RESUMEN
PURPOSE: To present a set of closed-form analytical equations to create a consistent eye model balance based on clinically measured input parameters in a single step. These models complement the existing iterative approaches in the literature. METHODS: Two different approaches are presented, both considering the cornea and lens as equivalent thin lenses. The first, called the Gaussian model, starts by defining the refractive error as the difference between the axial power (or dioptric distance) and the whole eye power, which can be expanded by filling in the formulas for each power. The resulting equation can be solved for either the refractive error, axial length, corneal power, lens power or the distance between the cornea and the lens as a function of the other four parameters. The second approach uses vergence calculations to provide alternative expressions, assuming that the refractive error is located at the corneal plane. Both models are explored for a biometric range typically found in adult human eyes. RESULTS: The Gaussian and vergence models each instantly balance the input data into a working eye model over the human physiological range and far beyond as demonstrated in various examples. The equations of the Gaussian model are more complicated, while the vergence model experiences more singularities, albeit in trivial or highly unlikely parameter combinations. CONCLUSIONS: The proposed equations form a flexible and robust platform to create eye models from clinical data. Possible applications lie in creating animal eye models or providing a generic reference for real biometric data and the relationships between the ocular dimensions.
Asunto(s)
Modelos Biológicos , Humanos , Córnea/diagnóstico por imagen , Córnea/fisiología , Refracción Ocular/fisiología , Cristalino/fisiología , Errores de Refracción/fisiopatología , Animales , Vertebrados/fisiología , Distribución Normal , Biometría/métodosRESUMEN
PURPOSE: To estimate the astigmatic power of the crystalline lens and the whole eye without phakometry using a set of linear equations and to provide estimates for the astigmatic powers of the crystalline lens surfaces. METHODS: Linear optics expresses astigmatic powers in the form of matrices and uses paraxial optics and a 4 × 4 ray transfer matrix to generalise Bennett's method comprehensively to include astigmatic elements. Once this is established, the method is expanded to estimate the contributions of the front and back lens surfaces. The method is illustrated using two examples. The first example is of an astigmatic model eye and compares the calculated results to the original powers. In the second example, the method is applied to the biometry of a real eye with large lenticular astigmatism. RESULTS: When the calculated powers for the astigmatic model eye were compared to the actual powers, the difference in the power of the eye was 0.03 0.13 0.04 T D (where T represents the matrix transpose) and for the crystalline lens, the difference was 0.08 0.29 0.08 T D (power vector format). A second example applies the method to a real eye, obtaining lenticular astigmatism of -5.84 × 175. CONCLUSIONS: The method provides an easy-to-code way of estimating the astigmatic powers of the crystalline lens and the eye.
Asunto(s)
Astigmatismo , Biometría , Cristalino , Refracción Ocular , Cristalino/fisiología , Humanos , Biometría/métodos , Astigmatismo/fisiopatología , Refracción Ocular/fisiología , Modelos BiológicosRESUMEN
PURPOSE: To present a paraxial method to estimate the influence of variations in ocular biometry on changes in refractive error (S) at a population level and apply this method to literature data. METHODS: Error propagation was applied to two methods of eye modelling, referred to as the simple method and the matrix method. The simple method defines S as the difference between the axial power and the whole-eye power, while the matrix method uses more accurate ray transfer matrices. These methods were applied to literature data, containing the mean ocular biometry data from the SyntEyes model, as well as populations of premature infants with or without retinopathy, full-term infants, school children and healthy and diabetic adults. RESULTS: Applying these equations to 1000 SyntEyes showed that changes in axial length provided the most important contribution to the variations in refractive error (57%-64%), followed by lens power/gradient index power (16%-31%) and the anterior corneal radius of curvature (10%-13%). All other components of the eye contributed <4%. For young children, the largest contributions were made by variations in axial length, lens and corneal power for the simple method (67%, 23% and 8%, respectively) and by variations in axial length, gradient lens power and anterior corneal curvature for the matrix method (55%, 21% and 14%, respectively). During myopisation, the influence of variations in axial length increased from 54.5% to 73.4%, while changes in corneal power decreased from 9.82% to 6.32%. Similarly, for the other data sets, the largest contribution was related to axial length. CONCLUSIONS: This analysis confirms that the changes in ocular refraction were mostly associated with variations in axial length, lens and corneal power. The relative contributions of the latter two varied, depending on the particular population.
Asunto(s)
Longitud Axial del Ojo , Biometría , Refracción Ocular , Errores de Refracción , Humanos , Errores de Refracción/fisiopatología , Errores de Refracción/diagnóstico , Biometría/métodos , Refracción Ocular/fisiología , Niño , Longitud Axial del Ojo/diagnóstico por imagen , Córnea/diagnóstico por imagen , Adulto , Lactante , Preescolar , Recién Nacido , Masculino , Femenino , AdolescenteRESUMEN
PURPOSE: The goal was to use SyntEyes modelling to estimate the allowable alignment error of wavefront-guided rigid contact lens corrections for a range of normal and keratoconic eye aberration structures to keep objectively measured visual image quality at or above average levels of well-corrected normal eyes. Secondary purposes included determining the required radial order of correction, whether increased radial order of the corrections further constrained the allowable alignment error and how alignment constraints vary with keratoconus severity. METHODS: Building on previous work, 20 normal SyntEyes and 20 keratoconic SyntEyes were fitted with optimised wavefront-guided rigid contact lens corrections targeting between three and eight radial orders that drove visual image quality, as measured objectively by the visual Strehl ratio, to near 1 (best possible) over a 5-mm pupil for the aligned position. The resulting wavefront-guided contact lens was then allowed to translate up to ±1 mm in the x- and y-directions and rotate up ±15°. RESULTS: Allowable alignment error changed as a function of the magnitude of aberration structure to be corrected, which depends on keratoconus severity. This alignment error varied only slightly with the radial order of correction above the fourth radial order. To return the keratoconic SyntEyes to average levels of visual image quality depended on maximum anterior corneal curvature (Kmax). Acceptable tolerances for misalignment that returned keratoconic visual image quality to average normal levels varied between 0.29 and 0.63 mm for translation and approximately ±6.5° for rotation, depending on the magnitude of the aberration structure being corrected. CONCLUSIONS: Allowable alignment errors vary as a function of the aberration structure being corrected, the desired goal for visual image quality and as a function of keratoconus severity.
Asunto(s)
Lentes de Contacto , Topografía de la Córnea , Queratocono , Agudeza Visual , Humanos , Queratocono/fisiopatología , Queratocono/diagnóstico , Topografía de la Córnea/métodos , Adulto , Femenino , Masculino , Agudeza Visual/fisiología , Adulto Joven , Aberración de Frente de Onda Corneal/fisiopatología , Aberración de Frente de Onda Corneal/diagnóstico , Refracción Ocular/fisiología , Córnea/diagnóstico por imagen , Córnea/fisiopatologíaRESUMEN
PURPOSE: To analyse ocular coherence tomography (OCT) images of the retinal shadows caused by defocus and diffusion optics spectacles. METHODS: One eye was fitted successively with the Hoya Defocus Incorporated Multiple Segments (DIMS) spectacle lens, two variations of the +3.50 D peripheral add spectacle (DEFOCUS) and the low-contrast dot lens (Diffusion Optics Multiple Segments, DOMS); each at a vertex distance of 12 mm. Simultaneously, a retinal image of the macular region with central fixation was obtained using infrared OCT. The corneal power and intraocular distances were determined using an optical biometer. RESULTS: The retinal images for the DIMS and DOMS lenses showed patterns of obvious retinal shadows in the periphery, while the central 10-11° remained clear. The DEFOCUS lens produced a darkened peripheral area. Dividing the size of the retinal pattern, measured with the calliper of the OCT software, by the actual size on the spectacle lens gave a magnification of -0.57 times. This is consistent with the incoming OCT beam being imaged to a position approximately 31 mm beyond the front of the eye. [Correction added on 26 October 2023 after first online publication: The preceding paragraph was corrected.] CONCLUSION: With device-specific correction, retinal OCT images can help visualise the regions affected by the defocus or lowered contrast induced by myopia control spectacles. This is of potential value for improving myopia therapies.
Asunto(s)
Cristalino , Miopía , Humanos , Refracción Ocular , Anteojos , Miopía/terapia , Retina/diagnóstico por imagenRESUMEN
PURPOSE: There is currently no consensus on which keratoconus need cross-linking nor on how to establish progression. This study assessed the performance of diverse progression criteria and compared them with our clinical knowledge of keratoconus evolution. METHODS: This was a retrospective, longitudinal, observational study. Habitual progression criteria, based on (combinations of) keratometry (K MAX ), front astigmatism (A F ), pachymetry (P MIN ), or ABCD progression display, from 906 keratoconus patients were analyzed. For each criterion and cutoff, we calculated %eyes flagged progressive at some point (R PROG ), individual consistency C IND (%examinations after progression detection still considered progressive), and population consistency C POP (% eyes with CIND >66%). Finally, other monotonic and consistent variables, such as front steep keratometry (K 2F ), mean radius of the back surface (R mB ), and the like, were evaluated for the overall sample and subgroups. RESULTS: Using a single criterion (e.g., ∆K MAX >1D) led to high values of R PROG . When combining two, (K MAX and A F ) led to worse C POP and higher variability than (K MAX and P MIN ); alternative criteria such as (K 2F and R mB ) obtained the best C POP and the lowest variability ( P <0.0001). ABC, as defined by its authors, obtained R PROG of 74.2%. Using wider 95% confidence intervals (95% CIs) and requiring two parameters over 95CI reduced R PROG to 27.9%. CONCLUSION: Previous clinical studies suggest that 20% to 30% of keratoconus cases are progressive. This clinical R PROG value should be considered when defining KC progression to avoid overtreatment. Using combinations of variables or wider margins for ABC brings R PROG closer to these clinical observations while obtaining better population consistency than current definitions.
Asunto(s)
Queratocono , Fotoquimioterapia , Humanos , Queratocono/diagnóstico , Queratocono/tratamiento farmacológico , Fármacos Fotosensibilizantes/uso terapéutico , Refracción Ocular , Agudeza Visual , Estudios Retrospectivos , Rayos Ultravioleta , Riboflavina/uso terapéutico , Topografía de la Córnea , Reactivos de Enlaces Cruzados/uso terapéutico , Colágeno/uso terapéuticoRESUMEN
It was recently established that the axial power, the refractive power required by the eye for a sharp retinal image in an eye of a certain axial length, and the total refractive power of the eye may both be described by a bi-exponential function as a function of age (Rozema, 2023). Inspired by this result, this work explores whether these bi-exponential functions are able to simulate the various known courses of refractive development described in the literature, such as instant emmetropization, persistent hypermetropia, developing hypermetropia, myopia, instant homeostasis, modulated development, or emmetropizing hypermetropes. Moreover, the equations can be adjusted to match the refractive development of school-age myopia and pseudophakia up to the age of 20 years. All of these courses closely resemble those reported in the previous literature while simultaneously providing estimates for the underlying changes in axial and whole eye power.
Asunto(s)
Emetropía , Hiperopía , Miopía , Refracción Ocular , Humanos , Refracción Ocular/fisiología , Miopía/fisiopatología , Niño , Adolescente , Hiperopía/fisiopatología , Adulto Joven , Emetropía/fisiología , Preescolar , Longitud Axial del Ojo , Seudofaquia/fisiopatología , Adulto , Ojo/crecimiento & desarrollo , Envejecimiento/fisiología , Errores de Refracción/fisiopatologíaRESUMEN
PURPOSE: Although there are many reports on ocular growth, these data are often fragmented into separate parameters or for limited age ranges. This work intends to create an overview of normal eye growth (i.e., in absence of myopisation) for the period before birth until 18 years of age. METHODS: The data for this analysis were taken from a search of six literature databases using keywords such as "[Parameter] & [age group]", with [Parameter] the ocular parameter under study and [age group] an indication of age. This yielded 34,409 references that, after screening of title, abstract and text, left 294 references with usable data. Where possible, additional parameters were calculated, such as the Bennett crystalline lens power, whole eye power and axial power. RESULTS: There were 3422 average values for 17 parameters, calculated over a combined total of 679,398 individually measured or calculated values. The age-related change in refractive error was best fitted by a sum of four exponentials (r2 = 0.58), while all other biometric parameters could be fitted well by a sum of two exponentials and a linear term ('bi-exponential function'; r2 range: 0.64-0.99). The first exponential of the bi-exponential fits typically reached 95% of its end value before 18 months, suggesting that these reached genetically pre-programmed passive growth. The second exponentials reached this point between 4 years of age for the anterior curvature and well past adulthood for most lenticular dimensions, suggesting that this part represents the active control underlying emmetropisation. The ocular components each have different growth rates, but growth rate changes occur simultaneously at first and then act independently after birth. CONCLUSIONS: Most biometric parameters grow according to a bi-exponential pattern associated with passive and actively modulated eye growth. This may form an interesting reference to understand myopisation.
Asunto(s)
Cristalino , Errores de Refracción , Adulto , Humanos , Biometría/métodos , Córnea , Refracción OcularRESUMEN
PURPOSE: To give an overview of the misconceptions and potential artefacts associated with measuring peripheral refractive error and eye length, the use of these measures to determine the retinal shape and their links to myopia development. Several issues were identified: the relationship between peripheral refractive error and myopia development, inferring the retinal shape from peripheral refraction or eye length patterns, artefacts and accuracy when measuring peripheral eye length using an optical biometer. METHODS: A theory was developed to investigate the influence of artefacts in measuring peripheral eye length and on using peripheral eye length to make inferences about retinal shape. RESULTS: When determining peripheral axial length, disregarding the need to realign instruments with mounted targets can lead to incorrect field angles and positions of mounted targets by more than 10% for targets placed close to the eye. Peripheral eye length is not a good indicator of the effects of myopia or of treatment for myopia development because eyes of different lengths but with the same retinal shape would be interpreted as having different retinal shapes; the measurement leads to overestimates of changes in retinal curvature as myopia increases. Determining peripheral eye length as a function of estimated retinal height rather than field angle will halve the magnitude of the artefact. The artefact resulting from the peripheral use of biometers with an on-axis calibration is modest and can be ignored. CONCLUSION: There are significant issues with peripheral measurements of the refractive error and eye length that must be considered when interpreting these data for myopia research. Some of these issues can be mitigated, while others require further investigation.
Asunto(s)
Miopía , Errores de Refracción , Humanos , Ojo , Refracción Ocular , Retina/diagnóstico por imagen , Pruebas de Visión , Longitud Axial del OjoRESUMEN
PURPOSE: To investigate whether Pentacam densitometry readings are affected by corneal tilt. METHODS: In a prospective study, the right eyes of 86 healthy participants aged 42.8 ± 20.0 years (range 18-79 years) were imaged using Scheimpflug tomography. Elevation maps were exported to calculate corneal tilt using custom-made software, and densitometry readings were acquired directly from the corneal densitometry analysis add-on to the standard software Oculus Pentacam HR. Simple mediation analysis was applied to study age as a confounding factor in the correlation between corneal tilt and corneal densitometry. RESULTS: Corneal tilt and corneal densitometry are not independent from one another because age is significantly correlated with both corneal tilt (r = 0.50, p < 0.001) and corneal densitometry (r = 0.91, p < 0.001). Only 3.8% of the correlation between tilt and densitometry operates directly, while the remaining 96.2% depends on age. CONCLUSIONS: Corneal tilt plays a role in corneal densitometry readings, even though the interaction is strongly influenced by age. Age is a well-known factor in densitometry readings that should be taken into consideration when interpreting Scheimpflug densitometry.
Asunto(s)
Córnea , Topografía de la Córnea/métodos , Densitometría/métodos , Voluntarios Sanos , Humanos , Estudios ProspectivosRESUMEN
PURPOSE: To expand the SyntEyes keratoconus (KTC) model to assess the Visual Image Quality (VIQ) of sphero-cylindrical spectacle and rigid contact lens corrections as keratoconus progresses. METHODS: The previously published SyntEyes KTC eye model to determine best sphero-cylindrical spectacle and rigid contact lens correction in keratoconic eyes was expanded to include the natural progression of keratoconus, thus allowing the assessment of corrected VIQ with disease progression. RESULTS: As keratoconus progresses, the pattern of visual Strehl ratio (VSX) in correction space for spectacles alters from a typical hourglass into a shell pattern. The former would guide the subjective refraction towards the optimal correction while the latter is relatively insensitive to large dioptric steps. In 15 out of the 20 SyntEyes, the shell pattern eventually produces two foci on different sides of the correction space separated by a clinically significant dioptric difference with a similar, albeit lower VIQ. Wearing the best possible spectacle corrections provided an average gain of up to 3.5 lines of logMAR visual acuity compared to the uncorrected cases, which increased to 5.5 lines for the best rigid contact lens correction. Continuing to wear a spectacle correction as the disease progresses often leads to a VIQ that is almost as bad as the uncorrected case. Continuing to wear a rigid contact lens correction as the disease progresses maintains a relatively high level of VIQ, albeit in the low range for typically well-corrected normal eyes. CONCLUSIONS: The results reflect the clinical experience that subjective refraction is difficult in highly-aberrated keratoconic eyes, the benefit of spectacle correction is short lived and that rigid contact lenses provide better and more stable VIQ with disease progression. Other aspects, such as the presence and behaviour of the second focus in some cases, remain to be confirmed clinically.
Asunto(s)
Lentes de Contacto , Queratocono , Anteojos , Humanos , Queratocono/diagnóstico , Queratocono/terapia , Refracción Ocular , Agudeza VisualRESUMEN
PURPOSE: To investigate whether the movement of a rigid sphero-cylindrical contact lens has a greater impact on the visual image quality in highly aberrated eyes than in normal eyes. METHODS: For 20 normal and 20 keratoconic SyntEyes, a previously determined best sphero-cylindrical rigid lens was permitted to shift by up to ±1 mm from the line of sight and rotate up to ±15°. Each of the 52,111 lens locations sampled was ray-traced to determine the influence on the wavefront aberration. In turn, the logarithm of visual Strehl ratio (log10 [VSX]) was calculated for each aberration structure and was used to estimate the associated changes in logMAR visual acuity. Finally, contour surfaces of two-letter change in visual acuity were plotted in three-dimensional misalignment space, consisting of decentrations in the x and y directions and rotation, and volumes within these surfaces were calculated. RESULTS: The variations in image quality within the misalignment space were unique to each eye. A two-letter loss was generally reached with smaller misalignments in keratoconic eyes (10.5 ± 4.7° of rotation or 0.27 ± 0.13 mm of shift) than in normal eyes (13.4 ± 1.8° and 0.39 ± 0.15 mm, respectively) due to larger cylindrical errors. For keratoconic eyes, on average, 14.4 ± 14.9% of misalignment space saw VSX values above the lower normal VSX threshold, well below the values of normal eyes of 48.5 ± 18.5%. In some eyes, a specific combination of lens shift and lens rotation away from the line of sight leads to a simulated improvement in visual image quality. CONCLUSION: Variations in visual image quality due to the misalignment of rigid sphero-cylindrical contact lens corrections are larger for keratoconic eyes than for normal eyes. In some cases, a specific misalignment may improve visual image quality, which could be considered in the design of the next generation of rigid contact lenses.
Asunto(s)
Lentes de Contacto , Queratocono , Ojo , Humanos , Queratocono/diagnóstico , Queratocono/terapia , Rotación , Agudeza VisualRESUMEN
OBJECTIVE: To evaluate the effect of specialty contact lens (CL) wear on posterior corneal tomography in keratoconus subjects. METHODS: Patients with keratoconus who were wearing specialty CL were included in this retrospective cohort study. Tomographic parameters were evaluated with Scheimpflug imaging (Pentacam HR) before lens fitting and immediately after removal of CLs worn habitually for a period of several months. Subjects were divided into groups, according to type of lens (corneal, scleral, and hybrid) and keratoconus severity based on Belin/Ambrosio D (BAD-D) score, for further analysis. RESULTS: Thirty-four eyes of 34 subjects diagnosed with keratoconus were included. Mean duration of habitual CL wear was 7.0±0.3 months. For the entire cohort, a small increase in flat keratometric reading at the anterior corneal surface (K1F; P =0.032) and at the posterior surface (K1B; P =0.041) was found. In the corneal CL group (10 eyes; 29.4%), flattening of the anterior corneal curvature was detected (K max ; P =0.015). An increase in K1B value was seen in the scleral CL group (15 eyes; 44.1%) ( P =0.03). Combined topometric indices showed a small but significant difference in the entire cohort ( P <0.05) and in the subgroups of corneal CL wear and of moderate keratoconus (BAD-D score≥7). CONCLUSION: Various types of specialty CLs exert a differential influence on corneal parameters. A small steepening of keratometry at the posterior surface (K1B) was observed in the scleral lens group. Although corneal lens wear flattens the anterior cornea (K max ), it does not significantly alter the posterior corneal surface.
Asunto(s)
Lentes de Contacto , Queratocono , Humanos , Queratocono/diagnóstico , Queratocono/terapia , Topografía de la Córnea/métodos , Estudios Retrospectivos , Córnea/diagnóstico por imagen , Tomografía Computarizada por Rayos XRESUMEN
PURPOSE: To develop an age-dependent model to estimate the positions of the ocular and lenticular principal planes (pps) for use in ocular and axial power calculations. METHODS: Ocular power of the eye (Peye ) and axial power (Pax ) were calculated based on previously published average data of the ocular biometry and refraction in newborn infants, children and adults, as well as the associated pp positions. Next, regressions of the pp positions were made as a function of the logarithm of age, which were subsequently used to estimate Peye and Pax . These regression-based estimates were compared with the original data for validation. Finally, this procedure was repeated using the Atchison myopic eye model to determine the influence of myopia on the regression estimates. RESULTS: In adults, the corneal pps almost coincide at 0.058 mm in front of the cornea. The first lenticular pp position relative to the corneal apex is described by the equation: 5.809 - 0.697·exp(-0.211·Age) (r2 = 0.96), and the second lenticular pp by 6.026 - 0.684·exp(-0.232·Age) (r2 = 0.95). The first ocular pp position relative to the corneal apex is at 0.293·exp(-0.232·Age) - 2.2·10-3 ·Age + 1.723 (r2 = 0.99) and the second ocular pp is located at 0.392·exp(-0.181·Age) - 2.4·10-3 ·Age + 2.093 (r2 = 0.99). Estimates of Peye and Pax derived from these regressions led to minor differences from the original values (0.00 ± 0.06D and 0.00 ± 0.10D, respectively). These errors were not affected by ocular refraction between -10D and 0D, with errors of + 0.12 ± 0.00D and -0.02 ± 0.05D for Peye and Pax , respectively. CONCLUSION: The proposed regression models of the pp positions are sufficiently accurate to estimate Peye and Pax reliably. Interestingly, although the adult lens undergoes considerable physiological changes, its pps remain fixed with respect to the corneal apex.
Asunto(s)
Biometría/métodos , Córnea/fisiopatología , Cristalino/fisiopatología , Miopía/fisiopatología , Refracción Ocular/fisiología , Adolescente , Adulto , Niño , Preescolar , Femenino , Humanos , Lactante , Recién Nacido , Lentes Intraoculares , Masculino , Adulto JovenRESUMEN
PURPOSE: Approaches are developed to determine relative retinal magnifications in anisometropic patients undergoing cataract surgery; these can be used to balance between full spectacle corrections with equal intraocular lens (IOL) powers and a pure IOL power correction. METHODS: The analysis started from the original and pseudophakic Navarro eye models, where in the latter case an IOL replaced the natural lens. A third model was a simplified Navarro-IOL model with a single surface cornea and a thin lens. These models were manipulated by altering vitreous length, corneal power and lens position. Retinal image sizes were determined for both full IOL corrections and full spectacle corrections by raytracing and approximate equations. Relative magnification (RM) was determined as the ratio of retinal image size of an eye to that of the appropriate standard eye. RESULTS: For raytracing and full IOL correction, vitreous length led to RM change of 5%/mm, while for corneal power and IOL position this was -0.4%/D and 1.4%/mm, respectively. For raytracing and spectacle correction, effects were 0%/D (vitreous depth), -1.6%/D (corneal power) and +1.0%/mm (IOL position). For full IOL correction, the approximate RM calculations were highly accurate. For spectacle correction, the approximate RM calculations were exact for vitreous length changes, reasonably accurate for corneal power changes but very inaccurate for changes in anterior chamber depth. CONCLUSION: Relative magnification approximations may be useful to assess the risk of aniseikonia in anisometropic patients targeted for postoperative emmetropia. Some of these patients would be corrected best by a combination of spectacles and IOLs.
Asunto(s)
Extracción de Catarata , Lentes Intraoculares , Córnea , Anteojos , Humanos , SeudofaquiaRESUMEN
PURPOSE: To present a descriptive system for the elliptic demarcation area seen in keratoconus densitometry maps (obtained with a Scheimpflug tomographer) and to evaluate its suitability for clinical practice. METHODS: The subjects were 30 keratoconus patients at different stages and 20 healthy subjects. The averaged densitometry maps ('two-layers' scan, with fixed layers 120 µm and endothelium) were analysed using a system of four categories (termed 'Brightness', 'Contrast', 'Decentration' and 'Octants surrounded by a dark line') that we created to characterise the demarcation area. Four examiners (three corneal specialists and one junior resident) used the system to classify the maps. The inter-rater agreement was calculated for two subgroups: (1) clinical keratoconus patients and (2) both healthy patients and forme fruste keratoconus patients. Intra-rater agreement was also determined. RESULTS: Inter-rater agreement on classification was higher when analysing clinical keratoconus, reaching levels of substantial agreement. Despite this, only low levels of agreement were found in 'Decentration', penalized due to the skewness in the distribution of this descriptor. Almost perfect intra-rater agreement was obtained for all descriptors in the first subgroup of clinical keratoconus, whereas the agreement was generally moderate within the second subgroup of normal and forme fruste eyes. Agreement was slightly lower with the less experienced observer. At least three observers agreed on four forme fruste keratoconus eyes presenting abnormalities in the images. The observers reported that the 'Brightness' descriptor was subjective and redundant with 'Contrast'. CONCLUSIONS: The description of the area was repeatable and reproducible, and may be a valuable supplement when documenting clinical keratoconus stage and progression in daily practice. However, a minor learning curve was noticed and agreement was higher among the more experienced observers. Since the descriptor 'Brightness' was found to be subjective and redundant, it was excluded from the final proposed classification.
Asunto(s)
Queratocono , Córnea , Topografía de la Córnea , Densitometría , Humanos , Queratocono/diagnóstico , Reproducibilidad de los ResultadosRESUMEN
PURPOSE: This study was developed to explain the extraordinary rise in myopia prevalence beginning after 1950 in Indigenous Arctic communities considering recent findings about the risk factors for school myopia development. Myopia prevalence changed drastically from a historical low of less than 3% to more than 50% in new generations of young adults following the Second World War. At that time, this increase was attributed to concurrent alterations in the environment and way of life which occurred in an aggressive programme of de-culturalization and re-acculturation through residential school programmes that introduced mental, emotional and physical stressors. However, the predominant idea that myopia was genetic in nature won the discussion of the day, and research in the area of environmental changes was dismissed. There may have also been an association between myopia progression and the introduction of extreme mental, emotional and physical stressors at the time. RECENT FINDINGS: Since 1978, animal models of myopia have demonstrated that myopiagenesis has a strong environmental component. Furthermore, multiple studies in human populations have shown since 2005 how myopia could be produced by a combination of limited exposure to the outdoors and heavy emphasis on academic subjects associated with intense reading habits. This new knowledge was applied in the present study to unravel the causes of the historical myopia epidemics in Inuit communities. SUMMARY: After reviewing the available published data on myopia prevalence in circumpolar Inuit populations in the 20th century, the most likely causes for the Inuit myopia epidemic were the combination of increased near work (from almost none to daily reading) and the move from a mostly outdoor to a much more indoor way of life, exacerbated by fewer hours of sunshine during waking hours, the lower illuminance in the Arctic and the extreme psychophysical stress due to the conditions in the Residential Schools.
Asunto(s)
Epidemias , Miopía , Humanos , Miopía/epidemiología , Prevalencia , Factores de Riesgo , Instituciones AcadémicasRESUMEN
OBJECTIVES: To identify the most suitable parameters to describe keratoconus progression. METHODS: Longitudinal retrospective cohort study. Monotonicity and consistency of over 250 parameters extracted from the Pentacam tomographies (Oculus, Germany) of 743 patients was analyzed. Repeatability was calculated for 69 patients (published elsewhere). The parameters were scored based on their performance for each desired feature and a global ranking was created. RESULTS: Overall, parameters that average a higher number of corneal points performed better than single-point parameters. Zonal keratometries on areas surrounding the maximum curvature point and the steepest front keratometry performed best, followed by front best-fit sphere and mean keratometry of both surfaces. Platform-dependent indices (e.g., Belin-Ambrósio Deviation- or index height decentration-) obtained good scores, but platform-independent LOGIK performed slightly better. Finally, although minimum radius in both surfaces worked competently, minimum pachymetry (PachyMin) performed considerably poorer. CONCLUSIONS: We presented a list of parameters whose behavior was repeatable, monotonic and consistent, features desirable to describe change. The parameters normally used to follow keratoconus progression may not be the most adequate, as evidenced by the poor performance of PachyMin. Although calculated for a specific Scheimpflug device, most of the best-performing parameters are platform-independent variables, and results may be generalized, pending validation.
Asunto(s)
Queratocono , Computadores , Córnea/diagnóstico por imagen , Paquimetría Corneal , Topografía de la Córnea , Humanos , Queratocono/diagnóstico por imagen , Curva ROC , Estudios Retrospectivos , TomografíaRESUMEN
This work intends to determine the optimal refractive spectacle and scleral lens corrections for keratoconus patients using the visual Strehl (VSX) visual image quality metric and the SyntEyes models with the synthetic biometry of 20 normal eyes and 20 keratoconic eyes. These included the corneal tomography and intraocular biometry. A series of virtual spherocylindrical spectacle and scleral lens corrections spanning the entire phoropter range were separately applied to each eye, followed by ray tracing to determine the residual wavefront aberrations and identify the correction with the highest possible VSX (named a "focus"). To speed up calculations, a smart scanning algorithm was used, consisting of three consecutive scans over increasingly finer dioptric grids. In the dioptric space, the VSX pattern for normal eyes considered over the correction range for either spectacle or scleral lens corrections resembled an hourglass with one distinct focus and a quick drop in VSX away from that focus. For 18 of the 20 keratoconic eyes, the spectacle-corrected VSX pattern resembled a shell that in 9 of the 20 cases showed two foci separated by a large dioptric distance (13.3 ± 4.9 diopters). In keratoconic eyes, scleral lenses also produced hourglass patterns, but with a VSX lower than in normal eyes. The hourglass pattern in dioptric space shows how, in normal eyes, the refracting process automatically funnels practitioners toward the optimal correction. The shell patterns in keratoconus, however, present far more complexity and, possibly, multiple foci. Depending on the starting point, refracting procedures may lead to a local maximum rather than the optimal correction.
Asunto(s)
Queratocono , Córnea/diagnóstico por imagen , Humanos , Queratocono/diagnóstico por imagen , Queratocono/terapia , Refracción Ocular , Esclerótica , Agudeza VisualRESUMEN
PURPOSE: To investigate the origins of age-related decreases in axial length in the literature. METHODS: A literature review was performed, including all articles regarding axial length changes with age. These data were combined with mean body length and education level for the countries of each study to assess their influence in a multivariate analysis. Furthermore, analyses were performed of how optical path length, used by optical biometers to measure axial length, is affected by the known age-related changes in the crystalline lens. The influence of other factors mentioned in the literature was also investigated. RESULTS: Seventeen cross-sectional studies were found that met the search criteria. The decrease in axial length over time was consistent across most of these studies. However, when plotted as a function of year of birth, mean body length and number of years in school, the data indicated an increase in length. Multivariate analysis confirmed the influence of body length (P = 0.005) and birth year (P = 0.017), but not age (P = 0.50). Meanwhile, the lenticular changes due to aging and cataract formation cause a minor bias in the form of increased axial length measurements. Finally, a gradual thinning of the choroidal arteries was reported to cause an increase in axial length. CONCLUSION: The age-related decrease in axial length is mainly associated with gradual changes in increased body length and education level, while attenuated by minor biases in measurement procedure and thinning of the choroidal arteries.