Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros

Banco de datos
País como asunto
Tipo del documento
Publication year range
1.
Small ; 20(2): e2304437, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37691013

RESUMEN

Bioinspired fibrillar structures are promising for a wide range of disruptive adhesive applications. Especially micro/nanofibrillar structures on gecko toes can have strong and controllable adhesion and shear on a wide range of surfaces with residual-free, repeatable, self-cleaning, and other unique features. Synthetic dry fibrillar adhesives inspired by such biological fibrils are optimized in different aspects to increase their performance. Previous fibril designs for shear optimization are limited by predefined standard shapes in a narrow range primarily based on human intuition, which restricts their maximum performance. This study combines the machine learning-based optimization and finite-element-method-based shear mechanics simulations to find shear-optimized fibril designs automatically. In addition, fabrication limitations are integrated into the simulations to have more experimentally relevant results. The computationally discovered shear-optimized structures are fabricated, experimentally validated, and compared with the simulations. The results show that the computed shear-optimized fibrils perform better than the predefined standard fibril designs. This design optimization method can be used in future real-world shear-based gripping or nonslip surface applications, such as robotic pick-and-place grippers, climbing robots, gloves, electronic devices, and medical and wearable devices.

2.
Small ; 17(39): e2102867, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34414656

RESUMEN

Setae, fibrils located on a gecko's feet, have been an inspiration of synthetic dry microfibrillar adhesives in the last two decades for a wide range of applications due to unique properties: residue-free, repeatable, tunable, controllable and silent adhesion; self-cleaning; and breathability. However, designing dry fibrillar adhesives is limited by a template-based-design-approach using a pre-determined bioinspired T- or wedge-shaped mushroom tip. Here, a machine learning-based computational approach to optimize designs of adhesive fibrils is shown, exploring a much broader design space. A combination of Bayesian optimization and finite element methods creates novel optimal designs of adhesive fibrils, which are fabricated by two-photon-polymerization-based 3D microprinting and double-molding-based replication out of polydimethylsiloxane. Such optimal elastomeric fibril designs outperform previously proposed designs by maximum 77% in the experiments of dry adhesion performance on smooth surfaces. Furthermore, finite-element-analyses reveal that the adhesion of the fibrils is sensitive to the 3D fibril stem shape, tensile deformation, and fibril microfabrication limits, which contrast with the previous assumptions that mostly neglect the deformation of the fibril tip and stem, and focus only on the fibril tip geometry. The proposed computational fibril design could help design future optimal fibrils with less help from human intuition.


Asunto(s)
Adhesivos , Lagartos , Animales , Teorema de Bayes , Elasticidad , Humanos , Aprendizaje Automático
3.
IEEE ASME Trans Mechatron ; 21(2): 708-716, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27458327

RESUMEN

This paper introduces a new five-dimensional localization method for an untethered meso-scale magnetic robot, which is manipulated by a computer-controlled electromagnetic system. The developed magnetic localization setup is a two-dimensional array of mono-axial Hall-effect sensors, which measure the perpendicular magnetic fields at their given positions. We introduce two steps for localizing a magnetic robot more accurately. First, the dipole modeled magnetic field of the electromagnet is subtracted from the measured data in order to determine the robot's magnetic field. Secondly, the subtracted magnetic field is twice differentiated in the perpendicular direction of the array, so that the effect of the electromagnetic field in the localization process is minimized. Five variables regarding the position and orientation of the robot are determined by minimizing the error between the measured magnetic field and the modeled magnetic field in an optimization method. The resulting position error is 2.1±0.8 mm and angular error is 6.7±4.3° within the applicable range (5 cm) of magnetic field sensors at 200 Hz. The proposed localization method would be used for the position feedback control of untethered magnetic devices or robots for medical applications in the future.

4.
Adv Mater ; 34(13): e2109325, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35060215

RESUMEN

Recently, the realization of minimally invasive medical interventions on targeted tissues using wireless small-scale medical robots has received an increasing attention. For effective implementation, such robots should have a strong adhesion capability to biological tissues and at the same time easy controlled detachment should be possible, which has been challenging. To address such issue, a small-scale soft robot with octopus-inspired hydrogel adhesive (OHA) is proposed. Hydrogels of different Young's moduli are adapted to achieve a biocompatible adhesive with strong wet adhesion by preventing the collapse of the octopus-inspired patterns during preloading. Introduction of poly(N-isopropylacrylamide) hydrogel for dome-like protuberance structure inside the sucker wall of polyethylene glycol diacrylate hydrogel provides a strong tissue attachment in underwater and at the same time enables easy detachment by temperature changes due to its temperature-dependent volume change property. It is finally demonstrated that the small-scale soft OHA robot can efficiently implement biomedical functions owing to strong adhesion and controllable detachment on biological tissues while operating inside the body. Such robots with repeatable tissue attachment and detachment possibility pave the way for future wireless soft miniature robots with minimally invasive medical interventions.


Asunto(s)
Hidrogeles , Robótica , Adhesivos , Materiales Biocompatibles/química , Humanos , Hidrogeles/química , Adherencias Tisulares
5.
Sci Adv ; 8(2): eabk0685, 2022 Jan 14.
Artículo en Inglés | MEDLINE | ID: mdl-35030013

RESUMEN

The application of the Shannon entropy to study the relationship between information and structures has yielded insights into molecular and material systems. However, the difficulty in directly observing and manipulating atoms and molecules hampers the ability of these systems to serve as model systems for further exploring the links between information and structures. Here, we use, as a model experimental system, hundreds of spinning magnetic micro-disks self-organizing at the air-water interface to generate various spatiotemporal patterns with varying degrees of order. Using the neighbor distance as the information-bearing variable, we demonstrate the links among information, structure, and interactions. We establish a direct link between information and structure without using explicit knowledge of interactions. Last, we show that the Shannon entropy by neighbor distances is a powerful observable in characterizing structural changes. Our findings are relevant for analyzing natural self-organizing systems and for designing collective robots.

6.
Sci Adv ; 7(43): eabi8932, 2021 Oct 22.
Artículo en Inglés | MEDLINE | ID: mdl-34669466

RESUMEN

Creating wireless milliscale robots that navigate inside soft tissues of the human body for medical applications has been a challenge because of the limited onboard propulsion and powering capacity at small scale. Here, we propose around 100 permanent magnet array­based remotely propelled millirobot system that enables a cylindrical magnetic millirobot to navigate in soft tissues via continuous penetration. By creating a strong magnetic force trap with magnetic gradients on the order of 7 T/m inside a soft tissue, the robot is attracted to the center of the array even without active control. By combining the array with a motion stage and a fluoroscopic x-ray imaging system, the magnetic robot followed complex paths in an ex vivo porcine brain with extreme curvatures in sub-millimeter precision. This system enables future wireless medical millirobots that can deliver drugs; perform biopsy, hyperthermia, and cauterization; and stimulate neurons with small incisions in body tissues.

7.
Adv Sci (Weinh) ; 8(17): e2100641, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34218533

RESUMEN

While suction cups prevail as common gripping tools for a wide range of real-world parts and surfaces, they often fail to seal the contact interface when engaging with irregular shapes and textured surfaces. In this work, the authors propose a suction-based soft robotic gripper where suction is created inside a self-sealing, highly conformable and thin flat elastic membrane contacting a given part surface. Such soft gripper can self-adapt the size of its effective suction area with respect to the applied load. The elastomeric membrane covering edge of the soft gripper can develop an air-tight self-sealing with parts even smaller than the gripper diameter. Such gripper shows 4 times higher adhesion than the one without the membrane on various textured surfaces. The two major advantages, underactuated self-adaptability and enhanced suction performance, allow the membrane-based suction mechanism to grip various three-dimensional (3D) geometries and delicate parts, such as egg, lime, apple, and even hydrogels without noticeable damage, which can have not been gripped with the previous adhesive microstructures-based and active suction-based soft grippers. The structural and material simplicity of the proposed soft gripper design can have a broad use in diverse fields, such as digital manufacturing, robotic manipulation, transfer printing, and medical gripping.


Asunto(s)
Diseño de Equipo/métodos , Fenómenos Mecánicos , Robótica/instrumentación , Robótica/métodos , Módulo de Elasticidad , Fuerza de la Mano , Succión
8.
Soft Robot ; 7(1): 10-21, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31418640

RESUMEN

Wireless capsule endoscopes have revolutionized diagnostic procedures in the gastrointestinal (GI) tract by minimizing discomfort and trauma. Biopsy procedures, which are often necessary for a confirmed diagnosis of an illness, have been incorporated recently into robotic capsule endoscopes to improve their diagnostic functionality beyond only imaging. However, capsule robots to date have only been able to acquire biopsy samples of superficial tissues of the GI tract, which could generate false-negative diagnostic results if the diseased tissue is under the surface of the GI tract. To improve their diagnostic accuracy for submucosal tumors/diseases, we propose a magnetically actuated soft robotic capsule robot, which takes biopsy samples in a deep tissue of a stomach using the fine-needle biopsy technique. We present the design, control, and human-machine interfacing methods for the fine-needle biopsy capsule robot. Ex vivo experiments in a porcine stomach show 85% yield for the biopsy of phantom tumors located underneath the first layers of the stomach wall.


Asunto(s)
Endoscopía Capsular/instrumentación , Enfermedades Gastrointestinales/diagnóstico , Animales , Biopsia con Aguja Fina , Diseño de Equipo , Humanos , Robótica , Sensibilidad y Especificidad , Porcinos , Interfaz Usuario-Computador , Tecnología Inalámbrica
9.
Adv Mater ; 32(19): e2000497, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32239584

RESUMEN

Bioinspired elastomeric fibrillar surfaces have significant potential as reversible dry adhesives, but their adhesion performance is sensitive to the presence of liquids at the contact interface. Like their models in nature, many artificial mimics can effectively repel water, but fail when low-surface-tension liquids are introduced at the contact interface. A bioinspired fibrillar adhesive surface that is liquid-superrepellent even toward ultralow-surface-tension liquids while retaining its adhesive properties is proposed herein. This surface combines the effective adhesion principle of mushroom-shaped fibrillar arrays with liquid repellency based on double re-entrant fibril tip geometry. The adhesion performance of the proposed microfibril structures is retained even when low-surface-tension liquids are added to the contact interface. The extreme liquid repellency enables real-world applications of fibrillar adhesives for surfaces covered with water, oil, and other liquids. Moreover, fully elastomeric liquid-superrepellent surfaces are mechanically not brittle, highly robust against physical contact, and highly deformable and stretchable, which can increase the real-world uses of such antiwetting surfaces.

10.
Int Immunopharmacol ; 4(13): 1603-13, 2004 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-15454113

RESUMEN

To elucidate the signaling pathways involved in the expression of CD83, which is linked to the differentiation and maturation states of dendritic cells, we examined the effect of phosphatidic acid (PA) on the expression of CD83 in KG1, a CD34(+) hematopoietic progenitor cell. In the presence of tumor necrosis factor (TNF)-alpha, PA but not lyso-PA up-regulated CD83 on KG1 cells. Moreover, PA and TNF-alpha-induced expression of CD83 was slightly increased by propranolol, an inhibitor of PA phosphohydrolase but was unaffected by phospholipase A2 inhibitor. PA and TNF-alpha increased the phosphorylation of extracellular signal-regulated kinase (ERK)-1/2, p38-kinase, and c-Jun N-terminal kinase (JNK) by Western blotting. However, the up-regulation of CD83 by PA/TNF-alpha on KG1 was significantly abrogated by PD98059, a specific inhibitor of ERK kinase, but was enhanced by SP600125, a JNK inhibitor. Bis-indolylmaleimide, an inhibitor of protein kinase C, partially blocked the up-regulation of CD83 and ERK phosphorylation induced by PA and TNF-alpha. Moreover, the incubation of KG1 cells with phorbol ester and TNF-alpha for 5 days increased the protein level of phospholipase D. These results suggest that PA and TNF-alpha induce the up-regulation of CD83 and that their action is regulated by ERK and JNK.


Asunto(s)
Antígenos CD34/efectos de los fármacos , Células Madre Hematopoyéticas/efectos de los fármacos , Inmunoglobulinas/genética , Glicoproteínas de Membrana/genética , Quinasas de Proteína Quinasa Activadas por Mitógenos/metabolismo , Ácidos Fosfatidicos/farmacología , Factor de Necrosis Tumoral alfa/farmacología , Regulación hacia Arriba/genética , Antígenos CD , Antígenos CD34/metabolismo , Antígeno CD11c/genética , Antígeno CD11c/metabolismo , Diferenciación Celular/efectos de los fármacos , Línea Celular Tumoral , Células Dendríticas/efectos de los fármacos , Células Dendríticas/metabolismo , Combinación de Medicamentos , Flavonoides/farmacología , Células Madre Hematopoyéticas/metabolismo , Humanos , Inmunoglobulinas/efectos de los fármacos , Proteínas Quinasas JNK Activadas por Mitógenos/metabolismo , Corea (Geográfico) , Glicoproteínas de Membrana/efectos de los fármacos , Fosfolipasa D/metabolismo , Fosfolipasa D/farmacología , Células Tumorales Cultivadas , Regulación hacia Arriba/efectos de los fármacos , Antígeno CD83
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda