Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Thorac Cardiovasc Surg ; 125(4): 797-808, 2003 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-12698142

RESUMEN

OBJECTIVE: Retrospective comparisons of selected patients undergoing off-pump versus conventional on-pump coronary artery bypass grafting have yielded inconsistent results and raised concerns about completeness of revascularization in off-pump coronary artery bypass grafting. METHODS: Two hundred unselected patients referred for elective primary coronary artery bypass grafting were randomly assigned to undergo off-pump coronary artery bypass grafting with an Octopus tissue stabilizer (Medtronic, Inc, Minneapolis, Minn) or conventional coronary artery bypass grafting with cardiopulmonary bypass by a single surgeon. Revascularization intent determined before random assignment was compared with the revascularization performed. All management followed strict, unbiased, criteria-driven protocols. Patients and nonoperative care providers were blinded to surgical group. RESULTS: Baseline characteristics were similar. The number of grafts performed per patient (mean +/- SD 3.39 +/- 1.04 for off-pump coronary artery bypass grafting, 3.40 +/- 1.08 for conventional coronary artery bypass grafting) and the index of completeness of revascularization (number of grafts performed/number of grafts intended, 1.00 +/- 0.18 for off-pump coronary artery bypass grafting, 1.01 +/- 0.09 for conventional coronary artery bypass grafting) were similar. Likewise, the index of completeness of revascularization was similar between groups for the lateral wall. Combined hospital and 30-day mortalities and stroke rates were similar. Postoperative myocardial serum enzyme measures were significantly lower after off-pump coronary artery bypass grafting, suggesting less myocardial injury. Adjusted postoperative thromboelastogram indices, fibrinogen, international normalized ratio, and platelet levels all showed significantly less coagulopathy after off-pump coronary artery bypass grafting. Patients undergoing off-pump coronary artery bypass grafting received fewer units of blood, were more likely to avoid transfusion altogether, and had a higher hematocrit at discharge. Cardiopulmonary bypass was an independent predictor of transfusion (odds ratio 2.42, P =.0073) by multivariate analysis. More patients undergoing off-pump coronary artery bypass grafting were extubated in the operating room and within 4 hours. Postoperative length of stay (in days) was shorter for off-pump coronary artery bypass grafting (5.1 +/- 6.5 for off-pump coronary artery bypass grafting, 6.1 +/- 8.2 for conventional coronary artery bypass grafting, P =.005 by Wilcoxon test). One patient (in the conventional coronary artery bypass grafting group) required angioplasty for graft closure within 30 days. CONCLUSIONS: When compared with conventional coronary artery bypass grafting with cardiopulmonary bypass, off-pump coronary artery bypass grafting achieved similar completeness of revascularization, similar in-hospital and 30-day outcomes, shorter length of stay, reduced transfusion requirement, and less myocardial injury.


Asunto(s)
Puente de Arteria Coronaria/métodos , Transfusión Sanguínea , Femenino , Estudios de Seguimiento , Humanos , Tiempo de Internación , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Estudios Retrospectivos
2.
Ann Thorac Surg ; 71(1): 319-22; discussion 323, 2001 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-11216769

RESUMEN

BACKGROUND: Prolonged air leak is the major limiting factor in early hospital discharge following pulmonary resection. The purpose of this study was to determine whether the use of bovine pericardial strips as a buttress along the lung staple line would decrease air leaks and hospital stay after lobectomy and segmentectomy. METHODS: This was a multicenter trial consisting of 80 patients undergoing pulmonary resection, randomly assigned to the control group (40 patients) or treatment group (40 patients). The treatment group had reinforcement with bovine pericardium. RESULTS: No statistical differences were noted in the mean intensive care unit length of stay (p = 0.9), number of days with a chest tube (p = 0.6), or total length of stay (p = 0.24). Increased air leak duration was associated with assignment to the control group (r = 0.27, p = 0.02). The mean duration of air leak was 2 days and the mean time to chest tube removal was 5.9 days in patients with a buttressed staple line compared to 3 days and 6.3 days, respectively, for patients with nonbuttressed staple lines. CONCLUSIONS: Within the data of this study, no statistical differences were noted between buttressed and nonbuttressed patients. However, the trend toward shortened air leak time and tube removal time was apparent in the buttressed group. With greater number of patients studied, it is likely that the cost of bovine pericardium would be justified by shorter air leak duration and hospitalization.


Asunto(s)
Neumonectomía , Grapado Quirúrgico/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Georgia , Costos de Hospital , Humanos , Tiempo de Internación , Masculino , Persona de Mediana Edad , Neumonectomía/economía , Complicaciones Posoperatorias , Grapado Quirúrgico/economía
3.
Ann Thorac Surg ; 71(5): 1477-83; discussion 1483-4, 2001 May.
Artículo en Inglés | MEDLINE | ID: mdl-11383786

RESUMEN

BACKGROUND: This retrospective study compared clinical outcomes and resource utilization in patients having off-pump coronary artery bypass grafting (OPCAB) versus conventional coronary artery bypass grafting (CABG). Angiographic patency was documented in the OPCAB group. METHODS: From April 1997 through November 1999, OPCAB was performed in 200 consecutive patients, and the results were compared with those in a contemporaneous matched control group of 1,000 patients undergoing CABG. Patients were matched according to age, sex, preexisting disease (renal failure, diabetes, pulmonary disease, stroke, hypertension, peripheral vascular disease, previous myocardial infarction, and primary or redo status. Follow-up in the OPCAB patients was 93% and averaged 13.4 months. RESULTS: Hospital death (1.0%), postoperative stroke (1.5%), myocardial infarction (1.0%), and re-entry for bleeding (1.5%) occurred infrequently in the OPCAB group. There were reductions in the rates of transfusion (33.0% versus 70.0%; p < 0.001) and deep sternal wound infection (0% versus 2.2%; p = 0.067) in the OPCAB group compared with the CABG group. Angiographic assessment of 421 grafted arteries was performed in 167 OPCAB patients (83.5%) prior to hospital discharge. All but five were patent (98.8%) (93.3% FitzGibbon A, 5.5% FitzGibbon B, 1.2% FitzGibbon O). All 163 internal mammary artery grafts were patent. Off-pump coronary artery bypass grafting reduced postoperative hospital stay from 5.7 +/- 5.3 days in the CABG group to 3.9 +/- 2.6 days (p < 0.001), with a decrease in hospital cost of 15.0% (p < 0.001). CONCLUSIONS: Off-pump coronary artery bypass grafting reduces hospital cost, postoperative length of stay, and morbidity compared with CABG on cardiopulmonary bypass. Off-pump coronary bypass grafting is safe, cost effective, and associated with excellent graft patency and clinical outcomes.


Asunto(s)
Puente Cardiopulmonar/economía , Angiografía Coronaria/economía , Puente de Arteria Coronaria/economía , Enfermedad Coronaria/cirugía , Costos de Hospital/estadística & datos numéricos , Complicaciones Posoperatorias/economía , Anciano , Anciano de 80 o más Años , Enfermedad Coronaria/diagnóstico por imagen , Enfermedad Coronaria/economía , Enfermedad Coronaria/mortalidad , Ahorro de Costo , Femenino , Estudios de Seguimiento , Mortalidad Hospitalaria , Humanos , Tiempo de Internación/economía , Masculino , Persona de Mediana Edad , Readmisión del Paciente/economía , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/mortalidad , Tasa de Supervivencia
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda