1.
Med Phys ; 37(1): 189-96, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20175481

RESUMEN

Gafchromic XR-QA films were developed for patient dosimetry in diagnostic radiology. A possible application of these films is the measurement of doses in computed tomography. In this study a method to evaluate the CTDI using Gafchromic XR-QA film and a flatbed scanner was developed and tested. Film samples were cut to dimensions of 6 x 170 mm2 in order to have an integration area similar to that of a pencil ionization chamber, with the possibility of changing the integration length. Prior to exposing these films to a computed tomography beam, the angular dependence of the film dose response was investigated by exposing film strips to a static x-ray beam at different angles in the range 0 degrees-180 degrees. A difference of 49% was found between the response with the axis beam parallel to the film surface (90 degrees) and with the axis beam perpendicular (0 degrees and 180 degrees). Integrating over a 360 degrees exposure like the one in computed tomography, a difference of less than 2% was estimated, which is comparable with the measurement error obtainable with XR-QA film. A calibration with a CT beam in the scout mode was performed and film strips were then exposed to single axial scans and to helical scans both in air and in phantoms. Two different types of flatbed scanners were used to read the film samples, a Microtek ScanMaker 9800XL scanner and an Epson Expression 10000 XL scanner, and the accuracy of the results were compared. For beam collimations above 10 mm differences between CTDI measured by film and CTDI measured by ionization chamber below 9% were found for the Epson scanner, with an average estimated error at 1 sigma level of 5%. For the Microtek scanner and for the same film samples, differences below 11% with an average error at 1 sigma level of 8% were founded. The 1 sigma uncertainty of the measured CTDI was provided by the method for each measurement, and it was shown that about the 95% of the differences between the CTDI measurements with radiochromic films and with the ionization chamber were below the estimated 2 sigma uncertainty, for both scanners. After an accurate calibration procedure and the consideration of the uncertainty associated with the measurement, Gafchromic XR-QA films can be used to evaluate the CTDI.


Asunto(s)
Dosimetría por Película/instrumentación , Tomografía Computarizada por Rayos X/instrumentación , Pantallas Intensificadoras de Rayos X , Diseño Asistido por Computadora , Diseño de Equipo , Análisis de Falla de Equipo , Dosis de Radiación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
2.
Phys Med ; 60: 91-99, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31000092

RESUMEN

PURPOSE: This study investigated the benefits of implementing a cluster analysis technique to extract relevant information from a computed tomography (CT) dose registry archive. METHODS: A CT patient dose database consisting of about 12,000 examinations and 29,000 single scans collected from three CT systems was interrogated. The database was divided into six subsets according to the equipment and the reference phantoms in the definition of the dose indicators. Hierarchical (single, average, and complete linkage, Ward) and not hierarchical (K-means) clustering methods were implemented using R software. The suitable number of clusters for each CT system was determined by analysing the dendrogram, the within clusters sum of squares, and the cluster content. Summary statistics were produced for each cluster, and the outliers of the dose indicator distribution were investigated. RESULTS: Ward clustering identified the most common combinations of scanning parameters for each group. The optimal number of clusters for each CT equipment system ranged from 5 to 15. The main diagnostic applications were then extracted from each cluster. Outlier analysis of the dose indicator distribution of each cluster revealed potential improper settings that resulted in increased patient dose. CONCLUSIONS: Clustering methods applied to CT patient dose archives provide a quick and effective overview of the main combinations of currently used exposure parameters and the consequences for dose indicator distributions, also when protocol labels and/or study descriptions are not homogeneous.


Asunto(s)
Análisis por Conglomerados , Dosis de Radiación , Tomografía Computarizada por Rayos X , Aprendizaje Automático no Supervisado , Minería de Datos/métodos , Bases de Datos Factuales , Humanos , Fantasmas de Imagen , Sistema de Registros , Programas Informáticos
3.
Phys Med Biol ; 51(6): 1577-93, 2006 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-16510964

RESUMEN

Quality controls for testing the performance of computed radiography (CR) systems have been recommended by manufacturers and medical physicists' organizations. The purpose of this work was to develop a set of image processing tools for quantitative assessment of computed radiography quality control parameters. Automatic image analysis consisted in detecting phantom details, defining regions of interest and acquiring measurements. The tested performance characteristics included dark noise, uniformity, exposure calibration, linearity, low-contrast and spatial resolution, spatial accuracy, laser beam function and erasure thoroughness. CR devices from two major manufacturers were evaluated. We investigated several approaches to quantify the detector response uniformity. We developed methods to characterize the spatial accuracy and resolution properties across the entire image area, based on the Fourier analysis of the image of a fine wire mesh. The implemented methods were sensitive to local blurring and allowed us to detect a local distortion of 4% or greater in any part of an imaging plate. The obtained results showed that the developed image processing tools allow us to implement a quality control program for CR with short processing time and with absence of subjectivity in the evaluation of the parameters.


Asunto(s)
Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Radiografía/métodos , Tecnología Radiológica/métodos , Calibración , Análisis de Fourier , Humanos , Procesamiento de Imagen Asistido por Computador , Rayos Láser , Modelos Estadísticos , Fantasmas de Imagen , Control de Calidad , Dosis de Radiación , Reproducibilidad de los Resultados , Factores de Tiempo
4.
Phys Med Biol ; 51(11): 2871-81, 2006 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-16723772

RESUMEN

There is a growing interest in Gafchromic films for patient dosimetry in radiotherapy and in radiology. A new model (XR-QA) with high sensitivity to low dose was tested in this study. The response of the film to different x-ray beam energies (range 28-145 kVp with various filtrations, dose range 0-100 mGy) and to visible light was investigated, together with the after exposure darkening properties. Exposed films were digitized with a commercially available, optical flatbed scanner. A single functional form for dose versus net pixel value variation has been determined for all the obtained calibration curves, with a unique fit parameter different for each of the used x-ray beams. The film response was dependent on beam energy, with higher colour variations for the beams in the range 80-140 kVp. Different sources of uncertainties in dose measurements, governed by the digitalization process, the film response uniformity and the calibration curve fit procedure, have been considered. The overall one-sigma dose measurement uncertainty depended on the beam energy and decreased with increasing absorbed dose. For doses above 10 mGy and beam energies in the range 80-140 kVp the total uncertainty was less than 5%, whereas for the 28 kVp beam the total uncertainty at 10 mGy was about 10%. The post-exposure colour variation was not negligible in the first 24 h after the exposure, with a consequent increase in the calculated dose of about 10%. Results of the analysis of the sensitivity to visible light indicated that a short exposure of this film to ambient and scanner light during the measurements will not have a significant impact on the radiation dosimetry.


Asunto(s)
Dosimetría por Película/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Película para Rayos X , Calibración , Relación Dosis-Respuesta en la Radiación , Dosimetría por Película/instrumentación , Humanos , Dosis de Radiación , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/instrumentación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Factores de Tiempo , Rayos X
5.
Phys Med Biol ; 51(23): N403-9, 2006 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-17110757

RESUMEN

Gafchromic XR-R films are a useful tool to evaluate entrance skin dose in interventional radiology. Another dosimetric quantity of interest in diagnostic and interventional radiology is the dose area product (DAP). In this study, a method to evaluate DAP using Gafchromic XR-R films and a flat-bed scanner was developed and tested. Film samples were exposed to an x-ray beam of 80 kVp over a dose range of 0-10 Gy. DAP measurements with films were obtained from the digitalization of a film sample positioned over the x-ray beam window during the exposure. DAP values obtained with this method were compared for 23 cardiological interventional procedures with DAP values displayed by the equipment. The overall one-sigma dose measurement uncertainty depended on the absorbed dose, with values below 6% for doses above 1 Gy. A maximum discrepancy of 16% was found, which is of the order of the differences in the DAP measurements that may occur with different calibration procedures. Based on the results presented, after an accurate calibration procedure and a thorough inspection of the relationship between the actual dose and the direct measured quantity (net optical density or net pixel value variation), Gafchromic XR-R films can be used to assess the DAP.


Asunto(s)
Radiometría/estadística & datos numéricos , Fenómenos Biofísicos , Biofisica , Relación Dosis-Respuesta en la Radiación , Dosimetría por Película/estadística & datos numéricos , Humanos , Intensificación de Imagen Radiográfica , Radiología Intervencionista/estadística & datos numéricos , Piel/efectos de la radiación , Película para Rayos X
6.
Radiat Prot Dosimetry ; 117(1-3): 256-9, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-16461490

RESUMEN

Dose estimation in interventional neuroradiology can be useful to limit skin radiation injuries. The purpose of this study was to evaluate the role of entrance skin dose (ESD) maps in planning exposure condition optimisation. Thirteen cerebral angiography and five embolisation procedures were monitored, measuring ESD, dose-area product (DAP) and other operational parameters. A transmission ionisation chamber, simultaneously measuring air kerma and DAP, measured dose-related quantities. Data acquisition software collected dosimetric and geometrical data during the interventional procedure and provided a distribution map of ESD on a standard phantom digital image, with maximum value estimation. Values of 88-1710 mGy for maximum skin dose and 16.7-343 Gy cm2 for DAP were found. These data confirm the possibility of deterministic effects during therapeutic interventional neuroradiological procedures like cerebral embolisation. ESD maps are useful to retrospectively study the exposure characteristics of a procedure and plan patient exposure optimisation.


Asunto(s)
Angiografía Cerebral/métodos , Embolización Terapéutica/métodos , Neurorradiografía/métodos , Radiología Intervencionista/métodos , Radiometría/métodos , Piel/efectos de la radiación , Adulto , Anciano , Relación Dosis-Respuesta en la Radiación , Fluoroscopía/métodos , Humanos , Persona de Mediana Edad , Dosis de Radiación , Factores de Tiempo
7.
Med Phys ; 31(8): 2356-61, 2004 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-15377102

RESUMEN

Interventional neuroradiology can involve very high entrance skin doses to patients and has the potential to induce deterministic radiation effects to the skin. A monitoring system indicating the maximum entrance skin dose during procedures could be useful to avoid skin injuries and to optimize technical parameters. Such evaluation is difficult, because exposure conditions change many times during each procedure. A data acquisition system for real time estimation of patient dose was developed, using a transmission ionization chamber connected to a personal computer, simultaneously measuring air kerma and dose area product. Input data were processed by a software that provided a map of entrance skin dose and stored all the information in a database. The method was first applied during 16 interventional procedures and was found to be suitable to this application thanks to the short time necessary for dose measurements, simplicity of use and absence of interference with the procedure execution. The uncertainty of estimation of maximum entrance skin dose was evaluated to be about 20% at the 1 sigma level.


Asunto(s)
Algoritmos , Neurorradiografía , Piel/efectos de la radiación , Programas Informáticos , Humanos , Dosis de Radiación
8.
Br J Radiol ; 76(902): 129-31, 2003 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-12642282

RESUMEN

The National Radiological Protection Board has recommended the introduction of dose-width product (DWP) for the measurement of patient dose in panoramic dental radiology. The present work describes a method for measuring DWP using a pencil ionization chamber. The technique was tested on five panoramic dental units; the reproducibility of the method was 5.7%. In order to test the method, DWP was also assessed using thermoluminescent dosemeters and film. The results obtained agreed within 8.6% with those obtained using the pencil ionization chamber method. The proposed method appears to be simple and precise.


Asunto(s)
Monitoreo de Radiación/métodos , Radiografía Panorámica , Humanos , Dosis de Radiación , Radiometría , Reproducibilidad de los Resultados
9.
Tumori ; 88(3): S7-8, 2002.
Artículo en Inglés | MEDLINE | ID: mdl-12365392

RESUMEN

AIMS AND BACKGROUND: Peritumoral injection of 99mTc-labeled colloids for lymphoscintigraphy and radioguided surgery does not entail any relevant radiation burden to the patients. The real issue about radiation protection concerns the personnel involved in the procedure besides the nuclear medicine personnel. The aim of our study was to evaluate the cumulative doses to personnel involved during the injection of radiolabeled compounds, under ultrasound or stereotactic guidance and the radiation burden to the personnel involved in the surgical incision of the tumor 24 hours after the administration of 99mTc-labeled colloids. METHODS AND STUDY DESIGN: We performed environmental contamination tests (SMEAR TEST) and exposure evaluation in the operating room. RESULTS: In the operating room the removed activity in the analyzed samples was less than 0.5 Bq/g and exposure to the personnel was less than 6 micro Sv/h. The evaluations made during ultrasound guidance demonstrated an equivalent and effective dose less than 20 microSv. CONCLUSIONS: Our results show that during ultrasound or stereotactic administration of radiolabeled compounds the radiation burden to the personnel involved in the procedure is virtually negligible. The surgeons too are exposed to a negligible radiation dose.


Asunto(s)
Personal de Salud , Metástasis Linfática/diagnóstico por imagen , Exposición Profesional/efectos adversos , Traumatismos por Radiación/prevención & control , Radiometría , Radiofármacos/administración & dosificación , Biopsia del Ganglio Linfático Centinela/métodos , Agregado de Albúmina Marcado con Tecnecio Tc 99m/administración & dosificación , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Traumatismos por Radiación/etiología , Cintigrafía , Radiofármacos/efectos adversos , Agregado de Albúmina Marcado con Tecnecio Tc 99m/efectos adversos
10.
Health Phys ; 73(3): 498-501, 1997 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-9287092

RESUMEN

Measurements of 137Cs contamination in the urine of 37 individuals were performed in 1995 and 1996 in order to evaluate the 137Cs daily urinary excretion in the northwestern italian people ten years from the Chernobyl accident. The difference between the average 137Cs daily urinary excretion assessed for 1995 and for 1996 was not statistically significant. Using the values of urine contamination, an estimate of 0.2 Bq(-1) of mean ingested activity was obtained. A mean committed effective dose of about 1 microSv was determined as due to the 137Cs ingestion during 1 y at 10 y after the accident. Such a dose is lower by a factor of 10(3) than the corresponding value for the population of North Italy in the first year following the Chernobyl accident.


Asunto(s)
Radioisótopos de Cesio/orina , Liberación de Radiactividad Peligrosa , Adulto , Carga Corporal (Radioterapia) , Femenino , Contaminación Radiactiva de Alimentos , Física Sanitaria , Humanos , Italia , Masculino , Persona de Mediana Edad , Dosis de Radiación , Factores de Tiempo , Ucrania
11.
Health Phys ; 64(5): 479-84, 1993 May.
Artículo en Inglés | MEDLINE | ID: mdl-8491598

RESUMEN

After the Chernobyl accident, several radionuclides were deposited on the soil of the Piemonte Region in Italy. Contamination values were monitored and the initial vertical soil profiles of 134Cs and 106Ru were determined. For both radionuclides, more than 60% of the total activity remained in the upper 1-cm layer of soil during the first 7 mo after the accident. The time history of the soil profiles was studied over a period of 3 y in two Piedmontese localities. A compartmental model was also developed to describe downward migration of 134Cs and 106Ru. The results indicated a low mobility for both radionuclides. The change in their vertical profiles may be described using a box model with a transfer constant of 0.2 y-1 for 134Cs and 0.3 y-1 for 106Ru between 1-cm-thick layers. A strong association between the soil fine fraction and the mobility of both radionuclides was also found.


Asunto(s)
Accidentes , Radioisótopos de Cesio/análisis , Reactores Nucleares , Radioisótopos de Rutenio/análisis , Contaminantes Radiactivos del Suelo/análisis , Humanos , Italia , Ucrania
12.
Phys Med ; 30(1): 18-24, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22749733

RESUMEN

Dental CT dose evaluations are commonly performed using thermoluminescent dosimeters (TLD) inside anthropomorphic phantoms. Radiochromic films with good sensitivity in the X-ray diagnostic field have recently been developed and are commercially available as GAFCHROMIC XR-QA. There are potential advantages in the use of radiochromic films such as a more comprehensive dosimetry thanks to the adjustable size of the film samples. The purpose of this study was to investigate the feasibility of using radiochromic films for dental CT dose evaluations. Film samples were cut with a width of 5mm and a length of 25 mm (strips), the same size as the Alderson Rando anthropomorphic phantom holes used in this study. Dental CT dose measurements were performed using simultaneously both TLD and radiochromic strips in the same phantom sites. Two equipment types were considered for dental CT examinations: a 16 slice CT and a cone beam CT. Organ equivalent doses were then obtained averaging the measurements from the sites of the same organ and effective doses were calculated using ICRP 103 weighting factors. The entire procedure was repeated four times for each CT in order to compare also the repeatability of the two dosimeter types. A linear correlation was found between the absorbed dose evaluated with radiochromic films and with TLD, with slopes of 0.930 and 0.944 (correlation r>0.99). The maximum difference between the two dosimeter's measurements was 25%, whereas the average difference was 7%. The measurement repeatability was comparable for the two dosimeters at cumulative doses above 15 mGy (estimated uncertainty at 1 sigma level of about 5%), whereas below this threshold radiochromic films show a greater dispersion of data, of about 10% at 1 sigma level. We obtained, using respectively Gafchromic and TLD measurements, effective dose values of 107 µSv and 117 µSv (i.e. difference of 8.6%) for the cone beam CT and of 523 µSv and 562 µSv (i.e. difference of 7%) for the multislice CT. This study demonstrates the feasibility of radiochromic films for dental CT dosimetry, pointing out a good agreement with the results obtained using TLD, with potential advantages and the chance of a more extensive dose investigation.


Asunto(s)
Odontología , Dosimetría por Película/métodos , Tomografía Computarizada por Rayos X , Estudios de Factibilidad , Humanos , Fantasmas de Imagen , Dosis de Radiación
13.
Eur J Radiol ; 81(11): 3172-7, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22817847

RESUMEN

OBJECTIVE: This study aims to investigate the consequences on dose and image quality of the choices of different combinations of NI and adaptive statistical iterative reconstruction (ASIR) percentage, the image quality parameters of GE CT equipment. METHODS: An anthropomorphic phantom was used to simulate the chest and upper abdomen of a standard weight patient. Images were acquired with tube current modulation and different values of noise index, in the range 10-22 for a slice thickness of 5mm and a tube voltage of 120 kV. For each selected noise index, several image series were reconstructed using different percentages of ASIR (0, 40, 50, 60, 70, 100). Quantitative noise was assessed at different phantom locations. Computed tomography dose index (CTDI) and dose length products (DLP) were recorded. Three radiologists reviewed the images in a blinded and randomized manner and assessed the subjective image quality by comparing the image series with the one acquired with the reference protocol (noise index 14, ASIR 40%). The perceived noise, contrast, edge sharpness and overall quality were graded on a scale from -2 (much worse) to +2 (much better). RESULTS: A repeatable trend of noise reduction versus the percentage of ASIR was observed for different noise levels and phantom locations. The different combinations of noise index and percentage of ASIR to obtain a desired dose reduction were assessed. The subjective image quality evaluation evidenced a possible dose reduction between 24 and 40% as a consequence of an increment of ASIR percentage to 50 or 70%, respectively. CONCLUSION: These results highlighted that the same patient dose reduction can be obtained with several combinations of noise index and percentages of ASIR, providing a model with which to choose these acquisition parameters in future optimization studies, with the aim of reducing patient dose by maintaining image quality in diagnostic levels.


Asunto(s)
Algoritmos , Antropometría/instrumentación , Fantasmas de Imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
15.
Eur J Radiol ; 72(1): 181-7, 2009 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-18692337

RESUMEN

The purpose of this study was to evaluate the consequences of different choices of acquisition parameters on the actual image noise and on the patient dose with an automatic tube current modulation system. The CT investigated was a GE Lightspeed 16-slice and an anthropomorphic phantom was used to simulate the patient. Several acquisitions were made varying noise index (NI), kilovoltage and pitch values. Tube current values were compared for the different acquisitions. Patient dose was evaluated in terms of volumetric computed tomography dose index (CTDI(vol)) and also as effective dose. The noise actually present in the images was analyzed by a region of interest analysis considering representatively phantom sections in the regions of the shoulders, of the lungs and of the abdomen. The obtained results generally evidenced a good agreement between the noise index and the measured noise for the abdomen sections, whereas for the shoulders and the lungs sections the measured noise was respectively greater and lower of the NI. Varying the kV the automatic current modulation system provided images with a substantially constancy of the actual noise and of the patient dose. An increase of the pitch generally decreased the patient dose, whereas the noise was slightly greater for the lowest pitch and almost constant for the other pitch values. This study outlines some important relationships between an automatic tube current modulation system and other CT acquisition parameters, providing useful informations for the choice requested by radiologists in the task of optimization of the CT acquisition protocols. Unless there are other considerations in place, pixel pitches below 1.375 should be avoided, and kVp settings can be changed with no real impact on dose or image noise.


Asunto(s)
Carga Corporal (Radioterapia) , Dosis de Radiación , Intensificación de Imagen Radiográfica/instrumentación , Intensificación de Imagen Radiográfica/métodos , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Fantasmas de Imagen , Radiometría , Rayos X
16.
Radiol Med ; 114(4): 595-607, 2009 Jun.
Artículo en Inglés, Italiano | MEDLINE | ID: mdl-19444592

RESUMEN

PURPOSE: The purpose of this study was to compare exposure of patient and operator to ionising radiation during percutaneous vertebroplasty performed under combined computed tomography (CT) and fluoroscopic guidance or fluoroscopic guidance alone. MATERIALS AND METHODS: With the collaboration of our physics department, we measured exposure on ten patients undergoing vertebroplasty with combined CT and fluoroscopic guidance and on ten undergoing vertebroplasty with fluoroscopic guidance alone. RESULTS: Mean operator dose was approximately 0.8 microSv during vertebroplasty done with combined CT and fluoroscopic guidance and 5.8 microSv in procedures with fluoroscopic guidance alone. Mean patient dose was approximately 6 mSv for combined guidance and 8 mSv for fluoroscopic guidance, a difference that was not found to be statistically significant. CONCLUSIONS: Although combined CT and fluoroscopic guidance is normally preferred for difficult areas such as the cervical and upper thoracic vertebrae, to ensure operator radiation protection, the technique should also be considered for areas normally treated under fluoroscopic guidance alone. However, a larger patient series is needed to correctly evaluate the real contribution of low-dose CT to patient exposure.


Asunto(s)
Fluoroscopía/efectos adversos , Exposición Profesional/análisis , Monitoreo de Radiación/métodos , Radiografía Intervencional/métodos , Vertebroplastia/métodos , Algoritmos , Vértebras Cervicales/diagnóstico por imagen , Vértebras Cervicales/cirugía , Fluoroscopía/métodos , Humanos , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/cirugía , Exposición Profesional/prevención & control , Dosis de Radiación , Radiación Ionizante , Vértebras Torácicas/diagnóstico por imagen , Vértebras Torácicas/cirugía
17.
Radiol Med ; 113(8): 1219-28, 2008 Dec.
Artículo en Inglés, Italiano | MEDLINE | ID: mdl-18956145

RESUMEN

PURPOSE: The purpose of this work was to evaluate the statistical distribution of patient dose for different examinations by using the data stored in a DICOM image archive of a direct digital radiography system. MATERIALS AND METHODS: An automatic procedure to extract dose data and exposure parameters from the image archives was implemented. During a 4.5-month period, 8,292 images were collected. Exposure parameters and the air kerma area product (P (KA)) stored in the image DICOM header were examined for each image. The entrance surface air kerma (K (a,e)), a quantity comparable to the current diagnostic reference levels (DRL), was estimated considering the P (KA) and the geometric parameters of each examination. RESULTS: P (KA) and K (a,e ) distributions showed highly variable values. The obtained K (a,e ) values were substantially lower than the DRL. DRL were more than six times the mean value of K (a,e ) distribution for the abdomen anteroposterior (AP) and lumbar spine lateral (LAT) projections, whereas the ratio was equal to 2.7 for posteroanterior (PA) chest examinations. CONCLUSIONS: The method adopted proved to be effective for characterising the dose of each examination by means of the statistical analysis of the dose quantities over extensive samples. The dose values obtained and the comparison with the DRL showed that this radiographic device allows substantial dose savings compared with estimations made for nondigital or for phosphor-based systems.


Asunto(s)
Dosis de Radiación , Intensificación de Imagen Radiográfica , Distribuciones Estadísticas , Humanos
18.
Radiol Med ; 113(8): 1229-40, 2008 Dec.
Artículo en Inglés, Italiano | MEDLINE | ID: mdl-18956149

RESUMEN

PURPOSE: The purpose of this study was to evaluate the radiation dose to patients during radiological contrast studies performed after vertical banded gastroplasty (VBG) or Roux-en-Y gastric bypass (RYGBP) surgery in patients with morbid obesity. MATERIALS AND METHODS: Dose evaluations were performed on a sample of 39 patients (32 women and 7 men) with a mean weight of 117 kg (range 68-175 kg) and a mean body mass index (BMI) of 43.7 (range 22.2-54.9). Between the second and seventh postoperative day, patients underwent radiological follow-up after oral administration of approximately 70 ml of water-soluble iodinated contrast material (Gastrografin) and images acquired in anteroposterior, right and left oblique projections with the patient upright and then supine. Exposure conditions, dose-area product (DAP) and entrance skin dose (ESD) were recorded for each procedure. On the basis of these data, the effective dose (ED) was calculated using simulation software based on the Monte Carlo method for determining the absorbed dose to organs. To assess the optimal exposure conditions and the dose contributions of fluoroscopy and radiography, the effective dose rates were also evaluated using Plexiglas phantoms of different thickness to simulate different patient sizes. RESULTS: The phantom measurements showed a fourfold dose increase when passing from normal-sized patients to obese patients. Mean DAP value obtained from in-vivo measurements was 70 Gy cm(2) (range 17-147 Gy cm(2)), and mean effective dose was 21 mSv (range 5-45 mSv). CONCLUSIONS: When performing radiological contrast studies in patients with morbid obesity, every possible precaution should be taken to minimise patient dose. Special care should be taken to evaluate justification of the radiological procedure.


Asunto(s)
Medios de Contraste , Derivación Gástrica , Gastroplastia , Obesidad Mórbida/diagnóstico por imagen , Obesidad Mórbida/cirugía , Dosis de Radiación , Adolescente , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Radiografía , Adulto Joven
19.
Radiol Med ; 113(3): 429-38, 2008 Apr.
Artículo en Inglés, Italiano | MEDLINE | ID: mdl-18493778

RESUMEN

PURPOSE: This study was undertaken to evaluate patient dose in paediatric liver transplant recipients treated by percutaneous biliary drainage and bilioplasty procedures. MATERIALS AND METHODS: Effective dose rates and entrance skin-dose (ESD) rates per minute of fluoroscopy were measured by using a plexiglas phantom (thickness 10 cm) simulating the patient and by varying the exposure parameters (type of pulsed fluoroscopy, image intensifier diameter, presence of diaphragms) to identify the technique delivering the lowest patient dose. In vivo measurements were performed during three interventional procedures. RESULTS: The effective dose rate proved to be lowest for a particular type of pulsed fluoroscopy, with maximum magnification and with field-limiting diaphragms. The in vivo measurements showed a maximum ESD value of around 50 MGY (the threshold for transient erythema is 2,000 MGY, ICRP 60). The effective dose values were in the range of 0.9-1.5 MSV. CONCLUSIONS: We established exposure parameters providing the desired image quality with the lowest dose for the equipment used and for a specific type of interventional procedure. The measured ESD values allow us to exclude the risk of deterministic effects on the skin. The effective dose values and considerations regarding the likelihood of radiation-induced cancer led to the conclusion that the radiological risk for the patient is largely justified by the benefits of these kinds of procedure.


Asunto(s)
Enfermedades de los Conductos Biliares/terapia , Conductos Biliares/cirugía , Procedimientos Quirúrgicos del Sistema Biliar/métodos , Drenaje/métodos , Trasplante de Hígado , Enfermedades de los Conductos Biliares/diagnóstico por imagen , Enfermedades de los Conductos Biliares/etiología , Cateterismo , Preescolar , Colangiografía , Colangiopancreatografia Retrógrada Endoscópica , Femenino , Fluoroscopía , Humanos , Lactante , Masculino , Dosis de Radiación , Traumatismos por Radiación/prevención & control , Monitoreo de Radiación/métodos , Radiografía Intervencional , Estudios Retrospectivos
20.
Radiol Med ; 111(8): 1156-67, 2006 Dec.
Artículo en Inglés, Italiano | MEDLINE | ID: mdl-17171519

RESUMEN

PURPOSE: The purpose of this paper is to describe the automation of quality control procedures on photo-stimulable imaging plates by means of an image-processing tool providing automatic reading of the images and automatic calculation of the quality parameters monitored. MATERIALS AND METHODS: Quality-control procedures were performed according to the main available guidelines. The quality assurance programme was applied to several Kodak and Philips devices in four radiological departments. The automatic image-processing tool was developed using public domain software (Java-based ImageJ software) and contains both reading and computation procedures. RESULTS: The quality checks and algorithms described were successfully applied, proving useful for identification of defective plates and for implementation of the quality assurance programme. The use of automation allowed significant savings in the time required for quality checks. CONCLUSIONS: Completely automated image reading allows substantial economic and human resources savings, as it eliminates much of the transfer, reproduction, processing and filing procedures.


Asunto(s)
Garantía de la Calidad de Atención de Salud , Control de Calidad , Interpretación de Imagen Radiográfica Asistida por Computador , Algoritmos , Análisis Costo-Beneficio , Humanos , Procesamiento de Imagen Asistido por Computador/economía , Procesamiento de Imagen Asistido por Computador/métodos , Italia , Guías de Práctica Clínica como Asunto , Garantía de la Calidad de Atención de Salud/economía
SELECCIÓN DE REFERENCIAS