Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Publication year range
1.
Odontology ; 112(4): 1231-1247, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38689144

RESUMEN

The aim of this study was to evaluate the effect of the All-on-4 design and 4 alternative implant-supported fixed prosthesis designs on stress distribution in implants, peri-implant bone, and prosthetic framework in the edentulous mandible under different loading conditions using three-dimensional finite element analysis (3D-FEA).Five different experimental finite element models (Model A (unsplinted 6), Model B (splinted 6), Model C (All-on-4), Model D (axial; 2 anterior, 2 posterior), and Model E (4 interforaminal)) were created. Three different loading conditions were applied (canine loading, unilateral I-loading, and unilateral II-loading). The highest minimum (Pmin) and the maximum (Pmax) principal stress values were acquired for cortical and trabecular bones; the highest von Mises (mvM) stress values were obtained for implants and metal frameworks. Model B and Model D showed the most favorable stress distribution. The All-on-4 design (Model C) also showed acceptable stress values close to those of Model B and Model D in the cortical and trabecular bones. In accordance with the stress values in the bone structure, the lowest stress values were measured in the implants and Co-Cr framework in Model B and Model D. The highest stress values in all structures were measured for unilateral loading- II, while the lowest values were found for canine loading. It was concluded that Model B and Model D experimental models showed better biomechanical performance in all structures. Furthermore, the use of a splinted framework, avoiding cantilevers, results in lower stress transmission. On the other hand, canine loading and unilateral loading-I exhibited the best loading conditions.


Asunto(s)
Prótesis Dental de Soporte Implantado , Análisis del Estrés Dental , Análisis de Elementos Finitos , Arcada Edéntula , Mandíbula , Humanos , Fenómenos Biomecánicos , Imagenología Tridimensional , Diseño de Prótesis Dental , Implantes Dentales , Diseño de Dentadura , Estrés Mecánico
2.
Int J Prosthodont ; (3): 339-348, 2024 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-38227831

RESUMEN

PURPOSE: To evaluate the stress distribution along a premolar's root dentin, its post, and its post-luting agent when materials with different elastic moduli are used to fabricate one-piece post-and-cores in two different designs. MATERIALS AND METHODS: Two 3D virtual models (for cylindrical and conical post designs) of a mandibular premolar restored with one-piece post-and-core restorations were obtained using a software. A total of eight post-and-core materials were tested: polyetheretherketone (PEEK), polyetherketoneketone (PEKK), glass fiber-reinforced polyetheretherketone (GFR-PEEK), carbon fiber-reinforced polyetheretherketone (CFR-PEEK), gold-palladium alloy (Au-Pd), titanium (Ti), zirconia (Zi), and chromium-nickel (Cr-Ni). Maximum principals stress (MPS) in the post, post-luting agent, and root dentin were determined. A load of 150 N was applied to the buccal cusp in the linguo-labial direction at an angle of 45 degrees oblique to the longitudinal axis of the crown. RESULTS: The highest MPS value in post structure was observed with Cr-Ni material for both post designs. Similarly, the highest MPS value in the post-luting agent was observed for Cr-Ni, the material with the highest elastic modulus. However, in the root dentin, the highest value was observed in PEEK, the material with the lowest elastic modulus. CONCLUSIONS: Post material and design influenced the stress concentration in the post, post-luting agent, and root dentin. The stress at the root dentin was slightly higher for polymeric materials. Cylindrical post design revealed lower stresses than conical post design at root dentin for all post-and-core materials tested.


Asunto(s)
Benzofenonas , Fibra de Carbono , Materiales Dentales , Dentina , Módulo de Elasticidad , Cetonas , Ensayo de Materiales , Polietilenglicoles , Polímeros , Técnica de Perno Muñón , Titanio , Circonio , Polímeros/química , Humanos , Polietilenglicoles/química , Cetonas/química , Materiales Dentales/química , Circonio/química , Fenómenos Biomecánicos , Titanio/química , Diente Premolar , Vidrio/química , Aleaciones de Cromo/química , Aleaciones de Oro/química , Diseño de Prótesis Dental , Carbono , Análisis del Estrés Dental , Paladio/química , Raíz del Diente , Aleaciones Dentales/química , Estrés Mecánico , Níquel/química
3.
Braz Oral Res ; 36: e042, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35293507

RESUMEN

Although the effects of different intraoral scanners, model scanners, and CAM units on the marginal and internal fitting of restorations have been investigated, the effects of CAD software in particular has not been evaluated. The marginal and internal fit of indirect restorations may vary according to the CAD software used, even when using the same intraoral scanner and milling machine. The purpose of this study was to evaluate the marginal and internal fit of milled full ceramic crowns designed with three different CAD systems. Eleven typodont maxillary first premolar teeth were prepared and scanned using a 3Shape TRIOS Intraoral Dental Scanner. The obtained STL scan data were exported and used to design a full crown using three different CAD systems (CEREC, KaVo, and Planmeca). An independent milling unit was used to manufacture the crowns for each group (n = 11). The marginal and internal fit were evaluated for each restoration using 2D and 3D micro-CT analysis. For 2D analysis, 18 measurements for each sample were made, covering the marginal (Marginal Gap Buccal (MG-A), Marginal Gap Palatinal (MG-B), Finish Line Buccal (FL-A), Finish Line Palatinal (FA-B)) and internal fit locations (Axial Wall Buccal (AW-A), Axial Wall Palatinal (AW-B), Lingual Cusp (LC), Buccal Cusp (BC), and Occlusal Central Fossa (OCF)). Statistical analyses were performed using Open Source R Statistical Software (α = 0.05) The results of Duncan's multiple range test showed that the values for the marginal measurement points MG-A, MG-B, FL-A, and FL-B in the Planmeca group were significantly higher than the values obtained in the CEREC and KaVo groups (p < 0.05). In AW1, values of the CEREC group were found to be higher than those of the KaVo and Planmeca groups (p < 0.05). CAD software showed an effect on the marginal fit values of crowns whereas no significant difference was observed in terms of the internal fit, except for a single measurement point made from the buccal direction.


Asunto(s)
Adaptación Marginal Dental , Diseño de Prótesis Dental , Cerámica , Diseño Asistido por Computadora , Coronas , Porcelana Dental , Programas Informáticos
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda