Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Catheter Cardiovasc Interv ; 101(1): 187-196, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36378620

RESUMEN

BACKGROUND: New-onset left bundle branch block (LBBB) can develop after transcatheter aortic valve replacement (TAVR) resulting in worse outcomes. AIMS: Describe clinical and echocardiographic outcomes with new-onset LBBB after TAVR. METHODS: We included consecutive patients who underwent transfemoral-TAVR with SAPIEN-3 (S3) valve between April 2015 and December 2018. Exclusion criteria included pre-existing LBBB, right BBB, left anterior hemiblock, left posterior hemiblock, wide QRS ≥ 120ms, prior permanent pacemaker (PPM), and nontransfemoral access. RESULTS: Among 612 patients, 11.4% developed new-onset LBBB upon discharge. The length of stay was longer with new-onset LBBB compared with no LBBB [3 (2-5) days versus 2 (1-3) days; p < 0.001]. New-onset LBBB was associated with higher rates of 30-day PPM requirement (18.6% vs. 5.4%; p < 0.001) and 1-year heart failure hospitalizations (10.7% vs. 4.4%; p = 0.033). There was no difference in 3-year mortality between both groups (30.9% vs. 30.6%; p = 0.829). Further, new-onset LBBB was associated with lower left ventricular ejection fraction (LVEF) at both 30 days (55.9 ± 11.4% vs. 59.3 ± 9%; p = 0.026) and 1 year (55 ± 12% vs. 60.1 ± 8.9%; p = 0.002). These changes were still present when we stratified patients according to baseline LVEF (≥50% or <50%). New-onset LBBBs were associated with a higher 1-year LV end-diastolic volume index (51.4 ± 18.6 vs. 46.4 ± 15.1 ml/m2 ; p = 0.036), and LV end-systolic volume index (23.2 ± 14.1 vs. 18.9 ± 9.7 ml/m2 ; p = 0.009). Compared with resolved new-onset LBBB, persistent new-onset LBBB was associated with worse LVEF and higher PPM at 1 year. CONCLUSIONS: New-onset LBBB after S3 TAVR was associated with higher PPM requirement, worse LVEF, higher LV volumes, and increased heart failure hospitalizations, with no difference in mortality.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia Cardíaca , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/etiología , Bloqueo de Rama/terapia , Volumen Sistólico , Función Ventricular Izquierda , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Arritmias Cardíacas , Ecocardiografía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
2.
Europace ; 25(5)2023 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-37021812

RESUMEN

AIMS: To evaluate the efficacy of oesophageal cooling in the prevention of oesophageal injury in patients undergoing atrial fibrillation (AF) catheter ablation. METHODS AND RESULTS: Comprehensive search of MEDLINE, EMBASE, and Cochrane databases through April 2022 for randomized controlled trials (RCTs) evaluating the role of oesophageal cooling compared with control in the prevention of oesophageal injury during AF catheter ablation. The study primary outcome was the incidence of any oesophageal injury. The meta-analysis included 4 RCTs with a total of 294 patients. There was no difference in the incidence of any oesophageal injury between oesophageal cooling and control [15% vs. 19%; relative risk (RR) 0.86; 95% confidence interval (CI) 0.31-2.41]. Compared with control, oesophageal cooling showed lower risk of severe oesophageal injury (1.5% vs. 9%; RR 0.21; 95% CI 0.05-0.80). There were no significant differences among the two groups in mild to moderate oesophageal injury (13.6% vs. 12.1%; RR 1.09; 95% CI 0.28-4.23), procedure duration [standardized mean difference (SMD) -0.03; 95% CI -0.36-0.30], posterior wall radiofrequency (RF) time (SMD 0.27; 95% CI -0.04-0.58), total RF time (SMD -0.50; 95% CI -1.15-0.16), acute reconnection incidence (RR 0.93; 95% CI 0.02-36.34), and ablation index (SMD 0.16; 95% CI -0.33-0.66). CONCLUSION: Among patients undergoing AF catheter ablation, oesophageal cooling did not reduce the overall risk of any oesophageal injury compared with control. Oesophageal cooling might shift the severity of oesophageal injuries to less severe injuries. Further studies should evaluate the long-term effects after oesophageal cooling during AF catheter ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Enfermedades del Esófago , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ensayos Clínicos Controlados Aleatorios como Asunto , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Resultado del Tratamiento
3.
J Card Fail ; 28(7): 1222-1226, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35318127

RESUMEN

BACKGROUND: There are limited data regarding the management of guideline-directed medical therapy (GDMT) for heart failure with reduced ejection fraction (HFrEF) with virtual visits in comparison with in-office visits. We sought to compare the changes in GDMT (angiotensin-converting enzyme inhibitors, angiotensin II receptor blockers, angiotensin receptor neprilysin inhibitors, mineralocorticoid receptor antagonists, and sodium glucose cotransporter-2 inhibitors) and loop diuretics across visit types. METHODS AND RESULTS: This study included 13,481 outpatient visits performed for 5439 unique patients with HFrEF between March 16, 2020, and March 15, 2021. The rates of initiation and discontinuation of GDMT were documented, and multivariable logistic regression was performed to test associations with outcomes between modes of visit. The rates of medication initiation were higher in office (11.7%) compared with video (9.6%) or telephone (7.2%) visits. In multivariable adjusted analysis, the initiation of at least 1 GDMT class was similar between in-office visits and video visits (adjusted odds ratio [OR] 0.97, 95% confidence interval [CI] 0.82-1.14, P = .703). Telephone visits were associated with less frequent initiation of at least 1 class of GDMT in comparison with in-office visits (adjusted OR 0.64, 95% CI 0.55-0.75; P < .001) and video visits (adjusted OR 0.67, 95% CI 0.55-0.81, P < .001). Despite similar rates of baseline loop diuretic use, patients seen with both video visits (adjusted OR 0.70, 95% CI 0.52-0.94, P = .018) and telephone visits (adjusted OR 0.64, 95% CI 0.49-0.83, P < .001) were less likely to have a loop diuretic initiated when compared with in-office visits. CONCLUSIONS: The initiation of GDMT for HFrEF was similar between in-office and video visits and lower with telephone visits, whereas the initiation of a loop diuretic was less frequent in both types of virtual visits. These data suggest that video streaming capabilities should be encouraged for virtual visits.


Asunto(s)
Insuficiencia Cardíaca , Telemedicina , Antagonistas Adrenérgicos beta/uso terapéutico , Antagonistas de Receptores de Angiotensina/farmacología , Antagonistas de Receptores de Angiotensina/uso terapéutico , Insuficiencia Cardíaca/tratamiento farmacológico , Insuficiencia Cardíaca/epidemiología , Humanos , Pacientes Ambulatorios , Inhibidores del Simportador de Cloruro Sódico y Cloruro Potásico/uso terapéutico , Volumen Sistólico , Teléfono
4.
Catheter Cardiovasc Interv ; 99(5): 1636-1644, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35132765

RESUMEN

BACKGROUND: There is a paucity of data regarding the sex-related differences in the trends and outcomes of trans-septal transcatheter mitral valve replacement (TS-TMVR). METHODS: The Nationwide Readmissions Database (2015-2018) was queried for admissions for TS-TMVR. Propensity matched analysis was conducted to compare outcomes with hospitalizations for TS-TMVR among women versus men. The main study outcome was in-hospital mortality. RESULTS: Our final analysis included 2063 hospitalizations for TS-TMVR; of whom, 58.1% were women. The proportion of women among those undergoing TS-TMVR increased from 50% in 2015 to 60.2% in 2018 (Ptrend = 0.04). Compared with men, women undergoing TS-TMVR were slightly younger, and had a distinct profile of comorbidities. After matching, there was no significant difference in in-hospital mortality among women versus men undergoing TS-TMVR (7.8% vs. 6.1%, OR = 1.30; 95% CI: 0.79-2.13). Subgroup analyzes showed an interaction toward higher mortality with women versus men among patients with CKD (Pinteraction = 0.07). There were no significant differences between women and men in in-hospital complications or length of stay after TS-TMVR. Compared with men, women undergoing TS-TMVR were more likely to be discharged to a nursing facility (17.7% vs. 11.5%, p = 0.01) and had higher rates of 30-day readmissions (22.4% vs. 13.6%, p = 0.01). CONCLUSION: This nationwide analysis showed an increase in the proportion of women among patients undergoing TS-TMVR during the study years. There were no differences in in-hospital mortality, in-hospital complications, or length of stay between both sexes following TS-TMVR. Women were more likely to be discharged to nursing facilities and had higher rates of readmission at 30 days even after propensity matching.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Cateterismo Cardíaco/efectos adversos , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Readmisión del Paciente , Resultado del Tratamiento
5.
J Card Fail ; 27(7): 812-815, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33753241

RESUMEN

BACKGROUND: Statins are recommended in heart transplant patients, but are sometimes poorly tolerated. Alternative agents are often considered including proprotein convertase subtilisin/kexin type-9 inhibitors (PCSK9i). We sought to investigate the use of PCSK9i after heart transplantation. METHODS AND RESULTS: We identified patients who received a heart transplant from 1999 to 2019 and were started on PCSK9i at our institution. Clinical, laboratory, and coronary angiography with intravascular ultrasound results were compared. Among 65 patients initiated on PCSK9i (48 for statin intolerance and 17 for refractory hyperlipidemia), the median time from transplant was 5.5 years (interquartile range [IQR], 2.8-9.9 years) with a median PCSK9 treatment duration of 1.6 years (IQR, 0.8-3.2 years) and 80% still on treatment. Evolocumab was used in 73.8%, alirocumab in 12.3%, and both in 13.8% owing to insurance coverage. All patients required prior authorization; initial denial occurred in 18.5% and 32.3% had denials in subsequent years. The median low-density lipoprotein cholesterol decreased from 130 mg/dL (IQR, 102-148 mg/dL) to 55 mg/dL (IQR, 35-74 mg/dL) after starting PCSK9i (P < .001), with 72% of patients achieving a low-density lipoprotein cholesterol of <70 mg/dL after treatment. There were also significant reductions of total cholesterol, non-high-density lipoprotein cholesterol, total/high-density lipoprotein cholesterol ratio, and triglycerides, with a modest increase in high-density lipoprotein cholesterol. These changes were durable at latest follow-up. In 33 patients with serial coronary angiography and intravascular ultrasound, PCSK9i were associated with stable coronary plaque thickness and lumen area. CONCLUSIONS: Among heart transplant recipients, PCSK9i are effective in lowering cholesterol levels and stabilizing coronary intimal hyperplasia with minimal side effects. Despite favorable effects, access and affordability remain a challenge.


Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Inhibidores de PCSK9 , LDL-Colesterol , Humanos , Receptores de Trasplantes
6.
Catheter Cardiovasc Interv ; 98(3): E436-E443, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33512085

RESUMEN

BACKGROUND: Monitored anesthesia care (MAC) has become more widely used during transcatheter aortic valve replacement (TAVR) to avoid the complications of general anesthesia (GA). METHODS: We included consecutive patients who underwent transfemoral-TAVR at our institution between January 2012 and April 2017. We compared outcomes with GA versus MAC. RESULTS: Of 998 patients, MAC was used in 43.9%. MAC was associated with shorter procedural time (96.9 ± 30.9 vs. 135 ± 64.6 mins; p < .001), fluoroscopy time (20.4 ± 8.9 vs. 29 ± 18.7 mins; p < .001), lower contrast volume (45.5 ± 27 vs. 60.4 ± 43 cc; p < .001), and decreased radiation exposure (12,869 ± 8,099 vs. 20,630 ± 16,276 cGy-cm2 ; p < .001). Patients who underwent MAC had a briefer median (IQR) intensive care unit stay [23.3 (21-24) vs. 23.4 (20.8-26) hrs; p < .001], and hospital stay [2 (2, 3) vs. 3 (2-6) days; p < .001], and were more frequently discharged to home (93.4% vs. 82.9%; p < .001). MAC was associated with lower mortality at 30 days (0.5% vs. 2.9%; log-rank p = .012; adjHR 0.22, 95% CI 0.06-0.82; p = .024), but not at 1 year (11.7% vs. 14.6%; log-rank p = .157) or 3 years (36.8% vs. 38.4%; log-rank p = 0.433). There were no differences in major adverse cardiac and cerebrovascular events (MACCE) at either 30 days (4.6% vs. 9.3%; log-rank p = .14) or 1 year (21.1% vs. 21.5%; log-rank p = .653). Similar findings were seen among patients who received newer-generation SAPIEN-3 valves. CONCLUSION: Utilizing MAC and omitting intraprocedural transesophageal echocardiography during TAVR seems to be more efficient without compromising safety. Better TAVR outcomes can be achieved with newer generation valves without needing GA.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Anestesia General/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Fluoroscopía , Humanos , Tiempo de Internación , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
7.
Catheter Cardiovasc Interv ; 98(1): E127-E138, 2021 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-33010100

RESUMEN

BACKGROUND: Baseline conduction abnormalities are known risk factors for permanent pacemaker (PPM) implantation after transcatheter aortic valve replacement (TAVR). We sought to determine the impact of baseline right bundle branch block (RBBB), left bundle branch block (LBBB), left anterior hemiblock (LAHB), first-degree atrioventricular block (AVB) and atrial fibrillation/flutter (AF) on TAVR outcomes. METHODS: Consecutive patients who underwent transfemoral TAVR with SAPIEN-3 (S3) were included. We excluded patients with prior PPM, nontransfemoral access or valve-in-valve. RESULTS: Among 886 patients, baseline RBBB was seen in 15.9%, LBBB in 6.3%, LAHB in 6.2%, first-degree AVB in 26.3% and AF in 37.5%. The rate of 30-day PPM was 10.1%. Baseline RBBB (OR 4.005; 95% CI 2.386-6.723; p < .001) and first-degree AVB (OR 1.847; 95% CI 1.133-3.009; p = .014) were independent predictors of 30 day PPM. LAHB also resulted in higher PPM rates but only in unadjusted analysis (21.8% vs. 9.4%; p = .003). Baseline LBBB and AF were associated with lower left ventricular ejection fraction (LVEF) at both baseline and 1 year after TAVR. However, Δ LVEF over time were noted to be similar with baseline LBBB (1.8% vs. 1.4%; p = .809) and AF (1.1% vs. 1.7%; p = .458). Moreover, baseline AF was also associated with higher stroke/transient ischemic attack (TIA) at 1 year (4.4% vs. 1.8%; p = .019), 1-year major adverse cardiac and cerebrovascular events (MACCE) (19.5% vs. 13.3%; p = .012) and 2 year mortality (23.5% vs. 15.2%; p = .016). None of the other baseline conduction defects affected long-term mortality or MACCE. CONCLUSION: In our S3 TAVR population, baseline RBBB and first-degree AVB predicted higher PPM risk. Prior LBBB and AF were associated with lower LVEF at both baseline and 1 year. Lastly, preexisting AF was associated with higher rates of mortality, stroke/TIA, and MACCE.


Asunto(s)
Estenosis de la Válvula Aórtica , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Factores de Riesgo , Volumen Sistólico , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Función Ventricular Izquierda
8.
Catheter Cardiovasc Interv ; 97(3): 529-539, 2021 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-32845036

RESUMEN

BACKGROUND: There is a paucity of data regarding the optimum timing of PCI in relation to TAVR. OBJECTIVE: We compared the major adverse cardiovascular and cerebrovascular events (MACCE) rates among patients who underwent percutaneous coronary intervention (PCI) before transcatheter aortic valve replacement (TAVR) with those who received PCI with/after TAVR. METHODS: In this multicenter study, we pooled all consecutive patients who underwent TAVR at three high volume centers. RESULTS: Among 3,982 patients who underwent TAVR, 327 (8%) patients underwent PCI within 1 year before TAVR, 38 (1%) had PCI the same day as TAVR and 15 (0.5%) had PCI within 2 months after TAVR. Overall, among patients who received both PCI and TAVR (n = 380), history of previous CABG (HR:0.501; p = .001), higher BMI at TAVR (HR:0.970; p = .038), and statin therapy after TAVR (HR:0.660, p = .037) were independently associated with lower MACCE while warfarin therapy after TAVR was associated with a higher risk of MACCE (HR:1.779, p = .017). Patients who received PCI within 1 year before TAVR had similar baseline demographics, STS scores, clinical risk factors when compared to patients receiving PCI with/after TAVR. Both groups were similar in PCI (Syntax Score, ACC/AHA lesion class) and TAVR (valve types, access) related variables. There were no significant differences in terms of MACCE (log rank p = .550), all-cause mortality (log rank p = .433), strokes (log rank p = .153), and repeat PCI (log rank p = .054) in patients who underwent PCI with/after TAVR when compared to patients who received PCI before TAVR. CONCLUSION: Among patients who underwent both PCI and TAVR, history of CABG, higher BMI, and statin therapy had lower, while those discharged on warfarin, had higher adverse event rates. Adverse events rates were similar regardless of timing of PCI.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Reemplazo de la Válvula Aórtica Transcatéter , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Enfermedad de la Arteria Coronaria/cirugía , Enfermedad de la Arteria Coronaria/terapia , Humanos , Intervención Coronaria Percutánea/efectos adversos , Sistema de Registros , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
9.
Catheter Cardiovasc Interv ; 96(7): 1522-1530, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32427426

RESUMEN

BACKGROUND: Transcatheter aortic valves are prone to acute recoil similar to the metal-based coronary stents. However, it is not clear if recoil remains a factor only after the initial valve deployment or also after post-dilation. METHODS: We conducted a retrospective observational study of patients who underwent transfemoral transcatheter aortic valve replacement (TAVR) with SAPIEN-3 valve. Acute recoil at the upper, central, and lower levels of the valve was calculated in both anteroposterior right anterior oblique (RAO) and lateral left anterior oblique (LAO) views after initial deployment as well as after post-dilation. The average recoil of the RAO and LAO views was also calculated and described as RAO/LAO. RESULTS: The acute recoil in the RAO/LAO views (mean ± SD) was 3.9 ± 1.1% after valve deployment in the whole study population (n = 257). Among the subset of patients who required post-dilation (n = 133), the mean acute recoil in the RAO/LAO views was found to be greater after initial valve deployment as compared with after post-dilation (3.8 ± 1.1% vs. 3.0 ± 0.9%; p < .001). Further, acute recoil was significantly greater in the RAO view than the LAO view and at the central level of the prosthesis as compared with the upper and lower levels. Those findings were consistent after initial deployment as well as after post-dilation. Clinical outcomes were similar between patients who required post-dilation compared to those who did not. In multivariable logistic regression analysis, only smaller valve cover index was found to be an independent predictor of 30-day mild or greater aortic regurgitation (OR 0.007; 95% CI 0.0001-0.707; p = .035). CONCLUSION: Acute elastic recoil of the SAPIEN-3 valve was significantly less after post-dilation as compared with after deployment. It was also greater when measured in the RAO view as compared with the LAO view. Furthermore, acute recoil was not homogenous across the height of the valve stent frame.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Valvuloplastia con Balón , Cateterismo Periférico , Arteria Femoral , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Valvuloplastia con Balón/efectos adversos , Cateterismo Periférico/efectos adversos , Elasticidad , Femenino , Humanos , Masculino , Diseño de Prótesis , Estudios Retrospectivos , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
10.
Catheter Cardiovasc Interv ; 96(2): 442-447, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-31713996

RESUMEN

INTRODUCTION: Percutaneous femoral access is the preferred access route for transcatheter aortic valve replacement (TAVR). The majority of experienced TAVR centers use two 6F Perclose ProGlide™ devices to close the primary vascular access site, deployed prior to upsizing sheath size with closure completed at the end of the case (the "preclose" approach). A strategy of utilizing a single Perclose device to preclose may have advantages including fewer complications, complexity, and cost, but the safety of this is unknown. This study examines in the safety and efficacy of using a single Perclose versus double Perclose for perclosure of large bore access during TAVR. METHODS: Patients undergoing Transfemoral (TF) TAVR from January 2014 to December 2017 within the Cleveland Clinic Aortic Valve Center were identified. A retrospective review of medical charts was conducted. Vascular complications were defined according to the VARC-2 criteria. RESULTS: A total of 740 patients were included; 487 (65.8%) received a single Perclose device while 253 (34.2%) received double Perclose devices. Baseline characteristics were similar with no differences between the single versus double Perclose groups, respectively. The access sheath size was similar in both groups with (14, 16, and 18 F) being the most common sizes utilized. Of the total 487 patients with single Perclose, 75.6% needed additional closure device (AngioSeal). With double Perclose strategy, additional closure device (AngioSeal) was used in 40.3% patients with 470 (63.5%) patients being successfully perclosed. Vascular complication rates including hematoma, stenosis requiring stenting, pseudoaneurysm, and other major vascular complications were similar between both groups. CONCLUSION: Single 6F ProGlide use for preclosure is a safe strategy for TF TAVR using the S3 valve. Additional closure device was not needed in almost one-quarter of the patients. When necessary, residual bleeding can be controlled with the AngioSeal Device at the end of the procedure. This single device preclose strategy can help to reduce the cost of TAVR procedure without increasing risk.


Asunto(s)
Cateterismo Periférico , Arteria Femoral , Hemorragia/prevención & control , Técnicas Hemostáticas/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter , Dispositivos de Cierre Vascular , Anciano , Anciano de 80 o más Años , Cateterismo Periférico/efectos adversos , Diseño de Equipo , Femenino , Hemorragia/etiología , Técnicas Hemostáticas/efectos adversos , Humanos , Masculino , Ohio , Punciones , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
11.
Catheter Cardiovasc Interv ; 94(4): 555-561, 2019 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-31429192

RESUMEN

OBJECTIVES: Determine the outcomes of polytetrafluoroethylene (PTFE) covered stents for coronary artery perforation (CAP) and coronary artery aneurysm (CAA). BACKGROUND: PTFE covered stents have been used for treatment of potentially life-threatening CAP and CAA. The short and long-term outcomes of the PTFE covered stent for CAP and CAA have not been well studied. METHODS: We performed a retrospective study of PTFE covered stents that were placed in the patients from 2003 to 2017. Short term outcomes included in-hospital mortality, pericardial effusion, cardiac tamponade, and length of stay. Long-term outcomes included target lesion revascularization (TLR), in-stent restenosis (ISR), and long-term mortality. RESULTS: Fifty-three PTFE covered stents were placed in 32 patients of which there were 24 patients with a CAP with a mean age of 75 ± 8 years. Two patients died in-hospital, with no additional deaths at 30 days. The rate of ISR was 25%, with estimated rates of TLR of 2.6% (3 years) and 17.8% (5 years). The median survival was 55.6 months, with survival at 10 years estimated to be 30.9%. Eight patients received a PTFE covered stent for CAA with a mean age of 59 ± 15 years with no in-hospital or 30-day mortality. Median follow-up of 49 months showed no evidence of TLR. The all-cause mortality was 12% at 1 year and 38% at 3 years. CONCLUSIONS: PTFE covered stents is an effective option in patients with CAP and CAA. The long-term outcomes may be related to the pathology of the disease rather than the stent itself.


Asunto(s)
Aneurisma Coronario/terapia , Vasos Coronarios/lesiones , Lesiones Cardíacas/terapia , Intervención Coronaria Percutánea/instrumentación , Politetrafluoroetileno , Stents , Anciano , Anciano de 80 o más Años , Aneurisma Coronario/diagnóstico por imagen , Aneurisma Coronario/mortalidad , Aneurisma Coronario/fisiopatología , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/fisiopatología , Femenino , Lesiones Cardíacas/diagnóstico por imagen , Lesiones Cardíacas/mortalidad , Lesiones Cardíacas/fisiopatología , Mortalidad Hospitalaria , Humanos , Masculino , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
12.
Artículo en Inglés | MEDLINE | ID: mdl-38836574

RESUMEN

Background: Increased left atrial pressure (LAP) has been associated with adverse outcomes after mitral transcatheter edge-to-edge repair (M-TEER). We sought to evaluate outcomes based on differences in post-procedural LAP measured after final clip deployment. Methods: We included consecutive patients who underwent M-TEER at our institution between 2014-2022 with LAP monitoring. Patients were stratified into 3 groups according to tertiles of post-TEER mean LAP. Outcomes were assessed using Kaplan-Meier analysis and Cox proportional hazard models. Results: We included 273 patients (mean age 76.8±10.8 years, 42.5% women, 78.4% Caucasian). The mean post-TEER LAP was 8.7±1.7 mmHg in tertile 1 (N=85), 14.4±1.6 mmHg in tertile 2 (N=95), and 21.9±3.8 mmHg in tertile 3 (N=93). In comparison with tertile 1, both tertiles 2 and 3 were associated with increased risk of all-cause mortality or heart failure hospitalization at 2 years (adjHR 2.27, 95% CI 1.25-4.12; and adjHR 3.00, 95% CI 1.59-5.64 respectively). Among patients with primary MR, higher LAP was associated with increased risk of 2-year all-cause mortality or heart failure hospitalization [tertile 2 vs. 1: adjHR 3.00, 95% CI 1.37-6.56; and tertile 3 vs. 1: adjHR 5.52, 95% CI 2.04-14.95). However, in patients with secondary MR, neither being in tertile 2 (adjHR 1.53; 95% CI 0.55-4.24), nor tertile 3 (adjHR 2.18; 95% CI 0.82-5.77) were associated with the composite outcome compared with tertile 1. Any degree of LAP reduction following M-TEER was associated with lower mortality or heart failure hospitalization compared with no LAP reduction (adjHR 0.59; 95% CI 0.39-0.88). Conclusions: Elevated LAP after M-TEER was associated with increased 2-year risk of mortality or heart failure hospitalization. Exploration of reasons for elevated LAP after M-TEER, and ways to lower it warrant further investigation.

13.
Methodist Debakey Cardiovasc J ; 19(1): 32-37, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37064497

RESUMEN

A 62-year-old male presented to the emergency department with acute viral bronchitis and worsening of his chronic dyspnea on exertion. Incidentally, a murmur was detected on physical examination. Extensive work-up, including coronary computed tomography angiography, revealed a rare combination and potential association between severe bicuspid aortic valve stenosis and coronary-pulmonary artery fistulas.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Enfermedad de la Arteria Coronaria , Fístula , Cardiopatías Congénitas , Masculino , Humanos , Persona de Mediana Edad , Arteria Pulmonar/diagnóstico por imagen , Constricción Patológica , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
14.
Am Heart J Plus ; 27: 100265, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36779177

RESUMEN

Background: Elevated cardiac troponin (cTn) levels in patients with COVID-19 has been associated with worse outcomes. Guidelines on best practices of those patients remain uncertain. Methods: We included patients with COVID-19 and cTn above the assay-specific upper limit of normal (ULN) enrolled in the American Heart Association's COVID-19 registry between March 2020-January 2021. Site-level variability in invasive coronary angiography, LVEF assessment, ICU utilization, and inpatient mortality were determined by calculating adjusted median odds ratio (MOR) using hierarchical logistic regression models. Temporal trends were assessed with Cochran-Armitage trend test. Results: Among 32,636 patients, we included 6234 (19.4 %) with cTn above ULN (age 68.7 ± 16.0 years, 56.5 % male, 51.5 % Caucasian), of whom 1365 (21.6 %) had ≥5-fold elevations. Across 55 sites, the median rate of invasive coronary angiography was 0.1 % with adjusted MOR 1.5(1.0,2.3), median LVEF assessment was 25.5 %, MOR 3.0(2.2,3.9), ICU utilization was 41.7 %, MOR 2.2(1.8,2.6), and mortality was 20.9 %, MOR 1.7(1.5,2.0). Over time, we noted a significant increase in invasive coronary angiography (p-trend = 0.001), and LVEF assessment (p-trend<0.001), and reduction in mortality (p-trend<0.001), without significant change in ICU admissions (p-trend = 0.08). Similar variability and temporal trends were seen among patients with ≥5-fold cTn elevation. Conclusions: The use of invasive coronary angiography among patients with COVID-19 and myocardial injury was very low during the early pandemic. We found moderate institutional variability in processes of care with an uptrend in invasive catheterization and LVEF assessment, and downtrend in mortality. Comparative effectiveness studies are needed to examine whether variability in care is associated with differences in outcomes.

15.
Am J Cardiol ; 192: 174-181, 2023 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-36812701

RESUMEN

The COVID-19 pandemic accelerated adaption of a telehealth care model. We studied the impact of telehealth on the management of atrial fibrillation (AF) by electrophysiology providers in a large, multisite clinic. Clinical outcomes, quality metrics, and indicators of clinical activity for patients with AF during the 10-week period of March 22, 2020 to May 30, 2020 were compared with those from the 10-week period of March 24, 2019 to June 1, 2019. There were 1946 unique patient visits for AF (1,040 in 2020 and 906 in 2019). During 120 days after each encounter, there was no difference in hospital admissions (11.7% vs 13.5%, p = 0.25) or emergency department visits (10.4% vs 12.5%, p = 0.15) in 2020 compared with 2019. There was a total of 31 deaths within 120 days, with similar rates in 2020 and 2019 (1.8% vs 1.3%, p = 0.38). There was no significant difference in quality metrics. The following clinical activities occurred less frequently in 2020 than in 2019: offering escalation of rhythm control (16.3% vs 23.3%, p <0.001), ambulatory monitoring (29.7% vs 51.7%, p <0.001), and electrocardiogram review for patients on antiarrhythmic drug therapy (22.1% vs 90.2%, p <0.001). Discussions about risk factor modification were more frequent in 2020 compared with 2019 (87.9% vs 74.8%, p <0.001). In conclusion, the use of telehealth in the outpatient management of AF was associated with similar clinical outcomes and quality metrics but differences in clinical activity compared with traditional ambulatory encounters. Longer-term outcomes warrant further investigation.


Asunto(s)
Fibrilación Atrial , COVID-19 , Telemedicina , Humanos , Fibrilación Atrial/tratamiento farmacológico , Pacientes Ambulatorios , Pandemias
16.
Am J Cardiol ; 197: 24-33, 2023 06 15.
Artículo en Inglés | MEDLINE | ID: mdl-37137251

RESUMEN

Data regarding the impact of pacing on outcomes after transcatheter aortic valve implantation (TAVI) is evolving especially with regards to pre-existing permanent pacemaker (PPM). We examined the impact of new and previous PPM on the clinical and hemodynamic outcomes after SAPIEN-3 TAVI. We included all consecutive patients who underwent transfemoral TAVI using SAPIEN-3 valve from 2015 to 2018 at our institution. Among 1,028 patients, 10.2% required a new PPM within 30 days, whereas 14% had a pre-existing PPM. The presence of either previous or new PPM had no impact on the 3-year mortality (log-rank p = 0.6) or 1-year major adverse cardiac and cerebrovascular events (log-rank p = 0.65). New PPM was associated with lower left ventricular (LV) ejection fraction (LVEF) at both 30 days (54.4 ± 11.3% vs 58.4 ± 10.1%, p = 0.001) and 1 year (54.2 ± 12% vs 59.1 ± 9.9%, p = 0.009) than no PPM. Similarly, previous PPM was associated with worse LVEF at 30 days (53.6 ± 12.3%, p <0.001) and 1 year (55.5 ± 12.1%, p = 0.006) than no PPM. Interestingly, new PPM was associated with lower 1-year mean gradient (11.4 ± 3.8 vs 12.6 ± 5.6 mm Hg, p = 0.04) and peak gradient (21.3 ± 6.5 vs 24.1 ± 10.4 mm Hg, p = 0.01), despite no baseline differences. Previous PPM was also associated with lower 1-year mean gradient (10.3 ± 4.4 mm Hg, p = 0.001) and peak gradient (19.4 ± 8 mm Hg, p <0.001) and higher Doppler velocity index (0.51 ± 0.12 vs 0.47 ± 0.13, p = 0.039). Moreover, 1-year LV end-systolic volume index was higher with new (23.2 ± 16.1 vs 20 ± 10.8 ml/m2, p = 0.038) and previous PPM (24.5 ± 19.7, p = 0.038) than no PPM. Previous PPM was associated with higher moderate-to-severe tricuspid regurgitation (35.3% vs 17.7%, p <0.001). There were no differences regarding the rest of the studied echocardiographic outcomes at 1 year. In conclusion, new and previous PPM did not affect 3-year mortality or 1-year major adverse cardiac and cerebrovascular events; however, they were associated with worse LVEF, higher 1-year LV end-systolic volume index, and lower mean and peak gradients on follow-up than no PPM.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/complicaciones , Ecocardiografía , Función Ventricular Izquierda , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
17.
J Leukoc Biol ; 112(3): 449-456, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35137444

RESUMEN

Few cytokines/growth modulating proteins are known to be chemoattractants for hematopoietic stem (HSC) and progenitor cells (HPC); stromal cell-derived factor 1α (SDF1α/CXCL12) being the most potent known such protein. DEK, a nuclear DNA-binding chromatin protein with hematopoietic cytokine-like activity, is a chemotactic factor attracting mature immune cells. Transwell migration assays were performed to test whether DEK serves as a chemotactic agent for HSC/HPC. DEK induced dose- and time-dependent directed migration of lineage negative (Lin- ) Sca-1+ c-Kit+ (LSK) bone marrow (BM) cells, HSCs and HPCs. Checkerboard assays demonstrated that DEK's activity was chemotactic (directed), not chemokinetic (random migration), in nature. DEK and SDF1α compete for HSC/HPC chemotaxis. Blocking CXCR2 with neutralizing antibodies or inhibiting Gαi protein signaling with Pertussis toxin pretreatment inhibited migration of LSK cells toward DEK. Thus, DEK is a novel and rare chemotactic agent for HSC/HPC acting in a direct or indirect CXCR2 and Gαi protein-coupled signaling-dependent manner.


Asunto(s)
Células Madre Hematopoyéticas , Proteínas Nucleares , Células de la Médula Ósea/metabolismo , Quimiotaxis , Proteínas de Unión al ADN/metabolismo , Células Madre Hematopoyéticas/metabolismo , Proteínas Nucleares/metabolismo , Receptores de Interleucina-8B/metabolismo
18.
Am J Prev Cardiol ; 9: 100301, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34977833

RESUMEN

OBJECTIVE: To conduct a comprehensive systematic review and meta-analysis to compare mortality and other clinical outcomes associated with chili pepper (CP) consumption versus no/rare consumption of CP. METHODS: A comprehensive search was performed using Ovid, Cochrane, Medline, EMBASE, and Scopus from inception till January 16, 2020. Observational studies and randomized controlled trials were included, while pediatric/animal studies, letters/case reports, reviews, abstracts, and book chapters were excluded. All-cause mortality was studied as the primary outcome. Cardiovascular mortality, cancer-related deaths and cerebrovascular accidents were studied as secondary outcomes. RESULTS: From 4729 studies, four studies met the inclusion criteria. Random effects pooled analysis showed that all-cause mortality among CP consumers was lower, compared to rare/non-consumers, with a hazard ratio (HR) of 0.87 [95% CI: 0.85-0.90; p<0.0001; I 2=1%]. HR for cardiovascular mortality was 0.83 [95% CI: 0.74-0.95; p = 0.005, I 2=66%] and for cancer-related mortality as 0.92 [95% CI: 0.87-0.97; p = 0.001; I 2=0%]. However, the HR for CVA was 0.78 [95% CI: 0.56-1.09; p = 0.26; I2 =60%]. The mode and amount of CP consumption varied across the studies, and data were insufficient to design an optimal strategy guiding its intake. CONCLUSION: Regular CP consumption was associated with significantly lower all-cause, cardiovascular, and cancer-related mortalities. However, based on current literature, it is difficult to derive a standardized approach to guide the optimal mode and amount of CP consumption. This warrants well-designed prospective studies to further investigate the potential health benefits of CP consumption.

19.
Transplant Proc ; 54(3): 663-670, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35256200

RESUMEN

BACKGROUND: Cardiovascular disease is the most common cause of death among kidney transplant (KT) recipients. Trials routinely exclude patients with end-stage renal disease when assessing the effect of coronary artery revascularization. We looked to compare long-term outcomes in patients who underwent percutaneous coronary intervention (PCI) before KT with those managed medically. METHODS: We identified all patients who underwent coronary artery catheterization before KT from January 2008 to November 2019 at the Cleveland Clinic. The primary endpoint was all-cause mortality. RESULTS: A total of 272 patients were included, of whom 52 (19.11%) underwent PCI, and the remaining 220 patients were managed medically. The median age in the PCI group was 57.4 years (interquartile range [IQR], 46.9-61.2 years), whereas it was 53.9 years (IQR, 44.6-61 years) in the group medically managed. Baseline characteristics including sex, race, hypertension, diabetes, smoking, and hyperlipidemia were comparable in both groups. The median time to KT was 2.4 years (IQR, 1-5 years) in the PCI group vs 1.2 years (IQR, 0.6-3.3 years) in the medically managed group (P = .001). Among patients who underwent PCI, 40.4% had single vessel disease and 59.6% had multivessel disease compared with 16.8% and 28.6%, respectively, in the medically managed group (P < .001). Overall, there was no difference in mortality in the PCI group compared with the medically managed group after 10 years of follow-up (P = .416). CONCLUSIONS: Patients with coronary artery disease can be safely treated with PCI before KT and have comparable outcomes to those who are managed medically.


Asunto(s)
Enfermedad de la Arteria Coronaria , Trasplante de Riñón , Intervención Coronaria Percutánea , Puente de Arteria Coronaria/efectos adversos , Enfermedad de la Arteria Coronaria/etiología , Humanos , Trasplante de Riñón/efectos adversos , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Factores de Riesgo , Resultado del Tratamiento
20.
Cureus ; 13(3): e13748, 2021 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-33842125

RESUMEN

Fragmented QRS (fQRS) is a marker of conduction block due to myocardial scar that presents in electrocardiography (ECG) as an additional one or more R wave (R') or notching in the S wave nadir in contiguous leads. However, fQRS description on premature ventricular contractions (PVCs) has not been previously described. We describe a case of a 67-year-old male with a past medical history of prediabetes, hypertension and coronary artery disease who presented after an ophthalmic procedure with asymptomatic PVCs and episodes of bigeminy. Initial ECG showed an isolated fQRS in V2. However, during PVCs significant extrasystoles fragmentation was seen in other coronary territories. Upon reviewing his most recent cardiac catheterization, it showed a 40% ostial and 70% distal left anterior descending stenosis with a mid-segment patent stent, 95% first diagonal stenosis and totally occluded proximal right coronary artery. Identification of diffuse fQRS known to be associated with myocardial scar, sustained arrhythmic events and sudden cardiac death, particularly when seen in the inferior leads, became extremely relevant in our patient. We noted that ejection fraction reduction from 52% to 34% on his last coronary intervention was crucial to decide if an implantable cardioverter-defibrillator would be needed. PVC fragmentation might be a new ECG marker that could uncover both scar and arrhythmia potential in patients at risk of adverse cardiac events.

SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda