Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Anesth Analg ; 123(2): 346-56, 2016 08.
Artículo en Inglés | MEDLINE | ID: mdl-27284998

RESUMEN

BACKGROUND: Scoliosis surgery is often associated with substantial blood loss, requiring fluid resuscitation and blood transfusions. In adults, dynamic preload indices have been shown to be more reliable for guiding fluid resuscitation, but these indices have not been useful in children undergoing surgery. The aim of this study was to introduce frequency-analyzed photoplethysmogram (PPG) and arterial pressure waveform variables and to study the ability of these parameters to detect early bleeding in children during surgery. METHODS: We studied 20 children undergoing spinal fusion. Electrocardiogram, arterial pressure, finger pulse oximetry (finger PPG), and airway pressure waveforms were analyzed using time domain and frequency domain methods of analysis. Frequency domain analysis consisted of calculating the amplitude density of PPG and arterial pressure waveforms at the respiratory and cardiac frequencies using Fourier analysis. This generated 2 measurements: The first is related to slow mean arterial pressure modulation induced by ventilation (also known as DC modulation when referring to the PPG), and the second corresponds to pulse pressure modulation (AC modulation or changes in the amplitude of pulse oximeter plethysmograph when referring to the PPG). Both PPG and arterial pressure measurements were divided by their respective cardiac pulse amplitude to generate DC% and AC% (normalized values). Standard hemodynamic data were also recorded. Data at baseline and after bleeding (estimated blood loss about 9% of blood volume) were presented as median and interquartile range and compared using Wilcoxon signed-rank tests; a Bonferroni-corrected P value <0.05 was considered statistically significant. RESULTS: There were significant increases in PPG DC% (median [interquartile range] = 359% [210 to 541], P = 0.002), PPG AC% (160% [87 to 251], P = 0.003), and arterial DC% (44% [19 to 84], P = 0.012) modulations, respectively, whereas arterial AC% modulations showed nonsignificant increase (41% [1 to 85], P = 0.12). The change in PPG DC% was significantly higher than that in PPG AC%, arterial DC%, arterial AC%, and systolic blood pressure with P values of 0.008, 0.002, 0.003, and 0.002, respectively. Only systolic blood pressure showed significant changes (11% [4 to 21], P = 0.003) between bleeding phase and baseline. CONCLUSIONS: Finger PPG and arterial waveform parameters (using frequency analysis) can track changes in blood volume during the bleeding phase, suggesting the potential for a noninvasive monitor for tracking changes in blood volume in pediatric patients. PPG waveform baseline modulation (PPG DC%) was more sensitive to changes in venous blood volume when compared with respiration-induced modulation seen in the arterial pressure waveform.


Asunto(s)
Volumen Sanguíneo , Monitoreo Intraoperatorio/métodos , Oximetría , Oxígeno/sangre , Fotopletismografía , Respiración Artificial , Escoliosis/cirugía , Fusión Vertebral , Adolescente , Factores de Edad , Presión Arterial , Biomarcadores/sangre , Pérdida de Sangre Quirúrgica/prevención & control , Femenino , Análisis de Fourier , Humanos , Hipovolemia/etiología , Hipovolemia/fisiopatología , Hipovolemia/prevención & control , Masculino , Valor Predictivo de las Pruebas , Escoliosis/diagnóstico , Fusión Vertebral/efectos adversos , Factores de Tiempo
2.
J Clin Monit Comput ; 28(6): 591-6, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24420341

RESUMEN

During shoulder surgery, patients typically are placed in the beach chair position. In rare cases, this positioning has resulted in devastating outcomes of postoperative cerebral ischemia (Cullen and Kirby in APSF Newsl 22(2):25-27, 2007; Munis in APSF Newsl 22(4):82-83, 2008). This study presents a method to noninvasively and continuously hemodynamically monitor patients during beach chair positioning by using the photoplethysmograph signal recorded from a commercial pulse oximeter. Twenty-nine adults undergoing shoulder surgery were monitored before and after beach chair positioning with electrocardiogram, intermittent blood pressure, end tidal carbon dioxide, and photoplethysmograph via Nellcor finger pulse oximeter. Fast Fourier transform (FFT) was used to perform frequency-domain analysis on the photoplethysmograph (PPG) signal for data segments taken 80-120 s before and after beach chair positioning. The amplitude density of respiration-associated PPG oscillations was quantified measuring the height of the FFT peak at respiratory frequency. Results were reported as (median, interquartile range) and statistical analysis was performed using Wilcoxon sign rank test. Data were also collected when vasoactive drugs phenylephrine and ephedrine were used to maintain acceptable mean arterial pressure during a case. With beach chair positioning, all subjects who did not receive vasoactive drugs showed an increase in the FFT amplitude density of respiration-associated PPG oscillations (p < 0.0001) without change in pulse-associated PPG oscillations. The PPG was more accurate at monitoring the change to beach chair position than blood pressure or heart rate. With vasoactive drugs, pulse-associated PPG oscillations decreased only with phenylephrine while respiration-associated oscillations did not change. Frequency domain analysis of the PPG signal may be a better tool than traditional noninvasive hemodynamic parameters at monitoring patients during beach chair position surgery.


Asunto(s)
Anestésicos Generales/administración & dosificación , Presión Sanguínea/fisiología , Frecuencia Cardíaca/fisiología , Posicionamiento del Paciente/métodos , Fotopletismografía/efectos de los fármacos , Fotopletismografía/métodos , Postura/fisiología , Anestesia General/métodos , Presión Sanguínea/efectos de los fármacos , Monitoreo de Drogas/métodos , Femenino , Frecuencia Cardíaca/efectos de los fármacos , Humanos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
3.
Anesth Analg ; 115(1): 74-81, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22543068

RESUMEN

BACKGROUND: We designed this study to determine if 900 mL of blood withdrawal during spontaneous breathing in healthy volunteers could be detected by examining the time-varying spectral amplitude of the photoplethysmographic (PPG) waveform in the heart rate frequency band and/or in the breathing rate frequency band before significant changes occurred in heart rate or arterial blood pressure. We also identified the best PPG probe site for early detection of blood volume loss by testing ear, finger, and forehead sites. METHODS: Eight subjects had 900 mL of blood withdrawn followed by reinfusion of 900 mL of blood. Physiological monitoring included PPG waveforms from ear, finger, and forehead probe sites, standard electrocardiogram, and standard blood pressure cuff measurements. The time-varying amplitude sequences in the heart rate frequency band and breathing rate frequency band present in the PPG waveform were extracted from high-resolution time-frequency spectra. These amplitudes were used as a parameter for blood loss detection. RESULTS: Heart rate and arterial blood pressure did not significantly change during the protocol. Using time-frequency analysis of the PPG waveform from ear, finger, and forehead probe sites, the amplitude signal extracted at the frequency corresponding to the heart rate significantly decreased when 900 mL of blood was withdrawn, relative to baseline (all P < 0.05); for the ear, the corresponding signal decreased when only 300 mL of blood was withdrawn. The mean percent decrease in the amplitude of the heart rate component at 900 mL blood loss relative to baseline was 45.2% (38.2%), 42.0% (29.2%), and 42.3% (30.5%) for ear, finger, and forehead probe sites, respectively, with the lower 95% confidence limit shown in parentheses. After 900 mL blood reinfusion, the amplitude signal at the heart rate frequency showed a recovery towards baseline. There was a clear separation of amplitude values at the heart rate frequency between baseline and 900 mL blood withdrawal. Specificity and sensitivity were both found to be 87.5% with 95% confidence intervals (47.4%, 99.7%) for ear PPG signals for a chosen threshold value that was optimized to separate the 2 clusters of amplitude values (baseline and blood loss) at the heart rate frequency. Meanwhile, no significant changes in the spectral amplitude in the frequency band corresponding to respiration were found. CONCLUSION: A time-frequency spectral method detected blood loss in spontaneously breathing subjects before the onset of significant changes in heart rate or blood pressure. Spectral amplitudes at the heart rate frequency band were found to significantly decrease during blood loss in spontaneously breathing subjects, whereas those at the breathing rate frequency band did not significantly change. This technique may serve as a valuable tool in intraoperative and trauma settings to detect and monitor hemorrhage.


Asunto(s)
Determinación del Volumen Sanguíneo/métodos , Volumen Sanguíneo , Frecuencia Cardíaca , Hipovolemia/diagnóstico , Rayos Infrarrojos , Fotopletismografía , Mecánica Respiratoria , Procesamiento de Señales Asistido por Computador , Adulto , Presión Sanguínea , Determinación de la Presión Sanguínea , Transfusión de Sangre Autóloga , Análisis por Conglomerados , Connecticut , Electrocardiografía , Humanos , Hipovolemia/fisiopatología , Masculino , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad , Factores de Tiempo
4.
J Clin Monit Comput ; 25(6): 377-85, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22051898

RESUMEN

INTRODUCTION: Our study sought to explore changes in photoplethysmographic (PPG) waveform param- eters, during lower body negative pressure (LBNP) which simulated hypovolemia, in spontaneously breathing volunteers. We hypothesize that during progressive LBNP; there will be a preservation of ear PPG parameters and a decrease in finger PPG parameters. METHODS: With IRB approval, 11 volunteers underwent a LBNP protocol at baseline, 30, 75, and 90 mm Hg (or until the subject became symptomatic). Subjects were monitored with finger and ear pulse oximeter probes, an ECG, and a finger arterial blood pressure monitor. The square root of the mean of the squared differences between adjacent NN intervals (RMSSD) which is the time domain analysis of the heart rate variability (HRV) was measured. PPG waveforms were analyzed for height, area, width 50, maximum and minimum slope. Data are presented as median and inter-quartile range. Friedman ANOVA and Wilcoxon tests were used to identify changes in hemo- dynamic and PPG parameters, P < 0.017 was considered statistically significant. RESULTS: There were no significant changes in the blood pressure variables at LBNP(30), but at and beyond LBNP(75), the decreases in systolic, mean and pulse pressure were significant as was the increase in diastolic pressure. Heart rate increased significantly at LBNP(30), reaching a maximum of 75.4% above baseline at the symptomatic phase while RMSSD showed significant reduction at LBNP(75). Finger PPG height, area, width 50, and maximum slope decreased significantly at LBNP(30) and during symptomatic phase they showed a reduction of 59.4, 76.9, 27.4 and 51.6%, respectively. Ear PPG height, area, width 50 and maximum slope did not change significantly until the LBNP(75), reached. During symptomatic phase, the respective declines reached 39.3, 61.0, 21.4 and 34.9%. CONCLUSION: PPG waveform parameters may prove to be sensitive and specific as early indicators of blood loss. These PPG changes were observed before profound decreases in arterial blood pressure. The relative sparing of central cutaneous blood flow is consistent with the increased parasympathetic innervation of central structures.


Asunto(s)
Algoritmos , Determinación del Volumen Sanguíneo/métodos , Diagnóstico por Computador/métodos , Hipovolemia/diagnóstico , Hipovolemia/fisiopatología , Presión Negativa de la Región Corporal Inferior , Fotopletismografía/métodos , Adulto , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
5.
J Clin Monit Comput ; 25(6): 387-96, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22057245

RESUMEN

OBJECTIVE: The photoplethysmographic (PPG) waveforms are modulated by the respiratory, cardiac and autonomic nervous system. Lower body negative pressure (LBNP) has been used as an experimental tool to simulate loss of central blood volume in humans. The aim of our research is to understanding PPG waveform changes during progressive hypovolemia. METHODS: With IRB approval, 11 volunteers underwent a LBNP protocol at baseline, 30, 75, and 90 mmHg (or until the subject became symptomatic). Subjects were monitored with finger and ear pulse oximeter probes, ECG, and finger arterial blood pressure monitor (FABP). Heart rate variability (HRV) was analyzed to high frequency (HRV-HF) (0.12-0.4 Hz) and low frequency (HRV-LF) (0.04-0.12 Hz). Frequency analysis of PPG waveforms were computed to low (0.04-0.11 Hz) frequency (PPG-LF), intermediate (0.12-0.18 Hz) frequency (PPG-IF), respiratory (0.19-0.3 Hz) frequency (PPG-Resp.) and cardiac (0.75-2.5 Hz) frequency (PPG-Cardiac)during different phases of LBNP protocol RESULTS: Heart rate increased significantly while systolic, mean and pulse pressure of the FABP declined slowly together with significant reductions in HRV-HF (0.12-0.4 Hz) and HRV-LF (0.04-0.12 Hz) power at LBNP(75). There was significant reduction in finger PPG-Cardiac modulation which is consistent with the reduction in the pulse pressure of the FABP. As the LBNP progress there was shift in the amplitude density of the ear PPG-Cardiac to PPG-Resp. Oscillation as an evidence of progressive hypovolemia with reduction in pulse pressure and increase in the respiratory induced variations. At LBNP(75), there were significant increased (>140% increase from the baseline) in ear PPG-IF (0.12-0.18 Hz) in the meantime HRV-HF showed significant reduction (>89%) from the baseline. At the symptomatic phase; there was a shift in ear PPG-IF to PPG-Resp. With an increase in the ear PPG-Resp. Modulation to ≥175% from the baseline CONCLUSION: The pulse oximeter waveform contains a complex mixture of the effect of cardiac, venous, autonomic, and respiratory systems on the central and peripheral circulation. The occurrence of autonomic modulation needs to be taken into account when studying signals that have their origins from central sites (e.g. ear and forehead).


Asunto(s)
Algoritmos , Determinación del Volumen Sanguíneo/métodos , Diagnóstico por Computador/métodos , Hipovolemia/diagnóstico , Hipovolemia/fisiopatología , Presión Negativa de la Región Corporal Inferior , Fotopletismografía/métodos , Adulto , Femenino , Humanos , Masculino , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
6.
J Clin Monit Comput ; 24(4): 295-303, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20644985

RESUMEN

OBJECTIVE: We investigate the hypothesis that the photoplethysmograph (PPG) waveform can be analyzed to infer regional venous oxygen saturation. METHODS: Fundamental to the successful isolation of the venous saturation is the identification of PPG characteristics that are unique to the peripheral venous system. Two such characteristics have been identified. First, the peripheral venous waveform tends to reflect atrial contraction. Second, ventilation tends to move venous blood preferentially due to the low pressure and high compliance of the venous system. Red (660 nm) and IR (940 nm) PPG waveforms were collected from 10 cardiac surgery patients using an esophageal PPG probe. These waveforms were analyzed using algorithms written in Mathematica. Four time-domain saturation algorithms (ArtSat, VenSat, ArtInstSat, VenInstSat) and four frequency-domain saturation algorithms (RespDC, RespAC, Cardiac, and Harmonic) were applied to the data set. RESULTS: Three of the algorithms for calculating venous saturation (VenSat, VenInstSat, and RespDC) demonstrate significant difference from ArtSat (the conventional time-domain algorithm for measuring arterial saturation) using the Wilcoxon signed-rank test with Bonferroni correction (p < 0.0071). CONCLUSIONS: This work introduces new algorithms for PPG analysis. Three algorithms (VenSat, VenInstSat, and RespDC) succeed in detecting lower saturation blood. The next step is to confirm the accuracy of the measurement by comparing them to a gold standard (i.e., venous blood gas).


Asunto(s)
Esófago/metabolismo , Oxígeno/sangre , Fotopletismografía/instrumentación , Fotopletismografía/métodos , Algoritmos , Interpretación Estadística de Datos , Humanos , Flujo Pulsátil , Venas
7.
Clin Pediatr (Phila) ; 58(4): 417-427, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30596266

RESUMEN

Since 2000, the number of emergency department visits and hospital admissions for children who have sustained a fall from a skateboard has undergone a noticeable decline. One possible explanation for this decline is that children today lead a more sedentary lifestyle and are not as engaged in outdoor physical activities as were children in previous generations. The profile of patients injured in skateboarding-related accidents has also changed since 2000. The percent minority, percent residents of large metropolitan areas, and percent who incur an injury on a street or highway have all increased during this time period. Data based on observations of riders in skateboard parks indicate that the overwhelming majority do not wear protective gear such as helmets, elbow/knee pads, or wrist guards, and that a sizable segment of riders compound their risk of injury by using headphones or earbuds when performing maneuvers.


Asunto(s)
Traumatismos en Atletas/epidemiología , Patinación/lesiones , Adolescente , Niño , Preescolar , Bases de Datos Factuales , Servicio de Urgencia en Hospital , Femenino , Humanos , Incidencia , Masculino , Equipos de Seguridad , Estados Unidos/epidemiología , Adulto Joven
8.
J Clin Anesth ; 20(2): 90-3, 2008 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-18410861

RESUMEN

STUDY OBJECTIVE: To test whether the relative insensitivity of craniofacial vessels to catecholamines differs in response to arginine vasopressin. DESIGN: Prospective, observational human study. SETTING: University hospital. PATIENTS: 8 ASA physical status I and II women scheduled for elective myomectomy. INTERVENTIONS: Patients underwent elective myomectomy surgery with intrauterine injection of arginine vasopressin. MEASUREMENTS: Finger, ear, and forehead photoplethysmographs were monitored. Changes in the plethysmographic amplitudes were recorded before and after arginine vasopressin injection. MAIN RESULTS: In all subjects, ear photoplethysmographic amplitude (but not oxygen saturation) decreased precipitously (62% +/- 10%; P < 0.001) after arginine vasopressin injection. In contrast, there was no significant decline in the finger signal (4.5% +/- 27%; P = 0.19). The forehead plethysmograph decreased in amplitude, but this finding did not achieve significance (33% +/- 18%; P = 0.18). CONCLUSION: In contrast to prior observations during adrenergic activation, arginine vasopressin induced relatively greater vasoconstriction at the ear and forehead than at the finger. This finding has potential implications with respect to arginine vasopressin's effect on blood flow and indicates that monitoring the ear plethysmographic signal may provide useful information during arginine vasopressin administration.


Asunto(s)
Oído/irrigación sanguínea , Dedos/irrigación sanguínea , Leiomioma/cirugía , Fotopletismografía/efectos de los fármacos , Vasoconstrictores/farmacología , Vasopresinas/farmacología , Catecolaminas/fisiología , Femenino , Frente/irrigación sanguínea , Humanos , Leiomioma/irrigación sanguínea , Fotopletismografía/métodos , Estudios Prospectivos , Vasoconstricción/fisiología
9.
J Clin Anesth ; 20(2): 122-8, 2008 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-18410867

RESUMEN

STUDY OBJECTIVE: To determine if recommendations regarding perioperative beta-blocker therapy were followed by an increase in the number of eligible presurgical patients receiving beta-blockers and the number achieving the recommended heart rate (HR <60 beats per minute [bpm]). DESIGN: Retrospective, observational study. SETTING: Tertiary-care teaching hospital. MEASUREMENTS: The records of all 718 patients who underwent elective vascular surgery or coronary artery bypass grafting between January 2001 and March 2002 (pre-guideline) and those who did so between April 2002 and September 2003 (post-guideline) were reviewed. Percentage of eligible patients who received beta-blockers preoperatively and the target HR achieved in pre-guideline versus post-guideline patients were recorded. Differences were assessed using the unpaired t test and chi2 analysis. A P value of less than 0.05 is reported. MAIN RESULTS: Fifty percent of the post-guideline patients in the vascular surgery group were receiving beta-blockers at the time of preanesthetic evaluation versus 48% of pre-guideline patients (P = nonsignificant [NS]). Mean HR in the vascular surgery post-guideline beta-blocker group (70 +/- 14 bpm) was higher than in the pre-guideline beta-blocker group (65 +/- 11 bpm) (P < 0.01). Only 22% of those vascular surgery patients in the post-guideline group who were taking beta-blockers achieved the target HR of less than 60 bpm versus 29% of the vascular surgery patients taking beta-blockers in the pre-guideline group (P = NS). In the coronary artery bypass grafting group, 80% of post-guideline patients received beta-blocker before anesthesia assessment versus 75% of pre-guideline patients (P = NS). Mean HR in the post-guideline beta-blocker group (67 +/- 15 bpm) was similar to the pre-guideline beta-blocker group (64 +/- 13 bpm) (P = NS). Only 28% of the post-guideline patients who were receiving beta-blockers achieved the target HR of less than 60 bpm, which was not significantly different from the 17% achieved in the pre-guideline group (P = NS). CONCLUSION: At our institution, preoperative beta-blocker use was not significantly changed by publication of the recommendations.


Asunto(s)
Antagonistas Adrenérgicos beta/uso terapéutico , Frecuencia Cardíaca/efectos de los fármacos , Pautas de la Práctica en Medicina , Cuidados Preoperatorios/métodos , Anciano , Femenino , Adhesión a Directriz , Humanos , Masculino , Guías de Práctica Clínica como Asunto , Estudios Retrospectivos , Resultado del Tratamiento , Procedimientos Quirúrgicos Vasculares
10.
Clin Pediatr (Phila) ; 57(5): 563-573, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-28969430

RESUMEN

The objective of this study is to document the incidence of falls from playground equipment in the United States over time and to provide a detailed profile of the individuals injured in playground falls using several state and national databases. During the past decade, there has been a steep decline in the number of injuries treated in emergency departments caused by falls from playground equipment in the United States. Males, children between the ages of 5 to 9 years, and individuals from lower economic strata are overrepresented among those suffering an injury. Falls from monkey bars result in the greatest number of injuries (52%). Schools/day care centers and recreation areas each account for approximately 40% of injuries. The incidence of injuries occurring at home playgrounds has declined sharply in recent years. Fracture of the upper limb is the type of injury most often associated with a fall from playground equipment (43%).


Asunto(s)
Accidentes por Caídas/estadística & datos numéricos , Juego e Implementos de Juego/lesiones , Heridas y Lesiones/epidemiología , Distribución por Edad , Niño , Preescolar , Femenino , Humanos , Incidencia , Masculino , Factores de Riesgo , Seguridad , Distribución por Sexo , Estados Unidos
11.
Anesth Analg ; 104(3): 615-8, 2007 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-17312219

RESUMEN

BACKGROUND: One purpose of preanesthesia evaluation clinics (PECs) is to decrease the incidence of day-of-surgery delays and cancellations by ensuring that patients are medically ready for surgery. In several single-center studies, PECs have been shown to have a positive impact. However, limited information is available regarding their overall use and perceived effectiveness. METHODS: A survey was distributed to attendees of the 2005 Annual Meeting of the American Society of Anesthesiologists. The survey addressed the national prevalence of PECs and the most common methods for referral to them. Respondents were also asked to address the impact of PEC visits on perceived prevalence of day-of-surgery delays caused by missing patient information. RESULTS: One thousand eight hundred fifty-seven surveys were returned. Sixty- nine percent of respondents worked at institutions with a PEC. Fifty-seven percent of respondents indicated that delays occur in at least 1 in 10 patients not seen for preanesthesia evaluation prior to the day of surgery. For patients who had a PEC visit prior to surgery, the same frequency of delays was reported by 23% of respondents. CONCLUSIONS: Day-of-surgery delays caused by missing information remain relatively common despite preanesthesia evaluation. Possible causes for these delays include failures of information transfer, lack of consensus on criteria for surgical readiness, or other institutional factors.


Asunto(s)
Anestesiología/instrumentación , Anestesiología/métodos , Sistemas de Información en Quirófanos , Quirófanos , Anestesiología/educación , Citas y Horarios , Humanos , Gestión de la Información , Servicios de Información , Cuidados Preoperatorios/métodos , Encuestas y Cuestionarios , Factores de Tiempo
12.
Conn Med ; 71(8): 453-6, 2007 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-17902381

RESUMEN

BACKGROUND: An abnormal ECG often must be assessed preoperatively in the absence of prior tracings. We surveyed anesthesiologists to determine if their concern about nonspecific ST-T (NSST) wave changes is influenced significantly by the availability of a prior ECG for comparison. METHODS: Forty-eight anesthesiologists rated their concern (O=none, 1=minor, 2=moderate, 3=marked) about a patient with an intermediate cardiac risk factor and new NSST, NSST of indeterminate duration (no old ECG for comparison), or old NSST. RESULTS: Concern for patients with more recent development of NSST was significantly greater for each of the interage comparisons; P=0.019 for new vs indeterminate, P=0.003 for new vs old, and P=0.008 for indeterminate vs old. This was associated with increased tendency to obtain cardiology consultation. CONCLUSIONS: The efficiency of preoperative assessment of patients with NSST on ECG would be improved by consistent availability of prior ECG tracings to enable determination of the newness of current findings.


Asunto(s)
Anestesiología , Electrocardiografía , Cardiopatías/prevención & control , Complicaciones Intraoperatorias/prevención & control , Médicos/psicología , Cuidados Preoperatorios , Citas y Horarios , Cardiología , Humanos , Derivación y Consulta , Medición de Riesgo , Factores de Riesgo , Encuestas y Cuestionarios
13.
Anesth Analg ; 103(2): 372-7, table of contents, 2006 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16861419

RESUMEN

The cardiac pulse is the predominant feature of the pulse oximeter (plethysmographic) waveform. Less obvious is the effect of ventilation on the waveform. There have been efforts to measure the effect of ventilation on the waveform to determine respiratory rate, tidal volume, and blood volume. We measured the relative strength of the effect of ventilation on the reflective plethysmographic waveform at three different sites: the finger, ear, and forehead. The plethysmographic waveforms from 18 patients undergoing positive pressure ventilation during surgery and 10 patients spontaneously breathing during renal dialysis were collected. The respiratory signal was isolated from the waveform using spectral analysis. It was found that the respiratory signal in the pulse oximeter waveform was more than 10 times stronger in the region of the head when compared with the finger. This was true with both controlled positive pressure ventilation and spontaneous breathing. A significant correlation was demonstrated between the estimated blood loss from surgical procedures and the impact of ventilation on ear plethysmographic data (r(s) = 0.624, P = 0.006).


Asunto(s)
Pletismografía , Respiración con Presión Positiva , Respiración , Adulto , Anciano , Femenino , Humanos , Persona de Mediana Edad , Oximetría , Procesamiento de Señales Asistido por Computador
14.
Yale J Biol Med ; 79(1): 1-7, 2006 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-17876370

RESUMEN

OBJECTIVE: Assessments of endothelial cell function with acetylcholine have typically used systemic, regional intra-arterial, or iontophoretic delivery of drug. Each of these techniques induces systemic and/or local changes that compromise their safety or effectiveness. Using translucent drug preparations applied under laser Doppler flowmetry (LDF) probes, we tested whether local vasodilation can be induced with non-iontophoretic transdermal delivery of acetylcholine and how such dilation would compare to the dilation achieved with topical nitroglycerin in healthy volunteers. METHODS: Ten subjects without known vascular disease were recruited for LDF monitoring at sites of drug application for this preliminary investigation. Topical acetylcholine chloride, nitroglycerin, and placebo were applied via translucent patches to the forehead directly below LDF probes. RESULTS: LDF readings increased by 406 percent (245 percent to 566 percent) and 36 percent (26 percent to 46 percent), respectively, at the acetylcholine and placebo sites (p = .005 by Wilcoxon Signed Rank Test (WSRT) for acetylcholine vs. placebo); and they increased by 365 percent (179 percent to 550 percent) at the nitroglycerin site (p = .005 by WSRT for nitroglycerin vs. placebo; p = .6 vs. acetylcholine). CONCLUSION: Transdermal delivery of acetylcholine can induce significant local vasodilatory responses comparable to those achieved with nitroglycerin without requiring iontophoresis. The means of transdermal delivery and monitoring described herein may constitute a new minimally invasive way to interrogate the microvasculature and thereby assess the microcirculatory changes induced by various disorders and therapeutic interventions.


Asunto(s)
Acetilcolina/administración & dosificación , Flujometría por Láser-Doppler/métodos , Microcirculación/fisiología , Nitroglicerina/administración & dosificación , Administración Tópica , Adulto , Vendajes , Velocidad del Flujo Sanguíneo/efectos de los fármacos , Sistemas de Liberación de Medicamentos/métodos , Femenino , Humanos , Iontoforesis , Masculino , Microcirculación/efectos de los fármacos , Piel/irrigación sanguínea , Piel/efectos de los fármacos , Fenómenos Fisiológicos de la Piel/efectos de los fármacos , Enfermedades Vasculares/diagnóstico , Vasodilatación/efectos de los fármacos , Vasodilatación/fisiología
15.
J Clin Anesth ; 17(3): 191-7, 2005 May.
Artículo en Inglés | MEDLINE | ID: mdl-15896586

RESUMEN

STUDY OBJECTIVE: To quantify the prevalence of perioperative beta-blocker use and its impact on preoperative and preinduction heart rate (HR), in light of the recent publication of specific recommendations regarding perioperative beta-blocker use and desired HR. DESIGN: Retrospective observational study in patients who underwent elective and coronary artery bypass graft (CABG) surgery between January 2001 and March 2002. SETTING: Tertiary-care teaching hospital. MEASUREMENTS: Percentage of eligible patients who received beta-blockers preoperatively and the impact of non-protocol-based beta-blocker therapy on preadmission and preinduction HR were recorded. Differences were assessed with unpaired t test and chi(2) analysis; P < .05 was considered significant, with corrections for multiple comparisons. RESULTS: Of the patients who underwent vascular surgery, 9 had documented prior beta-blocker intolerance. Of the remaining 172 patients, 94.8% had indication for perioperative beta-blocker use. However, only 47.7% of the eligible patients received beta-blockers. Of the 155 CABG patients, 74.2% were taking beta-blockers preoperatively. Only 29% of vascular patients and 32% of CABG patients who were receiving beta-blockers had HR less than 60 beats per minute (bpm) at preadmission. The mean preadmission HR in vascular surgery patients was 65.2 +/- 11 and 73.2 +/- 13.8 bpm in beta-blocker and non-beta-blocker patients, respectively (P = .0001). In CABG surgery patients, preadmission HR values were 64.2 +/- 13 and 76.1 +/- 12 bpm in beta-blocker and non-beta-blocker patients, respectively (P = .001). The preinduction HR subsequently increased in the beta-blocker as well as in the non-beta-blocker groups. CONCLUSION: Only half of the patients who qualify to receive preoperative beta-blockers by current recommendations actually receive them before noncardiac surgery, and the majority of these patients have preadmission and preinduction HR less than 60 bpm. Targeting beta-blocker therapy treatment to an HR less than 60 bpm may not be readily achievable in many patients.


Asunto(s)
Antagonistas Adrenérgicos beta/farmacología , Puente de Arteria Coronaria , Frecuencia Cardíaca/efectos de los fármacos , Procedimientos Quirúrgicos Vasculares , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Cuidados Preoperatorios , Estudios Retrospectivos
16.
Yale J Biol Med ; 77(5-6): 149-54, 2004 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-15989744

RESUMEN

PURPOSE: The present study was undertaken to evaluate onset, and early and late recovery of neuromuscular block after a combination of mivacurium (M) and rocuronium (R). METHODS: In this controlled, randomized study, 45 consenting ASA I-II patients were assigned to one of three treatment groups: 2.ED95 R alone (2R); 2.ED95 R plus 1.ED95 M (2R1M). or 2.ED95 R plus 2.ED95 M (2R2M). Neuromuscular monitoring of the ulnar nerve consisted of surface electrode stimulation and force transduction of the adductor pollicis muscle. Stable baseline stimulation (1 Hz, square-wave, supramaximal current) was established prior to relaxant administration and continued until 95 percent twitch height depression (onset). Thereafter, train-of-four stimulation every 10 seconds was used to record recovery data until 95 percent recovery (T(95%)). Data were analyzed using grouped t-tests, ANOVA, and Newman-Keuls multiple comparison tests. Significance was defined at the p < 0.05 level. RESULTS: The addition of mivacurium to rocuronium did not accelerate onset of block. The combination prolonged the clinical duration (time to 5 percent recovery, T(5%)), but did not affect subsequent recovery parameters: T(5%) in the 2R1M and 2R2M groups were 100 percent and 118 percent longer than in the 2R group, respectively (p < 0.05) the T(5-25%) (early recovery) and T(25-75%) (linear recovery) indexes were similar in all three groups. CONCLUSIONS: The present study did not note an acceleration of block onset when mivacurium was added to rocuronium. The findings suggest that the addition of mivacurium (1-2.ED95) to rocuronium (2.ED95) prolongs the clinical duration of the longer-acting agent, rocuronium, but has no effect on the early or linear recovery indexes of rocuronium. Thus, although clinical duration is prolonged, recovery from the combination regimens proceeds as if no mivacurium had been added to rocuronium.


Asunto(s)
Androstanoles/farmacología , Isoquinolinas/farmacología , Bloqueo Neuromuscular , Unión Neuromuscular/efectos de los fármacos , Fármacos Neuromusculares no Despolarizantes/farmacología , Adolescente , Adulto , Anciano , Combinación de Medicamentos , Interacciones Farmacológicas , Humanos , Persona de Mediana Edad , Mivacurio , Rocuronio
17.
Physiol Meas ; 35(7): 1509-20, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24901895

RESUMEN

Lower body negative pressure (LBNP) creates a reversible hypovolemia by sequestrating blood volume in the lower extremities. This study sought to examine the impact of central hypovolemia on peripheral venous pressure (PVP) waveforms in spontaneously breathing subjects. With IRB approval, 11 healthy subjects underwent progressive LBNP (baseline, -30, -75, and -90 mmHg or until the subject became symptomatic). Each was monitored for heart rate (HR), finger arterial blood pressure (BP), a chest respiratory band and PVP waveforms which are generated from a transduced upper extremity intravenous site. The first subject was excluded from PVP analysis because of technical errors in collecting the venous pressure waveform. PVP waveforms were analyzed to determine venous pulse pressure, mean venous pressure, pulse width, maximum and minimum slope (time domain analysis) together with cardiac and respiratory modulations (frequency domain analysis). No changes of significance were found in the arterial BP values at -30 mmHg LBNP, while there were significant reductions in the PVP waveforms time domain parameters (except for 50% width of the respiration induced modulations) together with modulation of the PVP waveform at the cardiac frequency but not at the respiratory frequency. As the LBNP progressed, arterial systolic BP, mean BP and pulse pressure, PVP parameters and PVP cardiac modulation decreased significantly, while diastolic BP and HR increased significantly. Changes in hemodynamic and PVP waveform parameters reached a maximum during the symptomatic phase. During the recovery phase, there was a significant reduction in HR together with a significant increase in HR variability, mean PVP and PVP cardiac modulation. Thus, in response to mild hypovolemia induced by LBNP, changes in cardiac modulation and other PVP waveform parameters identified hypovolemia before detectable hemodynamic changes.


Asunto(s)
Hipovolemia/fisiopatología , Presión Negativa de la Región Corporal Inferior , Presión Venosa , Presión Sanguínea , Dedos/irrigación sanguínea , Voluntarios Sanos , Frecuencia Cardíaca , Humanos , Respiración , Factores de Tiempo
18.
J Am Med Inform Assoc ; 21(e2): e352-7, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24553477

RESUMEN

The objective was to assess use of a physician handoff tool embedded in the electronic medical record by nurses and other non-physicians. We administered a survey to nurses, physical therapists, discharge planners, social workers, and others to assess integration into daily practice, usefulness, and accuracy of the handoff tool. 231 individuals (61% response) participated. 60% used the tool often or usually/always during a shift. Nurses (46%) used the tool for shift transitions and found it helpful for medical history (79%) but not for acquiring medication, allergy, and responsible physician information. Nurses (96%) and others (75%) rated the tool as accurate. Medical nurses rated the tool more useful than surgical nurses, and pediatric nurses rarely used the tool. The tool was integrated into the daily workflow of non-physicians despite being designed for physician use. Non-physicians should be included in the design and implementation of electronic patient handoff systems.


Asunto(s)
Registros Electrónicos de Salud , Comunicación Interdisciplinaria , Pase de Guardia , Personal de Hospital , Hospitales de Enseñanza , Humanos , Errores Médicos/prevención & control , Flujo de Trabajo
19.
J Pain ; 14(8): 767-77.e8, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23743256

RESUMEN

UNLABELLED: In pain clinical trials, the rescue analgesic medication such as patient-controlled analgesia morphine is often made available for patients for breakthrough pain. The patient-controlled analgesia morphine usage decreases the study agent's effect on pain relative to placebo and introduces greater variability in attainment of pain scores. For assessment of analgesic efficacy, the isolated statistical analysis of pain score or morphine consumption as a surrogate marker for pain not only loses statistical efficiency but also may incur increased false-positive findings because of multiple testing. The aim of this article is to review the research to date for choices of statistical tests for pain or morphine consumption outcome, with a focus on systematically evaluating a means for collective analgesic assessment of pain and morphine consumption using an integrated outcome. A case example is illustrated for data visualization, statistical comparison, and effect size estimation using the new endpoint. Some implications for clinical practice and further research are discussed. PERSPECTIVE: This article provides statistical evidence to conclude that an integrated outcome of pain score and morphine consumption provides an efficient means for integrated analgesic assessment.


Asunto(s)
Analgésicos Opioides/uso terapéutico , Morfina/uso terapéutico , Dimensión del Dolor , Dolor/tratamiento farmacológico , Analgesia Controlada por el Paciente , Ensayos Clínicos como Asunto , Humanos , Dolor/diagnóstico
20.
Am J Phys Med Rehabil ; 92(10): 849-63, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24051992

RESUMEN

OBJECTIVE: The primary aims of this study were to design prediction models based on a functional marker (preoperative gait speed) to predict readiness for home discharge time of 90 mins or less and to identify those at risk for unplanned admissions after elective ambulatory surgery. DESIGN: This prospective observational cohort study evaluated all patients scheduled for elective ambulatory surgery. Home discharge readiness and unplanned admissions were the primary outcomes. Independent variables included preoperative gait speed, heart rate, and total anesthesia time. The relationship between all predictors and each primary outcome was determined in separate multivariable logistic regression models. RESULTS: After adjustment for covariates, gait speed with adjusted odds ratio of 3.71 (95% confidence interval, 1.21-11.26), P = 0.02, was independently associated with early home discharge readiness of 90 mins or less. Importantly, gait speed dichotomized as greater or less than 1 m/sec predicted unplanned admissions, with odds ratio of 0.35 (95% confidence interval, 0.16-0.76, P = 0.008) for those with speeds 1 m/sec or greater in comparison with those with speeds less than 1 m/sec. In a separate model, history of cardiac surgery with adjusted odds ratio of 7.5 (95% confidence interval, 2.34-24.41; P = 0.001) was independently associated with unplanned admissions after elective ambulatory surgery, when other covariates were held constant. CONCLUSIONS: This study demonstrates the use of novel prediction models based on gait speed testing to predict early home discharge and to identify those patients at risk for unplanned admissions after elective ambulatory surgery.


Asunto(s)
Procedimientos Quirúrgicos Ambulatorios , Marcha/fisiología , Admisión del Paciente/estadística & datos numéricos , Alta del Paciente , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Presión Sanguínea/fisiología , Procedimientos Quirúrgicos Cardiovasculares , Comorbilidad , Femenino , Cardiopatías/epidemiología , Frecuencia Cardíaca/fisiología , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Periodo Preoperatorio , Estudios Prospectivos , Adulto Joven
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda