Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Semin Neurol ; 43(3): 439-453, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37562454

RESUMEN

Intracranial venous pathologies are a historically underrecognized group of disorders that can have a devastating impact on patients. Despite advancements in peripheral venous disorders and arterial neurointerventions, intracranial venous pathologies have received comparatively little attention. Understanding the anatomy, physiology, clinical relevance, and treatment options of intracranial venous pathologies is fundamental to evolving therapies and research priorities. This article provides an overview of major intracranial venous pathologies, the respective pathophysiologies, and treatment options.

2.
Chem Rev ; 119(8): 5461-5533, 2019 04 24.
Artículo en Inglés | MEDLINE | ID: mdl-30689360

RESUMEN

Bio-integrated wearable systems can measure a broad range of biophysical, biochemical, and environmental signals to provide critical insights into overall health status and to quantify human performance. Recent advances in material science, chemical analysis techniques, device designs, and assembly methods form the foundations for a uniquely differentiated type of wearable technology, characterized by noninvasive, intimate integration with the soft, curved, time-dynamic surfaces of the body. This review summarizes the latest advances in this emerging field of "bio-integrated" technologies in a comprehensive manner that connects fundamental developments in chemistry, material science, and engineering with sensing technologies that have the potential for widespread deployment and societal benefit in human health care. An introduction to the chemistries and materials for the active components of these systems contextualizes essential design considerations for sensors and associated platforms that appear in following sections. The subsequent content highlights the most advanced biosensors, classified according to their ability to capture biophysical, biochemical, and environmental information. Additional sections feature schemes for electrically powering these sensors and strategies for achieving fully integrated, wireless systems. The review concludes with an overview of key remaining challenges and a summary of opportunities where advances in materials chemistry will be critically important for continued progress.


Asunto(s)
Técnicas Biosensibles/instrumentación , Dispositivos Electrónicos Vestibles , Técnicas Biosensibles/métodos , Humanos , Ciencia de los Materiales/métodos
3.
Sens Actuators B Chem ; 3322021 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-33542590

RESUMEN

Sweat is a promising, yet relatively unexplored biofluid containing biochemical information that offers broad insights into the underlying dynamic metabolic activity of the human body. The rich composition of electrolytes, metabolites, hormones, proteins, nucleic acids, micronutrients, and exogenous agents found in sweat dynamically vary in response to the state of health, stress, and diet. Emerging classes of skin-interfaced wearable sensors offer powerful capabilities for the real-time, continuous analysis of sweat produced by the eccrine glands in a manner suitable for use in athletics, consumer wellness, military, and healthcare industries. This perspective examines the rapid and continuous progress of wearable sweat sensors through the most advanced embodiments that address the fundamental challenges currently restricting widespread deployment. It concludes with a discussion of efforts to expand the overall utility of wearable sweat sensors and opportunities for commercialization, in which advances in biochemical sensor technologies will be critically important.

4.
Small ; 14(47): e1803192, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30369049

RESUMEN

Precise, quantitative measurements of the thermal properties of human skin can yield insights into thermoregulatory function, hydration, blood perfusion, wound healing, and other parameters of clinical interest. The need for wired power supply systems and data communication hardware limits, however, practical applicability of existing devices designed for measurements of this type. Here, a set of advanced materials, mechanics designs, integration schemes, and wireless circuits is reported as the basis for wireless, battery-free sensors that softly interface to the skin to enable precise measurements of its temperature and thermal transport properties. Calibration processes connect these parameters to the hydration state of the skin, the dynamics of near-surface flow through blood vessels and implanted catheters, and to recovery processes following trauma. Systematic engineering studies yield quantitative metrics in precision and reliability in real-world conditions. Evaluations on five human subjects demonstrate the capabilities in measurements of skin hydration and injury, including examples of continuous wear and monitoring over a period of 1 week, without disrupting natural daily activities.


Asunto(s)
Electrónica/métodos , Piel/metabolismo , Tecnología Inalámbrica , Humanos
5.
Small ; 14(12): e1703334, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29394467

RESUMEN

This paper introduces super absorbent polymer valves and colorimetric sensing reagents as enabling components of soft, skin-mounted microfluidic devices designed to capture, store, and chemically analyze sweat released from eccrine glands. The valving technology enables robust means for guiding the flow of sweat from an inlet location into a collection of isolated reservoirs, in a well-defined sequence. Analysis in these reservoirs involves a color responsive indicator of chloride concentration with a formulation tailored to offer stable operation with sensitivity optimized for the relevant physiological range. Evaluations on human subjects with comparisons against ex situ analysis illustrate the practical utility of these advances.


Asunto(s)
Colorimetría/métodos , Microfluídica/métodos , Polímeros/química , Sudor/química , Humanos , Dispositivos Laboratorio en un Chip , Piel/metabolismo
6.
Langmuir ; 31(12): 3577-86, 2015 Mar 31.
Artículo en Inglés | MEDLINE | ID: mdl-25730093

RESUMEN

Plasmonic nanoparticles are used in a wide variety of applications over a broad array of fields including medicine, energy, and environmental chemistry. The continued successful development of this material class requires the accurate characterization of nanoparticle stability for a variety of solution-based conditions. Although many characterization methods exists, there is an absence of a unified, quantitative means for assessing the colloidal stability of plasmonic nanoparticles. We present the particle instability parameter (PIP) as a robust, quantitative, and generalizable characterization technique based on UV-vis absorbance spectroscopy to characterize colloidal instability. We validate PIP performance with both traditional and alternative characterization methods by measuring gold nanorod instability in response to different salt (NaCl) concentrations. We further measure gold nanorod stability as a function of solution pH, salt, and buffer (type and concentration), nanoparticle concentration, and concentration of free surfactant. Finally, these results are contextualized within the literature on gold nanorod stability to establish a standardized methodology for colloidal instability assessment.


Asunto(s)
Nanopartículas del Metal/química , Tampones (Química) , Cetrimonio , Compuestos de Cetrimonio/química , Coloides , Estabilidad de Medicamentos , Concentración de Iones de Hidrógeno , Cloruro de Sodio/química , Espectrofotometría Ultravioleta , Tensoactivos/química
7.
ACS Sens ; 8(10): 3606-3622, 2023 10 27.
Artículo en Inglés | MEDLINE | ID: mdl-37747817

RESUMEN

Recent advances in skin-interfaced wearable sweat sensors enable the noninvasive, real-time monitoring of biochemical signals associated with health and wellness. These wearable platforms leverage microfluidic channels, biochemical sensors, and flexible electronics to enable the continuous analysis of sweat-based biomarkers such as electrolytes, metabolites, and hormones. As this field continues to mature, the potential of low-cost, continuous personalized health monitoring enabled by such wearable sensors holds significant promise for addressing some of the formidable obstacles to delivering comprehensive medical care in under-resourced settings. This Perspective highlights the transformative potential of wearable sweat sensing for providing equitable access to cutting-edge healthcare diagnostics, especially in remote or geographically isolated areas. It examines the current understanding of sweat composition as well as recent innovations in microfluidic device architectures and sensing strategies by showcasing emerging applications and opportunities for innovation. It concludes with a discussion on expanding the utility of wearable sweat sensors for clinically relevant health applications and opportunities for enabling equitable access to innovation to address existing health disparities.


Asunto(s)
Sudor , Dispositivos Electrónicos Vestibles , Sudor/química , Salud Global , Medicina de Precisión , Piel/química
8.
J Neurointerv Surg ; 16(1): 4-7, 2023 Dec 19.
Artículo en Inglés | MEDLINE | ID: mdl-37438101

RESUMEN

Generative artificial intelligence (AI) holds great promise in neurointerventional surgery by providing clinicians with powerful tools for improving surgical precision, accuracy of diagnoses, and treatment planning. However, potential perils include biases or inaccuracies in the data used to train the algorithms, over-reliance on generative AI without human oversight, patient privacy concerns, and ethical implications of using AI in medical decision-making. Careful regulation and oversight are needed to ensure that the promises of generative AI in neurointerventional surgery are realized while minimizing its potential perils.[ChatGPT authored summary using the prompt "In one paragraph summarize the promises and perils of generative AI in neurointerventional surgery".].


Asunto(s)
Algoritmos , Inteligencia Artificial , Humanos , Toma de Decisiones Clínicas
9.
Sci Adv ; 9(18): eadg4272, 2023 05 03.
Artículo en Inglés | MEDLINE | ID: mdl-37134158

RESUMEN

Skin-interfaced wearable systems with integrated microfluidic structures and sensing capabilities offer powerful platforms for monitoring the signals arising from natural physiological processes. This paper introduces a set of strategies, processing approaches, and microfluidic designs that harness recent advances in additive manufacturing [three-dimensional (3D) printing] to establish a unique class of epidermal microfluidic ("epifluidic") devices. A 3D printed epifluidic platform, called a "sweatainer," demonstrates the potential of a true 3D design space for microfluidics through the fabrication of fluidic components with previously inaccessible complex architectures. These concepts support integration of colorimetric assays to facilitate in situ biomarker analysis operating in a mode analogous to traditional epifluidic systems. The sweatainer system enables a new mode of sweat collection, termed multidraw, which facilitates the collection of multiple, independent sweat samples for either on-body or external analysis. Field studies of the sweatainer system demonstrate the practical potential of these concepts.


Asunto(s)
Microfluídica , Sudor , Sudor/química , Microfluídica/métodos , Dispositivos Laboratorio en un Chip , Piel/química , Epidermis
10.
Int J Sports Phys Ther ; 17(5): 816-822, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35949376

RESUMEN

Background: Recent evidence has demonstrated that athletes are at greater risk for a lower extremity injury following a return-to-sport (RTS) after sport-related concussion (SRC). The reason for this is not completely clear, but it has been hypothesized that persistent deficits in neurocognitive factors may be a contributing factor. Hypothesis/Purpose: This study assessed simple reaction time, processing speed, attention, and concentration in a group of athletes, post-concussion upon clearance for RTS for potential deficits that may result in slower reaction time, processing speed, attention, and concentration. The researchers hypothesized that the concussion group would demonstrate worse scores on both assessments compared to a sex-, age-, and sport-matched cohort. Study Design: Case-controlled study. Methods: Twelve participants who had suffered a SRC and eight healthy individuals who were matched to the concussed group by age, sex, and sport were evaluated. Those with a concussion had been cleared for RTS by a licensed healthcare provider. Each participant underwent neurocognitive tests that included a simple reaction time test (SRT) and the King-Devick Test (K-D). Independent t-tests were performed to compare the groups with significance set a priori at p<0.05. Results: There was a significant difference (p =0.024) between groups for SRT with the concussed group demonstrating a better SRT than the control group. There were no significant differences (p =0.939) between the groups for the K-D. Conclusion: With no significant differences between groups in the K-D assessment and, surprisingly, the concussed group having a better SRT compared to the healthy group, our hypothesis was not supported. Clinical Relevance: These specific measures, compounded with extensive post-concussion time lapse until RTS clearance, may have limited capacity in revealing potential persistent deficits in relevant neurocognitive characteristics. Level of Evidence: Level of Evidence 3.

11.
MRS Adv ; 6(25): 636-643, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34532078

RESUMEN

Acoustic forces are an attractive pathway to achieve directed assembly for multi-phase materials via additive processes. Programmatic integration of microstructure and structural features during deposition offers opportunities for optimizing printed component performance. We detail recent efforts to integrate acoustic focusing with a direct-ink-write mode of printing to modulate material transport properties (e.g. conductivity). Acoustic field-assisted printing, operating under a multi-node focusing condition, supports deposition of materials with multiple focused lines in a single-pass printed line. Here, we report the demonstration of acoustic focusing in concert with diffusive self-assembly to rapidly assembly and print multiscale, mm-length colloidal solids on a timescale of seconds to minutes. These efforts support the promising capabilities of acoustic field-assisted deposition-based printing to achieve spatial control of printed microstructures with deterministic, long-range ordering across multiple length scales.

12.
ACS Sens ; 6(8): 2787-2801, 2021 08 27.
Artículo en Inglés | MEDLINE | ID: mdl-34351759

RESUMEN

Skin-interfaced wearable systems with integrated colorimetric assays, microfluidic channels, and electrochemical sensors offer powerful capabilities for noninvasive, real-time sweat analysis. This Perspective details recent progress in the development and translation of novel wearable sensors for personalized assessment of sweat dynamics and biomarkers, with precise sampling and real-time analysis. Sensor accuracy, system ruggedness, and large-scale deployment in remote environments represent key opportunity areas, enabling broad deployment in the context of field studies, clinical trials, and recent commercialization. On-body measurements in these contexts show good agreement compared to conventional laboratory-based sweat analysis approaches. These device demonstrations highlight the utility of biochemical sensing platforms for personalized assessment of performance, wellness, and health across a broad range of applications.


Asunto(s)
Sudor , Dispositivos Electrónicos Vestibles , Microfluídica , Piel
13.
Sci Transl Med ; 13(587)2021 03 31.
Artículo en Inglés | MEDLINE | ID: mdl-33790027

RESUMEN

The concentration of chloride in sweat remains the most robust biomarker for confirmatory diagnosis of cystic fibrosis (CF), a common life-shortening genetic disorder. Early diagnosis via quantitative assessment of sweat chloride allows prompt initiation of care and is critically important to extend life expectancy and improve quality of life. The collection and analysis of sweat using conventional wrist-strapped devices and iontophoresis can be cumbersome, particularly for infants with fragile skin, who often have insufficient sweat production. Here, we introduce a soft, epidermal microfluidic device ("sweat sticker") designed for the simple and rapid collection and analysis of sweat. Intimate, conformal coupling with the skin supports nearly perfect efficiency in sweat collection without leakage. Real-time image analysis of chloride reagents allows for quantitative assessment of chloride concentrations using a smartphone camera, without requiring extraction of sweat or external analysis. Clinical validation studies involving patients with CF and healthy subjects, across a spectrum of age groups, support clinical equivalence compared to existing device platforms in terms of accuracy and demonstrate meaningful reductions in rates of leakage. The wearable microfluidic technologies and smartphone-based analytics reported here establish the foundation for diagnosis of CF outside of clinical settings.


Asunto(s)
Fibrosis Quística , Sudor , Cloruros , Fibrosis Quística/diagnóstico , Fibrosis Quística/terapia , Humanos , Lactante , Calidad de Vida , Teléfono Inteligente
14.
Microsyst Nanoeng ; 6: 69, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32879734

RESUMEN

The intricate microarchitecture of tissues - the "tissue microenvironment" - is a strong determinant of tissue function. Microfluidics offers an invaluable tool to precisely stimulate, manipulate, and analyze the tissue microenvironment in live tissues and engineer mass transport around and into small tissue volumes. Such control is critical in clinical studies, especially where tissue samples are scarce, in analytical sensors, where testing smaller amounts of analytes results in faster, more portable sensors, and in biological experiments, where accurate control of the cellular microenvironment is needed. Microfluidics also provides inexpensive multiplexing strategies to address the pressing need to test large quantities of drugs and reagents on a single biopsy specimen, increasing testing accuracy, relevance, and speed while reducing overall diagnostic cost. Here, we review the use of microfluidics to study the physiology and pathophysiology of intact live tissues at sub-millimeter scales. We categorize uses as either in vitro studies - where a piece of an organism must be excised and introduced into the microfluidic device - or in vivo studies - where whole organisms are small enough to be introduced into microchannels or where a microfluidic device is interfaced with a live tissue surface (e.g. the skin or inside an internal organ or tumor) that forms part of an animal larger than the device. These microfluidic systems promise to deliver functional measurements obtained directly on intact tissue - such as the response of tissue to drugs or the analysis of tissue secretions - that cannot be obtained otherwise.

15.
Lab Chip ; 20(23): 4391-4403, 2020 11 24.
Artículo en Inglés | MEDLINE | ID: mdl-33089837

RESUMEN

Important insights into human health can be obtained through the non-invasive collection and detailed analysis of sweat, a biofluid that contains a wide range of essential biomarkers. Skin-interfaced microfluidic platforms, characterized by soft materials and thin geometries, offer a collection of capabilities for in situ capture, storage, and analysis of sweat and its constituents. In ambulatory uses cases, the ability to provide real-time feedback on sweat loss, rate and content, without visual inspection of the device, can be important. This paper introduces a low-profile skin-interfaced system that couples disposable microfluidic sampling devices with reusable 'stick-on' electrodes and wireless readout electronics that remain isolated from the sweat. An ultra-thin capping layer on the microfluidic platform permits high-sensitivity, contactless capacitive measurements of both sweat loss and sweat conductivity. This architecture avoids the potential for corrosion of the sensing components and eliminates the need for cleaning/sterilizing the electronics, thereby resulting in a cost-effective platform that is simple to use. Optimized electrode designs follow from a combination of extensive benchtop testing, analytical calculations and FEA simulations for two sensing configurations: (1) sweat rate and loss, and (2) sweat conductivity, which contains information about electrolyte content. Both configurations couple to a flexible, wireless electronics platform that digitizes and transmits information to Bluetooth-enabled devices. On-body field testing during physical exercise validates the performance of the system in scenarios of practical relevance to human health and performance.


Asunto(s)
Técnicas Biosensibles , Sudor , Electrónica , Humanos , Dispositivos Laboratorio en un Chip , Microfluídica , Piel
16.
Science ; 364(6447)2019 06 28.
Artículo en Inglés | MEDLINE | ID: mdl-31249029

RESUMEN

At the intersection of the outwardly disparate fields of nanoparticle science and three-dimensional printing lies the promise of revolutionary new "nanocomposite" materials. Emergent phenomena deriving from the nanoscale constituents pave the way for a new class of transformative materials with encoded functionality amplified by new couplings between electrical, optical, transport, and mechanical properties. We provide an overview of key scientific advances that empower the development of such materials: nanoparticle synthesis and assembly, multiscale assembly and patterning, and mechanical characterization to assess stability. The focus is on recent illustrations of approaches that bridge these fields, facilitate the design of ordered nanocomposites, and offer clear pathways to device integration. We conclude by highlighting the remaining scientific challenges, including the critical need for assembly-compatible particle-fluid systems that ultimately yield mechanically robust materials. The role of domain boundaries and/or defects emerges as an important open question to address, with recent advances in fabrication setting the stage for future work in this area.

17.
Sci Adv ; 5(1): eaau6356, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30746456

RESUMEN

Noninvasive, in situ biochemical monitoring of physiological status, via the use of sweat, could enable new forms of health care diagnostics and personalized hydration strategies. Recent advances in sweat collection and sensing technologies offer powerful capabilities, but they are not effective for use in extreme situations such as aquatic or arid environments, because of unique challenges in eliminating interference/contamination from surrounding water, maintaining robust adhesion in the presence of viscous drag forces and/or vigorous motion, and preventing evaporation of collected sweat. This paper introduces materials and designs for waterproof, epidermal, microfluidic and electronic systems that adhere to the skin to enable capture, storage, and analysis of sweat, even while fully underwater. Field trials demonstrate the ability of these devices to collect quantitative in situ measurements of local sweat chloride concentration, local sweat loss (and sweat rate), and skin temperature during vigorous physical activity in controlled, indoor conditions and in open-ocean swimming.


Asunto(s)
Técnicas Biosensibles/instrumentación , Epidermis/metabolismo , Dispositivos Laboratorio en un Chip , Microfluídica/instrumentación , Agua de Mar , Sudor/química , Termografía/instrumentación , Dispositivos Electrónicos Vestibles , Biomarcadores/análisis , Cloruros/análisis , Diseño de Equipo , Humanos , Piel/metabolismo , Natación/fisiología , Temperatura
18.
ACS Sens ; 4(2): 379-388, 2019 02 22.
Artículo en Inglés | MEDLINE | ID: mdl-30707572

RESUMEN

Real-time measurements of the total loss of sweat, the rate of sweating, the temperature of sweat, and the concentrations of electrolytes and metabolites in sweat can provide important insights into human physiology. Conventional methods use manual collection processes (e.g., absorbent pads) to determine sweat loss and lab-based instrumentation to analyze its chemical composition. Although such schemes can yield accurate data, they cannot be used outside of laboratories or clinics. Recently reported wearable electrochemical devices for sweat sensing bypass these limitations, but they typically involve on-board electronics, electrodes, and/or batteries for measurement, signal processing, and wireless transmission, without direct means for measuring sweat loss or capturing and storing small volumes of sweat. Alternative approaches exploit soft, skin-integrated microfluidic systems for collection and colorimetric chemical techniques for analysis. Here, we present the most advanced platforms of this type, in which optimized chemistries, microfluidic designs, and device layouts enable accurate assessments not only of total loss of sweat and sweat rate but also of quantitatively accurate values of the pH and temperature of sweat, and of the concentrations of chloride, glucose, and lactate across physiologically relevant ranges. Color calibration markings integrated into a graphics overlayer allow precise readout by digital image analysis, applicable in various lighting conditions. Field studies conducted on healthy volunteers demonstrate the full capabilities in measuring sweat loss/rate and analyzing multiple sweat biomarkers and temperature, with performance that quantitatively matches that of conventional lab-based measurement systems.


Asunto(s)
Colorimetría/instrumentación , Dispositivos Laboratorio en un Chip , Piel , Sudor/química , Temperatura , Biomarcadores/análisis , Humanos , Límite de Detección , Fenómenos Mecánicos
19.
Adv Mater ; 31(32): e1902109, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31206791

RESUMEN

Comprehensive analysis of sweat chemistry provides noninvasive health monitoring capabilities that complement established biophysical measurements such as heart rate, blood oxygenation, and body temperature. Recent developments in skin-integrated soft microfluidic systems address many challenges associated with standard technologies in sweat collection and analysis. However, recording of time-dependent variations in sweat composition requires bulky electronic systems and power sources, thereby constraining form factor, cost, and modes of use. Here, presented are unconventional design concepts, materials, and device operation principles that address this challenge. Flexible galvanic cells embedded within skin-interfaced microfluidics with passive valves serve as sweat-activated "stopwatches" that record temporal information associated with collection of discrete microliter volumes of sweat. The result allows for precise measurements of dynamic sweat composition fluctuations using in situ or ex situ analytical techniques. Integrated electronics based on near-field communication (NFC) protocols or docking stations equipped with standard electronic measurement tools provide means for extracting digital timing results from the stopwatches. Human subject studies of time-stamped sweat samples by in situ colorimetric methods and ex situ techniques based on inductively coupled plasma mass spectroscopy (ICP-MS) and chlorodimetry illustrate the ability to quantitatively capture time-dynamic sweat chemistry in scenarios compatible with field use.


Asunto(s)
Diseño de Equipo/instrumentación , Dispositivos Laboratorio en un Chip , Piel/química , Sudor/química , Técnicas Biosensibles/instrumentación , Colorimetría , Prueba de Esfuerzo , Humanos , Teléfono Inteligente , Factores de Tiempo , Dispositivos Electrónicos Vestibles
20.
Sci Adv ; 5(1): eaav3294, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30746477

RESUMEN

Wearable sweat sensors rely either on electronics for electrochemical detection or on colorimetry for visual readout. Non-ideal form factors represent disadvantages of the former, while semiquantitative operation and narrow scope of measurable biomarkers characterize the latter. Here, we introduce a battery-free, wireless electronic sensing platform inspired by biofuel cells that integrates chronometric microfluidic platforms with embedded colorimetric assays. The resulting sensors combine advantages of electronic and microfluidic functionality in a platform that is significantly lighter, cheaper, and smaller than alternatives. A demonstration device simultaneously monitors sweat rate/loss, pH, lactate, glucose, and chloride. Systematic studies of the electronics, microfluidics, and integration schemes establish the key design considerations and performance attributes. Two-day human trials that compare concentrations of glucose and lactate in sweat and blood suggest a potential basis for noninvasive, semi-quantitative tracking of physiological status.


Asunto(s)
Técnicas Biosensibles/instrumentación , Colorimetría/métodos , Dispositivos Laboratorio en un Chip , Microfluídica/métodos , Piel/metabolismo , Sudor/química , Dispositivos Electrónicos Vestibles , Fuentes de Energía Bioeléctrica , Cloruros/análisis , Glucosa/análisis , Voluntarios Sanos , Humanos , Concentración de Iones de Hidrógeno , Ácido Láctico/análisis , Masculino
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda