Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Opt Lett ; 48(12): 3123-3126, 2023 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-37319042

RESUMEN

Devices based on the lossy mode resonance (LMR) effect have found numerous sensing applications. Herein, the enhancement of the sensing properties by the introduction of an intermediate layer between the substrate and the LMR-supporting film is discussed. Experimental results for a silicon oxide (SiO2) layer of tuned thickness between a glass slide substrate and a thin film of titanium oxide (TiO2) prove the possibility of significantly increasing the LMR depth and the figure of merit (FoM) for refractive index sensing applications, which is supported by a numerical analysis using the plane wave method for a one-dimensional multilayer waveguide. The application of the intermediate layer allows the introduction of a new, to the best of our knowledge, degree of freedom into the design of LMR-based sensors, resulting in improved performance for demanding fields such as chemical sensing or biosensing.


Asunto(s)
Técnicas Biosensibles , Refractometría , Dióxido de Silicio
2.
Opt Lett ; 46(6): 1454-1457, 2021 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-33720210

RESUMEN

The fundamental mode confinement loss (CL) of anti-resonant hollow-core fiber (ARF) is efficiently predicted by a classification task of machine learning. The structure-parameter vector is utilized to define the sample space of ARFs. The CL of labeled samples at 1550 nm is numerically calculated via the finite element method (FEM). The magnitude of CL is obtained by a classification task via a decision tree and k-nearest neighbors algorithms with the training and test sets generated by 290700 and 32300 labeled samples. The test accuracy, confusion matrices, and the receiver operating characteristic curves have shown that our proposed method is effective for predicting the magnitude of CL with a short computation runtime compared to FEM simulation. The feasibility of predicting other performance parameters by the extension of our method, as well as its ability to generalize outside the tested sample space, is also discussed. It is likely that the proposed sample definition and the use of a classification approach can be adopted for design application beyond efficient prediction of ARF CL and inspire artificial intelligence and data-driven-based research of photonic structures.

3.
Opt Express ; 28(11): 15934-15942, 2020 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-32549427

RESUMEN

In this work, we present a direct electrochemical biofunctionalization of an indium-tin-oxide-coated lossy-mode resonance optical fiber sensor. The functionalization using a biotin derivative was performed by cyclic voltammetry in a 10 mM biotin hydrazide solution. All stages of the experiment were simultaneously verified with optical and electrochemical techniques. Performed measurements indicate the presence of a poly-biotin layer on the sensor's surface. Furthermore, dual-domain detection of 0.01 and 0.1 mg/mL of avidin confirms the sensor's viability for label-free detection.

4.
Opt Express ; 28(22): 32483-32498, 2020 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-33114933

RESUMEN

In this work we discuss the effect of infiltration of different antiresonant fibers with low-refractive-index liquids, such as water and ethanol, on their optical properties. The fibers with single- and double-ring capillaries have been designed to show broad transmission bands in visible and near infrared range as it is required for optofluidics, in particular spectrophotometric applications. We show experimentally that their transmission windows shift toward shorter wavelengths and only modestly reduce their width. The transmission bands are located in the wavelength ranges of 533-670 nm and 707-925 nm, for the fibers when infiltrated with water. The two types of analyzed antiresonant fibers infiltrated with the liquids show similar light guidance properties when they are straight, but significantly lower bending loss can be achieved for the double-ring than for the single-ring antiresonant fiber. For this reason, the double-ring antiresonant fibers are more suitable as a compact solution for optofluidic applications, although transmission windows are reduced due to broader resonance peaks.

5.
Sensors (Basel) ; 20(13)2020 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-32635648

RESUMEN

Selected optical fiber sensors offer extraordinary sensitivity to changes in external refractive (RI), which make them promising for label-free biosensing. In this work the most sensitive ones, namely long-period gratings working at (DTP-LPG) and micro-cavity in-line Mach-Zehnder interferometers (µIMZI) are discussed for application in bacteria sensing. We describe their working principles and RI sensitivity when operating in water environments, which is as high as 20,000 nm/RIU (Refractive index unit) for DTP-LPGs and 27,000 nm/RIU for µIMZIs. Special attention is paid to the methods to enhance the sensitivity by etching and nano-coatings. While the DTP-LPGs offer a greater interaction length and sensitivity to changes taking place at their surface, the µIMZIs are best suited for investigations of sub-nanoliter and picoliter volumes. The capabilities of both the platforms for bacteria sensing are presented and compared for strains of Escherichia coli, lipopolysaccharide E. coli, outer membrane proteins of E. coli, and Staphylococcus aureus. While DTP-LPGs have been more explored for bacteria detection in 102-106 Colony Forming Unit (CFU)/mL for S. aureus and 103-109 CFU/mL for E. coli, the µIMZIs reached 102-108 CFU/mL for E. coli and have a potential for becoming picoliter bacteria sensors.


Asunto(s)
Técnicas Biosensibles , Escherichia coli/aislamiento & purificación , Fibras Ópticas , Staphylococcus aureus/aislamiento & purificación , Refractometría
6.
Sensors (Basel) ; 20(8)2020 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-32344713

RESUMEN

This work discusses sensing properties of a long-period grating (LPG) and microcavity in-line Mach-Zehnder interferometer (µIMZI) when both are induced in the same single-mode optical fiber. LPGs were either etched or nanocoated with aluminum oxide (Al2O3) to increase its refractive index (RI) sensitivity up to ≈2000 and 9000 nm/RIU, respectively. The µIMZI was machined using a femtosecond laser as a cylindrical cavity (d = 60 µm) in the center of the LPG. In transmission measurements for various RI in the cavity and around the LPG we observed two effects coming from the two independently working sensors. This dual operation had no significant impact on either of the devices in terms of their functional properties, especially in a lower RI range. Moreover, due to the properties of combined sensors two major effects can be distinguished-sensitivity to the RI of the volume and sensitivity to the RI at the surface. Considering also the negligible temperature sensitivity of the µIMZI, it makes the combination of LPG and µIMZI sensors a promising approach to limit cross-sensitivity or tackle simultaneous measurements of multiple effects with high efficiency and reliability.

7.
Sensors (Basel) ; 20(3)2020 Feb 03.
Artículo en Inglés | MEDLINE | ID: mdl-32028629

RESUMEN

Since the norovirus is the main cause of acute gastroenteritis all over the world, its fast detection is crucial in medical diagnostics. In this work, a rapid, sensitive, and selective optical fiber biosensor for the detection of norovirus virus-like particles (VLPs) is reported. The sensor is based on highly sensitive long-period fiber gratings (LPFGs) coated with antibodies against the main coat protein of the norovirus. Several modification methods were verified to obtain reliable immobilization of protein receptors on the LPFG surface. We were able to detect 1 ng/mL norovirus VLPs in a 40-min assay in a label-free manner. Thanks to the application of an optical fiber as the sensor, there is a possibility to increase the user's safety by separating the measurement point from the signal processing setup. Moreover, our sensor is small and light, and the proposed assay is straightforward. The designed LPFG-based biosensor could be applied in both fast norovirus detection and in vaccine testing.


Asunto(s)
Anticuerpos/aislamiento & purificación , Técnicas Biosensibles , Gastroenteritis/genética , Norovirus/aislamiento & purificación , Gastroenteritis/diagnóstico , Gastroenteritis/inmunología , Gastroenteritis/virología , Humanos , Norovirus/patogenicidad , Proteínas Virales/inmunología , Proteínas Virales/aislamiento & purificación
8.
Sensors (Basel) ; 18(5)2018 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-29702595

RESUMEN

In this work an application of optical fiber sensors for real-time optical monitoring of electrochemical deposition of ketoprofen during its anodic oxidation is discussed. The sensors were fabricated by reactive magnetron sputtering of indium tin oxide (ITO) on a 2.5 cm-long core of polymer-clad silica fibers. ITO tuned in optical properties and thickness allows for achieving a lossy-mode resonance (LMR) phenomenon and it can be simultaneously applied as an electrode in an electrochemical setup. The ITO-LMR electrode allows for optical monitoring of changes occurring at the electrode during electrochemical processing. The studies have shown that the ITO-LMR sensor’s spectral response strongly depends on electrochemical modification of its surface by ketoprofen. The effect can be applied for real-time detection of ketoprofen. The obtained sensitivities reached over 1400 nm/M (nm·mg−1·L) and 16,400 a.u./M (a.u.·mg−1·L) for resonance wavelength and transmission shifts, respectively. The proposed method is a valuable alternative for the analysis of ketoprofen within the concentration range of 0.25⁻250 μg mL−1, and allows for its determination at therapeutic and toxic levels. The proposed novel sensing approach provides a promising strategy for both optical and electrochemical detection of electrochemical modifications of ITO or its surface by various compounds.


Asunto(s)
Fibras Ópticas , Técnicas Biosensibles , Técnicas Electroquímicas , Cetoprofeno , Compuestos de Estaño
9.
Opt Express ; 25(21): 26118-26123, 2017 Oct 16.
Artículo en Inglés | MEDLINE | ID: mdl-29041272

RESUMEN

In this work we discuss the refractive index (RI) sensitivity of a micro-cavity in-line Mach-Zehnder interferometer in the form of a cylindrical hole (40-50 µm in diameter) fabricated in a standard single-mode optical fiber using a femtosecond laser. The surface of the micro-cavity was coated with up to 400 nm aluminum oxide thin film using the atomic layer deposition method. Next, the film was progressively chemically etched and the influence on changes in the RI of liquid in the micro-cavity was determined at different stages of the experiment, i.e., at different thicknesses of the film. An effect of transition between sensitivity to the film thickness (surface) and the RI of liquid in the cavity (bulk) is demonstrated for the first time. We have found that depending on the interferometer working conditions determined by thin film properties, the device can be used for investigation of phenomena taking place at the surface, such as in case of specific label-free biosensing applications, or for small-volume RI analysis as required in analytical chemistry.

10.
Opt Express ; 24(11): 11897-904, 2016 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-27410112

RESUMEN

In this work we report experimental results on optimizing the refractive index (RI) sensitivity of long-period gratings (LPGs) by fiber cladding etching and thin aluminum oxide (Al2O3) overlay deposition. The presented LPG takes advantage of work in the dispersion turning point (DTP) regime as well as the mode transition (MT) effect for higher-order cladding modes (LP09 and LP010). The MT was obtained by depositing Al2O3 overlays with single-nanometer precision using the Atomic Layer Deposition method (ALD). Etching of both the overlay and the fiber cladding was performed using hydrofluoric acid (HF). For shallow etching of the cladding, i.e., DTP observed at next = 1.429 and 1.439 RIU for an LPG with no overlay, followed by deposition of an overlay of up to 167 nm in thickness, HF etching allowed for post-deposition fine-tuning of the overlay thickness resulting in a significant increase in RI sensitivity mainly at the DTP of the LP09 cladding mode. However, at an external RI (next) above 1.39 RIU, the DTP of LP010 was noticed, and its RI sensitivity exceeded 9,000 nm/RIU. Deeper etching of the cladding, i.e., DTP observed for next above 1.45 RIU, followed by the deposition of thicker overlays (up to 201 nm in thickness) allowed the sensitivity to reach values of over 40,000 nm/RIU in a narrow RI range. Sensitivity exceeding 20,000 nm/RIU was obtained in an RI range suitable for label-free biosensing applications.

11.
Opt Express ; 23(7): 8441-53, 2015 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-25968683

RESUMEN

In this paper, we discuss an impact of thin titanium dioxide (TiO(2)) coatings on refractive index (RI) sensitivity and biofunctionalization of long-period gratings (LPGs). The TiO(2) overlays on the LPG surfaces have been obtained using atomic layer deposition (ALD) method. This method allows for a deposition of conformal, thickness-controlled, with well-defined optical properties, and high-RI thin films which are highly desired for optical fiber sensors. It has been found that for LPGs working at a dispersion turning point of higher order cladding modes only tens of nanometers of TiO(2) overlay thickness allow to obtain cladding mode transition effect, and thus significant improvement of RI sensitivity. When the TiO(2) overlay thickness reaches 70 nm, it is possible to obtain RI sensitivity exceeding 6200 nm/RIU in RI range where label-free sensors operate. Moreover, LPGs with TiO(2)-enhanced RI sensitivity have shown improved sensitivity to bacteria endotoxin (E. coli B lipopolysaccharide) detection, when TiO(2) surface is functionalized with endotoxin binding protein (adhesin) of T4 bacteriophage.

12.
Opt Express ; 22(5): 5986-94, 2014 Mar 10.
Artículo en Inglés | MEDLINE | ID: mdl-24663935

RESUMEN

The paper presents for the first time a study of long-period fiber gratings (LPFGs) applied for the measurements of reactive ion etching (RIE) process effect in various places of a plasma reactor. For the purposes of the experiment a number of highly sensitive LPFGs working at the dispersion turning point was fabricated using electric arc discharges. We show that the LPFGs allow for monitoring of the phenomena taking place in the reactor, especially those resulting in reduction of the LPFG diameter. Results of the measurements supported by simulations have shown that etching rate significantly decreases with elevation of the sample up to 3.6 mm over the electrode in the reactor, and stays constant above this height.

13.
Sci Rep ; 14(1): 23127, 2024 10 04.
Artículo en Inglés | MEDLINE | ID: mdl-39367065

RESUMEN

This work discusses label-free biosensing application of a double-layer optical fiber interferometer where the second layer tailors the reflection conditions at the external plain and supports changes in reflected optical spectrum when a bio-layer binds to it. The double-layer nanostructure consists of precisely tailored thin films, i.e., titanium (TiO2) and hafnium oxides (HfO2) deposited on single-mode fiber end-face by magnetron sputtering. It has been shown numerically and experimentally that the approach besides well spectrally defined interference pattern distinguishes refractive index (RI) changes taking place in a volume and on the sensor surface. These are of interest when label-free biosensing applications are considered. The case of myeloperoxidase (MPO) detection-a protein, which concentration rises during inflammation-is reported as an example of application. The response of the sensor to MPO in a concentration range of 1 × 10-11-5 × 10-6 g/mL was tested. An increase in the MPO concentration was followed by a redshift of the interference pattern and a decrease in reflected power. The negative control performed using ferritin proved specificity of the sensor. The results reported in this work indicate capability of the approach for diagnostic label-free biosensing, possibly also at in vivo conditions.


Asunto(s)
Técnicas Biosensibles , Interferometría , Fibras Ópticas , Peroxidasa , Técnicas Biosensibles/métodos , Técnicas Biosensibles/instrumentación , Interferometría/métodos , Peroxidasa/metabolismo , Titanio/química , Humanos , Inflamación/metabolismo , Inflamación/diagnóstico , Refractometría , Nanoestructuras/química
14.
Adv Sci (Weinh) ; 11(35): e2310118, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39044375

RESUMEN

Maintaining both high sensitivity and large figure of merit (FoM) is crucial in regard to the performance of optical devices, particularly when they are intended for use as biosensors with extremely low limit of detection (LoD). Here, a stack of nano-assembled layers in the form of 1D photonic crystal, deposited on D-shaped single-mode fibers, is created to meet these criteria, resulting in the generation of Bloch surface wave resonances. The increase in the contrast between high and low refractive index (RI) nano-layers, along with the reduction of losses, enables not only to achieve high sensitivity, but also a narrowed resonance bandwidth, leading to a significant enhancement in the FoM. Preliminary testing for bulk RI sensitivity is carried out, and the effect of an additional nano-layer that mimics a biological layer where binding interactions occur is also considered. Finally, the biosensing capability is assessed by detecting immunoglobulin G in serum at very low concentrations, and a record LoD of 70 aM is achieved. An optical fiber biosensor that is capable of attaining extraordinarily low LoD in the attomolar range is not only a remarkable technical outcome, but can also be envisaged as a powerful tool for early diagnosis of diseases.


Asunto(s)
Técnicas Biosensibles , Límite de Detección , Técnicas Biosensibles/métodos , Técnicas Biosensibles/instrumentación , Fibras Ópticas , Inmunoglobulina G/sangre , Refractometría/métodos , Nanotecnología/métodos , Nanotecnología/instrumentación , Diseño de Equipo , Humanos , Tecnología de Fibra Óptica/métodos
15.
Sci Rep ; 13(1): 15523, 2023 Sep 19.
Artículo en Inglés | MEDLINE | ID: mdl-37726408

RESUMEN

Spectroelectrochemical (SEC) measurements play a crucial role in analytical chemistry, utilizing transparent or semitransparent electrodes for optical analysis of electrochemical (EC) processes. The EC readout provides information about the electrode's state, while changes in the transmitted optical spectrum help identify the products of EC reactions. To enhance SEC measurements, this study proposes the addition of optical monitoring of the electrode. The setup involves using a polymer-clad silica multimode fiber core coated with indium tin oxide (ITO), which serves as both the electrode and an optical fiber sensor. The ITO film is specifically tailored to exhibit the lossy-mode resonance (LMR) phenomenon, allowing for simultaneous optical monitoring alongside EC readouts. The LMR response depends on the properties of the ITO and the surrounding medium's optical properties. As a result, the setup offers three types of interrogation readouts: EC measurements, optical spectrum analysis corresponding to the volume of the analyte (similar to standard SEC), and LMR spectrum analysis reflecting the state of the sensor/electrode surface. In each interrogation path, cyclic voltammetry (CV) experiments were conducted individually with two oxidation-reduction reaction (redox) probes: potassium ferricyanide and methylene blue. Subsequently, simultaneous measurements were performed during chronoamperometry (CA) with the sensor, and the cross-correlation between the readouts was examined. Overall, this study presents a novel and enhanced SEC measurement approach that incorporates optical monitoring of the electrode. It provides a comprehensive understanding of EC processes and enables greater insights into the characteristics of the analyte.

16.
Sci Rep ; 13(1): 1512, 2023 01 27.
Artículo en Inglés | MEDLINE | ID: mdl-36707671

RESUMEN

Accurate and fast detection of viruses is crucial for controlling outbreaks of many diseases; therefore, to date, numerous sensing systems for their detection have been studied. On top of the performance of these sensing systems, the availability of biorecognition elements specific to especially the new etiological agents is an additional fundamental challenge. Therefore, besides high sensitivity and selectivity, such advantages as the size of the sensor and possibly low volume of analyzed samples are also important, especially at the stage of evaluating the receptor-target interactions in the case of new etiological agents when typically, only tiny amounts of the receptor are available for testing. This work introduces a real-time, highly miniaturized sensing solution based on microcavity in-line Mach-Zehnder interferometer (µIMZI) induced in optical fiber for SARS-CoV-2 virus-like particles detection. The assay is designed to detect conserved regions of the SARS-CoV-2 viral particles in a sample with a volume as small as hundreds of picoliters, reaching the detection limit at the single ng per mL level.


Asunto(s)
Técnicas Biosensibles , COVID-19 , Humanos , Fibras Ópticas , SARS-CoV-2 , Interferometría , COVID-19/diagnóstico
17.
Biosensors (Basel) ; 14(1)2023 Dec 28.
Artículo en Inglés | MEDLINE | ID: mdl-38248392

RESUMEN

Fiber-optic biosensors have garnered significant attention and witnessed rapid development in recent years owing to their remarkable attributes such as high sensitivity, immunity to electromagnetic interference, and real-time monitoring. They have emerged as a potential tool in the realm of biomarker detection for low-concentration and small molecules. In this paper, a portable and cost-effective optical fiber biosensor based on surface plasmon resonance for the early detection of breast cancer is demonstrated. By utilizing the aptamer human epidermal growth factor receptor 2 (HER2) as a specific biomarker for breast cancer, the presence of the HER2 protein can be detected through an antigen-antibody binding technique. The detection method was accomplished by modifying a layer of HER2 aptamer on the flat surface of a gold-coated D-shaped polymer optical fiber (core/cladding diameter 120/490 µm), of which the residual thickness after side-polishing was about 245 µm, the thickness of the coated gold layer was 50 nm, and the initial wavelength in pure water was around 1200 nm. For low-concentration detection of the HER2 protein, the device exhibited a wavelength shift of ~1.37 nm with a concentration of 1 µg/mL (e.g., 5.5 nM), which corresponded to a limit of detection of ~5.28 nM. Notably, the response time of the biosensor was measured to be as fast as 5 s. The proposed biosensor exhibits the potential for early detection of HER2 protein in initial cancer serum and offers a pathway to early prevention of breast cancer.


Asunto(s)
Neoplasias , Resonancia por Plasmón de Superficie , Humanos , Fibras Ópticas , Tecnología de Fibra Óptica , Oro , Oligonucleótidos , Polímeros
18.
Materials (Basel) ; 15(12)2022 Jun 09.
Artículo en Inglés | MEDLINE | ID: mdl-35744176

RESUMEN

The effect of three popular surface activation methods for a titanium oxide (titania) surface was thoroughly investigated to identify the most effective protocol for the enhancement of hydrophilicity. All the methods, namely H2O2 activation, UV irradiation and oxygen plasma treatment resulted in an enhanced hydrophilic titania surface, which was evidenced by the reduced contact angle values. To study in detail the chemical and morphological features responsible for the increased hydrophilicity, the treated surfaces were submitted to inspection with atomic force microscopy and X-ray photoelectron spectroscopy. The correlation between the treatment and titania surface hydroxylation as well as hydrophilic behavior have been discussed.

19.
Biosens Bioelectron ; 217: 114718, 2022 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-36174357

RESUMEN

Monitoring cell adhesion and growth are crucial for various applications involving drug screening, cytotoxicity, and cytocompatibility studies. However, acquiring accurate information about the growing state and responsiveness to a treatment of a cell system in a real-time and label-free manner is still a challenge. This work presents the first research on direct, real-time, and label-free adherent cell culture monitoring using a microcavity in-line Mach-Zehnder interferometer (µIMZI) fabricated in an optical fiber. The sensing solution based on µIMZI offers a great advantage over many other monitoring concepts tracking the changes taking place on the microcavity's bottom surface and within its volume, thus offering a greater penetration depth. In this study, we verified performance of the approach using a non-cancer bone marrow stromal cell line HS-5. The results demonstrate that the changes of the acquired signal are closely related to the different states of cells' adhesion, proliferation, morphology, and variation of mass. Thus, this label-free, real-time µIMZI-based monitoring technique gives a great promise to the analysis or monitoring of relevant new treatments in future scientific, as well as clinical applications.


Asunto(s)
Técnicas Biosensibles , Fibras Ópticas , Técnicas de Cultivo de Célula , Interferometría/métodos
20.
Opt Express ; 19(9): 7971-8, 2011 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-21643046

RESUMEN

The paper presents for the first time a study of long-period gratings (LPGs) applied for label-free detection of specific bacteria using physically adsorbed bacteriophages. For the purposes of the experiment a number of highly sensitive LPGs working at the turning point of phase matching curve was fabricated in SMF28 fiber using UV exposure. We show that the device allows for real-time monitoring of phenomena taking place on the sensor's surface, including phage-bacteria interactions. For the applied conditions a resonance wavelength shift of ~1.3 nm induced by bacteria binding was observed.


Asunto(s)
Carga Bacteriana/instrumentación , Bacteriófago T4/fisiología , Bioensayo/instrumentación , Técnicas Biosensibles/instrumentación , Escherichia coli/aislamiento & purificación , Escherichia coli/fisiología , Refractometría/instrumentación , Adhesión Bacteriana/fisiología , Diseño de Equipo , Análisis de Falla de Equipo
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda