Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
Publication year range
1.
Materials (Basel) ; 13(8)2020 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-32344699

RESUMEN

Improved implant osteointegration offers meaningful potential for orthopedic, spinal, and dental implants. In this study, a laser treatment was used for the structuring of a titanium alloy (Ti6Al4V) surface combined with a titanium dioxide coating, whereby a porous surface was created. The objective was to characterize the pore structure shape, treatment-related metallographic changes, cytocompatibility, and attachment of osteoblast-like cells (MG-63). The treatment generated specific bottleneck pore shapes, offering the potential for the interlocking of osteoblasts within undercuts in the implant surface. The pore dimensions were a bottleneck diameter of 27 µm (SD: 4 µm), an inner pore width of 78 µm (SD: 6 µm), and a pore depth of 129 µm (SD: 8 µm). The introduced energy of the laser changed the metallic structure of the alloy within the heat-affected region (approximately 66 µm) without any indication of a micro cracking formation. The phase of the alloy (microcrystalline alpha + beta) was changed to a martensite alpha phase in the surface region and an alpha + beta phase in the transition region between the pores. The MG-63 cells adhered to the structured titanium surface within 30 min and grew with numerous filopodia over and into the pores over the following days. Cell viability was improved on the structured surface compared to pure titanium, indicating good cytocompatibility. In particular, the demonstrated affinity of MG-63 cells to grow into the pores offers the potential to provide significantly improved implant fixation in further in vivo studies.

2.
RSC Adv ; 10(65): 39854-39869, 2020 Oct 27.
Artículo en Inglés | MEDLINE | ID: mdl-35558137

RESUMEN

Tailoring the surface properties of materials for biomedical applications is important to avoid clinical complications. Forming thin layers of amphiphilic molecules with apolar regions that facilitate attractive intermolecular interactions, can be a suitable and versatile approach to achieve hydrophobic surface modification and provide functional antibacterial properties. Aiming to correlate layer structure and properties starting from film formation, octadecylphosphonic acid (ODPA) and dimethyloctadecyl (3-trimethoxysilylpropyl) ammonium chloride (DMOAP) layers were adsorbed onto smooth titania surfaces. Then the films were studied by atomic force microscopy (AFM) and X-ray Photoelectron Spectroscopy (XPS), and their interactions with aqueous environments were characterized by contact angle and zeta potential measurements. In addition, antibacterial assays were performed using E. coli and S. mutants to reveal the antibacterial properties effected by the surface modification. Immediately after sputter deposition, titania was hydrophilic; however, after air storage and adsorption of DMOAP or ODPA, an increase in the water contact angle was observed. XPS investigations after layer formation and after antibacterial tests revealed that the attachment of layers assembled from ODPA on titania substrates is considerably stronger and more stable than that observed for DMOAP films. Heat treatment strongly affects DMOAP layers. Furthermore, DMOAP layers are not stable under biological conditions.

3.
Materials (Basel) ; 12(23)2019 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-31766488

RESUMEN

Implant-associated infections represent a serious risk in human medicine and can lead to complications, revisions and in worst cases, amputations. To target these risks, the objective was to design a hybrid implant surface that allows a local burst release of antibiotics combined with long-term antimicrobial activity based on silver. The efficacy should be generated with simultaneous in vitro cytocompatibility. The investigations were performed on titanium K-wires and plates and gentamicin was selected as an illustrative antibiotic. A gentamicin depot (max 553 µg/cm2) was created on the surface using laser structuring. The antibiotic was released within 15 min in phosphate buffered saline (PBS) or agar medium. Metallic silver particles (4 µg/cm2) in a titanium dioxide layer were deposited using plasma vapor deposition (PVD). About 16% of the silver was released within 28 days in the agar medium. The local efficacy of the incorporated silver was demonstrated in a direct contact assay with a reduction of more than 99.99% (Escherichia coli). The local efficacy of the hybrid surface was confirmed in a zone of inhibition (ZOI) assay using Staphylococcus cohnii. The biocompatibility of the hybrid surface was proven using fibroblasts and osteoblasts as cell systems. The hybrid surface design seems to be promising as treatment of implant-associated infections, considering the achieved amount and release behavior of the active ingredients (gentamicin, silver). The generated in vitro results (efficacy, biocompatibility) proofed the concept. Further in vivo studies will be necessary translate the hybrid surface towards clinical applied research.

4.
ACS Appl Bio Mater ; 2(12): 5749-5759, 2019 Dec 16.
Artículo en Inglés | MEDLINE | ID: mdl-35021568

RESUMEN

Biofouling constitutes a major challenge in the application of biosensors and biomedical implants, as well as for (food) packaging and marine equipment. In this work, an antifouling surface coating based on the combination of mussel-inspired dendritic polyglycerol (MI-dPG) and an amine-functionalized block copolymer of linear polyglycerol (lPG-b-OA11, OA = oligo-amine) was developed. The coating was compared to a MI-dPG surface which was postfunctionalized with commercially available amine-terminated polyethylene glycol (HO-PEG-NH2) of similar molecular weight. In the current work, these coatings were compared in their chemical stability, protein fouling characteristics, and cell fouling characteristics. The lPG-b-OA11-functionalized coating showed high chemical stability in both phosphate buffered saline (PBS) and sodium dodecyl sulfate (SDS) solutions and reduced the adhesion of fibrinogen from human plasma with 99% and the adhesion of human serum albumin with 96%, in comparison to the bare titanium dioxide substrate. Furthermore, the proliferation of human umbilical vein endothelial cells (HUVECs) was reduced with 85% when the lPG-b-OA11 system was compared to bare titanium dioxide. Additionally, a reduction of 94% was observed when the lPG-b-OA11 system was compared to tissue culture polystyrene.

SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda