Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Med J Malaysia ; 65(2): 119-22, 2010 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23756795

RESUMEN

Full field digital mammography (FFDM) has been progressively introduced in medical centers in recent years. However, it is questionable which exposure parameters are suitable in order to reduce the glandular breast doses as they are related to induced carcinogenesis. The goal of this study was to compare the average glandular doses (AGD) and image quality of three FFDM systems namely Siemens Mammomat NovationDR, Hologic Lorad Selenia and General Electric Senographe Essential using a Figure of Merit. A Computerized Imaging Reference Systems (CIRS) tissue equivalent breast phantom which consists of phototimer compensation plate with different thickness and glandularity was exposed in fully automatic exposure control mode in the cranio-caudal projection similar to clinical settings. Thermoluminescent dosimeter 100H (TLD- 100H) was used to measure the entrance surface air kerma (ESAK), the AGD was calculated using European protocol whilst the image quality was assessed quantitatively by measuring the contrast to noise ratio (CNR) value. The obtained values were used to calculate the Figure of Merit (FOM) to analyze the effectiveness of the system. Repeated Measures ANOVA analysis showed that there is a significant difference (p<0.05) in the mean value of AGD and CNR between the three FFDM systems. Hologic Lorad Selenia system contrbuted the highest AGD value while General Electric Senographe Essential had the highest CNR and FOM value. In conclusion, this study may provide an objective criterion during the selection of a mammography unit by using the figure of merit for screening or diagnostic purpose.


Asunto(s)
Dosis de Radiación , Intensificación de Imagen Radiográfica , Mama , Humanos , Mamografía , Fantasmas de Imagen
3.
Phys Med Biol ; 51(22): 5843-57, 2006 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-17068368

RESUMEN

We describe a semi-automated technique for the quantitative assessment of breast density from digitized mammograms in comparison with patterns suggested by Tabar. It was developed using the MATLAB-based graphical user interface applications. It is based on an interactive thresholding method, after a short automated method that shows the fibroglandular tissue area, breast area and breast density each time new thresholds are placed on the image. The breast density is taken as a percentage of the fibroglandular tissue to the breast tissue areas. It was tested in four different ways, namely by examining: (i) correlation of the quantitative assessment results with subjective classification, (ii) classification performance using the quantitative assessment technique, (iii) interobserver agreement and (iv) intraobserver agreement. The results of the quantitative assessment correlated well (r2 = 0.92) with the subjective Tabar patterns classified by the radiologist (correctly classified 83% of digitized mammograms). The average kappa coefficient for the agreement between the readers was 0.63. This indicated moderate agreement between the three observers in classifying breast density using the quantitative assessment technique. The kappa coefficient of 0.75 for intraobserver agreement reflected good agreement between two sets of readings. The technique may be useful as a supplement to the radiologist's assessment in classifying mammograms into Tabar's pattern associated with breast cancer risk.


Asunto(s)
Absorciometría de Fotón/métodos , Neoplasias de la Mama/diagnóstico , Mamografía/métodos , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Medición de Riesgo/métodos , Algoritmos , Inteligencia Artificial , Femenino , Humanos , Reconocimiento de Normas Patrones Automatizadas/métodos , Pronóstico , Reproducibilidad de los Resultados , Factores de Riesgo , Sensibilidad y Especificidad , Programas Informáticos
4.
BMC Res Notes ; 6: 19, 2013 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-23331739

RESUMEN

BACKGROUND: Cutaneous Crohn's Disease is a notoriously difficult condition to treat and causes significant morbidity, impacting heavily on quality of life. This is the first study in adults examining the effect of topical tacrolimus on the different cutaneous manifestations of Crohn's Disease. METHODS: This open label observational study of 20 patients with heterogeneous forms of cutaneous Crohn's disease used topical tacrolimus 0.1% ointment once daily to affected areas for 12 weeks with a maximal total dose of 90g. Therapy was stopped at 12 weeks to assess whether the condition relapsed. Thereafter relapsing patients optionally continued an open label extension of topical tacrolimus therapy and were observed for a total of 12 months. RESULTS: Of seventeen patients completing the twelve-week study, fifteen improved using a specifically designed physicians' global severity scale. One patient cleared, four showed a pronounced improvement (51-75%) and ten demonstrated a mild (1-25%) or moderate improvement (25-50%) in twelve weeks. Over twelve months eleven patients remained in the study, nine of which improved, one cleared and one showed no change. Perineal disease responded better with two out of twelve clearing, four showing pronounced benefit and four mild to moderate improvement. Long-term application of 0.1% tacrolimus applied to broken skin and mucosa was safe and serum levels of tacrolimus were undetectable in all subjects throughout the study. CONCLUSION: 0.1% tacrolimus ointment was safe and effective in treating cutaneous manifestations of Crohn's disease, particularly perineal disease and pyoderma gangrenosum, yet it seldom cleared the condition. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Protocol Registration System ID: 33000332.


Asunto(s)
Enfermedad de Crohn/tratamiento farmacológico , Inmunosupresores/uso terapéutico , Pomadas , Enfermedades de la Piel/tratamiento farmacológico , Tacrolimus/uso terapéutico , Administración Tópica , Adolescente , Adulto , Anciano , Niño , Femenino , Humanos , Inmunosupresores/administración & dosificación , Masculino , Persona de Mediana Edad , Tacrolimus/administración & dosificación , Adulto Joven
5.
Psychopharmacology (Berl) ; 221(4): 667-74, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22193726

RESUMEN

RATIONALE: The acne drug isotretinoin has 13-cis retinoic acid as its active agent. Adverse effects that have been described include severe depression. Animal studies indicate that the hippocampus is particularly sensitive to retinoic acid. Changes induced by isotretinoin to hippocampal function could contribute to depression but may be more evident in altered visuospatial learning and memory, the primary function of the hippocampus. OBJECTIVES: We aimed to test the hypothesis that a course of oral isotretinoin therapy would result in declining visuospatial learning and memory. METHODS: CANTAB tasks designed to assess visuospatial memory were performed repeatedly on 14 males and 3 females in an open prospective observational study of patients with severe acne undergoing isotretinoin therapy. Beck's Depression Inventory and Global Acne Grade were also administered. RESULTS: Performance stayed unchanged for DMS, SRM and PRM tasks, while surprisingly participants improved their speed on the PRM task. Performance improved across sessions on the PAL task, and moreover the dose of isotretinoin correlated with improvement in the total trial score, reduction in total error rate and stage completed at the first trial. CONCLUSION: Isotretinoin does not reduce learning and memory and our study suggests that it may instead lead to a dose-related improvement in specific aspects of hippocampal learning and memory. Retinoic acid functions in the hippocampus as the active metabolite of vitamin A, suggesting that this may be a limiting factor in the human hippocampus and addition of exogenous retinoic acid brings levels closer to an optimal state.


Asunto(s)
Fármacos Dermatológicos/farmacología , Isotretinoína/farmacología , Aprendizaje/efectos de los fármacos , Memoria/efectos de los fármacos , Acné Vulgar/tratamiento farmacológico , Acné Vulgar/patología , Administración Oral , Adolescente , Adulto , Fármacos Dermatológicos/administración & dosificación , Fármacos Dermatológicos/efectos adversos , Relación Dosis-Respuesta a Droga , Femenino , Hipocampo/efectos de los fármacos , Hipocampo/metabolismo , Humanos , Isotretinoína/administración & dosificación , Isotretinoína/efectos adversos , Masculino , Pruebas Neuropsicológicas , Estudios Prospectivos , Índice de Severidad de la Enfermedad , Adulto Joven
7.
Artículo en Inglés | WPRIM | ID: wpr-625897

RESUMEN

Digital mammography has been progressively introduced in screening centers and the concern is to achieve an image of diagnostic value which would be able to detect early changes in the breast tissue. The aim of this study was to evaluate the image quality of mammograms using quantitative and qualitative methods of two FFDM systems with variations in breast thickness and anode/filter combination. This study was done from January to April 2008 with two FFDM systems; Siemens Mammomat NovationDR at Diagnostic Imaging Department, Hospital Kuala Lumpur and Hologic Lorad Selenia at Breast Clinic, National Cancer Society. A CIRS012A tissue equivalent breast phantom (4, 5 and 6 cm) thickness was used to obtain images in the craniocaudal plane with 26-32 kVp and a combination of molybdenum/molybdenum (Mo/Mo) and molybdenum/rhodium (Mo/Rh) anode/filter. For the qualitative evaluation, two independent radiologist with a minimum of five years experience was used to score the images. Wilcoxon Sign Rank Test showed that there are no significant differences (p > 0.05) in image quality between both the FFDM systems. Kappa analysis had a poor agreement between the scores given by the two radiologists. The quantitative analysis using Mann-Whitney test showed that there are significant differences (p < 0.05) between the SNR values of both FFDM systems. Although the qualitative evaluation was similar, the study showed that Lorad Selenia had a significantly superior SNR value, hence would be a better tool to detect early changes in the breast tissue. This study also demonstrated that a lower kVp is more suitable with molybdenum filter and as the breast thickness is increased rhodium filter with higher kVp displayed better quality images.

SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda