Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Sensors (Basel) ; 24(18)2024 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-39338881

RESUMEN

Although the physical properties of a structure, such as stiffness, can be determined using some statical tests, the identification of damping parameters requires a dynamic test. In general, both theoretical prediction and experimental identification of damping are quite difficult. There are many different techniques available for damping identification, and each method gives a different damping parameter. The dynamic indentation method, rheometry, atomic force microscopy, and resonant vibration tests are commonly used to identify the damping of materials, including soft materials. While the viscous damping ratio, loss factor, complex modulus, and viscosity are quite common to describe the damping of materials, there are also other parameters, such as the specific damping capacity, loss angle, half-power bandwidth, and logarithmic decrement, to describe the damping of various materials. Often, one of these parameters is measured, and the measured parameter needs to be converted into another damping parameter for comparison purposes. In this review, the theoretical derivations of different parameters for the description and quantification of damping and their relationships are presented. The expressions for both high damping and low damping are included and evaluated. This study is considered as the first comprehensive review article presenting the theoretical derivations of a large number of damping parameters and the relationships among many damping parameters, with a quantitative evaluation of accurate and approximate formulas. This paper could be a primary resource for damping research and teaching.

2.
J Acoust Soc Am ; 153(5): 2649, 2023 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-37129678

RESUMEN

In this article, it is shown experimentally that a planar laser-generated ultrasound source with a hard reflective backing will generate higher acoustic pressures than a comparable source with an acoustically matched backing when the stress confinement condition is not met. Furthermore, while the source with an acoustically matched backing will have a broader bandwidth when the laser pulse is short enough to ensure stress confinement, the bandwidths of both source types will converge as the laser pulse duration increases beyond stress confinement. The explanation of the results is supported by numerical simulations.

3.
Artículo en Inglés | MEDLINE | ID: mdl-36034073

RESUMEN

Background: India is the epicenter of diabetes mellitus (DM). The relationship between COVID and DM in age/gender-matched non-diabetics has not been studied yet. The role of DM in predicting the disease severity and outcome in COVID patients might provide new insight for effective management. Methods: We conducted a prospective comparative study at a COVID care center from 25th April-31st May 2021. Among 357 severe-COVID patients screened, all consecutive diabetes (n-113) and age/gender-matched non-diabetes (n-113) patients were recruited. All diabetics and non-diabetics at admission were subjected to high resolution computed tomography (HRCT) chest and inflammatory markers (C-reactive protein (CRP), D-dimer, ferritin, interleukin-6 (IL-6), lactate dehydrogenase (LDH), Neutrophil-Lymphocyte Ratio (NLR)) before starting anti- COVID therapy. Statistical analysis was done using JMP 15·0 ver·3·0·0. Results: The prevalence of DM among the screened population (n-357) was 38·37%. The mean age of the study population was 61y with male preponderance (57%). There was no statistical difference in the HRCT-score or inflammatory markers in the two groups except for higher NLR (p-0·0283) in diabetics. Diabetics had significantly inferior overall survival (OS) (p-0·0251) with a 15d-OS of diabetics vs. non-diabetics being 58·87%, 72·67%, and 30d-OS of diabetics vs. non-diabetics being 46·76%, 64·61%, respectively. The duration of the hospital stay was not statistically different in the two groups (p-0·2). Conclusion: The mortality is significantly higher in severe-COVID patients with DM when compared to age/gender-matched non-diabetics. There was no significant difference in most inflammatory markers/CT at admission between the two groups.

4.
J Acoust Soc Am ; 149(3): 2040, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33765774

RESUMEN

Optical generation of ultrasound using nanosecond duration laser pulses has generated great interest both in industrial and biomedical applications. The availability of portable laser devices using semiconductor technology and optical fibres, as well as numerous source material types based on nanocomposites, has proliferated the applications of laser ultrasound. The nanocomposites can be deposited on the tip of optical fibres as well as planar hard and soft backing materials using various fabrication techniques, making devices suitable for a variety of applications. The ability to choose the acoustic material properties and the laser pulse duration gives considerable control over the ultrasound output. Here, an analytical time-domain solution is derived for the acoustic pressure waveform generated by a planar optical ultrasound source consisting of an optically absorbing layer on a backing. It is shown that by varying the optical attenuation coefficient, the thickness of the absorbing layer, the acoustic properties of the materials, and the laser pulse duration, a wide variety of pulse shapes and trains can be generated. It is shown that a source with a reflecting backing can generate pulses with higher amplitude than a source with an acoustically-matched backing in the same circumstances when stress-confinement has not been satisfied.

5.
J Acoust Soc Am ; 144(2): 584, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30180662

RESUMEN

The characterization of ultrasound fields generated by diagnostic and therapeutic equipment is an essential requirement for performance validation and to demonstrate compliance against established safety limits. This requires hydrophones calibrated to a traceable standard. Currently, the upper calibration frequency range available to the user community is limited to 60 MHz. However, high frequencies are increasingly being used for both imaging and therapy necessitating calibration frequencies up to 100 MHz. The precise calibration of hydrophones requires a source of high amplitude, broadband, quasi-planar, and stable ultrasound fields. There are challenges to using conventional piezoelectric sources, and laser generated ultrasound sources offer a promising solution. In this study, various nanocomposites consisting of a bulk polymer matrix and multi-walled carbon nanotubes were fabricated and tested using pulsed laser of a few nanoseconds for their suitability as a source for high frequency calibration of hydrophones. The pressure amplitude and bandwidths were measured using a broadband hydrophone from 27 different nanocomposite sources. The effect of nonlinear propagation of high amplitude laser generated ultrasound on bandwidth and the effect of bandlimited sensitivity response on the deconvolved pressure waveform were numerically investigated. The stability of the nanocomposite sources under sustained laser pulse excitation was also examined.

6.
Artículo en Inglés | MEDLINE | ID: mdl-36112557

RESUMEN

Hydrophones are pivotal measurement devices ensuring medical ultrasound acoustic exposures comply with the relevant national and international safety criteria. These devices have enabled the spatial and temporal distribution of key safety parameters to be determined in an objective and standardized way. Generally based on piezoelectric principles of operation, to convert generated voltage waveforms to acoustic pressure, they require calibration in terms of receive sensitivity, expressed in units of [Formula: see text]Pa-1. Reliable hydrophone calibration with associated uncertainties plays a key role in underpinning a measurement framework that ensures exposure measurements are comparable and traceable to internationally agreed units, irrespective of where they are carried out globally. For well over three decades, the U.K. National Physical Laboratory (NPL) has provided calibrations to the user community covering the frequency range 0.1-60 MHz, traceable to a primary realization of the acoustic pascal through optical interferometry. Typical uncertainties for sensitivity are 6%-22% (for a coverage factor k = 2), degrading with frequency. The article specifically focuses on the dissemination of the acoustic pascal through NPL's calibration services that are based on a comparison with secondary standard hydrophones previously calibrated using the NPL primary standard. The work demonstrates the stability of the employed dissemination protocols by presenting representative calibration histories on a selection of commercially available hydrophones. Results reaffirm the guidance provided within international standards for regular calibration of a hydrophone in order to underpin measurement confidence. The process by which internationally agreed realizations of the acoustic pascal are compared and validated through key comparisons (KCs) is also described.

7.
Artículo en Inglés | MEDLINE | ID: mdl-36094977

RESUMEN

Hydrophones are generally calibrated in acoustic fields with temporally localized (short pulse) or long duration (tone burst) signals. Free-field conditions are achieved by time gating any reflections from the hydrophone body, mounting structures, and surrounding water tank boundaries arriving at the active sensing element. Consequently, the sensitivity response of the hydrophone is a result of direct waves incident on its active element, free from any contaminating effects of reflections. However, when using tone bursts below 400 kHz to calibrate hydrophones, it may not be possible to isolate the direct wave from reflection artifacts. This means that the sensitivity responses derived at these frequencies using short pulse and tone burst signals might not be comparable as they can be characteristic of the acoustic field interaction with either/both the hydrophone active element alone or the hydrophone active element and body. Therefore, there is a need to consider an appropriate calibration method for a given hydrophone type, depending on whether the eventual application employs short pulse or tone burst acoustic fields. This article presents the findings from a short study comprising four needle-type hydrophones of active element diameters in the range of 1-4 mm. These hydrophones were calibrated from 30 kHz to 1.6 MHz using established calibration methodologies within the underwater acoustics (UWA) and ultrasound (US) areas employed at the National Physical Laboratory (NPL), Teddington, U.K. In UWA tone, burst acoustic fields are used, while in US, it is short pulses. The 2- and 4-mm-diameter needle hydrophones showed the largest variation at the overlapping frequencies, in which the maximum disagreement of UWA calibration was 30% relative to US calibration. For the 4-mm hydrophone, UWA calibration exhibited resonant sensitivity structure between 100 and 450 kHz, but which was absent in US calibration. This observed behavior was further investigated theoretically by using a validated acoustic wave solver to confirm the resonant sensitivity structure seen in the case of UWA calibration. The work contained within illustrates the need to ensure that the method of calibration is carefully considered in the context of the duration of the acoustic signals for which the hydrophone is intended.

8.
J Vis Exp ; (196)2023 06 16.
Artículo en Inglés | MEDLINE | ID: mdl-37395576

RESUMEN

Establishing tissue-mimicking biophotonic phantom materials that provide long-term stability are imperative to enable the comparison of biomedical imaging devices across vendors and institutions, support the development of internationally recognized standards, and assist the clinical translation of novel technologies. Here, a manufacturing process is presented that results in a stable, low-cost, tissue-mimicking copolymer-in-oil material for use in photoacoustic, optical, and ultrasound standardization efforts. The base material consists of mineral oil and a copolymer with defined Chemical Abstract Service (CAS) numbers. The protocol presented here yields a representative material with a speed of sound c(f) = 1,481 ± 0.4 m·s-1 at 5 MHz (corresponds to the speed of sound of water at 20 °C), acoustic attenuation α(f) = 6.1 ± 0.06 dB·cm-1 at 5 MHz, optical absorption µa(λ) = 0.05 ± 0.005 mm-1 at 800 nm, and optical scattering µs'(λ) = 1 ± 0.1 mm-1 at 800 nm. The material allows independent tuning of the acoustic and optical properties by respectively varying the polymer concentration or light scattering (titanium dioxide) and absorbing agents (oil-soluble dye). The fabrication of different phantom designs is displayed and the homogeneity of the resulting test objects is confirmed using photoacoustic imaging. Due to its facile, repeatable fabrication process and durability, as well as its biologically relevant properties, the material recipe has high promise in multimodal acoustic-optical standardization initiatives.


Asunto(s)
Diagnóstico por Imagen , Aceite Mineral , Fantasmas de Imagen , Ultrasonografía/métodos , Acústica , Polímeros/química
9.
Artículo en Inglés | MEDLINE | ID: mdl-37018591

RESUMEN

Hyperthermia is the process of raising tissue temperatures in the range 40 - 45 °C for a prolonged time (up to hours). Unlike in ablation therapy, raising the temperature to such levels does not cause necrosis of the tissue but has been postulated to sensitize the tissue for radiotherapy. The ability to maintain a certain temperature in a target region is key to a hyperthermia delivery system. The aim of this work was to design and characterize a heat delivery system for ultrasound hyperthermia able to generate a uniform power deposition pattern in the target region with a closed-loop control which would maintain the defined temperature over a defined period. The hyperthermia delivery system presented herein is a flexible design with the ability to strictly control the induced temperature rise with a feedback loop. The system can be reproduced elsewhere with relative ease and is adaptable for various tumor sizes/locations and for other temperature elevation applications, such as ablation therapy. The system was fully characterized and tested on a newly-designed custom-built phantom with controlled acoustic and thermal properties and containing embedded thermocouples. Additionally, a layer of thermochromic material was fixed above the thermocouples and the recorded temperature increase was compared to the RGB (red, green, and blue) color-change in the material. The transducer characterization allowed for input voltage to output power curves to be generated, thus allowing for comparison of power deposition to temperature increase in the phantom. Additionally, the transducer characterization generated a field map of the symmetric field. The system was capable of increasing the temperature of the target area by 6 °C above body temperature and maintain the temperature to within ±0.5 °C over a defined period. The increase in temperature correlated with the RGB image analysis of the thermochromic material. The results of this work have the potential to contribute towards increasing confidence in the delivery of hyperthermia treatment to superficial tumors. The developed system could potentially be used for phantom or small animal proof-of-principle studies. The developed phantom test device may be used for testing other hyperthermia systems.

10.
IEEE Trans Med Imaging ; 40(12): 3593-3603, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34152979

RESUMEN

Photoacoustic imaging (PAI) standardisation demands a stable, highly reproducible physical phantom to enable routine quality control and robust performance evaluation. To address this need, we have optimised a low-cost copolymer-in-oil tissue-mimickingmaterial formulation. The base material consists of mineral oil, copolymer and stabiliser with defined Chemical Abstract Service numbers. Speed of sound c(f) and acoustic attenuation coefficient α (f) were characterised over 2-10 MHz; optical absorption µa ( λ ) and reduced scattering µs '( λ ) coefficients over 450-900 nm. Acoustic properties were optimised by modifying base component ratios and optical properties were adjusted using additives. The temporal, thermomechanical and photo-stabilitywere studied, alongwith intra-laboratory fabrication and field-testing. c(f) could be tuned up to (1516±0.6) [Formula: see text] and α (f) to (17.4±0.3)dB · cm -1 at 5 MHz. The base material exhibited negligible µa ( λ ) and µs '( λ ), which could be independently tuned by addition of Nigrosin or TiO2 respectively. These properties were stable over almost a year and were minimally affected by recasting. The material showed high intra-laboratory reproducibility (coefficient of variation <4% for c ( f ), α ( f ), optical transmittance and reflectance), and good photo- and mechanical-stability in the relevant working range (20-40°C). The optimised copolymer-in-oil material represents an excellent candidate for widespread application in PAI phantoms, with properties suitable for broader use in biophotonics and ultrasound imaging standardisation efforts.


Asunto(s)
Técnicas Fotoacústicas , Acústica , Diagnóstico por Imagen , Fantasmas de Imagen , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda