Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
Publication year range
1.
Cytometry B Clin Cytom ; 74(5): 319-29, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18431793

RESUMEN

BACKGROUND: Flow cytometric analysis of human P2X(7) pore activity segregates variant from common P2RX7 genotypes and may serve as a biomarker for cancer, pain, inflammation, and immune responses to infection. Standardization is needed to accommodate variable sample age and instrumentation differences in a multicenter clinical trial. METHODS: CD14-PE-stained whole blood samples were treated with YO-PRO-1 combined with a P2X(7) agonist (BzATP) or control, followed by the addition of PI after closure of the P2X(7) pore. Recalled instrument settings from previous publications were used to adapt a standardized fluorescent particle-adjusted set-up method. Experiments were performed to compare the two methods while evaluating components of systematic variability and facilitating reliable processing of samples with varied ages. RESULTS: The median YO-PRO-1 fluorescence of BzATP-treated samples had less variability when collected by the bead-adjusted method and was less influenced by the compensation strategy used. The average day-to-day coefficient of variance for assessments of P2X(7) pore activity by this method was 0.11 +/- 0.04, and the exclusion of nonviable cells was found to accommodate samples aged up to 4 days after phlebotomy. The bead-adjusted set-up method produced measurements differing by only 2.0% +/- 1.5% on two analog cytometers, and within similar decades when comparing analog to digital instruments. CONCLUSIONS: These results provide a standardized method for quantitative flow cytometric analysis of P2X(7) receptor phenotypes in blood monocytes with minimal intralaboratory variation and potential for interlaboratory comparisons that can greatly facilitate multicenter functional genomic clinical studies.


Asunto(s)
Ensayos Clínicos como Asunto , Citometría de Flujo/métodos , Estudios Multicéntricos como Asunto , Receptores Purinérgicos P2/metabolismo , Adenosina Trifosfato/análogos & derivados , Envejecimiento/efectos de los fármacos , Asma/diagnóstico , Benzoxazoles , Supervivencia Celular/efectos de los fármacos , Citometría de Flujo/instrumentación , Fluorescencia , Humanos , Receptores de Lipopolisacáridos/metabolismo , Monocitos/citología , Monocitos/efectos de los fármacos , Flebotomía , Compuestos de Quinolinio , Receptores Purinérgicos P2X7
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda