1.
Med Phys ; 39(11): 7102-9, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23127101

RESUMEN

PURPOSE: The authors are investigating the feasibility of a new type of solid-state x-ray imaging sensor with programmable avalanche gain: scintillator high-gain avalanche rushing photoconductor active matrix flat panel imager (SHARP-AMFPI). The purpose of the present work is to investigate the inherent x-ray detection properties of SHARP and demonstrate its wide dynamic range through programmable gain. METHODS: A distributed resistive layer (DRL) was developed to maintain stable avalanche gain operation in a solid-state HARP. The signal and noise properties of the HARP-DRL for optical photon detection were investigated as a function of avalanche gain both theoretically and experimentally, and the results were compared with HARP tube (with electron beam readout) used in previous investigations of zero spatial frequency performance of SHARP. For this new investigation, a solid-state SHARP x-ray image sensor was formed by direct optical coupling of the HARP-DRL with a structured cesium iodide (CsI) scintillator. The x-ray sensitivity of this sensor was measured as a function of avalanche gain and the results were compared with the sensitivity of HARP-DRL measured optically. The dynamic range of HARP-DRL with variable avalanche gain was investigated for the entire exposure range encountered in radiography∕fluoroscopy (R∕F) applications. RESULTS: The signal from HARP-DRL as a function of electric field showed stable avalanche gain, and the noise associated with the avalanche process agrees well with theory and previous measurements from a HARP tube. This result indicates that when coupled with CsI for x-ray detection, the additional noise associated with avalanche gain in HARP-DRL is negligible. The x-ray sensitivity measurements using the SHARP sensor produced identical avalanche gain dependence on electric field as the optical measurements with HARP-DRL. Adjusting the avalanche multiplication gain in HARP-DRL enabled a very wide dynamic range which encompassed all clinically relevant medical x-ray exposures. CONCLUSIONS: This work demonstrates that the HARP-DRL sensor enables the practical implementation of a SHARP solid-state x-ray sensor capable of quantum noise limited operation throughout the entire range of clinically relevant x-ray exposures. This is an important step toward the realization of a SHARP-AMFPI x-ray flat-panel imager.


Asunto(s)
Fluoroscopía/instrumentación , Conteo por Cintilación/instrumentación , Dosis de Radiación
2.
Med Phys ; 37(9): 4982-5, 2010 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-20964217

RESUMEN

PURPOSE: The feasibility of a practical solid-state technology for low photon flux imaging applications was investigated. The technology is based on an amorphous selenium photoreceptor with a voltage-controlled avalanche multiplication gain. If this photoreceptor can provide sufficient internal gain, it will be useful for an extensive range of diagnostic imaging systems. METHODS: The avalanche photoreceptor under investigation is referred to as HARP-DRL. This is a novel concept in which a high-gain avalanche rushing photoconductor (HARP) is integrated with a distributed resistance layer (DRL) and sandwiched between two electrodes. The avalanche gain and leakage current characteristics of this photoreceptor were measured. RESULTS: HARP-DRL has been found to sustain very high electric field strengths without electrical breakdown. It has shown avalanche multiplication gains as high as 10(4) and a very low leakage current (< or = 20 pA/mm2). CONCLUSIONS: This is the first experimental demonstration of a solid-state amorphous photoreceptor which provides sufficient internal avalanche gain for photon counting and photon starved imaging applications.


Asunto(s)
Diagnóstico por Imagen/métodos , Fotones , Selenio/química , Conductividad Eléctrica , Electrodos
3.
Med Phys ; 37(3): 1339-49, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-20384271

RESUMEN

PURPOSE: A numerical model and the experimental methods to study the x-ray exposure dependent change in the modulation transfer function (MTF) of amorphous selenium (a-Se) based active matrix flat panel imagers (AMFPIs) are described. The physical mechanisms responsible for the x-ray exposure dependent change in MTF are also investigated. METHODS: A numerical model for describing the x-ray exposure dependent MTF of a-Se based AMFPIs has been developed. The x-ray sensitivity and MTF of an a-Se AMFPI have been measured as a function of exposure. The instantaneous electric field and free and trapped carrier distributions in the photoconductor layer are obtained by numerically solving the Poisson's equation, continuity equations, and trapping rate equations using the backward Euler finite difference method. From the trapped carrier distributions, a method for calculating the MTF due to incomplete charge collection is proposed. RESULTS: The model developed in this work and the experimental data show a reasonably good agreement. The model is able to simultaneously predict the dependence of the sensitivity and MTF on accumulated exposure at different applied fields and bias polarities, with the same charge transport parameters that are typical of the particular a-Se photoconductive layer that is used in these AMFPIs. Under negative bias, the MTF actually improves with the accumulated x-ray exposure while the sensitivity decreases. The MTF enhancement with exposure decreases with increasing applied field. CONCLUSIONS: The most prevalent processes that control the MTF under negative bias are the recombination of drifting holes with previously trapped electrons (electrons remain in deep traps due to their long release times compared with the time scale of the experiments) and the deep trapping of drifting holes and electrons.


Asunto(s)
Selenio/efectos de la radiación , Pantallas Intensificadoras de Rayos X , Relación Dosis-Respuesta en la Radiación , Diseño de Equipo , Análisis de Falla de Equipo , Dosis de Radiación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
4.
Med Phys ; 36(4): 1086-97, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19472613

RESUMEN

A hybrid closed-bore x-ray/MRI system (CBXMR) is proposed to improve the safety and efficacy of percutaneous aortic valve replacement procedures. In this system, an x-ray C-arm will be positioned about 1 m from the entrance of a 1.5 T MRI scanner. The CBXMR system will harness the complementary strengths of both modalities to guide and deploy a bioprosthetic valve into the aortic annulus of the heart without coronary artery obstruction. A major challenge in constructing this system is ensuring proper operation of a rotating-anode x-ray tube in the MRI magnetic fringe field environment. The electron beam in the x-ray tube responsible for producing x rays can be deflected by the fringe field. However, the clinical impact of electron beam deflection in a magnetic field has not yet been studied. Here, the authors investigated changes in focal spot resolving power, field of view shift, and field of view truncation in x-ray images as a result of electron beam deflection. The authors found that in the fringe field acting on the x-ray tube at the clinical location for the x-ray C-arm (4 mT), focal spot size increased by only 2%, so the fringe field did not limit the resolving power of the x-ray system. The magnetic field also caused the field of view to shift by 3 mm. This shift must be corrected to avoid unnecessary primary radiation exposure to the patient and the staff in the cardiac catheterization laboratory. The fringe field was too weak to cause field of view truncation.


Asunto(s)
Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Válvula Aórtica/diagnóstico por imagen , Cateterismo Cardíaco , Campos Electromagnéticos , Electrones , Diseño de Equipo , Humanos , Imagen por Resonancia Magnética/métodos , Magnetismo , Modelos Estadísticos , Fantasmas de Imagen , Radiografía , Rayos X
5.
Med Phys ; 36(5): 1717-26, 2009 May.
Artículo en Inglés | MEDLINE | ID: mdl-19544789

RESUMEN

Hybrid closed bore x-ray/MRI systems are being developed to improve the safety and efficacy of percutaneous aortic valve replacement procedures by harnessing the complementary strengths of the x-ray and MRI modalities in a single interventional suite without requiring patient transfer between two rooms. These systems are composed of an x-ray C-arm in close proximity (approximately 1 m) to an MRI scanner. The MRI magnetic fringe field can cause the electron beam in the x-ray tube to deflect. The deflection causes the x-ray field of view to shift position on the detector receptacle. This could result in unnecessary radiation exposure to the patient and the staff in the cardiac catheterization laboratory. Therefore, the electron beam deflection must be corrected. The authors developed an active magnetic shielding system that can correct for electron beam deflection to within an accuracy of 5% without truncating the field of view or increasing exposure to the patient. This system was able to automatically adjust to different field strengths as the external magnetic field acting on the x-ray tube was changed. Although a small torque was observed on the shielding coils of the active shielding system when they were placed in a magnetic field, this torque will not impact their performance if they are securely mounted on the x-ray tube and the C-arm. The heating of the coils of the shielding system for use in the clinic caused by electric current was found to be slow enough not to require a dedicated cooling system for one percutaneous aortic valve replacement procedure. However, a cooling system will be required if multiple procedures are performed in one session.


Asunto(s)
Aorta/cirugía , Aortografía/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Aumento de la Imagen/instrumentación , Imagen por Resonancia Magnética/instrumentación , Magnetismo/instrumentación , Protección Radiológica/instrumentación , Diseño Asistido por Computadora , Diseño de Equipo , Análisis de Falla de Equipo , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Aumento de la Imagen/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
6.
Med Phys ; 35(12): 5207-18, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19175080

RESUMEN

The authors are investigating the concept of a direct-conversion flat-panel imager with avalanche gain for low-dose x-ray imaging. It consists of an amorphous selenium (a-Se) photoconductor partitioned into a thick drift region for x-ray-to-charge conversion and a relatively thin region called high-gain avalanche rushing photoconductor (HARP) in which the charge undergoes avalanche multiplication. An active matrix of thin film transistors is used to read out the electronic image. The authors call the proposed imager HARP active matrix flat panel imager (HARP-AMFPI). The key advantages of HARP-AMFPI are its high spatial resolution, owing to the direct-conversion a-Se layer, and its programmable avalanche gain, which can be enabled during low dose fluoroscopy to overcome electronic noise and disabled during high dose radiography to prevent saturation of the detector elements. This article investigates key design considerations for HARP-AMFPI. The effects of electronic noise on the imaging performance of HARP-AMFPI were modeled theoretically and system parameters were optimized for radiography and fluoroscopy. The following imager properties were determined as a function of avalanche gain: (1) the spatial frequency dependent detective quantum efficiency; (2) fill factor; (3) dynamic range and linearity; and (4) gain nonuniformities resulting from electric field strength nonuniformities. The authors results showed that avalanche gains of 5 and 20 enable x-ray quantum noise limited performance throughout the entire exposure range in radiography and fluoroscopy, respectively. It was shown that HARP-AMFPI can provide the required gain while maintaining a 100% effective fill factor and a piecewise dynamic range over five orders of magnitude (10(-7)-10(-2) R/frame). The authors have also shown that imaging performance is not significantly affected by the following: electric field strength nonuniformities, avalanche noise for x-ray energies above 1 keV and direct interaction of x rays in the gain region. Thus, HARP-AMFPI is a promising flat-panel imager structure that enables high-resolution fully quantum noise limited x-ray imaging over a wide exposure range.


Asunto(s)
Diagnóstico por Imagen/instrumentación , Radiografía/instrumentación , Algoritmos , Tecnología Biomédica , Diagnóstico por Imagen/métodos , Electrónica , Diseño de Equipo , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Mamografía/instrumentación , Modelos Estadísticos , Fantasmas de Imagen , Teoría Cuántica , Radiografía/métodos , Selenio , Pantallas Intensificadoras de Rayos X , Rayos X
7.
Med Phys ; 35(10): 4474-87, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-18975695

RESUMEN

Nanostructures represent a promising new type of contrast agent for clinical medical imaging modalities, including magnetic resonance imaging, x-ray computed tomography, ultrasound, and nuclear imaging. Currently, most nanostructures are simple, single-purpose imaging agents based on spherical constructs (e.g., liposomes, micelles, nanoemulsions, macromolecules, dendrimers, and solid nanoparticle structures). In the next decade, new clinical imaging nanostructures will be designed as multi-functional constructs, to both amplify imaging signals at disease sites and deliver localized therapy. Proposals for nanostructures to fulfill these new functions will be outlined. New functional nanostructures are expected to develop in five main directions: Modular nanostructures with additive functionality; cooperative nanostructures with synergistic functionality; nanostructures activated by their in vivo environment; nanostructures activated by sources outside the patient; and novel, nonspherical nanostructures and components. The development and clinical translation of next-generation nanostructures will be facilitated by a combination of improved clarity of the in vivo imaging and biological challenges and the requirements to successfully overcome them; development of standardized characterization and validation systems tailored for the preclinical assessment of nanostructure agents; and development of streamlined commercialization strategies and pipelines tailored for nanostructure-based agents for their efficient translation to the clinic.


Asunto(s)
Medios de Contraste , Diagnóstico por Imagen/tendencias , Predicción , Aumento de la Imagen/métodos , Técnicas de Sonda Molecular/tendencias , Nanoestructuras
8.
Med Phys ; 35(3): 939-49, 2008 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-18404930

RESUMEN

New x-ray radiographic systems based on large-area flat-panel technology have revolutionized our capability to produce digital x-ray images. However, these imagers are extraordinarily expensive compared to the systems they are replacing. Hence, there is a need for a low-cost digital imaging system for general applications in radiology. A novel potentially low-cost radiographic imaging system based on established technologies is proposed-the X-Ray Light Valve (XLV). This is a potentially high-quality digital x-ray detector made of a photoconducting layer and a liquid-crystal cell, physically coupled in a sandwich structure. Upon exposure to x rays, charge is collected on the surface of the photoconductor. This causes a change in the optical properties of the liquid-crystal cell and a visible image is generated. Subsequently, it is digitized by a scanned optical imager. The image formation is based on controlled modulation of light from an external source. The operation and practical implementation of the XLV system are described. The potential performance of the complete system and issues related to sensitivity, spatial resolution, noise, and speed are discussed. The feasibility of clinical use of an XLV device based on amorphous selenium (a-Se) as the photoconductor and a reflective electrically controlled birefringence cell is analyzed. The results of our analysis indicate that the XLV can potentially be adapted to a wide variety of radiographic tasks.


Asunto(s)
Intensificación de Imagen Radiográfica/economía , Intensificación de Imagen Radiográfica/instrumentación , Costos y Análisis de Costo , Capacidad Eléctrica , Factores de Tiempo , Rayos X
9.
Med Phys ; 35(12): 5672-83, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19175124

RESUMEN

The x-ray light valve (XLV) is a novel, potentially low-cost, x-ray detector that converts an x-ray exposure into an optical image stored in a liquid crystal cell. This optical image is then transferred from the liquid crystal cell to a computer through an optical-to-digital imaging readout system. Previously, CCD-based cameras were used for the optical readout, but recently it was proposed that an inexpensive optical scanner, such as an office document scanner, is a better match to the optical properties of the XLV. A methodology for characterizing a document scanner's ability to produce medical quality images from the XLV is outlined and tested on a particular scanner (Canon LiDE 30). This scanner was shown to have key characteristics of a medical device-a linear response, dynamic range sufficient for chest radiography (although not mammography) in a single pass, and an MTF and NPS that exceed the requirements for all medical applications of the scanner. This combination of criteria shows that a document scanner can be used as a digitization method for the XLV.


Asunto(s)
Interpretación de Imagen Radiográfica Asistida por Computador/instrumentación , Rayos X , Calibración , Diseño de Equipo , Equipos y Suministros , Humanos , Mamografía/métodos , Modelos Estadísticos , Óptica y Fotónica , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Programas Informáticos , Factores de Tiempo , Interfaz Usuario-Computador
10.
Med Phys ; 35(9): 4216-27, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18841872

RESUMEN

An x-ray light valve (XLV) coupled with an optical scanner has the potential to meet the need for a low-cost, high quality digital imaging system for general radiography. The XLV/scanner concept combines three well-established, and hence, low-cost technologies: An amorphous selenium (a-Se) layer as an x-ray-to-charge transducer, a liquid crystal (LC) cell as an analog display, and an optical scanner for image digitization. The XLV consists of an a-Se layer and LC cell in a sandwich structure which produces an optical image in the LC layer upon x-ray exposure. The XLV/scanner system consists of an XLV in combination with an optical scanner for image readout. Here, the effect of each component on the spatial resolution of an XLV/scanner system is investigated. A theoretical model of spatial resolution of an XLV is presented based on calculations of the modulation transfer function (MTF) for a-Se and a LC cell. From these component MTFs, the theoretical MTF of the XLV is derived. The model was validated by experiments on a prototype XLV/scanner system. The MTF of the scanner alone was obtained by scanning an optical test target and the MTF of the XLV/scanner system was measured using x rays. From the measured MTF of the scanner, the theoretical MTF of the XLV/scanner system was established and compared with the experimental results. Good general agreement exists between experimental and theoretical results in the frequency range of interest for general radiography, although the theoretical curves slightly overstate the measured MTFs. The experimental MTF of the XLV was compared with the MTF of two clinical systems and was shown to have the capability to exceed the resolution of flat-panel detectors. From this, the authors can conclude that the XLV has an adequate resolution for general radiography. The XLV/scanner also has the potential to eliminate aliasing while maintaining a MTF that exceeds that of a flat-panel imager.


Asunto(s)
Luz , Óptica y Fotónica , Rayos X , Diagnóstico por Imagen
11.
Med Phys ; 35(10): 4324-32, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-18975678

RESUMEN

Protein crystallography is the most important technique for resolving the three-dimensional atomic structure of protein by measuring the intensity of its x-ray diffraction pattern. This work proposes a large area flat panel detector for protein crystallography based on direct conversion x-ray detection technique using avalanche amorphous selenium (a-Se) as the high gain photoconductor, and active matrix readout using amorphous silicon (a-Si:H) thin film transistors. The detector employs avalanche multiplication phenomenon of a-Se to make the detector sensitive to each incident x ray. The advantages of the proposed detector over the existing imaging plate and charge coupled device detectors are large area, high dynamic range coupled to single x-ray detection capability, fast readout, high spatial resolution, and inexpensive manufacturing process. The optimal detector design parameters (such as detector size, pixel size, and thickness of a-Se layer), and operating parameters (such as electric field across the a-Se layer) are determined based on the requirements for protein crystallography application. The performance of the detector is evaluated in terms of readout time (<1 s), dynamic range (approximately 10(5)), and sensitivity (approximately 1 x-ray photon), thus validating the detector's efficacy for protein crystallography.


Asunto(s)
Cristalografía por Rayos X/instrumentación , Proteínas/ultraestructura , Transistores Electrónicos , Pantallas Intensificadoras de Rayos X , Cristalografía por Rayos X/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Estudios de Factibilidad , Reproducibilidad de los Resultados , Selenio , Sensibilidad y Especificidad
12.
Med Phys ; 35(3): 959-67, 2008 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-18404932

RESUMEN

Digital x-ray radiographic systems are desirable as they offer high quality images which can be processed, transferred, and stored without secondary steps. However, current clinical systems are extraordinarily expensive in comparison to film-based systems. Thus, there is a need for an economical digital imaging system for general radiology. The x-ray light valve (XLV) is a novel digital x-ray detector concept with the potential for high image quality and low cost. The XLV is comprised of a photoconductive detector layer and liquid crystal (LC) cell physically coupled in a sandwich structure. Upon exposure to x rays, charge is collected at the surface of the photoconductor, causing a change in the reflective properties of the LC cell. The visible image so formed can subsequently be digitized with an optical scanner. By choosing the properties of the LC cell in combination with the appropriate photoconductor thickness and bias potentials, the XLV can be optimized for various diagnostic imaging tasks. Specifically for chest radiography, we identified three potentially practical reflective cell designs by selecting from those commonly used in LC display technology. The relationship between reflectance and x-ray exposure (i.e., the characteristic curve) was determined for all three cells using a theoretical model. The results indicate that the reflective electrically controlled birefringence (r-ECB) cell is the preferred choice for chest radiography, provided that the characteristic curve can be shifted towards lower exposures. The feasibility of the shift of the characteristic curve is shown experimentally. The experimental results thus demonstrate that an XLV based on the r-ECB cell design exhibits a characteristic curve suitable for chest radiography.


Asunto(s)
Cristales Líquidos , Intensificación de Imagen Radiográfica/economía , Intensificación de Imagen Radiográfica/instrumentación , Radiografía Torácica/economía , Radiografía Torácica/instrumentación , Costos y Análisis de Costo , Rayos X
13.
Med Phys ; 35(9): 4049-62, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18841857

RESUMEN

In order to improve the safety and efficacy of percutaneous aortic valve replacement procedures, a closed bore hybrid x-ray/MRI (CBXMR) system is proposed in which an x-ray C-arm will be positioned with its isocenter approximately =1 m from the entrance of a clinical MRI scanner. This system will harness the complementary strengths of both modalities to improve clinical outcome. A key component of the CBXMR system will be a rotating anode x-ray tube to produce high-quality x-ray images. There are challenges in positioning an x-ray tube in the magnetic fringe field of the MRI magnet. Here, the effects of an external magnetic field on x-ray tube induction motors of radiography x-ray tubes and the corresponding reduction of x-ray tube heat loadability are investigated. Anode rotation frequency f(aode) was unaffected when the external magnetic field Bb was parallel to the axis of rotation of the anode but decreased when Bb was perpendicular to the axis of rotation. The experimental f(anode) values agreed with predicted values to within +/-3% over a Bb range of 0-30 mT. The MRI fringe field at the proposed location of the x-ray tube mounted on the C-arm (approximately =4 mT) reduced f(anode) by only 1%, so x-ray tube heat loadability will not be compromised when using CBXMR systems for percutaneous aortic valve replacement procedures. Eddy current heating power in the rotor due to an MRI fringe field was found to be two orders of magnitude weaker than the heating power produced on the anode due to a fluoroscopic exposure, so eddy current heating had no effect on x-ray tube heat loadability.


Asunto(s)
Válvula Aórtica/cirugía , Campos Electromagnéticos , Prótesis Valvulares Cardíacas , Calor/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Electrodos , Humanos , Imagen por Resonancia Magnética , Radiografía , Rayos X
14.
Phys Med Biol ; 53(4): 999-1013, 2008 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-18263954

RESUMEN

Cone beam digital tomosynthesis (CBDT) is a new imaging technique proposed recently as a rapid approach for creating tomographic images of a patient in the radiotherapy treatment room. The purpose of this work is to investigate the feasibility of performing megavoltage (MV) CBDT clinically. A clinical investigational MV-CBDT system was installed on an existing LINAC. After the installation, the treatment machine can be operated in two distinct modes: (1) normal clinical treatment mode; (2) CBDT mode, in which tomographic images of the patient can be obtained using MV-CBDT. Various calibration and phantom measurements were performed on the system, followed by a patient study. Our phantom measurements have shown that: (1) for the same imaging dose, MV-CBDT has the same signal-difference-to-noise ratio as megavoltage cone beam computed tomography (MV-CBCT); (2) MV-CBDT has a better spatial resolution than MV-CBCT in the planes of reconstruction but a worse spatial resolution in the direction perpendicular to the planes of reconstruction. MV-CBDT patient images were also obtained and compared to that of MV-CBCT. We have demonstrated that it is clinically feasible to perform MV-CBDT in the treatment room for image-guided radiotherapy.


Asunto(s)
Tomografía Computarizada de Haz Cónico/instrumentación , Radioterapia Asistida por Computador/métodos , Calibración , Humanos , Fantasmas de Imagen
15.
Med Phys ; 34(3): 976-86, 2007 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-17441244

RESUMEN

The past decade has seen the swift development of the flat-panel detector (FPD), also known as the active matrix flat-panel imager, for digital radiography. This new technology is applicable to other modalities, such as fluoroscopy, which require the acquisition of multiple images, but could benefit from some improvements. In such applications where more than one image is acquired less radiation is available to form each image and amplifier noise becomes a serious problem. Avalanche multiplication in amorphous selenium (a-Se) can provide the necessary amplification prior to read out so as to reduce the effect of electronic noise of the FPD. However, in direct conversion detectors avalanche multiplication can lead to a new source of gain fluctuation noise called depth dependent avalanche noise. A theoretical model was developed to understand depth dependent avalanche noise. Experiments were performed on a direct imaging system implementing avalanche multiplication in a layer of a-Se to validate the theory. For parameters appropriate for a diagnostic imaging FPD for fluoroscopy the detective quantum efficiency (DQE) was found to drop by as much as 50% with increasing electric field, as predicted by the theoretical model. This drop in DQE can be eliminated by separating the collection and avalanche regions. For example by having a region of low electric field where x rays are absorbed and converted into charge that then drifts into a region of high electric field where the x-ray generated charge undergoes avalanche multiplication. This means quantum noise limited direct conversion FPD for low exposure imaging techniques are a possibility.


Asunto(s)
Fluoroscopía/métodos , Intensificación de Imagen Radiográfica/métodos , Radiografía/métodos , Selenio/química , Artefactos , Electrones , Diseño de Equipo , Procesamiento de Imagen Asistido por Computador , Modelos Estadísticos , Modelos Teóricos , Probabilidad , Reproducibilidad de los Resultados , Pantallas Intensificadoras de Rayos X , Rayos X
16.
Med Phys ; 34(12): 4654-63, 2007 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-18196793

RESUMEN

The flat-panel detector (FPD) is the state-of-the-art detector for digital radiography. The FPD can acquire images in real-time, has superior spatial resolution, and is free of the problems of x-ray image intensifiers-veiling glare, pin-cushion and magnetic distortion. However, FPDs suffer from poor signal to noise ratio performance at typical fluoroscopic exposure rates where the quantum noise is reduced to the point that it becomes comparable to the fixed electronic noise. It has been shown previously that avalanche multiplication gain in amorphous selenium (a-Se) can provide the necessary amplification to overcome the electronic noise of the FPD. Avalanche multiplication, however, comes with its own intrinsic contribution to the noise in the form of gain fluctuation noise. In this article a cascaded systems analysis is used to present a modified metric related to the detective quantum efficiency. The modified metric is used to study a diagnostic x-ray imaging system in the presence of intrinsic avalanche multiplication noise independently from other noise sources, such as electronic noise. An indirect conversion imaging system is considered to make the study independent of other avalanche multiplication related noise sources, such as the fluctuations arising from the depth of x-ray absorption. In this case all the avalanche events are initiated at the surface of the avalanche layer, and there are no fluctuations in the depth of absorption. Experiments on an indirect conversion x-ray imaging system using avalanche multiplication in a layer of a-Se are also presented. The cascaded systems analysis shows that intrinsic noise of avalanche multiplication will not have any deleterious influence on detector performance at zero spatial frequency in x-ray imaging provided the product of conversion gain, coupling efficiency, and optical quantum efficiency are much greater than a factor of 2. The experimental results show that avalanche multiplication in a-Se behaves as an intrinsic noise free avalanche multiplication, in accordance with our theory. Provided good coupling efficiency and high optical quantum efficiency are maintained, avalanche multiplication in a-Se has the potential to increase the gain and make negligible contribution to the noise, thereby improving the performance of indirect FPDs in fluoroscopy.


Asunto(s)
Tracto Gastrointestinal/diagnóstico por imagen , Intensificación de Imagen Radiográfica/métodos , Selenio , Amplificadores Electrónicos , Análisis de Varianza , Fluoroscopía , Modelos Teóricos , Procesos Estocásticos
17.
Med Phys ; 34(12): 4609-11, 2007 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-18196788

RESUMEN

In recent years new digital x-ray radiographic and fluoroscopic systems based on large-area flat-panel technology have revolutionized our capability of producing x-ray images. However, such imagers are extraordinarily expensive and their rapid image acquisition capability is not required for many applications such as radiography. Here we report a novel approach to achieve a high-quality digital radiographic system at a cost which is only a small fraction of competitive digital technologies. The results demonstrate that our proposed x-ray light valve system has excellent spatial resolution and adequate sensitivity compared to existing technologies.


Asunto(s)
Ahorro de Costo , Intensificación de Imagen Radiográfica/instrumentación , Electrodos , Cristales Líquidos , Transductores , Rayos X
18.
Med Phys ; 34(8): 3358-73, 2007 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-17879799

RESUMEN

Blocking layers are used to reduce leakage current in amorphous selenium detectors. The effect of the thickness of the blocking layer on the presampling modulation transfer function (MTF) and on dark current was experimentally determined in prototype single-line CCD-based amorphous selenium (a-Se) x-ray detectors. The sampling pitch of the detectors evaluated was 25 microm and the blocking layer thicknesses varied from 1 to 51 microm. The blocking layers resided on the signal collection electrodes which, in this configuration, were used to collect electrons. The combined thickness of the blocking layer and a-Se bulk in each detector was approximately 200 microm. As expected, the dark current increased monotonically as the thickness of the blocking layer was decreased. It was found that if the blocking layer thickness was small compared to the sampling pitch, it caused a negligible reduction in MTF. However, the MTF was observed to decrease dramatically at spatial frequencies near the Nyquist frequency as the blocking layer thickness approached or exceeded the electrode sampling pitch. This observed reduction in MTF is shown to be consistent with predictions of an electrostatic model wherein the image charge from the a-Se is trapped at a characteristic depth within the blocking layer, generally near the interface between the blocking layer and the a-Se bulk.


Asunto(s)
Mamografía/instrumentación , Mamografía/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Selenio/química , Rayos X , Algoritmos , Aluminio/química , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Fantasmas de Imagen , Platino (Metal)/química , Radiometría , Planificación de la Radioterapia Asistida por Computador , Sensibilidad y Especificidad , Transductores
19.
Med Phys ; 33(11): 4258-70, 2006 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17153404

RESUMEN

Most electronic portal imaging devices (EPIDs) developed so far use a Cu plate/phosphor screen to absorb x rays and convert their energies into light, and the light image is then read out. The main problem with this approach is that the Cu plate/phosphor screen must be thin (approximately 2 mm thick) in order to obtain a high spatial resolution, resulting in a low x-ray absorption or low quantum efficiency for megavoltage x rays (typically 2-4%). In addition, the phosphor screen contains high atomic number (high-Z) materials, resulting in an over-response of the detector to low-energy x rays in dosimetric verification. In this paper, we propose a new approach that uses Cerenkov radiation to convert x-ray energy absorbed by the detector into light for portal imaging applications. With our approach, a thick (approximately 10-30 cm) energy conversion layer made of a low-Z dielectric medium, such as a large-area, thick fiber-optic taper consisting of a matrix of optical fibers aligned with the incident x rays, is used to replace the thin Cu plate/phosphor screen. The feasibility of this approach has been investigated using a single optical fiber embedded in a solid material. The spatial resolution expressed by the modulation transfer function (MTF) and the sensitivity of the detector at low doses (approximately one Linac pulse) have been measured. It is predicted that, using this approach, a detective quantum efficiency of an order of magnitude higher at zero frequency can be obtained while maintaining a reasonable MTF, as compared to current EPIDs.


Asunto(s)
Radiometría/instrumentación , Radiometría/métodos , Radioterapia Conformacional/instrumentación , Radioterapia Conformacional/métodos , Pantallas Intensificadoras de Rayos X , Diseño de Equipo , Análisis de Falla de Equipo , Estudios de Factibilidad , Dosificación Radioterapéutica , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
20.
Med Phys ; 33(5): 1499-509, 2006 May.
Artículo en Inglés | MEDLINE | ID: mdl-16752584

RESUMEN

Indirect flat panel imagers have been developed for digital radiography, fluoroscopy and mammography, and are now in clinical use. Screens made from columnar structured cesium iodide (CsI) scintillators doped with thallium have been used extensively in these detectors. The purpose of this article is to investigate the effect of screen optics, e.g., light escape efficiency versus depth, on gain fluctuation noise, expressed as the Swank factor. Our goal is to obtain results useful in optimizing screens for digital radiography systems. Experimental measurements from structured CsI samples were used to derive their screen optics properties, and the same methods can also be applied to powder screens. CsI screens, all of the same thickness but with different optical designs and manufacturing techniques, were obtained from Hamamatsu Photonics Corporation. The pulse height spectra (PHS) of the screens were measured at different x-ray energies. A theoretical model was developed for the light escape efficiency and a method for deriving light escape efficiency versus depth from experimental PHS measurements was implemented and applied to the CsI screens. The results showed that the light escape efficiency varies essentially linearly as a function of depth in the CsI samples, and that the magnitude of variation is relatively small, leading to a high Swank factor.


Asunto(s)
Artefactos , Óptica y Fotónica/instrumentación , Intensificación de Imagen Radiográfica/instrumentación , Interpretación de Imagen Radiográfica Asistida por Computador/instrumentación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Procesamiento de Señales Asistido por Computador/instrumentación , Pantallas Intensificadoras de Rayos X , Algoritmos , Análisis de Falla de Equipo , Teoría Cuántica , Intensificación de Imagen Radiográfica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS