Resultados 1 - 20 de 31
Filtrar
1.
Brain ; 145(10): 3558-3570, 2022 10 21.
Artículo en Inglés | MEDLINE | ID: mdl-36270003

RESUMEN

Alzheimer's disease is neuropathologically characterized by the deposition of the amyloid ß-peptide (Aß) as amyloid plaques. Aß plaque pathology starts in the neocortex before it propagates into further brain regions. Moreover, Aß aggregates undergo maturation indicated by the occurrence of post-translational modifications. Here, we show that propagation of Aß plaques is led by presumably non-modified Aß followed by Aß aggregate maturation. This sequence was seen neuropathologically in human brains and in amyloid precursor protein transgenic mice receiving intracerebral injections of human brain homogenates from cases varying in Aß phase, Aß load and Aß maturation stage. The speed of propagation after seeding in mice was best related to the Aß phase of the donor, the progression speed of maturation to the stage of Aß aggregate maturation. Thus, different forms of Aß can trigger propagation/maturation of Aß aggregates, which may explain the lack of success when therapeutically targeting only specific forms of Aß.


Asunto(s)
Enfermedad de Alzheimer , Péptidos beta-Amiloides , Animales , Humanos , Ratones , Péptidos beta-Amiloides/metabolismo , Enfermedad de Alzheimer/patología , Precursor de Proteína beta-Amiloide/genética , Precursor de Proteína beta-Amiloide/metabolismo , Placa Amiloide/metabolismo , Ratones Transgénicos , Encéfalo/patología , Modelos Animales de Enfermedad
2.
Prev Med ; 105: 271-274, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28963008

RESUMEN

Despite a body of evidence on the relationship between neighborhood socioeconomic disadvantage and body mass index (BMI), few studies have examined this relationship over time among ageing populations. This study examined associations between level of neighborhood socioeconomic disadvantage and the rate of change in BMI over time. The sample included 11,035 participants aged between 40 and 65years at baseline from the HABITAT study, residing in 200 neighborhoods in Brisbane, Australia. Data were collected biennially over four waves from 2007 to 2013. Self-reported height and weight were used to calculate BMI, while neighborhood disadvantage was measured using a census-based composite index. All models were adjusted for age, education, occupation, and household income. Analyses were conducted using multilevel linear regression models. BMI increased over time at a rate of 0.08kg/m2 (95% CI 0.02, 0.13) and 0.17kg/m2 (95% CI 0.11, 0.29) per wave for men and women respectively. Both men and women residing in the most disadvantaged neighborhoods had a higher average BMI than their counterparts living in the least disadvantaged neighborhoods. There were no evident differences in the rate of BMI change over time by level of neighborhood disadvantage. The findings suggest that by mid-older age, the influence of neighborhood socioeconomic conditions over time on BMI may have already played out. Future research should endeavor to identify the genesis of neighborhood socioeconomic inequalities in BMI, the determinants of these inequalities, and then suitable approaches to intervening.


Asunto(s)
Índice de Masa Corporal , Características de la Residencia/estadística & datos numéricos , Factores Socioeconómicos , Adulto , Australia , Femenino , Estado de Salud , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Factores de Tiempo
3.
Clin Chem Lab Med ; 52(7): 1079-86, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24681433

RESUMEN

BACKGROUND: Point-of-care testing (POCT) of blood glucose (BG) is performed by medical personnel in clinical settings as well as by patients themselves for self-monitoring of blood glucose (SMBG) at home. We investigated if a system mainly intended for SMBG by people with diabetes, but also suitable for BG measurements by medical personnel, can achieve measurement accuracy on capillary blood samples comparable with professional-use POCT systems. METHODS: System accuracy was evaluated under standardised conditions, following the ISO standard 15197:2003. For each system (one SMBG system with three test strip lots and six professional-use systems), measurement results from capillary blood samples of 100 subjects were compared with a standardised laboratory glucose oxidase method (YSI 2300 glucose analyser). RESULTS: The seven evaluated systems showed 99.5% or 100% of the measurement results within the required system accuracy limits of ISO 15197:2003 (±0.83 mmol/L at BG concentrations <4.2 mmol/L and ±20% at BG concentrations ≥4.2 mmol/L). Applying the more stringent requirements of the revision ISO 15197:2013, the systems showed between 99% and 100% of the measurement results within the accuracy limits (±0.83 mmol/L at BG concentrations <5.55 mmol/L and ±15% at BG concentrations ≥5.55 mmol/L) and between 82% and 98% when even more restrictive limits were applied (±0.56 mmol/L and ±10%, respectively). CONCLUSIONS: Data from this study, which focused on system accuracy, suggest that SMBG systems can achieve system accuracy that is comparable with professional-use systems when measurements are performed on capillary blood samples by trained personnel in a standardised and controlled setting.


Asunto(s)
Glucemia/análisis , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 2/diagnóstico , Sistemas de Atención de Punto , Interfaz Usuario-Computador , Adolescente , Adulto , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 2/sangre , Humanos , Sistemas de Atención de Punto/normas , Adulto Joven
4.
Macromol Rapid Commun ; 32(11): 807-12, 2011 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-21469243

RESUMEN

Shining a light on click chemistry: The use of UV-radiation as trigger signal provides a facile means to obtain spatial and temporal control over polymer conjugation reactions in addition to providing a further means of achieving orthogonality in click transformations. In the current contribution, UV-radiation was employed to induce a highly efficient Diels-Alder conjugation of polymeric building blocks via the photo-induced in situ formation of highly reactive cis-dienes from a 2-methylbenzophenone precursor.


Asunto(s)
Benzofenonas/química , Química Clic , Sustancias Macromoleculares/síntesis química , Polímeros/síntesis química , Rayos Ultravioleta , Sustancias Macromoleculares/química , Peso Molecular , Compuestos Organometálicos/química , Procesos Fotoquímicos , Polimerizacion , Polímeros/química , Espectrometría de Masa por Ionización de Electrospray , Temperatura
5.
Cells ; 10(12)2021 11 30.
Artículo en Inglés | MEDLINE | ID: mdl-34943878

RESUMEN

Subtype-specific human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) are promising tools, e.g., to assess the potential of drugs to cause chronotropic effects (nodal hiPSC-CMs), atrial fibrillation (atrial hiPSC-CMs), or ventricular arrhythmias (ventricular hiPSC-CMs). We used single-cell patch-clamp reverse transcriptase-quantitative polymerase chain reaction to clarify the composition of the iCell cardiomyocyte population (Fujifilm Cellular Dynamics, Madison, WI, USA) and to compare it with atrial and ventricular Pluricytes (Ncardia, Charleroi, Belgium) and primary human atrial and ventricular cardiomyocytes. The comparison of beating and non-beating iCell cardiomyocytes did not support the presence of true nodal, atrial, and ventricular cells in this hiPSC-CM population. The comparison of atrial and ventricular Pluricytes with primary human cardiomyocytes showed trends, indicating the potential to derive more subtype-specific hiPSC-CM models using appropriate differentiation protocols. Nevertheless, the single-cell phenotypes of the majority of the hiPSC-CMs showed a combination of attributes which may be interpreted as a mixture of traits of adult cardiomyocyte subtypes: (i) nodal: spontaneous action potentials and high HCN4 expression and (ii) non-nodal: prominent INa-driven fast inward current and high expression of SCN5A. This may hamper the interpretation of the drug effects on parameters depending on a combination of ionic currents, such as beat rate. However, the proven expression of specific ion channels supports the evaluation of the drug effects on ionic currents in a more realistic cardiomyocyte environment than in recombinant non-cardiomyocyte systems.


Asunto(s)
Fenómenos Electrofisiológicos , Células Madre Pluripotentes Inducidas/metabolismo , Canales Iónicos/metabolismo , Miocitos Cardíacos/metabolismo , Células Cultivadas , Regulación de la Expresión Génica , Humanos , Activación del Canal Iónico , Miocitos Cardíacos/citología , Análisis de la Célula Individual
6.
J Pharmacol Toxicol Methods ; 106: 106915, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32871229

RESUMEN

INTRODUCTION: Human induced pluripotent stem cell (hiPSC)-derived cardiomyocytes are being evaluated for their use in pharmacological and toxicological testing, particularly for electrophysiological side effects. However, little is known about the composition of the commercially available iCell cardiomyocyte (Fuijifilm Cellular Dynamics) cultures and the transcriptomic phenotype of individual cells. METHODS: We characterized iCell cardiomyocytes (assumed to be a mixture of nodal-, atrial-, and ventricular-like cardiomyocytes together with potential residual non-myocytes) using bulk RNA-sequencing, followed by investigation of cellular heterogeneity using two different single-cell RNA-sequencing platforms. RESULTS: Bulk RNA-sequencing identified key cardiac markers (TNNT2, MYL7) as well as fibroblast associated genes (P4HB, VIM), and cardiac ion channels in the iCell cardiomyocyte culture. High-resolution single cell RNA-sequencing demonstrated that both, cardiac and fibroblast-related genes were co-expressed throughout the cell population. This approach resolved two cell clusters within iCell cardiomyocytes. Interestingly, these clusters could not be associated with known cardiac subtypes. However, transcripts of ion channels potentially useful as functional markers for cardiac subtypes were below the detection limits of the single-cell approaches used. Instead, one cluster (10.8% of the cells) is defined by co-expression of cardiac and cell cycle-related genes (e.g. TOP2A). Incorporation of bromodeoxyuridine further confirmed the capability of iCell cardiomyocytes to enter cell cycle. DISCUSSION: The co-expression of cardiac related genes with cell cycle or fibroblast related genes may be interpreted either as aberrant or as an immature feature. However, this excludes the presence of a non-cardiomyocyte sub-population and indicates that some cardiomyocytes themselves enter cell cycle.


Asunto(s)
Miocitos Cardíacos/fisiología , RNA-Seq/métodos , Análisis de la Célula Individual/métodos , Biomarcadores/análisis , Ciclo Celular/genética , Diferenciación Celular/genética , Línea Celular , Separación Celular , Evaluación Preclínica de Medicamentos/métodos , Fibroblastos/fisiología , Humanos , Células Madre Pluripotentes Inducidas/fisiología , Transcriptoma/fisiología
7.
BMC Cancer ; 9: 308, 2009 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-19725960

RESUMEN

BACKGROUND: Although Temozolomide is effective against glioblastoma, the prognosis remains dismal and new regimens with synergistic activity are sought for. METHODS: In this phase-I/II trial, pegylated liposomal doxorubicin (Caelyx, PEG-Dox) and prolonged administration of Temozolomide in addition to radiotherapy was investigated in 63 patients with newly diagnosed glioblastoma. In phase-I, PEG-Dox was administered in a 3-by-3 dose-escalation regimen. In phase-II, 20 mg/m2 PEG-Dox was given once prior to radiotherapy and on days 1 and 15 of each 28-day cycle starting 4 weeks after radiotherapy. Temozolomide was given in a dose of 75 mg/m2 daily during radiotherapy (60 Gy) and 150-200 mg/m2 on days 1-5 of each 28-day cycle for 12 cycles or until disease progression. RESULTS: The toxicity of the combination of PEG-Dox, prolonged administration of Temozolomide, and radiotherapy was tolerable. The progression free survival after 12 months (PFS-12) was 30.2%, the median overall survival was 17.6 months in all patients including the ones from Phase-I. None of the endpoints differed significantly from the EORTC26981/NCIC-CE.3 data in a post-hoc statistical comparison. CONCLUSION: Together, the investigated combination is tolerable and feasible. Neither the addition of PEG-Dox nor the prolonged administration of Temozolomide resulted in a meaningful improvement of the patient's outcome as compared to the EORTC26981/NCIC-CE.3 data.


Asunto(s)
Neoplasias del Sistema Nervioso Central/tratamiento farmacológico , Neoplasias del Sistema Nervioso Central/radioterapia , Dacarbazina/análogos & derivados , Doxorrubicina/análogos & derivados , Glioblastoma/tratamiento farmacológico , Glioblastoma/radioterapia , Polietilenglicoles/administración & dosificación , Adolescente , Adulto , Anciano , Neoplasias del Sistema Nervioso Central/diagnóstico , Neoplasias del Sistema Nervioso Central/mortalidad , Terapia Combinada , Dacarbazina/administración & dosificación , Dacarbazina/efectos adversos , Doxorrubicina/administración & dosificación , Doxorrubicina/efectos adversos , Esquema de Medicación , Quimioterapia Combinada , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos , Femenino , Glioblastoma/diagnóstico , Glioblastoma/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Polietilenglicoles/efectos adversos , Temozolomida , Adulto Joven
8.
Physiol Behav ; 96(3): 428-33, 2009 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-19061908

RESUMEN

How may perception, maternal motivation and behavior of female mammals change during different phases of their estrous cycle? Here, we show effects of estrous cycle phase on the perception of acoustic meaning and maternal behavior in virgin house mice (Mus musculus) during contact with young for which they were co-caring together with the mother. Cycling females in diestrus, proestrus, estrus or metestrus responded to mouse pup wriggling calls and two synthesized call models when they were in a "nursing" position on the pups. Independent of the phase of their estrous cycle, the virgin females' response rates to naturally vocalized calls and the rates of their spontaneous maternal behavior were about half of those of mothers in the same behavioral setting. This suggests that the maternal motivation of virgin females is generally half of that of mothers but rather constant during the estrous cycle. The response rates to the call models changed during the females' estrous cycles. During diestrus and proestrus (not in estrus and metestrus) they perceived acoustic differences between the call models and responded with different rates of maternal behavior. In estrus, they showed maternal behavior at a high rate and preferred the call models similar to the natural calls. In metestrus, response rates to the synthesized call models were low, so that only natural calls (not call models) released maternal behavior at a high rate. These behavioral data from house mice show remarkable similarities with perceptual plasticity and emotional and mood-dependent reactivity during the menstrual cycle in women.


Asunto(s)
Percepción Auditiva/fisiología , Ciclo Estral/fisiología , Conducta Materna/fisiología , Paridad/fisiología , Vocalización Animal/fisiología , Adaptación Psicológica , Animales , Comprensión , Femenino , Ratones , Embarazo , Espectrografía del Sonido
9.
Prev Med Rep ; 14: 100844, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30997324

RESUMEN

This study examined associations between neighborhood disadvantage and body mass index (BMI), and tested whether this differed by level of individual socioeconomic position (SEP). Data were from 9953 residents living in 200 neighborhoods in Brisbane, Australia in 2007. Multilevel linear regression analyses were undertaken by gender to determine associations between neighborhood disadvantage, individual SEP (education, occupation and household income) and BMI (from self-reported height and weight); with cross-level interactions testing whether the relationship between neighborhood disadvantage and BMI differed by level of individual SEP. Both men (Quintile 4, where Quintile 5 is the most disadvantaged ß = 0.66 95%CI 0.20, 1.12) and women (Quintile 5 ß = 1.32 95%CI 0.76, 1.87) from more disadvantaged neighborhoods had a higher BMI. BMI was significantly higher for those with lower educational attainment (men ß = 0.71 95%CI 0.36, 1.07 and women ß = 1.66 95%CI 0.78, 1.54), and significantly lower for those in blue collar occupations (men ß = -0.67 95%CI -1.09, -0.25 and women ß = -0.71 95%CI -1.40, -0.01). Among men, those with a lower income had a significantly lower BMI, while the opposite was found among women. None of the interaction models had a significantly better fit than the random intercept models. The relationship between neighborhood disadvantage and BMI did not differ by level of education, occupation, or household income. This suggests that individual SEP is unlikely to be an effector modifier of the relationship between neighborhood disadvantage and BMI. Further research is required to assist policy-makers to make more informed decisions about where to intervene to counteract BMI-inequalities.

10.
J Diabetes Sci Technol ; 9(4): 885-94, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25872965

RESUMEN

In the European Union (EU), the ISO (International Organization for Standardization) 15197 standard is applicable for the evaluation of systems for self-monitoring of blood glucose (SMBG) before the market approval. In 2013, a revised version of this standard was published. Relevant revisions in the analytical performance requirements are the inclusion of the evaluation of influence quantities, for example, hematocrit, and some changes in the testing procedures for measurement precision and system accuracy evaluation, for example, number of test strip lots. Regarding system accuracy evaluation, the most important change is the inclusion of more stringent accuracy criteria. In 2014, the Food and Drug Administration (FDA) in the United States published their own guidance document for the premarket evaluation of SMBG systems with even more stringent system accuracy criteria than stipulated by ISO 15197:2013. The establishment of strict accuracy criteria applicable for the premarket evaluation is a possible approach to further improve the measurement quality of SMBG systems. However, the system accuracy testing procedure is quite complex, and some critical aspects, for example, systematic measurement difference between the reference measurement procedure and a higher-order procedure, may potentially limit the apparent accuracy of a given system. Therefore, the implementation of a harmonized reference measurement procedure for which traceability to standards of higher order is verified through an unbroken, documented chain of calibrations is desirable. In addition, the establishment of regular and standardized post-marketing evaluations of distributed test strip lots should be considered as an approach toward an improved measurement quality of available SMBG systems.


Asunto(s)
Automonitorización de la Glucosa Sanguínea/instrumentación , Automonitorización de la Glucosa Sanguínea/normas , Glucemia/análisis , Diabetes Mellitus/sangre , Automonitorización de la Glucosa Sanguínea/métodos , Europa (Continente) , Guías como Asunto , Hematócrito , Humanos , Hipoglucemia/diagnóstico , Reproducibilidad de los Resultados , Estados Unidos , United States Food and Drug Administration
11.
J Diabetes Sci Technol ; 9(5): 1041-50, 2015 Apr 14.
Artículo en Inglés | MEDLINE | ID: mdl-25872967

RESUMEN

BACKGROUND: The standard ISO (International Organization for Standardization) 15197 is widely accepted for the accuracy evaluation of systems for self-monitoring of blood glucose (SMBG). Accuracy evaluation was performed for 4 SMBG systems (Accu-Chek Aviva, ContourXT, GlucoCheck XL, GlucoMen LX PLUS) with 3 test strip lots each. To investigate a possible impact of the comparison method on system accuracy data, 2 different established methods were used. METHODS: The evaluation was performed in a standardized manner following test procedures described in ISO 15197:2003 (section 7.3). System accuracy was assessed by applying ISO 15197:2003 and in addition ISO 15197:2013 criteria (section 6.3.3). For each system, comparison measurements were performed with a glucose oxidase (YSI 2300 STAT Plus glucose analyzer) and a hexokinase (cobas c111) method. RESULTS: All 4 systems fulfilled the accuracy requirements of ISO 15197:2003 with the tested lots. More stringent accuracy criteria of ISO 15197:2013 were fulfilled by 3 systems (Accu-Chek Aviva, ContourXT, GlucoMen LX PLUS) when compared to the manufacturer's comparison method and by 2 systems (Accu-Chek Aviva, ContourXT) when compared to the alternative comparison method. All systems showed lot-to-lot variability to a certain degree; 2 systems (Accu-Chek Aviva, ContourXT), however, showed only minimal differences in relative bias between the 3 evaluated lots. CONCLUSIONS: In this study, all 4 systems complied with the evaluated test strip lots with accuracy criteria of ISO 15197:2003. Applying ISO 15197:2013 accuracy limits, differences in the accuracy of the tested systems were observed, also demonstrating that the applied comparison method/system and the lot-to-lot variability can have a decisive influence on accuracy data obtained for a SMBG system.


Asunto(s)
Automonitorización de la Glucosa Sanguínea/instrumentación , Glucemia/análisis , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 2/sangre , Glucosa Oxidasa , Hexoquinasa , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Humanos , Ensayo de Materiales , Persona de Mediana Edad , Estándares de Referencia , Adulto Joven
12.
J Diabetes Sci Technol ; 10(2): 343-9, 2015 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-26452634

RESUMEN

BACKGROUND: The measurement accuracy of systems for self-monitoring of blood glucose (SMBG) is usually analyzed by a method comparison in which the analysis results are displayed using difference plots or similar graphs. However, such plots become difficult to comprehend as the number of data points displayed increases. This article introduces a new approach, the rectangle target plot (RTP), which aims to provide a simplified and comprehensible visualization of accuracy data. METHODS: The RTP is based on ISO 15197 accuracy evaluations of SMBG systems. Two-sided tolerance intervals for normally distributed data are calculated for absolute and relative differences at glucose concentrations <100 mg/dL and ≥100 mg/dL. These tolerance intervals provide an estimator of where a 90% proportion of results is found with a confidence level of 95%. RESULTS: Plotting these tolerance intervals generates a rectangle whose center indicates the systematic measurement difference of the investigated system relative to the comparison method. The size of the rectangle depends on the measurement variability. CONCLUSIONS: The RTP provides a means of displaying measurement accuracy data in a simple and comprehensible manner. The visualization is simplified by reducing the displayed information from typically 200 data points to just 1 rectangle. Furthermore, this allows data for several systems or several lots from 1 system to be displayed clearly and concisely in a single graph.


Asunto(s)
Algoritmos , Automonitorización de la Glucosa Sanguínea , Glucemia/análisis , Humanos , Estándares de Referencia , Reproducibilidad de los Resultados
13.
Diabetes Technol Ther ; 17(9): 625-34, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26062008

RESUMEN

INTRODUCTION: Systems for self-monitoring of blood glucose (SMBG) are expected to be accurate enough to provide reliable measurement results. Especially in the low glycemic range, adequate therapeutic decisions based on reliable results can alleviate complications associated with hypoglycemia. MATERIALS AND METHODS: The accuracy of four SMBG systems (system 1 was the ACCU-CHEK(®) Aviva [Roche Diagnostics GmbH, Mannheim, Germany], system 2 was the Contour(®) XT [Bayer Consumer Care AG, Basel, Switzerland], system 3 was the GlucoCheck XL [aktivmed GmbH, Augsberg, Germany], and system 4 was the GlucoMen(®) LX PLUS [A. Menarini Diagnostics S.r.l., Florence, Italy]) with three test-strip lots each was evaluated by calculating mean absolute relative differences (MARDs). Two datasets were evaluated: (1) 100 samples with blood glucose concentrations <70 mg/dL and (2) 100 samples distributed following International Organization for Standardization (ISO) standard 15197. Each sample was measured twice with each test-strip lot of each SMBG system. Comparison measurement results were obtained with a glucose oxidase method and a hexokinase method, both traceable according to ISO 17511. Analysis of variance of the MARD between the SMBG system and the comparison method was performed. RESULTS: MARD values ranged from 4.4% to 13.4% (<70 mg/dL) and 4.8% to 8.9% (ISO 15197-distributed) and differed significantly, with systems 1 and 2 showing lower MARDs than systems 3 and 4. MARD values deviated by up to 2.5% (corresponding to a relative deviation of approximately 40%) between the two comparison methods. CONCLUSIONS: The investigated SMBG systems showed a significant variation of accuracy (measured by MARD), especially with higher MARD values in the low glycemic range. The selected comparison method had an impact on the MARD and therefore on the apparent accuracy of the SMBG systems. Sufficient measurement accuracy in the low glycemic range is required to enable users to react adequately to hypoglycemia.


Asunto(s)
Automonitorización de la Glucosa Sanguínea/instrumentación , Automonitorización de la Glucosa Sanguínea/normas , Glucemia/análisis , Diabetes Mellitus/sangre , Hipoglucemia/sangre , Análisis de Varianza , Humanos , Estándares de Referencia , Reproducibilidad de los Resultados
14.
Diabetes Technol Ther ; 17(9): 635-48, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26110670

RESUMEN

BACKGROUND: Adherence to established standards (e.g., International Organization for Standardization [ISO] 15197) is important to ensure comparable and sufficient accuracy of systems for self-monitoring of blood glucose (SMBG). Accuracy evaluation was performed for different SMBG systems available in Europe with three reagent lots each. MATERIALS AND METHODS: Test procedures followed the recently published revision ISO 15197:2013. Comparison measurements were performed with a glucose oxidase (YSI 2300 STAT Plus™ glucose analyzer; YSI Inc., Yellow Springs, OH) and a hexokinase (cobas Integra(®) 400 Plus analyzer; Roche Instrument Center, Rotkreuz, Switzerland) method. Compliance with ISO 15197:2013 accuracy criteria was determined by calculating the percentage of results within ±15% or within ±0.83 mmol/L of the comparison measurement results for glucose concentrations at and above or below 5.55 mmol/L, respectively, and by calculating the percentage of results within consensus error grid Zones A and B. RESULTS: Seven systems showed with all three tested lots that 95-100% of the results were within the accuracy limits of ISO 15197:2013 and that 100% of results were within consensus error grid Zones A and B, irrespective of the comparison method used. Regarding results of individual lots, slight differences between the glucose oxidase method and the hexokinase method were found. Accuracy criteria of ISO 15197:2003 (±20% for concentrations ≥4.2 mmol/L and±0.83 mmol/L for concentrations <4.2 mmol/L) were fulfilled by eight systems with all three lots and by one system with two lots. CONCLUSIONS: In this study, seven systems complied with the accuracy criteria of ISO 15197:2013. The results also indicate that the comparison measurement method/system is important, as it may have a considerable impact on accuracy data obtained for a system.


Asunto(s)
Automonitorización de la Glucosa Sanguínea/instrumentación , Glucemia/análisis , Diabetes Mellitus/sangre , Automonitorización de la Glucosa Sanguínea/normas , Glucosa Oxidasa/análisis , Hexoquinasa/análisis , Humanos , Tiras Reactivas , Estándares de Referencia , Reproducibilidad de los Resultados
15.
Diabetes Technol Ther ; 16(3): 156-65, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24205977

RESUMEN

BACKGROUND: The partial pressure of oxygen (pO2) in blood samples can affect glucose measurements with oxygen-sensitive systems. In this study, we assessed the influence of different pO2 levels on blood glucose (BG) measurements with five glucose oxidase (GOD) systems and one glucose dehydrogenase (GDH) system. All selected GOD systems were indicated by the manufacturers to be sensitive to increased oxygen content of the blood sample. MATERIALS AND METHODS: Venous blood samples of 16 subjects (eight women, eight men; mean age, 52 years; three with type 1 diabetes, four with type 2 diabetes, and nine without diabetes) were collected. Aliquots of each sample were adjusted to the following pO2 values: ≤45 mm Hg, approximately 70 mm Hg, and ≥150 mm Hg. For each system, five consecutive measurements on each sample were performed using the same test strip lot. Relative differences between the mean BG value at a pO2 level of approximately 70 mm Hg, which was considered to be similar to pO2 values in capillary blood samples, and the mean BG value at pO2 levels ≤45 mm Hg and ≥150 mm Hg were calculated. RESULTS: The GOD systems showed mean relative differences between 11.8% and 44.5% at pO2 values ≤45 mm Hg and between -14.6% and -21.2% at pO2 values ≥150 mm Hg. For the GDH system, the mean relative differences were -0.3% and -0.2% at pO2 values ≤45 mm Hg and ≥150 mm Hg, respectively. CONCLUSIONS: The magnitude of the pO2 impact on BG measurements seems to vary among the tested oxygen-sensitive GOD systems. The pO2 range in which oxygen-sensitive systems operate well should be provided in the product information.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Glucemia/metabolismo , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 2/sangre , Glucosa 1-Deshidrogenasa/sangre , Glucosa Oxidasa/sangre , Oxígeno/sangre , Técnicas Biosensibles , Análisis de los Gases de la Sangre , Automonitorización de la Glucosa Sanguínea/instrumentación , Diabetes Mellitus Tipo 1/fisiopatología , Diabetes Mellitus Tipo 2/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico , Presión Parcial , Reproducibilidad de los Resultados
16.
Diabetes Technol Ther ; 16(2): 113-22, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24205978

RESUMEN

BACKGROUND: Systems for self-monitoring of blood glucose (SMBG) have to provide accurate and reproducible blood glucose (BG) values in order to ensure adequate therapeutic decisions by people with diabetes. MATERIALS AND METHODS: Twelve SMBG systems were compared in a standardized manner under controlled laboratory conditions: nine systems were available on the German market and were purchased from a local pharmacy, and three systems were obtained from the manufacturer (two systems were available on the U.S. market, and one system was not yet introduced to the German market). System accuracy was evaluated following DIN EN ISO (International Organization for Standardization) 15197:2003. In addition, measurement reproducibility was assessed following a modified TNO (Netherlands Organization for Applied Scientific Research) procedure. Comparison measurements were performed with either the glucose oxidase method (YSI 2300 STAT Plus™ glucose analyzer; YSI Life Sciences, Yellow Springs, OH) or the hexokinase method (cobas(®) c111; Roche Diagnostics GmbH, Mannheim, Germany) according to the manufacturer's measurement procedure. RESULTS: The 12 evaluated systems showed between 71.5% and 100% of the measurement results within the required system accuracy limits. Ten systems fulfilled with the evaluated test strip lot minimum accuracy requirements specified by DIN EN ISO 15197:2003. In addition, accuracy limits of the recently published revision ISO 15197:2013 were applied and showed between 54.5% and 100% of the systems' measurement results within the required accuracy limits. Regarding measurement reproducibility, each of the 12 tested systems met the applied performance criteria. CONCLUSIONS: In summary, 83% of the systems fulfilled with the evaluated test strip lot minimum system accuracy requirements of DIN EN ISO 15197:2003. Each of the tested systems showed acceptable measurement reproducibility. In order to ensure sufficient measurement quality of each distributed test strip lot, regular evaluations are required.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Glucemia/análisis , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 2/sangre , Interpretación Estadística de Datos , Femenino , Humanos , Masculino , Estándares de Referencia , Reproducibilidad de los Resultados
17.
Diabetes Technol Ther ; 15(10): 889-96, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23883407

RESUMEN

For self-monitoring of blood glucose by people with diabetes, the reliability of the measured blood glucose values is a prerequisite in order to ensure correct therapeutic decisions. Requirements for system accuracy are defined by the International Organization for Standardization (ISO) in the standard EN ISO 15197:2003. However, even a system with high analytical quality is not a guarantee for accurate and reliable measurement results. Under routine life conditions, blood glucose measurement results are affected by several factors. First, the act of performing measurements as well as the handling of the system may entail numerous possible error sources, such as traces of glucose-containing products on the fingertips, the use of deteriorated test strips, or the incorrect storage of test strips. Second, ambient and sampling conditions such as high altitude, partial pressure of oxygen, ambient temperature, and the use of alternate test sites can have an influence on measurement results. Therefore, the user-friendliness of a system and the quality of the manufacturer's labeling to reduce the risk of handling errors are also important aspects in ensuring reliable and accurate measurement results. In addition, the analytical performance of systems should be less prone to user errors and ambient conditions. Finally, people with diabetes must be aware of the information and instructions in the manufacturer's labeling and must be able to measure and interpret blood glucose results correctly.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 2/sangre , Cooperación del Paciente/estadística & datos numéricos , Manejo de Especímenes/métodos , Automonitorización de la Glucosa Sanguínea/métodos , Femenino , Alfabetización en Salud , Humanos , Masculino , Educación del Paciente como Asunto , Guías de Práctica Clínica como Asunto , Reproducibilidad de los Resultados
18.
J Diabetes Sci Technol ; 7(6): 1513-21, 2013 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-24351177

RESUMEN

BACKGROUND: Partial pressure of oxygen (pO2) in blood samples can affect blood glucose (BG) measurements, particularly in systems that employ the glucose oxidase (GOx) enzyme reaction on test strips. In this study, we assessed the impact of different pO2 values on the performance of five GOx systems and one glucose dehydrogenase (GDH) system. Two of the GOx systems are labeled by the manufacturers to be sensitive to increased blood oxygen content, while the other three GOx systems are not. METHODS: Aliquots of 20 venous samples were adjusted to the following pO2 values: <45, ~70, and ≥150 mmHg. For each system, five consecutive measurements on each sample aliquot were performed using the same test strip lot. Relative differences between the mean BG results at pO2 ~70 mmHg, which is considered to be similar to pO2 in capillary blood samples, and the mean BG result at pO2 <45 and ≥150 mmHg were calculated. RESULTS: For all tested GOx systems, mean relative differences in the BG measurement results were between 6.1% and 22.6% at pO2 <45 mmHg and between -7.9% and -14.9% at pO2 ≥150 mmHg. For both pO2 levels, relative differences of all tested GOx systems were significant (p < .0001). The GDH system showed mean relative differences of -1.0% and -0.4% at pO2 values <45 and ≥150 mmHg, respectively, which were not significant. CONCLUSIONS: These data suggest that capillary blood pO2 variations lead to clinically relevant BG measurement deviations in GOx systems, even in GOx systems that are not labeled as being oxygen sensitive.


Asunto(s)
Automonitorización de la Glucosa Sanguínea/métodos , Glucemia/análisis , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 2/sangre , Glucosa Oxidasa/sangre , Oxígeno/sangre , Adulto , Anciano , Altitud , Automonitorización de la Glucosa Sanguínea/instrumentación , Diabetes Mellitus Tipo 1/fisiopatología , Diabetes Mellitus Tipo 2/fisiopatología , Femenino , Glucosa 1-Deshidrogenasa/sangre , Humanos , Enfermedades Pulmonares/complicaciones , Enfermedades Pulmonares/fisiopatología , Masculino , Persona de Mediana Edad , Presión Parcial , Reproducibilidad de los Resultados
19.
J Diabetes Sci Technol ; 7(4): 833-41, 2013 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-23911164

RESUMEN

BACKGROUND: This study aimed at evaluating and comparing the performance of a new generation of continuous glucose monitoring (CGM) system versus other CGM systems, under daily lifelike conditions. METHODS: A total of 10 subjects (7 female) were enrolled in this study. Each subject wore two Dexcom G4™ CGM systems in parallel for the sensor lifetime specified by the manufacturer (7 days) to allow assessment of sensor-to-sensor precision. Capillary blood glucose (BG) measurements were performed at least once per hour during daytime and once at night. Glucose excursions were induced on two occasions. Performance was assessed by calculating the mean absolute relative difference (MARD) between CGM readings and paired capillary BG readings and precision absolute relative difference (PARD), i.e., differences between paired CGM readings. RESULTS: Overall aggregate MARD was 11.0% (n = 2392). Aggregate MARD for BG <70 mg/dl was 13.7%; for BG between 70 and 180 mg/dl, MARD was 11.4%; and for BG >180 mg/dl, MARD was 8.5%. Aggregate PARD was 7.3%, improving from 11.6% on day 1 to 5.2% on day 7. CONCLUSIONS: The Dexcom G4 CGM system showed good overall MARD compared with results reported for other commercially available CGM systems. In the hypoglycemic range, where CGM performance is often reported to be low, the Dexcom G4 CGM system achieved better MARD than that reported for other CGM systems in the hypoglycemic range. In the hyperglycemic range, the MARD was comparable to that reported for other CGM systems, whereas during induced glucose excursions, the MARD was similar or slightly worse than that reported for other CGM systems. Overall PARD was 7.3%, improving markedly with sensor life time.


Asunto(s)
Actividades Cotidianas , Glucemia/análisis , Diabetes Mellitus Tipo 1/sangre , Abdomen , Adulto , Automonitorización de la Glucosa Sanguínea/instrumentación , Automonitorización de la Glucosa Sanguínea/métodos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Femenino , Humanos , Implantes Experimentales , Infusiones Subcutáneas , Insulina/administración & dosificación , Sistemas de Infusión de Insulina , Masculino , Persona de Mediana Edad , Grasa Subcutánea
20.
J Diabetes Sci Technol ; 7(4): 815-23, 2013 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-23911162

RESUMEN

BACKGROUND: The performance of a continuous glucose monitoring (CGM) system in the early stage of development was assessed in an inpatient setting that simulates daily life conditions of people with diabetes. Performance was evaluated at low glycemic, euglycemic, and high glycemic ranges as well as during phases with rapid glucose excursions. METHODS: Each of the 30 participants with type 1 diabetes (15 female, age 47 ± 12 years, hemoglobin A1c 7.7% ± 1.3%) wore two sensors of the prototype system in parallel for 7 days. Capillary blood samples were measured at least 16 times per day (at least 15 times per daytime and at least once per night). On two subsequent study days, glucose excursions were induced. For performance evaluation, the mean absolute relative difference (MARD) between CGM readings and paired capillary blood glucose readings and precision absolute relative difference (PARD), i.e., differences between paired CGM readings were calculated. RESULTS: Overall aggregated MARD was 9.2% and overall aggregated PARD was 7.5%. During induced glucose excursions, MARD was 10.9% and PARD was 7.8%. Lowest MARD (8.5%) and lowest PARD (6.4%) were observed in the high glycemic range (euglycemic range, MARD 9.1% and PARD 7.4%; low glycemic range, MARD 12.3% and PARD 12.4%). CONCLUSIONS: The performance of this prototype CGM system was, particularly in the hypoglycemic range and during phases with rapid glucose fluctuations, better than performance data reported for other commercially available systems. In addition, performance of this prototype sensor was noticeably constant over the whole study period. This prototype system is not yet approved, and performance of this CGM system needs to be further assessed in clinical studies.


Asunto(s)
Técnicas Biosensibles/instrumentación , Glucemia/análisis , Diabetes Mellitus Tipo 1/sangre , Abdomen , Adulto , Automonitorización de la Glucosa Sanguínea/instrumentación , Femenino , Humanos , Implantes Experimentales , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad , Grasa Subcutánea , Adulto Joven
SELECCIÓN DE REFERENCIAS