RESUMEN
The left ventricular summit is a site of origin for idiopathic ventricular arrhythmias. With advancements in mapping and ablation techniques, sites previously considered inaccessible can now be approached. Anatomical knowledge of the 3-dimensional landmarks of this space is important, as critical structures reside within its boundaries and are potentially liable to collateral injury during ablation. This article reviews reported complications from ablation of ventricular arrhythmias arising from the left ventricular summit and its vicinity and discusses the pros and cons of different ablation technique and the role of an individualized anatomical approach to reduce procedural related complications and improve outcomes.
Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Humanos , Electrocardiografía , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/cirugía , Arritmias Cardíacas/cirugía , Taquicardia Ventricular/cirugíaRESUMEN
BACKGROUND: Our main objective was to present a multidisciplinary review on the epidemiology of sudden cardiac death (SCD) and the tools that could be used to identify malignant ventricular arrhythmias (VAs) and to perform risk stratification. In addition, indications and contraindications for the use of implantable cardioverter defibrillator (ICD) in general and in special populations including the elderly and patients with chronic kidney disease (CKD) are also given. METHODS: An expert group from the Inter American Society of Cardiology (IASC), through their HF Council (CIFACAH) and Electrocardiology Council (ElectroSIAC), together with the Latin American Heart Rhythm Society (LAHRS), reviewed and discussed the literature regarding the appropriate use of an ICD in people with heart failure (HF) with reduced ejection fraction (HFpEF). Indications and contraindications for the use of ICD are presented in this multidisciplinary review. RESULTS: Numerous clinical studies have demonstrated the usefulness of ICD in both primary and secondary prevention of SCD in HFpEF. There are currently precise indications and contraindications for the use of these devices. CONCLUSIONS: In some Latin American countries, a low rate of implantation is correlated with low incomes, but this is not the case for all Latin America. Determinants of the low rates of ICD implantation in many Latin American countries are still a matter of research. VA remains one of the most common causes of cardiovascular death associated with HFrEF and different tools are available for stratifying the risk of SCD in this population.
Asunto(s)
Cardiología , Desfibriladores Implantables , Insuficiencia Cardíaca , Disfunción Ventricular Izquierda , Humanos , Estados Unidos/epidemiología , Anciano , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/complicaciones , Volumen Sistólico , Arritmias Cardíacas/terapia , Muerte Súbita Cardíaca/epidemiología , Disfunción Ventricular Izquierda/complicaciones , Desfibriladores Implantables/efectos adversos , Factores de RiesgoRESUMEN
Al comienzo de la pandemia COVID-19 se implementaron pautas clínicas restrictivas de la asistencia que incluyeron los Servicios de Electrofisiología (SEF). Objetivo: analizar la actividad asistencial y conocer la situación de los SEF en Latinoamérica a dos meses de iniciadas las restricciones. Método: estudio observacional descriptivo-analítico y transversal, utilizando una encuesta a médicos electrofisiólogos en marzo/2020. Se comparó la actividad clínica e invasiva que se realizaba antes y durante la pandemia. Resultados: se incluyeron 147 encuestas, de 74 ciudades y 18 países de Latinoamérica. Los actos clínicos semanales se redujeron de 75 (45/127) a 20 (10/40) (p<0,001), bajaron 71%. Los procedimientos invasivos mensuales se redujeron de 26 (13/39) a 4 (2/9) (p<0,001), bajaron 77%. El 49% encuestado trabajaban en ≥3 centros asistenciales y 89% compartía laboratorio con un servicio de hemodinamia. La ocupación de camas en los hospitales era baja 37%, intermedia 28% y alta 35%. El 30% refirió algún médico de su equipo fue puesto en cuarentena por infección/contacto. El 53% refirió no se hacía ninguna prueba de tamizaje a los pacientes previa a los procedimientos y 77% al personal. La mayoría percibía dificultades como importantes o muy importantes, pero 63% estaba considerando la reapertura al funcionamiento normal. Conclusiones: hubo una reducción importante de la actividad clínica e invasiva. La mayoría no tenía alta ocupación de camas. Los encuestados trabajaban en varios centros y en salas de hemodinamia. Aún no se habían implementado totalmente las medidas de prevención. Existía la percepción de que en poco tiempo se retomaría la normalidad
At the beginning of the COVID-19 pandemic, restrictive clinical guidelines were implemented, including Electrophysiology Services (EFS). Objectives: analyze the healthcare activity and to know the situation of the EFS in Latin America two months after the restrictions began. Method: descriptive-analytical and cross-sectional observational study, using a survey of electrophysiologists in March / 2020. The clinical and invasive activity carried out before and during the pandemic was compared. Results: 147 surveys were included, from 74 cities in 18 Latin American countries. Weekly clinical events were reduced from 75 (45/127) to 20 (10/40) (p <0.001), they fell 71%. Monthly invasive procedures were reduced from 26 (13/39) to 4 (2/9) (p <0.001), down 77%. Forty-nine percent surveyed worked in ≥3 healthcare centers and 89% shared a laboratory with a hemodynamic service. Hospital bed occupancy was low 37%, intermediate 28% and high 35%. Thirty percent referred a doctor from their team was quarantined for infection / contact. Fifty-three percent reported that no screening test was done on the patients prior to the procedures and 77% on the staff. Most perceived difficulties as important or very important, but 63% were considering reopening to normal functioning. Conclusion: There was a significant reduction in clinical and invasive activity. Most did not have high bed occupancy. Respondents worked in various centers and in hemodynamic rooms. Prevention measures had not yet been fully implemented yet. There was a perception that in a short time normality would return.
No início da pandemia de COVID-19 foram implementadas diretrizes clínicas, incluindo os Serviços de Eletrofisiologia (SEF). Objetivo: analisar a atividade assistencial e conhecer a situação do SEF na América Latina dois meses após o início das restrições. Método: estudo descritivo-analítico e observacional transversal, por meio de questionário com eletrofisiologistas em março / 2020. Foi comparada a atividade clínica e invasiva realizada antes e durante a pandemia. Resultados: foram incluídos 147 inquéritos, de 74 cidades e 18 países latino-americanos. O número de procedimentos semanais foi reduzido de 75 (45/127) para 20 (10/40) (p <0,001), com redução de 71%. Os procedimentos invasivos mensais foram reduzidos de 26 (13/39) para 4 (2/9) (p <0,001), com redução de 77%. Dos eletrofisiologistas que responderam ao questionário, 49% trabalhavam em 3 ou mais centros, e 89% compartilhavam o laboratório com serviço de hemodinâmica. A ocupação de leitos hospitalares foi baixa em 37%, intermediária em 28% e alta em 35%. Dos que responderam al questionário, 30% relataram que um médico de sua equipe foi colocado em quarentena por infecção ou contato. Foi relatado que, dentre os que responderam, 53% não realizava teste de triagem nos pacientes antes dos procedimentos, e em 77% na equipe. A maioria percebeu as dificuldades como importantes ou muito importantes, mas 63% consideravam a reabertura ao funcionamento. Conclusões: houve redução significativa da atividade clínica e invasiva. A maioria não tinha grande ocupação de leitos. Os entrevistados trabalhavam em vários centros e em salas de hemodinâmica. As medidas de prevenção ainda não haviam sido totalmente implementadas, porém havia a percepção de que em pouco tempo a normalidade voltaria
Asunto(s)
Humanos , Servicio de Cardiología en Hospital/estadística & datos numéricos , Electrofisiología Cardíaca/estadística & datos numéricos , Pandemias , Atención al Paciente/estadística & datos numéricos , COVID-19/epidemiología , Estudios Transversales , Encuestas de Atención de la Salud , Estudio Observacional , COVID-19/prevención & control , América LatinaRESUMEN
Mujer de 70 años de edad, con historia de un electrodo de estimulación cardiaca abandonado, que genera: un trastorno de la deglución y una deformidad estética que la hacen consultar en múltiples oportunidades. A pesar de que se planteó la opción del retiro quirúrgico, se logró una extracción endovascular por la tracción de un electrodo. Describimos la utilidad del eco intracardiaco y el catéter ENSnare®, para la extracción de los electrodos en este tipo de casos.
70-year-old woman with a history of an abandoned pacing lead who developed a deglutition disorder and an aesthetic deformity that made her consult in multiple specialties. Even though surgical removal was considered, endovascular extraction was accomplished with the traction of the lead. We describe the usefulness of the intracardiac echocardiography and the ENSnare® catheter for this type of lead extractions.