Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Sensors (Basel) ; 23(8)2023 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-37112431

RESUMEN

Surface crack detection and sizing is essential for the manufacturing and maintenance of engines, run parts, and other metal elements of aircrafts. Among various non-destructive detection methods, the fully non-contact and non-intrusive technique based on laser-stimulated lock-in thermography (LLT) has recently attracted a lot of attention from the aerospace industry. We propose and demonstrate a system of reconfigurable LLT for three-dimensional surface crack detection in metal alloys. For large area inspection, the multi-spot LLT can speed up the inspection time by a factor of the number of spots. The minimum resolved size of micro-holes is ~50 µm in diameter limited by the magnification of the camera lens. We also study the crack length ranging from 0.8 to 3.4 mm by varying the modulation frequency of LLT. An empirical parameter related to the thermal diffusion length is found to show the linear dependence with the crack length. With the proper calibration, this parameter can be used to predict the sizing of the surface fatigue cracks. Reconfigurable LLT allows us to quickly locate the crack position and accurately measure its dimensions. This method is also applicable to the non-destructive detection of surface or sub-surface defect in other materials used in various industries.

2.
Indoor Air ; 31(5): 1639-1644, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33876847

RESUMEN

Facing shortages of personal protective equipment, some clinicians have advocated the use of barrier enclosures (typically mounted over the head, with and without suction) to contain aerosol emissions from coronavirus disease 2019 (COVID-19) patients. There is, however, little evidence for its usefulness. To test the effectiveness of such a device, we built a manikin that can expire micron-sized aerosols at flow rates close to physiological conditions. We then placed the manikin inside the enclosure and used a laser sheet to visualize the aerosol leaking out. We show that with sufficient suction, it is possible to effectively contain aerosol from the manikin, reducing aerosol exposure outside the enclosure by 99%. In contrast, a passive barrier without suction only reduces aerosol exposure by 60%.


Asunto(s)
Contaminación del Aire Interior/prevención & control , COVID-19/epidemiología , COVID-19/prevención & control , Control de Infecciones/métodos , Humanos , Modelos Anatómicos , SARS-CoV-2 , Succión/métodos
3.
Small ; 8(3): 423-31, 2012 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-22162356

RESUMEN

Inspired by the amphiphilicity of graphene oxide (GO), the surface of water is used as a template for the assembly of a GO film. Methacrylate-functionalized GO sheets can be cross-linked instantaneously at the water-air interface to form a highly wrinkled membrane spreading over an extended area. The multiple covalent linkages amongst the GO sheets enhances the in-plane stiffness of the film compared to noncovalently bonded GO films. The highly convoluted GO membrane can be used in two applications: the promoting of spontaneous stem-cell differentiation towards bone cell lineage without any chemical inducers, and for supercapacitor electrodes. Due to reduced van der Waals restacking, capacitance values up to 211 F g(-1) can be obtained. The scalable and inexpensive nature of this assembly route enables the engineering of membranes for applications in regenerative medicine and energy-storage devices where secondary structures like nanotopography and porosity are important performance enhancers.

4.
Langmuir ; 27(13): 8430-6, 2011 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-21639401

RESUMEN

The layer-by-layer assembly of poly(diallyldimethylammonium chloride) and poly(sodium 4-styrenesulfonate) is studied on templates with imprinted arrays of microwells ranging from 2 to 25 µm and different aspect ratios. The thickness and microstructure of polyelectrolyte multilayers (PEMs) are measured using scanning electron microscopy. At 0.2 M ionic strength, the PEM film evenly coats the template both inside and outside the microwells. If the film is thinner than the critical value of about 400 nm, PEM microstructures collapse upon dissolving the template. Euler's model of critical stress is used to describe the collapse. At 2 M ionic strength, a substantially thinner PEM film is assembled inside the 25 µm wells than outside. If the well diameter is reduced to 7 and 2 µm, a much thicker PEM film is formed inside the microwells. These observations have been attributed to the changing of polyelectrolyte conformation in the solutions.


Asunto(s)
Polietilenos/síntesis química , Poliestirenos/síntesis química , Compuestos de Amonio Cuaternario/síntesis química , Electrólitos/síntesis química , Electrólitos/química , Tamaño de la Partícula , Polietilenos/química , Poliestirenos/química , Compuestos de Amonio Cuaternario/química , Propiedades de Superficie
5.
Phys Chem Chem Phys ; 13(9): 4005-12, 2011 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-21240391

RESUMEN

The original theoretical model of polyelectrolyte adsorption onto water-dispersed colloid particles is extended to the system of polydisperse droplets of sunflower oil. Polycation (poly(allylamine hydrochloride)) and polyanion (poly(sodium 4-styrenesulfonate)) are taken in the theoretically projected concentrations to perform Layer-by-Layer assembly of a multilayer shell on the surface of oil droplets preliminary stabilized with a protein emulsifier (bovine serum albumin). The velocity of gravitational separation in suspension of encapsulated oil droplets is theoretically predicted and experimentally measured depending on the coating shell's thickness, aiming to clarify the mechanism to control over the separation process. Combining the theory and experimental data, the mass density of a polyelectrolyte multilayer shell assembled in a Layer-by-Layer fashion is obtained. Polyelectrolyte multilayer coated oil droplets are characterized by means of ζ-potential, and particle size measurements, and visualized by scanning electron microscopy.


Asunto(s)
Cápsulas/química , Aceites/química , Poliaminas/química , Polímeros/química , Ácidos Sulfónicos/química , Agua/química , Animales , Bovinos , Cinética , Modelos Teóricos , Albúmina Sérica Bovina/química
6.
OTO Open ; 5(2): 2473974X211010408, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33948529

RESUMEN

OBJECTIVES: There is a lack of evidence-based guidelines with regard to eye protection for aerosol-generating procedures in otolaryngology practice. In addition, some recommended personal protective equipment (PPE) is not compatible with commonly used ENT equipment. This study aims to investigate the degree of eye protection that commonly used PPE gives. STUDY DESIGN: Simulation model. SETTING: Simulation laboratory. METHODS: A custom-built setup was utilized to simulate the clinical scenario of a patient cough in proximity of a health care worker. A system that sprays a xanthan-fluorescein mixture was set up and calibrated to simulate a human cough. A mannequin with cellulose paper placed on its forehead, eyes, and mouth was fitted with various PPE combinations and exposed to the simulated cough. The degree of contamination on the cellulose papers was quantified with a fluorescent microscope able to detect aerosols ≥10 µm. RESULTS: When no eye protection was worn, 278 droplets/aerosols reached the eye area. The use of the surgical mask with an attached upward-facing shield alone resulted in only 2 droplets/aerosols reaching the eye area. In this experiment, safety glasses and goggles performed equally, as the addition of either brought the number of droplets/aerosols reaching the eye down to 0. CONCLUSION: When used with an upward-facing face shield, there was no difference in the eye protection rendered by safety goggles or glasses in this study. Safety glasses may be considered a viable alternative to safety goggles in aerosol-generating procedures.

7.
Research (Wash D C) ; 2021: 2173642, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33655212

RESUMEN

Small-sized droplets/aerosol transmission is one of the factors responsible for the spread of COVID-19, in addition to large droplets and surface contamination (fomites). While large droplets and surface contamination can be relatively easier to deal with (i.e., using mask and proper hygiene measures), aerosol presents a different challenge due to their ability to remain airborne for a long time. This calls for mitigation solutions that can rapidly eliminate the airborne aerosol. Pre-COVID-19, air ionizers have been touted as effective tools to eliminate small particulates. In this work, we sought to evaluate the efficacy of a novel plant-based ionizer in eliminating aerosol. It was found that factors such as the ion concentration, humidity, and ventilation can drastically affect the efficacy of aerosol removal. The aerosol removal rate was quantified in terms of ACH (air changes per hour) and CADR- (clean air delivery rate-) equivalent unit, with ACH as high as 12 and CADR as high as 141 ft3/minute being achieved by a plant-based ionizer in a small isolated room. This work provides an important and timely guidance on the effective deployment of ionizers in minimizing the risk of COVID-19 spread via airborne aerosol, especially in a poorly-ventilated environment.

8.
Head Neck ; 42(10): 2779-2781, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32621399

RESUMEN

Respiratory particle generation and dispersal during nasoendoscopy and swab testing is studied with high-speed video and laser light illumination. Video analysis reveals droplet formation in three manoeuvres during nasoendoscopy - sneezing, vocalization, and nasal decongestion spray. A capillary bridge of mucus can be seen when a nasoendoscope exits wet nares. No droplet formation is seen during oral and nasopharyngeal swab testing. We outline the following recommendations: pull the face mask down partially and keep the mouth covered, only allowing nasal access during nasoendoscopy; avoid nasal sprays if possible; if nasal sprays are used, procedurists should be in full personal protective equipment prior to using the spray; withdrawal of swabs and scopes should be performed in a slow and controlled fashion to reduce potential dispersion of droplets when the capillary bridge of mucus breaks up.


Asunto(s)
Prueba de COVID-19 , Endoscopía , Moco , Cavidad Nasal , Fonación/fisiología , Estornudo/fisiología , Administración Intranasal , Humanos , Control de Infecciones , Transmisión de Enfermedad Infecciosa de Paciente a Profesional , Rociadores Nasales , Equipo de Protección Personal
9.
J Vis Exp ; (136)2018 06 17.
Artículo en Inglés | MEDLINE | ID: mdl-29985336

RESUMEN

The systemic administration of micro-size particles into a living organism can be applied for vasculature visualization, drug and vaccine delivery, implantation of transgenic cells and tiny optical sensors. However, intravenous microinjections into small animals, which are mostly used in biological and veterinary laboratories, are very difficult and require trained personnel. Herein, we demonstrate a robust and efficient method for the introduction of microparticles into the circulatory system of adult zebrafish (Danio rerio) by injection into the fish kidney. To visualize the introduced microparticles in the vasculature, we propose a simple intravital imaging technique in fish gills. In vivo monitoring of the zebrafish blood pH was accomplished using an injected microencapsulated fluorescent probe, SNARF-1, to demonstrate one of the possible applications of the described technique. This article provides a detailed description of the encapsulation of pH-sensitive dye and demonstrates the principles of the quick injection and visualization of the obtained microcapsules for in vivo recording of the fluorescent signal. The proposed method of injection is characterized by a low mortality rate (0-20%) and high efficiency (70-90% success), and it is easy to institute using commonly available equipment. All described procedures can be performed on other small fish species, such as guppies and medaka.


Asunto(s)
Micropartículas Derivadas de Células/metabolismo , Riñón/metabolismo , Animales , Riñón/citología , Pez Cebra
10.
Talanta ; 182: 187-192, 2018 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-29501139

RESUMEN

A new Membrane Film Sensor (MFS) has been developed to measure pH of fluids. MFS comprises a polyelectrolyte multilayer film with uniformly distributed compartments (microchambers) where a fluorescent sensing dye is encapsulated. Fabricated film is sealed onto a polyethylene film for a future use. MFS was applied to report changes in golden pomfret fillet upon its storage at 5 °C. MFS pH readings were correlated to bacteriological analysis of fish samples. A hike in pH of fish juices happens after 10 days of storage signaling bacterial spoilage of fish. The design of developed MFS allows easy integration with transparent packaging materials for future development of "SMART" packaging sensing food freshness.


Asunto(s)
Benzopiranos/química , Técnicas Biosensibles , Productos Pesqueros/análisis , Colorantes Fluorescentes/química , Embalaje de Alimentos/métodos , Naftoles/química , Rodaminas/química , Composición de Medicamentos/métodos , Productos Pesqueros/microbiología , Inocuidad de los Alimentos/métodos , Humanos , Concentración de Iones de Hidrógeno , Membranas Artificiales , Polielectrolitos/química , Polietileno/química , Polietilenos/química , Compuestos de Amonio Cuaternario/química
11.
PLoS One ; 12(10): e0186548, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29045437

RESUMEN

In vivo physiological measurement is a major challenge in modern science and technology, as is environment conservation at the global scale. Proper toxicological testing of widely produced mixtures of chemicals is a necessary step in the development of new products, allowing us to minimize the human impact on aquatic ecosystems. However, currently available bioassay-based techniques utilizing small aquatic organisms such as fish embryos for toxicity testing do not allow assessing in time the changes in physiological parameters in the same individual. In this study, we introduce microencapsulated fluorescent probes as a promising tool for in vivo monitoring of internal pH variation in zebrafish embryos. The pH alteration identified under stress conditions demonstrates the applicability of the microencapsulated fluorescent probes for the repeated analysis of the embryo's physiological state. The proposed approach has strong potential to simultaneously measure a range of physiological characteristics using a set of specific fluorescent probes and to finally bring toxicological bioassays and related research fields to a new level of effectiveness and sensitivity.


Asunto(s)
Composición de Medicamentos , Embrión no Mamífero/fisiología , Monitoreo del Ambiente/instrumentación , Monitoreo del Ambiente/métodos , Colorantes Fluorescentes/química , Sondas Moleculares/química , Pez Cebra/embriología , Animales , Biomarcadores/metabolismo , Calibración , Concentración de Iones de Hidrógeno
12.
Biol Open ; 6(5): 673-677, 2017 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-28507056

RESUMEN

Tracking physiological parameters in different organs within the same organism simultaneously and in real time can provide an outstanding representation of the organism's physiological status. The state-of-the-art technique of using encapsulated fluorescent molecular probes (microencapsulated biomarkers) is a unique tool that can serve as a platform for the development of new methods to obtain in vivo physiological measurements and is applicable to a broad range of organisms. Here, we describe a novel technique to monitor the pH of blood inside the gill capillaries and interstitial fluid of muscles by using microencapsulated biomarkers in a zebrafish model. The functionality of the proposed technique is shown by the identification of acidification under anesthesia-induced coma and after death. The pH in muscles reacts to hypoxia faster than that in the gill bloodstream, which makes both parameters applicable as markers of either local or bodily reactions.

13.
Lab Chip ; 15(1): 253-63, 2015 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-25360665

RESUMEN

We designed and fabricated two new nanostructured biosensing chips, with which the sensitive detection of prostate specific antigen (PSA) as low as 100 pg ml(-1) can be achieved, by measuring the plasmon enhanced fluorescence through a conventional dark field microscope. The gold nanostructure arrays, one with gold nanopillars of 140 nm, the other with gold nanoholes of 140 nm, were fabricated via nanoimprinting onto glass substrate, as localized surface plasmon resonance (LSPR) generators to enhance the fluorescent emission of fluorophore, e.g. quantum dot (QD). A sandwich bioassay of capture anti-PSA antibody (cAb)/PSA/detection anti-PSA (dAb) labeled by QD-655 was established on the nanostructures, and the perfect LSPR excitation distance (10-15 nm) between the nanostructure and QD-655 was simulated and controlled by a cleft cAb fragment and streptavidin modified QD. QD was chosen in this study due to its photo stability, broad Stokes shift, and long lifetime. As far as we know, this is the first time that QD is applied for PSA detection on the uniform nanostructured sensing chips based on the LSPR enhanced fluorescence. Due to the miniaturized nanoarray sensing chip (1.8 mm × 1.8 mm), the convenience and specificity for the detection of PSA via the sandwich assay, and the high optical detection sensitivity, the platform has great potential for the development of a portable point-of-care (POC) system for outpatient diagnosis and treatment monitoring.


Asunto(s)
Oro/química , Nanoestructuras/química , Antígeno Prostático Específico/análisis , Puntos Cuánticos , Resonancia por Plasmón de Superficie/instrumentación , Simulación por Computador , Diseño de Equipo , Técnica del Anticuerpo Fluorescente , Humanos , Modelos Biológicos , Nanotecnología , Tamaño de la Partícula , Resonancia por Plasmón de Superficie/métodos , Propiedades de Superficie
14.
ACS Appl Mater Interfaces ; 5(18): 8948-54, 2013 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-24000789

RESUMEN

Layer-by-layer assembled shells are prospective candidates for encapsulation, stabilization, storage, and release of fragrances. A shell comprising four alternative layers of a protein and a polyphenol is employed to encapsulate the dispersed phase of a fragrance-containing oil-in-water emulsion. The model fragrance used in this work consists of 10 ingredients, covering a range of typically employed aroma molecules, all premixed in equal mass and with sunflower oil acting as the base. The encapsulated emulsion is stable after 2 months of storage at 4 °C as revealed by static light scattering and confocal laser scanning microscopy. Gas chromatography/mass spectrometry data show that the encapsulation efficiency of 8 out of 10 fragrance ingredients depends on the water solubility: the less water-soluble an ingredient, the more of it is encapsulated. The amount of these fragrance ingredients remaining encapsulated decreases linearly upon emulsion incubation at 40 °C and the multilayer shell does not hinder their release. The other two fragrance ingredients having the lowest saturation vapor pressure demonstrate sustained release over 5 days of incubation at 40 °C. The composition of released fragrance remains almost constant over 3 days of incubation, upon further incubation it becomes enriched with these two ingredients when others start to be depleted.

SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda