Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Radiol Med ; 126(7): 956-962, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33843004

RESUMEN

PURPOSE: To demonstrate the utility of a biopsy performed just before vertebroplasty in patients with diagnosis of vertebral compression fracture (VCF) and no history of neoplastic or hematologic diseases. BACKGROUND: Osteoporosis is the most frequent cause of vertebral compression fracture, with trauma and pathologic vertebral weakening being other common causes. Since secondary fractures at imaging investigation can present as simple compression fractures, it is important to identify an underlying pathology. The aim of this paper is to evaluate the frequency of unexpected positive histology in vertebral samples withdrawn from patients undergoing a vertebroplasty to evaluate if a vertebral biopsy can routinely be used in case of VCF and when a secondary cause is not suspected. METHODS: We retrospectively evaluated the results of 324 biopsies performed from February 2003 to March 2019 just before vertebroplasty in 1183 patients diagnosed with one or more vertebral compression fractures and with no history of neoplastic or hematological diseases and with no suspicious findings for secondary fractures at imaging. RESULTS: Biopsy was not diagnostic in 9/324 cases (2.8%); osteoporosis was the diagnosis in 295 cases (91%); in the remaining 20 cases (6.2%), histology was positive for an underlying pathology: 12/20 (60% of positive cases) multiple myeloma; 5/20 (25%) lymphoma/leukemia; 1/20 (5%) spondylitis; 1/20 (5%) metastasis; 1/20 (5%) hemangioma. A significantly higher incidence of positive biopsies was found in patients younger than 73 (p = 0.01) with 17 of 20 (85%) positive biopsies. No complications related to the bioptic maneuver were found, according to CIRSE guidelines on percutaneous needle biopsy. CONCLUSIONS: Vertebral biopsy is a safe procedure with no related complications. In our series, an unexpected diagnosis was found in 6% of cases with impact on patient's clinical management. Positive unexpected histology was significantly higher in younger patients. In conclusion, we believe that a biopsy is useful and should be performed on all patients with vertebral compression fractures before a vertebroplasty.


Asunto(s)
Biopsia con Aguja/estadística & datos numéricos , Fracturas por Compresión/diagnóstico , Vértebras Lumbares/diagnóstico por imagen , Fracturas de la Columna Vertebral/diagnóstico , Vertebroplastia/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Fracturas por Compresión/cirugía , Humanos , Vértebras Lumbares/cirugía , Masculino , Persona de Mediana Edad , Periodo Preoperatorio , Estudios Retrospectivos , Fracturas de la Columna Vertebral/cirugía
2.
Pancreatology ; 19(4): 595-601, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31005377

RESUMEN

BACKGROUND: Pancreatico-enteric anastomosis after pancreaticoduodenectomy can be performed using either a pancreaticojejunostomy (PJ) or pancreaticogastrostomy (PG). Differences in surgical outcomes are still a matter of debate, and less is known about long-term functional outcomes. METHODS: Twelve years after the conclusion of a comparative study evaluating the surgical outcomes of PJ and PG (Bassi et al., Ann Surg 2005), available patients underwent morphological and functional pancreatic assessment: pancreatic volume and duct diameter measured by MRI, impaired secretion after secretin, fecal fat, fecal elastase-1 (FE-1), serum vitamin D and endocrine function. Quality of life and symptom scores were evaluated with the EORTC QLQ-C30 questionnaire. RESULTS: Only 34 patients were available for assessment. No differences were found in terms of BMI variation, endocrine function, quality of life or symptoms. Exocrine function was more severely impaired after PG than after PJ (fecal fats 26.6 ±â€¯4.1 vs 18.2 ±â€¯3.6 g/day; FE-1 121.4 ±â€¯6.7 vs 170.2 ±â€¯25.5 µg/g, vitamin D 18.1 ±â€¯1.8 vs. 23.2 ±â€¯3.1 ng/mL). MRI assessment identified a lower pancreatic volume (26 ±â€¯3.1 vs. 36 ±â€¯4.1 cm3) and a more dilated pancreatic duct (4.6 ±â€¯0.92 vs. 2.4 ±â€¯0.18 mm) in patients with PG compared to those with PJ. CONCLUSION: Compared to PJ, PG is associated with a more severely impaired exocrine function long-term, but they result similar endocrine function and quality of life. In patients with a long life expectancy, this should be taken into account.


Asunto(s)
Gastrostomía , Páncreas/fisiopatología , Páncreas/cirugía , Pancreaticoduodenectomía , Pancreatoyeyunostomía , Adulto , Anciano , Anastomosis Quirúrgica , Heces/química , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Páncreas/diagnóstico por imagen , Pruebas de Función Pancreática , Neoplasias Pancreáticas/cirugía , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/terapia , Calidad de Vida , Resultado del Tratamiento
3.
Pol J Radiol ; 82: 24-27, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28203308

RESUMEN

BACKGROUND: Pseudoaneurysm is a rare but potentially life-threatening vascular complication of acute pancreatitis, with a mortality rate of 20-43% in untreated patients. The treatment usually involves trans-arterial embolization or surgical resection. CASE REPORT: A 44-year-old man with a history of acute pancreatitis developed a pseudoaneurysm of the pancreatic tail, diagnosed as a splenic artery pseudoaneurysm by CT. Selective arteriography performed with the purpose of embolization did not reveal the pseudoaneurysm. The day after, under CT guidance, human thrombin (1,000 IU) was injected inside the aneurysmatic sac with its complete occlusion. A control MRI 6 months later confirmed a complete resolution of the pseudoaneurysm. CONCLUSIONS: Percutaneous coagulation of a post-pancreatitis pseudoaneurysm is a relatively easy and safe procedure, and it can be considered as an alternative to trans-arterial embolization when the pseudoaneurysm cannot be visualized on selective arteriography.

5.
Vasc Endovascular Surg ; 58(5): 530-534, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38153161

RESUMEN

This report demonstrates the successful treatment of a carotid artery pseudoaneurysm using percutaneous thrombin injection. The patient, a 62-year-old woman with multiple comorbidities, experienced a pseudoaneurysm following an unintentional carotid artery puncture during a failed attempt to place a triple lumen catheter in the right jugular vein. Percutaneous thrombin injection was chosen as the treatment method, with Doppler ultrasound monitoring. Follow-up examinations showed no signs of recurrence, and the patient was discharged after nine days without complications.


Asunto(s)
Traumatismos de las Arterias Carótidas , Enfermedad Iatrogénica , Punciones , Trombina , Lesiones del Sistema Vascular , Humanos , Trombina/administración & dosificación , Femenino , Persona de Mediana Edad , Resultado del Tratamiento , Traumatismos de las Arterias Carótidas/diagnóstico por imagen , Traumatismos de las Arterias Carótidas/tratamiento farmacológico , Traumatismos de las Arterias Carótidas/etiología , Lesiones del Sistema Vascular/diagnóstico por imagen , Lesiones del Sistema Vascular/etiología , Lesiones del Sistema Vascular/tratamiento farmacológico , Aneurisma Falso/diagnóstico por imagen , Aneurisma Falso/tratamiento farmacológico , Aneurisma Falso/etiología , Hemostáticos/administración & dosificación , Hemostáticos/efectos adversos , Cateterismo Venoso Central/efectos adversos , Cateterismo Venoso Central/instrumentación , Venas Yugulares/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Ultrasonografía Doppler
6.
Radiol Bras ; 55(4): 216-224, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35983340

RESUMEN

Objective: To promote advanced research using magnetic resonance imaging (MRI) in the diagnosis of and screening for osteoporosis by looking for correlations among the T-scores measured by dual-energy X-ray absorptiometry (DEXA), the apparent diffusion coefficient (ADC) values on diffusion-weighted imaging (DWI), and the T1-weighted signal intensity values. Materials and Methods: This was a prospective study of postmenopausal women with no contraindications to MRI and no history of cancer who underwent DEXA within 30 days before or after the MRI examination. A 3.0-T scanner was used in order to acquire sagittal sequences targeting the lumbar spine. Results: Thirteen women underwent DEXA and MRI. In two cases, the MRI was discontinued early. Therefore, the final sample comprised 11 patients. The ADC values and T1-weighted signal intensity were found to be higher in patients with osteoporosis. However, among the patients > 60 years of age with osteoporosis, ADC values were lower and T1-weighted signal intensity was even higher. Conclusion: It is unlikely that MRI will soon replace DEXA for the diagnostic workup of osteoporosis. Although DWI and ADC mapping are useful for understanding the pathophysiology of osteoporosis, we believe that T1-weighted sequences are more sensitive than is DWI as a means of performing a qualitative analysis of vertebral alterations.


Objetivo: Promover pesquisas avançadas usando ressonância magnética (RM) no diagnóstico e rastreamento de osteoporose, procurando correlações entre os escores T medidos por absorciometria de raios-X de dupla energia (DEXA), valores de coeficiente de difusão aparente (ADC) na difusão e valores de intensidade de sinal ponderado em T1. Materiais e Métodos: Estudo prospectivo de mulheres na pós-menopausa sem contraindicações para RM e sem histórico de câncer que foram submetidas a DEXA 30 dias antes ou após o exame de RM. Um scanner 3.0-T foi utilizado para adquirir sequências sagitais direcionadas à coluna lombar. Resultados: Treze mulheres foram submetidas a DEXA e RM. Em dois casos, a RM foi interrompida precocemente. Portanto, a amostra final foi composta por 11 pacientes. Os valores de ADC e intensidade de sinal ponderado em T1 foram mais elevados nas pacientes com osteoporose. No entanto, no subgrupo de pacientes > 60 anos de idade com osteoporose, os valores de ADC foram menores e a intensidade do sinal ponderado em T1 foi ainda maior. Conclusão: É improvável que a RM substitua DEXA para a investigação diagnóstica da osteoporose no futuro próximo. Embora a difusão e o mapeamento ADC sejam úteis para a compreensão da fisiopatologia da osteoporose, acreditamos que as sequências ponderadas em T1 são mais sensíveis do que a difusão como meio de realizar uma análise qualitativa das alterações vertebrais.

7.
Front Endocrinol (Lausanne) ; 12: 766253, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34707574

RESUMEN

Introduction: Magnetic Resonance Imaging (MRI) is the best approach to investigate the hypothalamic-pituitary region in children with central precocious puberty (CPP). Routine scanning is controversial in girls aged 6-8 year, due to the overwhelming prevalence of idiopathic forms and unrelated incidentalomas. Cerebral lipomas are rare and accidental findings, not usually expected in CPP. We report a girl with CPP and an unusually shaped posterior pituitary gland on SE-T1w sequences. Case Description: A 7.3-year-old female was referred for breast development started at age 7. Her past medical history and physical examination were unremarkable, apart from the Tanner stage 2 breast. X-ray of the left-hand revealed a bone age 2-years ahead of her chronological age, projecting her adult height prognosis below the mid parental height. LHRH test and pelvic ultrasound were suggestive for CPP. Routine brain MRI sequences, SE T1w and TSE T2w, showed the posterior pituitary bright spot increased in size and stretched upward. The finding was considered as an anatomical variant, in an otherwise normal brain imaging. Patient was started on treatment with GnRH analogue. At a thorough revaluation, imaging overlap with adipose tissue was suspected and a new MRI scan with 3D-fat-suppression T1w-VIBE sequences demonstrated a lipoma of the tuber cinereum, bordering a perfectly normal neurohypophysis. 3D-T2w-SPACE sequences, acquired at first MRI scan, would have provided a more correct interpretation if rightly considered. Conclusion: This is the first evidence, to our knowledge, of a cerebral lipoma mimicking pituitary gland abnormalities. Our experience highlights the importance of considering suprasellar lipomas in the MRI investigation of children with CPP, despite their rarity, should the T1w sequences show an unexpected pituitary shape. 3D-T2w SPACE sequences could be integrated into standard ones, especially when performing MRI routinely, to avoid potential misinterpretations.


Asunto(s)
Lipoma/patología , Hipófisis/patología , Pubertad Precoz/patología , Tuber Cinereum/patología , Niño , Femenino , Hormona Liberadora de Gonadotropina/metabolismo , Humanos , Hipotálamo/metabolismo , Hipotálamo/patología , Lipoma/metabolismo , Hipófisis/metabolismo , Pubertad Precoz/metabolismo , Tuber Cinereum/metabolismo
8.
Vasc Endovascular Surg ; 54(7): 643-645, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32638641

RESUMEN

A 78-year-old male patient was admitted to our hospital after abdominal trauma. Contrast-enhanced computed tomography (CT) scan demonstrated a horseshoe kidney with a perinephric hematoma and evidence of arterial hemorrhage. An anomalous renal arterial anatomy was noted as well, with a renal artery originating from the left common iliac artery. He was successfully treated via an endovascular approach. Varying forms of vascularization may complicate angiographic treatment of patients with abdominal trauma in a setting of kidney anomalies. Obtaining and evaluating contrast-enhanced CT angiography can identify anomalous vessels and can be invaluable when deciding on the most appropriate interventional approach.


Asunto(s)
Traumatismos Abdominales/terapia , Accidentes por Caídas , Embolización Terapéutica , Procedimientos Endovasculares , Riñón Fusionado/complicaciones , Riñón/lesiones , Laceraciones/terapia , Arteria Renal/lesiones , Lesiones del Sistema Vascular/terapia , Heridas no Penetrantes/terapia , Traumatismos Abdominales/diagnóstico por imagen , Traumatismos Abdominales/etiología , Anciano , Embolización Terapéutica/instrumentación , Procedimientos Endovasculares/instrumentación , Riñón Fusionado/diagnóstico por imagen , Humanos , Riñón/diagnóstico por imagen , Laceraciones/diagnóstico por imagen , Laceraciones/etiología , Masculino , Arteria Renal/anomalías , Arteria Renal/diagnóstico por imagen , Resultado del Tratamiento , Lesiones del Sistema Vascular/diagnóstico por imagen , Lesiones del Sistema Vascular/etiología , Heridas no Penetrantes/diagnóstico por imagen , Heridas no Penetrantes/etiología
9.
Radiol. bras ; Radiol. bras;55(4): 216-224, Aug. 2022. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1394568

RESUMEN

Abstract Objective: To promote advanced research using magnetic resonance imaging (MRI) in the diagnosis of and screening for osteoporosis by looking for correlations among the T-scores measured by dual-energy X-ray absorptiometry (DEXA), the apparent diffusion coefficient (ADC) values on diffusion-weighted imaging (DWI), and the T1-weighted signal intensity values. Materials and Methods: This was a prospective study of postmenopausal women with no contraindications to MRI and no history of cancer who underwent DEXA within 30 days before or after the MRI examination. A 3.0-T scanner was used in order to acquire sagittal sequences targeting the lumbar spine. Results: Thirteen women underwent DEXA and MRI. In two cases, the MRI was discontinued early. Therefore, the final sample comprised 11 patients. The ADC values and T1-weighted signal intensity were found to be higher in patients with osteoporosis. However, among the patients > 60 years of age with osteoporosis, ADC values were lower and T1-weighted signal intensity was even higher. Conclusion: It is unlikely that MRI will soon replace DEXA for the diagnostic workup of osteoporosis. Although DWI and ADC mapping are useful for understanding the pathophysiology of osteoporosis, we believe that T1-weighted sequences are more sensitive than is DWI as a means of performing a qualitative analysis of vertebral alterations.


Resumo Objetivo: Promover pesquisas avançadas usando ressonância magnética (RM) no diagnóstico e rastreamento de osteoporose, procurando correlações entre os escores T medidos por absorciometria de raios-X de dupla energia (DEXA), valores de coeficiente de difusão aparente (ADC) na difusão e valores de intensidade de sinal ponderado em T1. Materiais e Métodos: Estudo prospectivo de mulheres na pós-menopausa sem contraindicações para RM e sem histórico de câncer que foram submetidas a DEXA 30 dias antes ou após o exame de RM. Um scanner 3.0-T foi utilizado para adquirir sequências sagitais direcionadas à coluna lombar. Resultados: Treze mulheres foram submetidas a DEXA e RM. Em dois casos, a RM foi interrompida precocemente. Portanto, a amostra final foi composta por 11 pacientes. Os valores de ADC e intensidade de sinal ponderado em T1 foram mais elevados nas pacientes com osteoporose. No entanto, no subgrupo de pacientes > 60 anos de idade com osteoporose, os valores de ADC foram menores e a intensidade do sinal ponderado em T1 foi ainda maior. Conclusão: É improvável que a RM substitua DEXA para a investigação diagnóstica da osteoporose no futuro próximo. Embora a difusão e o mapeamento ADC sejam úteis para a compreensão da fisiopatologia da osteoporose, acreditamos que as sequências ponderadas em T1 são mais sensíveis do que a difusão como meio de realizar uma análise qualitativa das alterações vertebrais.

SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda