Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Idioma
Tipo del documento
Publication year range
1.
Zhongguo Zhong Yao Za Zhi ; 45(21): 5232-5237, 2020 Nov.
Artículo en Zh | MEDLINE | ID: mdl-33350240

RESUMEN

In this study, 10 batches of samples of cultured Bovis Calculus(cow-bezoar) were determined for the investigation of chemical profile of bile acids with the UPLC-QDA method established. The results showed that nine common bile acids, cholic acid(CA), deoxycholic acid(DCA), chenodeoxycholic acid(CDCA), taurocholic acid(TCA), taurodeoxycholic acid(TDCA), taurochenodeoxycholic acid(TCDCA), glycocholic acid(GCA), glycodeoxycholic acid(GDCA) and glycochenodeoxycholic acid(GCDCA), were founded in samples and 7 bile acids were quantified except GDCA and GCDCA. In these samples, unconjugated bile acids, the major type of bile acids, accounted for more than 97% of all types of bile acids. As for unconjugated bile acids, CA was the most major bile acid in cultured cow-bezoar and it was about twice as much as DCA. The relative low-cost method established in the current study is accurate, rapid and sensitive, which is suitable for the studies of other drugs from animal bile.


Asunto(s)
Ácidos y Sales Biliares , Cálculos , Animales , Bilis , Bovinos , Femenino
2.
Zhongguo Zhong Yao Za Zhi ; 45(22): 5511-5517, 2020 Nov.
Artículo en Zh | MEDLINE | ID: mdl-33350213

RESUMEN

Evaporative light scattering detector(ELSD) and charged aerosol detector(CAD) methods were established in this study for the content determination of four kinds of sugars in Zhusheyong Yiqi Fumai(YQFM), and the factors affecting the accuracy of CAD methods were discussed. HPLC-ELSD chromatographic separation was performed on a Shodex Asahipak NH2 P-50 column with acetonitrile-water(75∶25)as the mobile phase, with a flow rate of 0.8 mL·min~(-1), drift tube temperature of 80 ℃. The analysis by HPLC-CAD was performed on the same column with acetonitrile-water as mobile phase for gradient elution, with a flow rate of 0.8 mL·min~(-1), a neb temperature of 45 ℃, and power function(PF) of 1.3. The samples of YQFM were detected by ELSD and CAD respectively. It was found that YQFM was composed of fructose, glucose, sucrose and maltose. The linear relationship of the two methods was good, and the recoveries, reproducibility and stability of these four kinds of sugars measured by the two methods satisfied the requirements of methodology. Both CAD and ELSD detectors were accurate and reliable in detecting saccharides components in YQFM. In addition, it was revealed in this study for the first time that the PF parameter of CAD had an important influence on the accuracy of sugar determination and acted as the key parameter of CAD method. It was also found that for CAD, a non-linear detector, there was no significant difference between the results of linear regression and logarithmic regression.


Asunto(s)
Carbohidratos , Azúcares , Aerosoles , Cromatografía Líquida de Alta Presión , Luz , Reproducibilidad de los Resultados , Dispersión de Radiación
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda