Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Publication year range
1.
3D Print Med ; 10(1): 23, 2024 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-39028380

RESUMEN

BACKGROUND: The revolutionary technology of smartphone-based retinal imaging has been consistently improving over the years. Smartphone-based retinal image acquisition devices are designed to be portable, easy to use, and cost-efficient, which enables eye care to be more widely accessible especially in geographically remote areas. This enables early disease detection for those who are in low- and middle- income population or just in general has very limited access to eye care. This study investigates the limitation of smartphone compatibility of existing smartphone-based retinal image acquisition devices. Additionally, this study aims to propose a universal adapter design that is usable with an existing smartphone-based retinal image acquisition device known as the PanOptic ophthalmoscope. This study also aims to simulate the reliability, validity, and performance overall of the developed prototype. METHODS: A literature review has been conducted that identifies the limitation of smartphone compatibility among existing smartphone-based retinal image acquisition devices. Designing and modeling of proposed adapter were performed using the software AutoCAD 3D. For the proposed performance evaluation, finite element analysis (FEA) in the software Autodesk Inventor and 5-point scale method were demonstrated. RESULTS: Published studies demonstrate that most of the existing smartphone-based retinal imaging devices have compatibility limited to specific older smartphone models. This highlights the benefit of a universal adapter in broadening the usability of existing smartphone-based retinal image acquisition devices. A functional universal adapter design has been developed that demonstrates its compatibility with a variety of smartphones regardless of the smartphone dimension or the position of the smartphone's camera lens. The proposed performance evaluation method generates an efficient stress analysis of the proposed adapter design. The end-user survey results show a positive overall performance of the developed universal adapter. However, a significant difference between the expert's views on the developed adapter and the quality of images is observed. CONCLUSION: The compatibility of existing smartphone-based retinal imaging devices is still mostly limited to specific smartphone models. Besides this, the concept of a universal and suitable adapter for retinal imaging using the PanOptic ophthalmoscope was presented and validated in this paper. This work provides a platform for future development of smartphone-based ophthalmoscope that is universal.

2.
J Pharm Sci ; 109(8): 2485-2492, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32380181

RESUMEN

In this study, we demonstrated the fabrication of the concave conic shape microneedle with the aid of COMSOL Multiphysics simulation. The stress and buckling of the microneedle structure were simulated by applying various loads ranging from 50 to 800 g perpendiculars to the tip in order to predict the occurrence of microneedles structure deformation. The simulation study indicated that the surface buckling deformation does not occur to the microneedle structure with the increment of the load. The microneedles with dimensions of height and diameter tip ranging from 60 to 100 µm and 1 to 4 µm, respectively had been fabricated via an etching process in a mixture of hydrofluoric acid, nitric acid, and acetic acid. Three optimized microneedles but different in the structures were fabricated via the acidic etching process. The reproducibility of 3 different microneedle structures was 15, 20, and 60%, respectively. Stress and buckling analyses of the fabricated microneedles were further carried out on the rat skin. The obtained experimental results show promising applications for the deep dermis, stratum corneum to epidermis layer penetration.


Asunto(s)
Preparaciones Farmacéuticas , Silicio , Administración Cutánea , Animales , Sistemas de Liberación de Medicamentos , Microinyecciones , Agujas , Ratas , Reproducibilidad de los Resultados
3.
Comput Math Methods Med ; 2018: 4019538, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30065780

RESUMEN

Digital image processing is one of the most widely used computer vision technologies in biomedical engineering. In the present modern ophthalmological practice, biomarkers analysis through digital fundus image processing analysis greatly contributes to vision science. This further facilitates developments in medical imaging, enabling this robust technology to attain extensive scopes in biomedical engineering platform. Various diagnostic techniques are used to analyze retinal microvasculature image to enable geometric features measurements such as vessel tortuosity, branching angles, branching coefficient, vessel diameter, and fractal dimension. These extracted markers or characterized fundus digital image features provide insights and relates quantitative retinal vascular topography abnormalities to various pathologies such as diabetic retinopathy, macular degeneration, hypertensive retinopathy, transient ischemic attack, neovascular glaucoma, and cardiovascular diseases. Apart from that, this noninvasive research tool is automated, allowing it to be used in large-scale screening programs, and all are described in this present review paper. This paper will also review recent research on the image processing-based extraction techniques of the quantitative retinal microvascular feature. It mainly focuses on features associated with the early symptom of transient ischemic attack or sharp stroke.


Asunto(s)
Retinopatía Diabética/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador , Fractales , Fondo de Ojo , Humanos , Retina , Vasos Retinianos/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda