1.
Artif Organs ; 46(4): 705-709, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35080023

RESUMEN

BACKGROUND: Thrombotic complications continue to pose challenges to patients on left ventricular assist device (LVAD) support. The Hoplon system was developed to administer catheter-based lytic therapy with a novel approach to embolic protection. METHODS: Two porcine non-survival surgeries were performed in which off-pump LVAD insertion was followed by injection of thrombus into the impeller, isolation of the pump using the Hoplon system, and administration of lytic therapy to the pump chamber. Successful thrombus resolution was confirmed by pathological examination of the LVAD and brain tissue after animal sacrifice. RESULTS: Limitations of the prototype design resulted in the extrusion of thrombus from around the catheter in the first animal. Subsequent device modifications resulted in the resolution of LVAD thrombus as confirmed on removal and examination of the pump. Pathological examination of the brain tissue revealed the absence of any embolic or hemorrhagic complications. CONCLUSIONS: Early animal studies suggest feasibility in restoring function to an LVAD while at the same time preventing cerebroembolic events using the Hoplon system.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Trombosis , Animales , Catéteres/efectos adversos , Insuficiencia Cardíaca/terapia , Corazón Auxiliar/efectos adversos , Humanos , Estudios Retrospectivos , Porcinos , Trombosis/etiología , Trombosis/prevención & control , Resultado del Tratamiento
2.
JAMA ; 319(1): 27-37, 2018 01 02.
Artículo en Inglés | MEDLINE | ID: mdl-29297076

RESUMEN

Importance: Transcatheter aortic valve replacement (TAVR) is established for selected patients with severe aortic stenosis. However, limitations such as suboptimal deployment, conduction disturbances, and paravalvular leak occur. Objective: To evaluate if a mechanically expanded valve (MEV) is noninferior to an approved self-expanding valve (SEV) in high-risk patients with aortic stenosis undergoing TAVR. Design, Setting, and Participants: The REPRISE III trial was conducted in 912 patients with high or extreme risk and severe, symptomatic aortic stenosis at 55 centers in North America, Europe, and Australia between September 22, 2014, and December 24, 2015, with final follow-up on March 8, 2017. Interventions: Participants were randomized in a 2:1 ratio to receive either an MEV (n = 607) or an SEV (n = 305). Main Outcomes and Measures: The primary safety end point was the 30-day composite of all-cause mortality, stroke, life-threatening or major bleeding, stage 2/3 acute kidney injury, and major vascular complications tested for noninferiority (margin, 10.5%). The primary effectiveness end point was the 1-year composite of all-cause mortality, disabling stroke, and moderate or greater paravalvular leak tested for noninferiority (margin, 9.5%). If noninferiority criteria were met, the secondary end point of 1-year moderate or greater paravalvular leak was tested for superiority in the full analysis data set. Results: Among 912 randomized patients (mean age, 82.8 [SD, 7.3] years; 463 [51%] women; predicted risk of mortality, 6.8%), 874 (96%) were evaluable at 1 year. The primary safety composite end point at 30 days occurred in 20.3% of MEV patients and 17.2% of SEV patients (difference, 3.1%; Farrington-Manning 97.5% CI, -∞ to 8.3%; P = .003 for noninferiority). At 1 year, the primary effectiveness composite end point occurred in 15.4% with the MEV and 25.5% with the SEV (difference, -10.1%; Farrington-Manning 97.5% CI, -∞ to -4.4%; P<.001 for noninferiority). The 1-year rates of moderate or severe paravalvular leak were 0.9% for the MEV and 6.8% for the SEV (difference, -6.1%; 95% CI, -9.6% to -2.6%; P < .001). The superiority analysis for primary effectiveness was statistically significant (difference, -10.2%; 95% CI, -16.3% to -4.0%; P < .001). The MEV had higher rates of new pacemaker implants (35.5% vs 19.6%; P < .001) and valve thrombosis (1.5% vs 0%) but lower rates of repeat procedures (0.2% vs 2.0%), valve-in-valve deployments (0% vs 3.7%), and valve malpositioning (0% vs 2.7%). Conclusions and Relevance: Among high-risk patients with aortic stenosis, use of the MEV compared with the SEV did not result in inferior outcomes for the primary safety end point or the primary effectiveness end point. These findings suggest that the MEV may be a useful addition for TAVR in high-risk patients. Trial Registration: ClinicalTrials.gov Identifier: NCT02202434.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Bioprótesis , Enfermedades Cardiovasculares/etiología , Enfermedades Cardiovasculares/mortalidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Complicaciones Posoperatorias/etiología , Diseño de Prótesis , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
3.
Catheter Cardiovasc Interv ; 83(5): 824-30, 2014 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-23857738

RESUMEN

The antegrade approach for aortic valve interventions is well known but has not been widely used for transcatheter aortic valve replacement (TAVR) procedures. We encountered a patient with no possibility of retrograde access due to a totally occluded abdominal aorta who had a failed attempt at apical TAVR. We describe antegrade TAVR despite occlusion of the abdominal aorta, with the arterial limb of the requisite veno-arterial loop created using bilateral arm access, a novel version of the previously described antegrade approach.


Asunto(s)
Aorta Abdominal , Enfermedades de la Aorta/complicaciones , Estenosis de la Válvula Aórtica/terapia , Arteriopatías Oclusivas/complicaciones , Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas/métodos , Anciano , Aorta Abdominal/diagnóstico por imagen , Enfermedades de la Aorta/diagnóstico , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico , Aortografía/métodos , Arteriopatías Oclusivas/diagnóstico , Valvuloplastia con Balón , Humanos , Masculino , Radiografía Intervencional , Índice de Severidad de la Enfermedad , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
4.
Catheter Cardiovasc Interv ; 83(2): 280-8, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24038981

RESUMEN

BACKGROUND: Paravalvular leak (PVL) after transcatheter aortic valve replacement (TAVR) is associated with less good outcomes. The use of percutaneous plugs is among the strategies to treat PVL after TAVR. Plugs have been limited by the need to pass 4-6 F delivery sheaths between the TAVR stent frame and the native valve leaflets. METHODS: The study population consists of six patients who had at least moderate aortic insufficiency (AI), and also developed symptoms of heart failure after TAVR. We describe in detail the use of low profile vascular plugs that require crossing the leaks with only a 4 F diagnostic catheter. RESULTS: Low profile vascular plugs were successfully deployed in all six patients without significant complications. Fluoroscopy time ranged 16.7-69.4 min (44.8 ± 18.8 min). Contrast volume ranged 15-100 mL (45 ± 34 mL). One plug was used in five, and two adjacent plus in one case. AI severity was reduced from moderate or severe to mild or less in four patients, from severe to moderate in one, and in one, there was no change. Five of six patients were treated electively and were significantly improved in terms of both echocardiographic PVL and also symptoms. The one who did not have echocardiographic improvement did not improve clinically and expired one month later. CONCLUSIONS: PVL closure can be consistently accomplished after TAVR with low profile vascular plugs. Careful analysis of PVL location on echo before closure greatly facilitates finding the fluoroscopic location of the leak. Decreases in PVL severity are associated with significant clinical improvement.


Asunto(s)
Insuficiencia de la Válvula Aórtica/terapia , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Anciano , Anciano de 80 o más Años , Insuficiencia de la Válvula Aórtica/diagnóstico , Insuficiencia de la Válvula Aórtica/etiología , Medios de Contraste , Diseño de Equipo , Femenino , Fluoroscopía , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/terapia , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Masculino , Diseño de Prótesis , Radiografía Intervencional/métodos , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Izquierda/terapia
5.
Catheter Cardiovasc Interv ; 83(1): 162-8, 2014 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-23441087

RESUMEN

Aortic insufficiency (AI) after transcatheter aortic valve replacement (TAVR) is difficult to manage when associated with congestive heart failure. AI after balloon aortic valvuloplasty (BAV) may be catastrophic, especially in patients who are not candidates for TAVR. We describe the use of urgent temporary pacing, followed by permanent pacing, to increase the heart rate to diminish diastolic filling time for the short term management of AI after BAV or TAVR. The strategy is particularly useful in patients who already have permanent pacemakers, which are common in this population.


Asunto(s)
Insuficiencia de la Válvula Aórtica/terapia , Estenosis de la Válvula Aórtica/terapia , Valvuloplastia con Balón/efectos adversos , Cateterismo Cardíaco/efectos adversos , Estimulación Cardíaca Artificial/métodos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Anciano de 80 o más Años , Aorta/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/fisiopatología , Presión Arterial , Cateterismo Cardíaco/métodos , Electrocardiografía , Femenino , Frecuencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Masculino , Resultado del Tratamiento , Función Ventricular Izquierda , Presión Ventricular
6.
J Thorac Cardiovasc Surg ; 157(3): 907-916, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33198014

RESUMEN

BACKGROUND: Mitral valve replacement in the setting of severe mitral annular calcification remains a surgical challenge. Transcatheter mitral valve replacement (TMVR) using an aortic balloon-expandable transcatheter heart valve is emerging as a potential treatment option for high surgical risk patients. Transseptal, transapical, or transatrial access is not always feasible, so an understanding of alternative implantation techniques is important. OBJECTIVES: The authors sought to present a step-by-step description of a contemporary transatrial TMVR technique using balloon-expandable aortic transcatheter heart valves. This procedure has evolved over time to address valve migration, left ventricular outflow tract obstruction, and paravalvular leak. The authors present a refined technique that has been associated with the most reproducible outcomes. METHODS: A step-by-step description of the TMVR technique and outcomes of 8 patients treated using this technique are described. Baseline patient clinical and echocardiographic characteristics and 30-day post-TMVR outcomes are presented. RESULTS: Eight patients underwent transatrial TMVR at a single institution. Five had previous cardiac surgery. Mean STS score was 8%. Technical success by MVARC (Mitral Valve Academic Research Consortium) criteria was 100%. There was zero in-hospital and 30-day mortality. Procedural success by MVARC criteria at 30 days was 100%. Paravalvular leak immediately post-implant was none or trace in 6 and mild in 1. CONCLUSIONS: The technique described is reproducible and was associated with favorable outcomes in this early experience. It represents a useful technique for the treatment of mitral valve disease in the setting of severe annular calcification. A structured and defined implantation technique is critical to investigators as this field evolves.

7.
J Am Coll Cardiol ; 72(13): 1437-1448, 2018 09 25.
Artículo en Inglés | MEDLINE | ID: mdl-30236304

RESUMEN

BACKGROUND: Mitral valve replacement in the setting of severe mitral annular calcification remains a surgical challenge. Transcatheter mitral valve replacement (TMVR) using an aortic balloon-expandable transcatheter heart valve is emerging as a potential treatment option for high surgical risk patients. Transseptal, transapical, or transatrial access is not always feasible, so an understanding of alternative implantation techniques is important. OBJECTIVES: The authors sought to present a step-by-step description of a contemporary transatrial TMVR technique using balloon-expandable aortic transcatheter heart valves. This procedure has evolved over time to address valve migration, left ventricular outflow tract obstruction, and paravalvular leak. The authors present a refined technique that has been associated with the most reproducible outcomes. METHODS: A step-by-step description of the TMVR technique and outcomes of 8 patients treated using this technique are described. Baseline patient clinical and echocardiographic characteristics and 30-day post-TMVR outcomes are presented. RESULTS: Eight patients underwent transatrial TMVR at a single institution. Five had previous cardiac surgery. Mean STS score was 8%. Technical success by MVARC (Mitral Valve Academic Research Consortium) criteria was 100%. There was zero in-hospital and 30-day mortality. Procedural success by MVARC criteria at 30 days was 100%. Paravalvular leak immediately post-implant was none or trace in 6 and mild in 1. CONCLUSIONS: The technique described is reproducible and was associated with favorable outcomes in this early experience. It represents a useful technique for the treatment of mitral valve disease in the setting of severe annular calcification. A structured and defined implantation technique is critical to investigators as this field evolves.


Asunto(s)
Calcinosis/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Válvula Mitral/cirugía , Anciano , Anciano de 80 o más Años , Valvuloplastia con Balón , Femenino , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Cuidados Posoperatorios , Cuidados Preoperatorios , Tomografía Computarizada por Rayos X
8.
J Invasive Cardiol ; 29(8): 277-279, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28756421

RESUMEN

Several options are available to address hemostasis at the end of a cardiac catheterization or percutaneous transfemoral transcatheter aortic valve replacement (TAVR) when conventional options are ineffective. To date, there have been few studies exploring the use of a topical thrombin preparation, as one of its main contraindications is that it cannot be used intravascularly due to risk of embolization. The following case shows safe utilization of Surgiflo hemostatic gel matrix under fluoroscopic guidance against an inflated balloon in order to achieve closure of a fistulous tract from a femoral artery access site during percutaneous TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Cateterismo Periférico/efectos adversos , Fístula Cutánea , Arteria Femoral , Hemostasis Quirúrgica/métodos , Hemostáticos/administración & dosificación , Hemorragia Posoperatoria , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Fístula Vascular , Anciano , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/fisiopatología , Cateterismo Periférico/métodos , Angiografía por Tomografía Computarizada/métodos , Fístula Cutánea/diagnóstico , Fístula Cutánea/etiología , Fístula Cutánea/terapia , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/cirugía , Humanos , Masculino , Hemorragia Posoperatoria/diagnóstico , Hemorragia Posoperatoria/etiología , Hemorragia Posoperatoria/terapia , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento , Ultrasonografía Doppler/métodos , Fístula Vascular/diagnóstico , Fístula Vascular/etiología , Fístula Vascular/terapia
9.
Interv Cardiol Clin ; 5(1): 83-91, 2016 01.
Artículo en Inglés | MEDLINE | ID: mdl-27852484

RESUMEN

Therapy for mitral regurgitation (MR) has been synonymous with mitral valve surgery. Operative approaches for degenerative MR repair have been associated with excellent results, with durable long term outcomes. Surgery for functional MR has been less successful. MitraClip has shown promise for functional MR, especiall in patinets who are high risk for surgery. The aggregate of nonrandomized global experience with MitraClip in functional MR has been consistent in showing improvements in symptoms and left ventricular remodeling. It remains to be seen how MitraClip therapy will compare with best medical therapy. The COAPT trial will clarify this question.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral/cirugía , Humanos , Resultado del Tratamiento , Remodelación Ventricular
10.
JTCVS Tech ; 3: 263-264, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34317894
11.
J Invasive Cardiol ; 26(4): 180-2, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24717276

RESUMEN

Surgical left atrial appendage (LAA) exclusion has a failure rate as high as 60% due to persistent residual flow in the LAA or large LAA remnants. We describe a novel technique for treatment of incomplete surgical LAA ligation, and define the mechanism that led to persistence of the remnant LAA without any thrombus formation.


Asunto(s)
Angioplastia/métodos , Apéndice Atrial/cirugía , Aleteo Atrial/cirugía , Atrios Cardíacos/cirugía , Dispositivo Oclusor Septal , Anciano , Angiografía , Apéndice Atrial/diagnóstico por imagen , Ecocardiografía Transesofágica , Atrios Cardíacos/diagnóstico por imagen , Humanos , Ligadura , Masculino , Instrumentos Quirúrgicos , Resultado del Tratamiento
13.
J Invasive Cardiol ; 23(4): 157-61, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21474850

RESUMEN

Over the last decade, significant developments have been made in the treatment of structural heart disease. Some of these techniques require placement of large arterial sheaths for device delivery. Optimal vascular access is essential for successful large-vessel sheath insertion as well as to avoid vascular complications. The critical step for ideal percutaneous vessel entry is single anterior wall-only puncture of the common femoral artery in a location above the femoral bifurcation and below the inguinal ligament. We describe a fluoroscopically-guided micropuncture technique for accurate placement of large-caliber arterial sheaths.


Asunto(s)
Angioplastia/métodos , Arteria Femoral , Fluoroscopía/métodos , Punciones/métodos , Angiografía , Angioplastia/instrumentación , Cardiopatías/terapia , Humanos , Técnicas de Sutura
15.
Int J Cardiovasc Imaging ; 23(5): 591-3, 2007 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-17171430

RESUMEN

Transient left ventricular apical hypokinesis results in a typical ampullary shape and has been described as Takotsubo cardiomyopathy (TCM). We report a case of TCM with the rare complication of left ventricular thrombus formation. Cardiac magnetic resonance imaging aided the diagnosis by characterizing the non-enhancing mass and evaluating the surrounding myocardium for scarring.


Asunto(s)
Cardiopatías/patología , Imagen por Resonancia Magnética , Cardiomiopatía de Takotsubo/complicaciones , Trombosis/patología , Anciano , Ecocardiografía , Cardiopatías/etiología , Cardiopatías/fisiopatología , Ventrículos Cardíacos/patología , Humanos , Masculino , Ventriculografía con Radionúclidos , Cardiomiopatía de Takotsubo/patología , Cardiomiopatía de Takotsubo/fisiopatología , Trombosis/etiología , Trombosis/fisiopatología , Función Ventricular Izquierda
16.
Catheter Cardiovasc Interv ; 67(1): 132-8, 2006 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-16345060

RESUMEN

We describe percutaneous closure of an unusual paravalvular leak, with a communication from the noncoronary cusp of the aortic valve to the left atrium adjacent to a St. Jude mitral valve prosthesis, in the absence of an infection. The patient presented with worsening dyspnea and edema. The anatomic location of the valve annulus adjacent to the noncoronary cusp underlies the etiology of this communication. Outcomes from surgical repair are associated with high mortality. We performed percutaneous closure of the defect, using general anesthesia and transesophageal echo guidance. An Amplatzer duct occluder was placed in the fistula, with immediate and complete closure of the shunt. While no devices specific for closure of paravalvular leaks have been designed, growing experience with a variety of devices and the use of echo guidance have allowed successful therapy in many complex cases.


Asunto(s)
Enfermedades de la Aorta/terapia , Atrios Cardíacos , Prótesis e Implantes , Fístula Vascular/terapia , Anciano , Cateterismo Cardíaco , Ecocardiografía Transesofágica , Femenino , Humanos
17.
Catheter Cardiovasc Interv ; 67(4): 611-6, 2006 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-16532492

RESUMEN

An 85-year-old man was found to have a 9 cm diameter true aneurysm of an obtuse marginal saphenous vein graft. The graft was fed by a relatively narrow neck from the proximal remnant of the obtuse marginal graft 10 years after prior coronary artery bypass graft surgery. An Amplatzer vascular plug was used successfully to occlude the neck of the aneurysm. Follow-up CT scan 1 month afterward demonstrated retained contrast in the aneurysm, demonstrating complete occlusion between the aorta and aneurysm sac. Pressure recordings from within the aneurysm sac suggest bidirectional flow in the neck as the mechanism for the maintained patency of the aneurysm. The use of a vascular plug is an effective method for aneurysm occlusion when the anatomy is suitable.


Asunto(s)
Aneurisma Coronario/etiología , Aneurisma Coronario/terapia , Puente de Arteria Coronaria/efectos adversos , Embolización Terapéutica/instrumentación , Vena Safena , Anciano de 80 o más Años , Aneurisma Coronario/diagnóstico por imagen , Humanos , Masculino , Radiografía , Vena Safena/trasplante
18.
Catheter Cardiovasc Interv ; 64(3): 314-21, 2005 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15736255

RESUMEN

Percutaneous balloon aortic valvuloplasty (BAV) has been limited predominantly to a palliative treatment for poor surgical candidates with critical aortic stenosis and multiple high-risk or comorbid conditions. The most commonly used technique for BAV is the retrograde approach, in which the balloon is passed via the femoral artery using 12-14 Fr sheaths. We compared an antegrade transseptal approach using the Inoue balloon vs. the retrograde transarterial approach using conventional balloons. The antegrade group had an improved acute hemodynamic outcome, including 20% additional increase of aortic valve area and 20% greater reduction of transaortic valve gradient compared to the retrograde approach. Preclosure with the Perclose device was used for the 14 Fr venous access sites, resulting in immediate hemostasis, minimizing the need for transfusion, and diminishing the period of bed rest. The improved acute efficacy and relative ease of venous access for the antegrade approach facilitate BAV by eliminating the need for large-caliber arterial access sheaths. The antegrade approach also incorporates technical elements necessary for percutaneous aortic valve replacement and may have expanded applications as an adjunct to this developing therapy. The impact of improved acute results on the long-term clinical outcome for this patient group will require further study.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Cateterismo/métodos , Factores de Edad , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Cateterismo/instrumentación , Cateterismo/mortalidad , Ecocardiografía Transesofágica , Diseño de Equipo , Femenino , Arteria Femoral , Vena Femoral , Estudios de Seguimiento , Tabiques Cardíacos , Humanos , Masculino , Cuidados Paliativos/métodos , Estudios Retrospectivos , Factores de Riesgo , Tasa de Supervivencia , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS