RESUMEN
We report experimental evidence that multi-MeV protons accelerated in relativistic laser-plasma interactions are modulated by strong filamentary electromagnetic fields. Modulations are observed when a preplasma is developed on the rear side of a µm-scale solid-density hydrogen target. Under such conditions, electromagnetic fields are amplified by the relativistic electron Weibel instability and are maximized at the critical density region of the target. The analysis of the spatial profile of the protons indicates the generation of B>10 MG and E>0.1 MV/µm fields with a µm-scale wavelength. These results are in good agreement with three-dimensional particle-in-cell simulations and analytical estimates, which further confirm that this process is dominant for different target materials provided that a preplasma is formed on the rear side with scale length â³0.13λ_{0}sqrt[a_{0}]. These findings impose important constraints on the preplasma levels required for high-quality proton acceleration for multipurpose applications.
RESUMEN
Thomson backscattering of intense laser pulses from relativistic electrons not only allows for the generation of bright x-ray pulses but also for the investigation of the complex particle dynamics at the interaction point. For this purpose a complete spectral characterization of a Thomson source powered by a compact linear electron accelerator is performed with unprecedented angular and energy resolution. A rigorous statistical analysis comparing experimental data to 3D simulations enables, e.g., the extraction of the angular distribution of electrons with 1.5% accuracy and, in total, provides predictive capability for the future high brightness hard x-ray source PHOENIX (photon electron collider for narrow bandwidth intense x rays) and potential gamma-ray sources.
RESUMEN
The capacity to launch a strong shock wave in a compressed target in the presence of large preplasma has been investigated experimentally and numerically in a planar geometry. The experiment was performed on the LULI 2000 laser facility using one laser beam to compress the target and a second to launch the strong shock simulating the intensity spike in the shock ignition scheme. Thanks to a large set of diagnostics, it has been possible to compare accurately experimental results with 2D numerical simulations. A good agreement has been observed even if a more detailed study of the laser-plasma interaction for the spike is necessary in order to confirm that this scheme is a possible alternative for inertial confinement fusion.
RESUMEN
We present experimental and numerical results on intense-laser-pulse-produced fast electron beams transport through aluminum samples, either solid or compressed and heated by laser-induced planar shock propagation. Thanks to absolute K(α) yield measurements and its very good agreement with results from numerical simulations, we quantify the collisional and resistive fast electron stopping powers: for electron current densities of ≈ 8 × 10(10) A/cm(2) they reach 1.5 keV/µm and 0.8 keV/µm, respectively. For higher current densities up to 10(12)A/cm(2), numerical simulations show resistive and collisional energy losses at comparable levels. Analytical estimations predict the resistive stopping power will be kept on the level of 1 keV/µm for electron current densities of 10(14)A/cm(2), representative of the full-scale conditions in the fast ignition of inertially confined fusion targets.
RESUMEN
This Letter describes the first experimental demonstration of the guiding of a relativistic electron beam in a solid target using two colinear, relativistically intense, picosecond laser pulses. The first pulse creates a magnetic field that guides the higher-current, fast-electron beam generated by the second pulse. The effects of intensity ratio, delay, total energy, and intrinsic prepulse are examined. Thermal and Kα imaging show reduced emission size, increased peak emission, and increased total emission at delays of 4-6 ps, an intensity ratio of 10â¶1 (second:first) and a total energy of 186 J. In comparison to a single, high-contrast shot, the inferred fast-electron divergence is reduced by 2.7 times, while the fast-electron current density is increased by a factor of 1.8. The enhancements are reproduced with modeling and are shown to be due to the self-generation of magnetic fields. Such a scheme could be of considerable benefit to fast-ignition inertial fusion.
RESUMEN
We report on experimental investigations of proton acceleration from solid foils irradiated with PW-class laser-pulses, where highest proton cut-off energies were achieved for temporal pulse parameters that varied significantly from those of an ideally Fourier transform limited (FTL) pulse. Controlled spectral phase modulation of the driver laser by means of an acousto-optic programmable dispersive filter enabled us to manipulate the temporal shape of the last picoseconds around the main pulse and to study the effect on proton acceleration from thin foil targets. The results show that applying positive third order dispersion values to short pulses is favourable for proton acceleration and can lead to maximum energies of 70 MeV in target normal direction at 18 J laser energy for thin plastic foils, significantly enhancing the maximum energy compared to ideally compressed FTL pulses. The paper further proves the robustness and applicability of this enhancement effect for the use of different target materials and thicknesses as well as laser energy and temporal intensity contrast settings. We demonstrate that application relevant proton beam quality was reliably achieved over many months of operation with appropriate control of spectral phase and temporal contrast conditions using a state-of-the-art high-repetition rate PW laser system.
RESUMEN
Experimental measurements of magnetic fields generated in the cavity of a self-injecting laser-wakefield accelerator are presented. Faraday rotation is used to determine the existence of multimegagauss fields, constrained to a transverse dimension comparable to the plasma wavelength â¼λp and several λp longitudinally. The fields are generated rapidly and move with the driving laser. In our experiment, the appearance of the magnetic fields is correlated with the production of relativistic electrons, indicating that they are inherently tied to the growth and wave breaking of the nonlinear plasma wave. This evolution is confirmed by numerical simulations, showing that these measurements provide insight into the wakefield evolution with high spatial and temporal resolution.
RESUMEN
PURPOSE: In recent years, laser-based acceleration of charged particles has rapidly progressed and medical applications, e.g., in radiotherapy, might become feasible in the coming decade. Requirements are monoenergetic particle beams with long-term stable and reproducible properties as well as sufficient particle intensities and a controlled delivery of prescribed doses at the treatment site. Although conventional and laser-based particle accelerators will administer the same dose to the patient, their different time structures could result in different radiobiological properties. Therefore, the biological response to the ultrashort pulse durations and the resulting high peak dose rates of these particle beams have to be investigated. The technical prerequisites, i.e., a suitable cell irradiation setup and the precise dosimetric characterization of a laser-based particle accelerator, have to be realized in order to prepare systematic cell irradiation experiments. METHODS: The Jena titanium:sapphire laser system (JETI) was customized in preparation for cell irradiation experiments with laser-accelerated electrons. The delivered electron beam was optimized with regard to its spectrum, diameter, dose rate, and dose homogeneity. A custom-designed beam and dose monitoring system, consisting of a Roos ionization chamber, a Faraday cup, and EBT-1 dosimetry films, enables real-time monitoring of irradiation experiments and precise determination of the dose delivered to the cells. Finally, as proof-of-principle experiment cell samples were irradiated using this setup. RESULTS: Laser-accelerated electron beams, appropriate for in vitro radiobiological experiments, were generated with a laser shot frequency of 2.5 Hz and a pulse length of 80 fs. After laser acceleration in the helium gas jet, the electrons were filtered by a magnet, released from the vacuum target chamber, and propagated in air for a distance of 220 mm. Within this distance a lead collimator (aperture of 35 mm) was introduced, leading, along with the optimized setup, to a beam diameter of 35 mm, sufficient for the irradiation of common cell culture vessels. The corresponding maximum dose inhomogeneity over the beam spot was less than 10% for all irradiated samples. At cell position, the electrons posses a mean kinetic energy of 13.6 MeV, a bunch length of about 5 ps (FWHM), and a mean pulse dose of 1.6 mGy/bunch. Cross correlations show clear linear dependencies for the online recorded accumulated bunch charges, pulse doses, and pulse numbers on absolute doses determined with EBT-1 films. Hence, the established monitoring system is suitable for beam control and a dedicated dose delivery. Additionally, reasonable day-to-day stable and reproducible properties of the electron beam were achieved. CONCLUSIONS: Basic technical prerequisites for future cell irradiation experiments with ultrashort pulsed laser-accelerated electrons were established at the JETI laser system. The implemented online control system is suitable to compensate beam intensity fluctuations and the achieved accuracy of dose delivery to the cells is sufficient for radiobiological cell experiments. Hence, systematic in vitro cell irradiation experiments can be performed, being the first step toward clinical application of laser-accelerated particles. Further steps, including the transfer of the established methods to experiments on higher biological systems or to other laser-based particle accelerators, will be prepared.
Asunto(s)
Radiometría/métodos , Radioterapia/normas , Óxido de Aluminio/química , Animales , Electrones , Diseño de Equipo , Humanos , Rayos Láser , Aceleradores de Partículas , Radioterapia/métodos , Dosificación Radioterapéutica , Reproducibilidad de los Resultados , Titanio/químicaRESUMEN
In this paper, a scintillator-based online beam profile detector for the characterization of laser-driven proton beams is presented. Using a pixelated matrix with varying absorber thicknesses, the proton beam is spatially resolved in two dimensions and simultaneously energy-resolved. A thin plastic scintillator placed behind the absorber and read out by a CCD camera is used as the active detector material. The spatial detector resolution reaches down to â¼4 mm and the detector can resolve proton beam profiles for up to 9 proton threshold energies. With these detector design parameters, the spatial characteristics of the proton distribution and its cut-off energy can be analyzed online and on-shot under vacuum conditions. The paper discusses the detector design, its characterization and calibration at a conventional proton source, as well as the first detector application at a laser-driven proton source.
RESUMEN
Although bipolar jets are seen emerging from a wide variety of astrophysical systems, the issue of their formation and morphology beyond their launching is still under study. Our scaled laboratory experiments, representative of young stellar object outflows, reveal that stable and narrow collimation of the entire flow can result from the presence of a poloidal magnetic field whose strength is consistent with observations. The laboratory plasma becomes focused with an interior cavity. This gives rise to a standing conical shock from which the jet emerges. Following simulations of the process at the full astrophysical scale, we conclude that it can also explain recently discovered x-ray emission features observed in low-density regions at the base of protostellar jets, such as the well-studied jet HH 154.
RESUMEN
A photon detector suitable for the measurement of bremsstrahlung spectra generated in relativistically intense laser-solid interactions is described. The Monte Carlo techniques used to extract the fast electron spectrum and laser energy absorbed into forward-going fast electrons are detailed. A relativistically intense laser-solid experiment using frequency doubled laser light is used to demonstrate the effective operation of the detector. The experimental data were interpreted using the 3-spatial-dimension Monte Carlo code MCNPX [D. Pelowitz, MCNPX User's Manual Version 2.6.0, Los Alamos National Laboratory, 2008], and the fast electron temperature found to be 125 keV.
RESUMEN
The production of strongly magnetized laser plasmas, of interest for laboratory astrophysics and inertial confinement fusion studies, is presented. This is achieved by coupling a 16 kV pulse-power system. This is achieved by coupling a 16 kV pulse-power system, which generates a magnetic field by means of a split coil, with the ELFIE laser facility at Ecole Polytechnique. In order to influence the plasma dynamics in a significant manner, the system can generate, repetitively and without debris, high amplitude magnetic fields (40 T) in a manner compatible with a high-energy laser environment. A description of the system and preliminary results demonstrating the possibility to magnetically collimate plasma jets are given.
RESUMEN
We present the first observation of Thomson-backscattered light from laser-accelerated electrons. In a compact, all-optical setup, the "photon collider," a high-intensity laser pulse is focused into a pulsed He gas jet and accelerates electrons to relativistic energies. A counterpropagating laser probe pulse is scattered from these high-energy electrons, and the backscattered x-ray photons are spectrally analyzed. This experiment demonstrates a novel source of directed ultrashort x-ray pulses and additionally allows for time-resolved spectroscopy of the laser acceleration of electrons.