied patients and 12 survivors aged between 18 and 73 years. Higher mortality was associated with prehospital or in-hospital cardiorespiratory arrest (OR = 4, CI [1.71-9.35]), preoperative mechanical ventilation (OR = 10, CI [1.53-65.41]), preoperative catecholamines (OR = 7, CI [1.12-6.29]), preoperative and perioperative adrenaline (OR = 13, CI [1.98-85.46] and [1.98-85.46]), penetrating cardiac injury (OR = 14, CI [2.10-93.22]), multiple cardiac injuries (OR = 1.5, CI [1.05-2.22]) and an Organ Injury Scaling of the American Association for the Surgery of Trauma (AAST-OIS) score of 5 (OR = 2.9, CI [1.04-8.54]; p = 0.0329) with an AUC-ROC curve value of 0.708 (CI [0.543-0.841]). CONCLUSIONS: This study identified risk mortality factors in penetrating cardiac injury patients. These findings can help improve the diagnosis and management of these patients. The AAST-OIS score may be a good tool to diagnose critical patients.

10.
Ann Thorac Surg ; 115(6): 1446-1454, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-35952857

RESUMEN

BACKGROUND: We evaluated the incidence, prognosis, and predictive factors of new onset of persistent left bundle branch block (NOP-LBBB) after rapid-deployment aortic valve replacement (RD-AVR). METHODS: This was an observational, retrospective, single-center study of 274 consecutive patients with no baseline ventricular conduction disorder and no previous permanent pacemaker implantation (PPI) who underwent RD-AVR with an INTUITY valve (n = 55) or INTUITY Elite Valve (n = 219) (Edwards Lifesciences). Transthoracic echocardiography and 12-lead electrocardiography was performed preoperatively, at discharge, and at 1-month and 1-year intervals. The incidence, prognosis, and predictive factors of NOP-LBBB were evaluated. RESULTS: NOP-LBBB occurred in 58 patients (21.2%) after discharge. In multivariate analysis, age (P < .01), INTUITY valve diameter ≥23 mm (P = .02), and INTUITY Elite implantation (P = .01) were independent predictors of NOP-LBBB. By 1:1 propensity matching analysis between the NOP-LBBB group and the control group, there were no significant differences in 1-year overall mortality (P = .23), hospitalization for congestive heart failure (P = .99), or PPI (P = .99). NOP-LBBB exposed patients to a high rate of dysrhythmic events (12.1% vs 1.4%, P < .01) and was associated with a significant decrease in left ventricular ejection fraction (0.62 ± 0.095 vs 0.652 ± 0.0783, P = .02) without an impact on New York Heart Association functional status (1.25 ± 0.32 and 1.52 ± 0.70, P = .32). PPI was performed in 17 patients (6.2%) before discharge, including 14 NOP-LBBB patients. CONCLUSIONS: NOP-LBBB after RD-AVR is prevalent in patients with no prior conduction disorders. INTUITY Elite is associated with a significantly higher rate of NOP-LBBB. The persistence of NOP-LBBB predisposed patients to the occurrence of high-grade conduction disorders and might have led to PPI but did not increase death or hospitalization for congestive heart failure.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia Cardíaca , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/cirugía , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/epidemiología , Bloqueo de Rama/etiología , Volumen Sistólico , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento , Incidencia , Estenosis de la Válvula Aórtica/cirugía , Función Ventricular Izquierda , Prótesis Valvulares Cardíacas/efectos adversos , Electrocardiografía , Insuficiencia Cardíaca/cirugía , Marcapaso Artificial/efectos adversos
11.
Front Cardiovasc Med ; 10: 1076708, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36910534

RESUMEN

Background: Degenerative mitral regurgitation (DMR) due to mitral valve prolapse (MVP) is a common valve disease associated with significant morbidity and mortality. Timing for surgery is debated for asymptomatic patients without Class I indication, prompting the search for novel parameters of early left ventricular (LV) systolic dysfunction. Aims: To evaluate the prognostic impact of preoperative forward flow indices on the occurrence of post-operative LV systolic dysfunction. Methods: We retrospectively included all consecutive patients with severe DMR due to MVP who underwent mitral valve repair between 2014 and 2019. LVOTTVI, forward stroke volume index, and forward LVEF were assessed as potential risk factors for LVEF <50% at 6 months post-operatively. Results: A total of 198 patients were included: 154 patients (78%) were asymptomatic, and 46 patients (23%) had hypertension. The mean preoperative LVEF was 69 ± 9%. 35 patients (18%) had LVEF ≤ 60%, and 61 patients (31%) had LVESD ≥40 mm. The mean post-operative LVEF was 59 ± 9%, and 21 patients (11%) had post-operative LVEF<50%. Based on multivariable analysis, LVOTTVI was the strongest independent predictor of post-operative LV dysfunction after adjustment for age, sex, symptoms, LVEF, LV end systolic diameter, atrial fibrillation and left atrial volume index (0.75 [0.62-0.91], p < 0.01). The best sensitivity (81%) and specificity (63%) was obtained with LVOTTVI ≤15 cm based on ROC curve analysis. Conclusion: LVOTTVI represents an independent marker of myocardial performance impairment in the presence of severe DMR. LVOTTVI could be an earlier marker than traditional echo parameters and aids in the optimization of the timing of surgery.

12.
Front Cardiovasc Med ; 10: 1196447, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37600038

RESUMEN

Introduction: The use of an aortic bioprosthesis is on the rise in younger patients with severe aortic stenosis despite the risk of accelerated structural valve degeneration (SVD). In the search for an optimal valve substitute that would not be prone to SVD, the INSPIRIS bioprosthesis represents a promising solution to lowering the risk of SVD. Here, we report the 1-year outcomes of the INSPIRIS RESILIA aortic bioprosthesis in a population of young patients who underwent aortic valve replacement. Methods: In this prospective single-center study, we included all consecutive patients receiving INSPIRIS RESILIA bioprosthesis between June 2017 and July 2021. Patients with isolated severe aortic regurgitation were excluded. Clinical assessment and transthoracic echocardiography were performed preoperatively and at 1 year post-operatively. The primary outcome was overall mortality at one year. Results: A total of 487 patients were included. The mean age was 58.2 ± 11.5 years, 75.2% were men. Most of the interventions were elective, with a mean EuroSCORE II of 4.8 ± 7.9. The valve annulus size in most cases was either 23 mm or 25 mm. Overall mortality at 1-year was 4.1%. At 1-year, 7 patients (1.4%) had a stroke, 4 patients (0.8%) had a myocardial infarction, and 20 patients (4.1%) were hospitalized for congestive heart failure. The Kaplan-Meier estimated survival rates and survival without major adverse cardiac events at 1-year were 96.4% and 96.7%, respectively. At 1-year follow-up, 10 patients (2.1%) had endocarditis and 1 patient (0.2%) had partial prosthetic thrombosis. Pacemaker implantation at 1-year post-operative was necessary in 27 patients (5.5%). Severe patient prosthesis mismatch and severe intra valvular regurgitation were 1.2% and 0.6%, respectively. The Kaplan-Meier estimated survival rates at 1-year of no infective endocarditis preoperative and infective endocarditis preoperative were 97.9 ± 0.7% and 89.5 ± 3.3%, respectively (P < 0.001). Excluding endocarditis-related complication, no structural valve deterioration and no valve failure requiring redo surgery were reported. Conclusion: This is the largest single-center descriptive study of the 1-year outcomes after INSPIRIS RESILIA bioprosthesis implantation. The EDWARDS INSPIRIS RESILIA bioprosthesis provides encouraging clinical outcomes with an excellent 1- year survival rates and good hemodynamic performance. Long-term studies are mandatory to assess valve durability.

13.
J Clin Med ; 12(13)2023 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-37445413

RESUMEN

Objectives: Aortic dissection in patients with Marfan and related syndromes (HTAD) is a serious pathology whose treatment by thoracic endovascular repair (TEVAR) is still under debate. The aim of this study was to assess the results of the TEVAR for aortic dissection in patients with HTAD as compared to a young population without HTAD. Methods: The study received the proper ethical oversight. We performed an observational exposed (confirmed HTAD) vs. non-exposed (<65 years old) study of TEVAR-treated patients. The preoperative, 1 year, and last available CT scans were analyzed. The thoracic and abdominal aortic diameters, aortic length, and volumes were measured. The entry tears and false lumen (FL) status were assessed. The demographic, clinical, and anatomic data were collected during the follow-up. Results: Between 2011 and 2021, 17 patients were included in the HTAD group and 22 in the non-HTAD group. At 1 year, the whole aortic volume increased by +21.2% in the HTAD group and by +0.2% the non-HTAD groups, p = 0.005. An increase in the whole aortic volume > 10% was observed in ten cases (58.8%) in the HTAD group and in five cases (22.7%) in the non-HTAD group (p = 0.022). FL thrombosis was achieved in nine cases (52.9%) in the HTAD group vs. twenty (90.9%) cases in the non-HTAD group (p < 0.01). The risk factors for unfavorable anatomical evolution were male gender and the STABILISE technique. With a linear model, we observed a significantly different aortic volume evolution between the two groups (p < 0.01) with the STABILISE technique; this statistical difference was not found in the TEVAR subgroup. In the HTAD patients, there was a significant difference in the total aortic volume evolution progression between the patients treated with the STABILISE technique and the patients treated with TEVAR (+160.1 ± 52.3% vs. +47 ± 22.5%, p < 0.01 and +189.5 ± 92.5% vs. +58.6 ± 34.8%, p < 0.01 at 1 year and at the end of follow-up, respectively). Conclusions: TEVAR in the HTAD patients seemed to be associated with poorer anatomical outcomes at 1 year. This result was strongly related to the STABILISE technique which should be considered with care in these specific patients.

14.
J Clin Med ; 12(6)2023 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-36983286

RESUMEN

Coronary artery disease (CAD) screening is usually performed before transcatheter aortic valve implantation (TAVI) by invasive coronary angiography (ICA). Computed coronary tomography angiography (CCTA) has shown good diagnostic performance for CAD screening in patients with a low probability of CAD and is systematically performed before TAVI. CCTA could be an efficient alternative to ICA for CAD screening before TAVI. We sought to investigate the diagnostic performance of CCTA in a population of unselected patients without known CAD who were candidates for TAVI. All consecutive patients referred to our center for TAVI without known CAD were enrolled. All patients underwent CCTA and ICA, which were considered the gold standard. A statistical analysis of the diagnostic performance per patient and per artery was performed. 307 consecutive patients were enrolled. CCTA was non-analyzable in 25 patients (8.9%). In the per-patient analysis, CCTA had a sensitivity of 89.6%, a specificity of 90.2%, a positive predictive value of 65.15%, and a negative predictive value of 97.7%. Only five patients were classified as false negatives on the CCTA. Despite some limitations of the study, CCTA seems reliable for CAD screening in patients without known CAD who are candidates for TAVI. By using CCTA, ICA could be avoided in patients with a CAD-RADS score ≤ 2, which represents 74.8% of patients.

15.
J Clin Med ; 12(6)2023 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-36983363

RESUMEN

Background After a type A aortic dissection repair, a patent false lumen in the descending aorta is the most common situation encountered, and is a well-known risk factor for aortic growth, reinterventions and mortality. The aim of this study was to analyze the long-term results of residual aortic dissection (RAD) at a high-volume aortic center with prospective follow-up. Methods In this prospective single-center study, all patients operated for type A aortic dissection between January 2017 and December 2022 were included. Patients without postoperative computed tomography scans or during follow-up at our center, and patients without RAD were excluded. The primary endpoint was all-cause mortality during follow-up for patients with RAD. The secondary endpoints were perioperative mortality, rate of distal aneurysmal evolution, location of distal aneurysmal evolution, rate of distal reinterventions, outcomes of distal reinterventions, and aortic-related death during follow-up. Results In total, 200 survivors of RAD comprised the study group. After a mean follow-up of 27.2 months (1-66), eight patients (4.0%) died and 107 (53.5%) had an aneurysmal progression. The rate of distal reintervention was 19.5% (39/200), for malperfusion syndrome in seven cases (3.5%) and aneurysmal evolution in 32 cases (16.0%). Most reinterventions occurred during the first 2 years (82.1%). Twenty-seven patients were treated for an aneurysmal evolution of RAD including aortic arch with hybrid repair in 21 cases and branched aortic arch endoprosthesis in six cases. In the hybrid repair group, there was no death, and the rate of morbidity was 28.6% (6/21) (one minor stroke, one pulmonary complication, one recurrent paralysis with complete recovery and three major bleeding events). In the branched endograft group, there was no death, no stroke, and no paraplegia. There was one case (16.7%) of carotid dissection. Complete aortic remodeling or complete FL thrombosis on the thoracic aorta was found in 18 cases (85.7%) and in five cases (83.3%) in the hybrid and branched endograft groups, respectively. Conclusions: Despite a critical course in most cases of RAD, with a high rate of aneurysmal evolution and reintervention, the long-term mortality rate remains low with a close follow-up and a multidisciplinary management in an expert center.

16.
Eur J Cardiothorac Surg ; 64(3)2023 09 07.
Artículo en Inglés | MEDLINE | ID: mdl-37280062

RESUMEN

OBJECTIVES: The clinical profile and outcomes of patients with Coronavirus Disease 2019 (COVID-19) who require veno-arterial extracorporeal membrane oxygenation (VA-ECMO) or veno-arterial-venous extracorporeal membrane oxygenation (VAV-ECMO) are poorly understood. We aimed to describe the characteristics and outcomes of these patients and to identify predictors of both favourable and unfavourable outcomes. METHODS: ECMOSARS is a multicentre, prospective, nationwide French registry enrolling patients who require veno-venous extracorporeal membrane oxygenation (ECMO)/VA-ECMO in the context of COVID-19 infection (652 patients at 41 centres). We focused on 47 patients supported with VA- or VAV-ECMO for refractory cardiogenic shock. RESULTS: The median age was 49. Fourteen percent of patients had a prior diagnosis of heart failure. The most common aetiologies of cardiogenic shock were acute pulmonary embolism (30%), myocarditis (28%) and acute coronary syndrome (4%). Extracorporeal cardiopulmonary resuscitation (E-CPR) occurred in 38%. In-hospital survival was 28% in the whole cohort, and 43% when E-CPR patients were excluded. ECMO cannulation was associated with significant improvements in pH and FiO2 on day 1, but non-survivors showed significantly more severe acidosis and higher FiO2 than survivors at this point (P = 0.030 and P = 0.006). Other factors associated with death were greater age (P = 0.02), higher body mass index (P = 0.03), E-CPR (P = 0.001), non-myocarditis aetiology (P = 0.02), higher serum lactates (P = 0.004), epinephrine (but not noradrenaline) use before initiation of ECMO (P = 0.003), haemorrhagic complications (P = 0.001), greater transfusion requirements (P = 0.001) and more severe Survival after Veno-Arterial ECMO (SAVE) and Sonographic Assessment of Intravascular Fluid Estimate (SAFE) scores (P = 0.01 and P = 0.03). CONCLUSIONS: We report the largest focused analysis of VA- and VAV-ECMO recipients in COVID-19. Although relatively rare, the need for temporary mechanical circulatory support in these patients is associated with poor prognosis. However, VA-ECMO remains a viable solution to rescue carefully selected patients. We identified factors associated with poor prognosis and suggest that E-CPR is not a reasonable indication for VA-ECMO in this population.


Asunto(s)
COVID-19 , Oxigenación por Membrana Extracorpórea , Humanos , Persona de Mediana Edad , Choque Cardiogénico/etiología , Choque Cardiogénico/terapia , Estudios Prospectivos , COVID-19/complicaciones , COVID-19/terapia , Sistema de Registros , Oxígeno , Estudios Retrospectivos
17.
Case Rep Crit Care ; 2022: 1070830, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35909992

RESUMEN

Venovenous extracorporeal membrane oxygenation (VV-ECMO) is an adjuvant treatment for severe acute respiratory distress syndrome (ARDS) with refractory hypoxemia. Contraindications to therapeutic anticoagulation must be ruled out prior to ECMO implementation. We report the case of a 17-year-old male admitted in intensive care unit (ICU) for penetrating chest trauma due to multiple gunshot wounds. The body computed tomography (body CT scan) documented right pulmonary contusions and a homolateral hemothorax. His condition rapidly deteriorated with refractory hypoxemia due to lung contusion requiring invasive mechanical ventilation (IMV) and polytransfused hemorrhagic shock. During his stay in ICU, venovenous ECMO (VV-ECMO) was implemented twice, firstly for trauma-induced ARDS and secondly after thoracic surgery. This case emphasizes the successful use of VV-ECMO in posttraumatic ARDS without increasing the risk of bleeding.

18.
J Clin Med ; 11(7)2022 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-35407567

RESUMEN

Prosthesis−patient mismatch (PPM) is associated with worse outcomes following surgical aortic valve replacement (SAVR). PPM has been identified in a significant proportion of TAVR, particularly in patients with small aortic annuli. Our objective was to evaluate the hemodynamic performances of balloon-expandable (BE) (Sapiens 3TM) versus two different self-expandable (SE) (Evolut ProTM, Accurate NeoTM) TAVR devices in patients with small aortic annulus defined by a computed tomography aortic annulus area (AAA) between 330 and 440 mm2. We enrolled 131 consecutive patients corresponding to 76 Sapiens 3 23 mm (58.0%), 26 Evolut Pro (19.9%) and 29 Accurate Neo (22.1%). Mean age was 82.5 ± 7.06 years, 22.9% of patients were male and mean Euroscore was 4.0%. Mean AAA was 374 ± 27 mm2 for Sapiens 3, 383 ± 29 mm2 for Corevalve Evolut Pro and 389 ± 25 mm2 for Accurate Neo. BE devices were associated with significantly higher rates of PPM (39.5%) as compared to SE devices (15.4% for Corevalve Evolut Pro and 6.9% for Accurate Neo) (p < 0.0001). Paravalvular leaks ≥ 2/4 were more often observed in SE devices (15.4% for Corevalve Evolut Pro and 17.2% for Accurate Neo) than in BE devices (2.6%) (p = 0.007). In conclusion, SE TAVR devices did achieve better hemodynamic results despite higher rates of paravalvular leaks. Therefore, SE TAVI devices could be considered as first choice in small aortic anatomy.

19.
Intensive Care Med ; 48(8): 1039-1052, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35829723

RESUMEN

PURPOSE: To describe bleeding and thrombotic events and their risk factors in patients receiving extracorporeal membrane oxygenation (ECMO) for severe coronavirus disease 2019 (COVID-19) and to evaluate their impact on in-hospital mortality. METHODS: The ECMOSARS registry included COVID-19 patients supported by ECMO in France. We analyzed all patients included up to March 31, 2022 without missing data regarding bleeding and thrombotic events. The association of bleeding and thrombotic events with in-hospital mortality and pre-ECMO variables was assessed using multivariable logistic regression models. RESULTS: Among 620 patients supported by ECMO, 29% had only bleeding events, 16% only thrombotic events and 20% both bleeding and thrombosis. Cannulation site (18% of patients), ear nose and throat (12%), pulmonary bleeding (9%) and intracranial hemorrhage (8%) were the most frequent bleeding types. Device-related thrombosis and pulmonary embolism/thrombosis accounted for most of thrombotic events. In-hospital mortality was 55.7%. Bleeding events were associated with in-hospital mortality (adjusted odds ratio (adjOR) = 2.91[1.94-4.4]) but not thrombotic events (adjOR = 1.02[0.68-1.53]). Intracranial hemorrhage was strongly associated with in-hospital mortality (adjOR = 13.5[4.4-41.5]). Ventilation duration before ECMO ≥ 7 days and length of ECMO support were associated with bleeding. Thrombosis-associated factors were fibrinogen ≥ 6 g/L and length of ECMO support. CONCLUSIONS: In a nationwide cohort of COVID-19 patients supported by ECMO, bleeding incidence was high and associated with mortality. Intracranial hemorrhage incidence was higher than reported for non-COVID patients and carried the highest risk of death. Thrombotic events were less frequent and not associated with mortality. Length of ECMO support was associated with a higher risk of both bleeding and thrombosis, supporting the development of strategies to minimize ECMO duration.


Asunto(s)
COVID-19 , Oxigenación por Membrana Extracorpórea , Trombosis , Anticoagulantes/efectos adversos , COVID-19/complicaciones , COVID-19/terapia , Estudios de Cohortes , Oxigenación por Membrana Extracorpórea/efectos adversos , Hemorragia/inducido químicamente , Hemorragia/etiología , Humanos , Hemorragias Intracraneales/epidemiología , Hemorragias Intracraneales/etiología , Estudios Retrospectivos , Trombosis/epidemiología , Trombosis/etiología
20.
J Cardiovasc Dev Dis ; 9(10)2022 Oct 12.
Artículo en Inglés | MEDLINE | ID: mdl-36286301

RESUMEN

Background: The aim of this study was to evaluate the aortic diameter and volume during the first year after a type A repair to predict the long-term prognosis of a residual aortic dissection (RAD). Methods: All patients treated in our center for an acute type A dissection with a RAD and follow-up > 3 years were included. We defined two groups: group 1 with dissection-related events (defined as an aneurysmal evolution, distal reintervention, or aortic-related death) and group 2 without dissection-related events. The aortic diameters and volume analysis were evaluated on three postoperative CT scans: pre-discharge (T1), 3−6 months (T2) and 1 year (T3). Results: Between 2009 and 2016, 54 patients were included. Following a mean follow-up of 75.4 months (SD 31.5), the rate of dissection-related events was 62.9% (34/54). The total aortic diameters of the descending thoracic aorta were greater in group 1 at T1, T2 and T3, with greater diameters in the FL (p < 0.01). The aortic diameter evolution at 3 months was not predictive of long-term dissection-related events. The total thoracic aortic volume was significantly greater in group 1 at T1 (p < 0.01), T2 (p < 0.01), and T3 (p < 0.01). At 3 months, the increase in the FL volume was significantly greater in group 1 (p < 0.01) and was predictive for long-term dissection-related events. Conclusion: This study shows that an initial CT scan volume analysis coupled with another at 3 months is predictive for the long-term evolution in a RAD. Based on this finding, more aggressive treatment could be given at an earlier stage.

SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda