RESUMEN
Stroke recovery trajectories vary substantially. The need for tracking and prognostic biomarkers in stroke is utmost for prognostic and rehabilitative goals: electroencephalography (EEG) advanced signal analysis may provide useful tools toward this aim. EEG microstates quantify changes in configuration of neuronal generators of short-lasting periods of coordinated synchronized communication within large-scale brain networks: this feature is expected to be impaired in stroke. To characterize the spatio-temporal signatures of EEG microstates in stroke survivors in the acute/subacute phase, EEG microstate analysis was performed in 51 first-ever ischemic stroke survivors [(28-82) years, 24 with right hemisphere (RH) lesion] who underwent a resting-state EEG recording in the acute and subacute phase (from 48 h up to 42 days after the event). Microstates were characterized based on 4 parameters: global explained variance (GEV), mean duration, occurrences per second, and percentage of coverage. Wilcoxon Rank Sum tests were performed to compare features of each microstate across the two groups [i.e., left hemisphere (LH) and right hemisphere (RH) stroke survivors]. The canonical microstate map D, characterized by a mostly frontal topography, displayed greater GEV, occurrence per second, and percentage of coverage in LH than in RH stroke survivors (p < 0.05). The EEG microstate map B, with a left-frontal to right-posterior topography, and F, with an occipital-to-frontal topography, exhibited a greater GEV in RH than in LH stroke survivors (p = 0.015). EEG microstates identified specific topographic maps which characterize stroke survivors' lesioned hemisphere in the acute and early subacute phase. Microstate features offer an additional tool to identify different neural reorganization.
Asunto(s)
Electroencefalografía , Accidente Cerebrovascular , Humanos , Encéfalo/fisiología , Mapeo Encefálico , PronósticoRESUMEN
AIM: Treatment algorithms define lines of glucose lowering medications (GLM) for the management of type 2 diabetes (T2D), but whether therapeutic trajectories are associated with major adverse cardiovascular events (MACE) is unclear. We explored whether the temporal resolution of GLM usage discriminates patients who experienced a 4P-MACE (heart failure, myocardial infarction, stroke, death for all causes). METHODS: We used an administrative database (Veneto region, North-East Italy, 2011-2018) and implemented recurrent neural networks (RNN) with outcome-specific attention maps. The model input included age, sex, diabetes duration, and a matrix of GLM pattern before the 4P-MACE or censoring. Model output was discrimination, reported as area under receiver characteristic curve (AUROC). Attention maps were produced to show medications whose time-resolved trajectories were the most important for discrimination. RESULTS: The analysis was conducted on 147,135 patients for training and model selection and on 10,000 patients for validation. Collected data spanned a period of ~ 6 years. The RNN model efficiently discriminated temporal patterns of GLM ending in a 4P-MACE vs. those ending in an event-free censoring with an AUROC of 0.911 (95% C.I. 0.904-0.919). This excellent performance was significantly better than that of other models not incorporating time-resolved GLM trajectories: (i) a logistic regression on the bag-of-words encoding all GLM ever taken by the patient (AUROC 0.754; 95% C.I. 0.743-0.765); (ii) a model including the sequence of GLM without temporal relationships (AUROC 0.749; 95% C.I. 0.737-0.761); (iii) a RNN model with the same construction rules but including a time-inverted or randomised order of GLM. Attention maps identified the time-resolved pattern of most common first-line (metformin), second-line (sulphonylureas) GLM, and insulin (glargine) as those determining discrimination capacity. CONCLUSIONS: The time-resolved pattern of GLM use identified patients with subsequent cardiovascular events better than the mere list or sequence of prescribed GLM. Thus, a patient's therapeutic trajectory could determine disease outcomes.
Asunto(s)
Enfermedades Cardiovasculares , Diabetes Mellitus Tipo 2 , Infarto del Miocardio , Enfermedades Cardiovasculares/diagnóstico , Enfermedades Cardiovasculares/tratamiento farmacológico , Enfermedades Cardiovasculares/epidemiología , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Diabetes Mellitus Tipo 2/epidemiología , Glucosa , Humanos , Hipoglucemiantes/efectos adversos , Infarto del Miocardio/complicaciones , Redes Neurales de la ComputaciónRESUMEN
BACKGROUND: Results of cardiovascular outcome trials enabled a shift from "treat-to-target" to "treat-to-benefit" paradigm in the management of type 2 diabetes (T2D). However, studies validating such approach are limited. Here, we examined whether treatment according to international recommendations for the pharmacological management of T2D had an impact on long-term outcomes. METHODS: This was an observational study conducted on outpatient data collected in 2008-2018 (i.e. prior to the "treat-to-benefit" shift). We defined 6 domains of treatment based on the ADA/EASD consensus covering all disease stages: first- and second-line treatment, intensification, use of insulin, cardioprotective, and weight-affecting drugs. At each visit, patients were included in Group 1 if at least one domain deviated from recommendation or in Group 2 if aligned with recommendations. We used Cox proportional hazard models with time-dependent co-variates or Cox marginal structural models (with inverse-probability of treatment weighing evaluated at each visit) to adjust for confounding factors and evaluate three outcomes: major adverse cardiovascular events (MACE), hospitalization for heart failure or cardiovascular mortality (HF-CVM), and all-cause mortality. RESULTS: We included 5419 patients, on average 66-year old, 41% women, with a baseline diabetes duration of 7.6 years. Only 11.7% had pre-existing cardiovascular disease. During a median follow-up of 7.3 years, patients were seen 12 times at the clinic, and we recorded 1325 MACE, 1593 HF-CVM, and 917 deaths. By the end of the study, each patient spent on average 63.6% of time in Group 1. In the fully adjusted model, being always in Group 2 was associated with a 45% lower risk of MACE (HR 0.55; 95% C.I. 0.46-0.66; p < 0.0001) as compared to being in Group 1. The corresponding HF-CVM and mortality risk were similar (HR 0.56; 95%CI 0.47-0.66, p < 0.0001 and HR 0.56; 95% C.I. 0.45-0.70; p < 0.0001. respectively). Sensitivity analyses confirmed these results. No single domain individually explained the better outcome of Group 2, which remained significant in all subgroups. CONCLUSION: Managing patients with T2D according to a "treat-to-benefit" approach based international standards was associated with a lower risk of MACE, heart failure, and mortality. These data provide ex-post validation of the ADA/EASD treatment algorithm.
Asunto(s)
Enfermedades Cardiovasculares , Diabetes Mellitus Tipo 2 , Insuficiencia Cardíaca , Humanos , Femenino , Anciano , Masculino , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Diabetes Mellitus Tipo 2/complicaciones , Hospitalización , Insulina/uso terapéutico , Modelos de Riesgos Proporcionales , Enfermedades Cardiovasculares/diagnóstico , Enfermedades Cardiovasculares/prevención & control , Enfermedades Cardiovasculares/complicaciones , Hipoglucemiantes/efectos adversosRESUMEN
AIMS: Reliable estimation of the time spent in different glycaemic ranges (time-in-ranges) requires sufficiently long continuous glucose monitoring. In a 2019 paper (Battelino et al., Clinical targets for continuous glucose monitoring data interpretation: recommendations from the international consensus on time in range. Diabetes Care. 2019;42:1593-1603), an international panel of experts suggested using a correlation-based approach to obtain the minimum number of days for reliable time-in-ranges estimates. More recently (in Camerlingo et al., Design of clinical trials to assess diabetes treatment: minimum duration of continuous glucose monitoring data to estimate time-in-ranges with the desired precision. Diabetes Obes Metab. 2021;23:2446-2454) we presented a mathematical equation linking the number of monitoring days to the uncertainty around time-in-ranges estimates. In this work, we compare these two approaches, mainly focusing on time spent in (70-180) mg/dL range (TIR). METHODS: The first 100 and 150 days of data were extracted from study A (148 subjects, ~180 days), and the first 100, 150, 200, 250 and 300 days of data from study B (45 subjects, ~365 days). For each of these data windows, the minimum monitoring duration was computed using correlation-based and equation-based approaches. The suggestions were compared for the windows of different durations extracted from the same study, and for the windows of equal duration extracted from different studies. RESULTS: When changing the dataset duration, the correlation-based approach produces inconsistent results, ranging from 23 to 64 days, for TIR. The equation-based approach was found to be robust versus this issue, as it is affected only by the characteristics of the population being monitored. Indeed, to grant a confidence interval of 5% around TIR, it suggests 18 days for windows from study A, and 17 days for windows from study B. Similar considerations hold for other time-in-ranges. CONCLUSIONS: The equation-based approach offers advantages for the design of clinical trials having time-in-ranges as final end points, with focus on trial duration.
Asunto(s)
Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1 , Glucemia , Automonitorización de la Glucosa Sanguínea/métodos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Humanos , Factores de TiempoRESUMEN
Accurate blood glucose (BG) forecasting is key in diabetes management, as it allows preventive actions to mitigate harmful hypoglycemic/hyperglycemic episodes. Considering the encouraging results obtained by seasonal stochastic models in proof-of-concept studies, this work assesses the methodology in two datasets (open-loop and closed-loop) recorded in free-living conditions. First, similar postprandial glycemic profiles are grouped together with fuzzy C-means clustering. Then, a seasonal stochastic model is identified for each cluster. Finally, real-time BG forecasting is performed by weighting each model's prediction. The proposed methodology (named C-SARIMA) is compared to other linear and nonlinear black-box methods: autoregressive integrated moving average (ARIMA), its variant with input (ARIMAX), a feed-forward neural network (NN), and its modified version (NN-X) fed by BG, insulin, and carbohydrates (timing and dosing) information for several prediction horizons (PHs). In the open-loop dataset, C-SARIMA grants a median root-mean-squared error (RMSE) of 20.13 mg/dL (PH = 30) and 27.23 mg/dL (PH = 45), not significantly different from ARIMA and NN. Over a longer PH, C-SARIMA achieves an RMSE = 31.96 mg/dL (PH = 60) and RMSE = 33.91 mg/dL (PH = 75), significantly outperforming the ARIMA and NN, without significant differences from the ARIMAX for PH ≥ 45 and the NN-X for PH ≥ 60. Similar results hold on the closed-loop dataset: for PH = 30 and 45 min, the C-SARIMA achieves an RMSE = 21.63 mg/dL and RMSE = 29.67 mg/dL, not significantly different from the ARIMA and NN. On longer PH, the C-SARIMA outperforms the ARIMA for PH > 45 and the NN for PH > 60 without significant differences from the ARIMAX for PH ≥ 45. Although using less input information, the C-SARIMA achieves similar performance to other prediction methods such as the ARIMAX and NN-X and outperforming the CGM-only approaches on PH > 45min.
Asunto(s)
Glucosa , Hipoglucemia , Humanos , Condiciones Sociales , Estaciones del Año , Comidas , GlucemiaRESUMEN
AIM: We aimed to compare cardiovascular outcomes of patients with type 2 diabetes (T2D) who initiated GLP-1 receptor agonists (GLP-1RA) or basal insulin (BI) under routine care. METHODS: We accessed the administrative claims database of the Veneto Region (Italy) to identify new users of GLP-1RA or BI in 2014-2018. Propensity score matching (PSM) was implemented to obtain two cohorts of patients with superimposable characteristics. The primary endpoint was the 3-point major adverse cardiovascular events (3P-MACE). Secondary endpoints included 3P-MACE components, hospitalization for heart failure, revascularizations, and adverse events. RESULTS: From a background population of 5,242,201 citizens, 330,193 were identified as having diabetes. PSM produced two very well matched cohorts of 4063 patients each, who initiated GLP-1RA or BI after an average of 2.5 other diabetes drug classes. Patients were 63-year-old and only 15% had a baseline history of cardiovascular disease. During a median follow-up of 24 months in the intention-to-treat analysis, 3P-MACE occurred less frequently in the GLP-1RA cohort (HR versus BI 0.59; 95% CI 0.50-0.71; p < 0.001). All secondary cardiovascular endpoints were also significantly in favor of GLP-1RA. Results were confirmed in the as-treated approach and in several stratified analyses. According to the E-value, confounding by unmeasured variables were unlikely to entirely explain between-group differences in cardiovascular outcomes. CONCLUSIONS: Patients with T2D who initiated a GLP-1RA experienced far better cardiovascular outcomes than did matched patients who initiated a BI in the same healthcare system. These finding supports prioritization of GLP-1RA as the first injectable regimen for the management of T2D.
Asunto(s)
Enfermedades Cardiovasculares/prevención & control , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Receptor del Péptido 1 Similar al Glucagón/agonistas , Hipoglucemiantes/uso terapéutico , Incretinas/uso terapéutico , Insulina/uso terapéutico , Reclamos Administrativos en el Cuidado de la Salud , Anciano , Anciano de 80 o más Años , Enfermedades Cardiovasculares/diagnóstico , Enfermedades Cardiovasculares/epidemiología , Investigación sobre la Eficacia Comparativa , Bases de Datos Factuales , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/epidemiología , Femenino , Humanos , Hipoglucemiantes/efectos adversos , Incretinas/efectos adversos , Insulina/efectos adversos , Italia/epidemiología , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Tiempo , Resultado del TratamientoRESUMEN
AIM: To compute the uncertainty of time-in-ranges, such as time in range (TIR), time in tight range (TITR), time below range (TBR) and time above range (TAR), to evaluate glucose control and to determine the minimum duration of a trial to achieve the desired precision. MATERIALS AND METHODS: Four formulas for the aforementioned time-in-ranges were obtained by estimating the equation's parameters on a training set extracted from study A (226 subjects, ~180 days, 5-minute Dexcom G4 Platinum sensor). The formulas were then validated on the remaining data. We also illustrate how to adjust the parameters for sensors with different sampling rates. Finally, we used study B (45 subjects, ~365 days, 15-minute Abbott Freestyle Libre sensor) to further validate our results. RESULTS: Our approach was effective in predicting the uncertainty when time-in-ranges are estimated using n days of continuous glucose monitoring (CGM), matching the variability observed in the data. As an example, monitoring a population with TIR = 70%, TITR = 50%, TBR = 5% and TAR = 25% for 30 days warrants a precision of ±3.50%, ±3.68%, ±1.33% and ±3.66%, respectively. CONCLUSIONS: The presented approach can be used to both compute the uncertainty of time-in-ranges and determine the minimum duration of a trial to achieve the desired precision. An online tool to facilitate its implementation is made freely available to the clinical investigator.
Asunto(s)
Glucemia , Diabetes Mellitus Tipo 1 , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Humanos , Factores de TiempoRESUMEN
In type 1 diabetes management, the availability of algorithms capable of accurately forecasting future blood glucose (BG) concentrations and hypoglycemic episodes could enable proactive therapeutic actions, e.g., the consumption of carbohydrates to mitigate, or even avoid, an impending critical event. The only input of this kind of algorithm is often continuous glucose monitoring (CGM) sensor data, because other signals (such as injected insulin, ingested carbs, and physical activity) are frequently unavailable. Several predictive algorithms fed by CGM data only have been proposed in the literature, but they were assessed using datasets originated by different experimental protocols, making a comparison of their relative merits difficult. The aim of the present work was to perform a head-to-head comparison of thirty different linear and nonlinear predictive algorithms using the same dataset, given by 124 CGM traces collected over 10 days with the newest Dexcom G6 sensor available on the market and considering a 30-min prediction horizon. We considered the state-of-the art methods, investigating, in particular, linear black-box methods (autoregressive; autoregressive moving-average; and autoregressive integrated moving-average, ARIMA) and nonlinear machine-learning methods (support vector regression, SVR; regression random forest; feed-forward neural network, fNN; and long short-term memory neural network). For each method, the prediction accuracy and hypoglycemia detection capabilities were assessed using either population or individualized model parameters. As far as prediction accuracy is concerned, the results show that the best linear algorithm (individualized ARIMA) provides accuracy comparable to that of the best nonlinear algorithm (individualized fNN), with root mean square errors of 22.15 and 21.52 mg/dL, respectively. As far as hypoglycemia detection is concerned, the best linear algorithm (individualized ARIMA) provided precision = 64%, recall = 82%, and one false alarm/day, comparable to the best nonlinear technique (population SVR): precision = 63%, recall = 69%, and 0.5 false alarms/day. In general, the head-to-head comparison of the thirty algorithms fed by CGM data only made using a wide dataset shows that individualized linear models are more effective than population ones, while no significant advantages seem to emerge when employing nonlinear methodologies.
Asunto(s)
Automonitorización de la Glucosa Sanguínea , Glucemia/análisis , Hipoglucemia , Algoritmos , Humanos , Hipoglucemia/diagnósticoRESUMEN
BACKGROUND: Cardiovascular outcome trials in high-risk patients showed that some GLP-1 receptor agonists (GLP-1RA), but not dipeptidyl-peptidase-4 inhibitors (DPP-4i), can prevent cardiovascular events in type 2 diabetes (T2D). Since no trial has directly compared these two classes of drugs, we performed a comparative outcome analysis using real-world data. METHODS: From a database of ~ 5 million people from North-East Italy, we retrospectively identified initiators of GLP-1RA or DPP-4i from 2011 to 2018. We obtained two balanced cohorts by 1:1 propensity score matching. The primary outcome was the 3-point major adverse cardiovascular events (3P-MACE; a composite of death, myocardial infarction, or stroke). 3P-MACE components and hospitalization for heart failure were secondary outcomes. RESULTS: From 330,193 individuals with T2D, we extracted two matched cohorts of 2807 GLP-1RA and 2807 DPP-4i initiators, followed for a median of 18 months. On average, patients were 63 years old, 60% male; 15% had pre-existing cardiovascular disease. The rate of 3P-MACE was lower in patients treated with GLP-1RA compared to DPP4i (23.5 vs. 34.9 events per 1000 person-years; HR: 0.67; 95% C.I. 0.53-0.86; p = 0.002). Rates of myocardial infarction (HR 0.67; 95% C.I. 0.50-0.91; p = 0.011) and all-cause death (HR 0.58; 95% C.I. 0.35-0.96; p = 0.034) were lower among GLP-1RA initiators. The as-treated and intention-to-treat approaches yielded similar results. CONCLUSIONS: Patients initiating a GLP-1RA in clinical practice had better cardiovascular outcomes than similar patients who initiated a DPP-4i. These data strongly confirm findings from cardiovascular outcome trials in a lower risk population.
Asunto(s)
Enfermedades Cardiovasculares/prevención & control , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Inhibidores de la Dipeptidil-Peptidasa IV/uso terapéutico , Receptor del Péptido 1 Similar al Glucagón/agonistas , Incretinas/uso terapéutico , Anciano , Enfermedades Cardiovasculares/diagnóstico , Enfermedades Cardiovasculares/mortalidad , Causas de Muerte , Bases de Datos Factuales , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/mortalidad , Inhibidores de la Dipeptidil-Peptidasa IV/efectos adversos , Femenino , Humanos , Incretinas/efectos adversos , Italia/epidemiología , Masculino , Persona de Mediana Edad , Admisión del Paciente , Factores Protectores , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del TratamientoRESUMEN
AIM: Concerns have been raised that dipeptidyl-peptidase 4 inhibitors (DPP-4i) may increase the risk of pneumonia. We analysed observational data and clinical trials to explore whether use of DPP-4i modifies the risk of pneumonia. METHODS: We identified patients with diabetes in the Veneto region administrative database and performed propensity score matching between new users of DPP-4 inhibitors and new users of other oral glucose-lowering medications (OGLMs). We compared the rate of hospitalization for pneumonia between matched cohorts using the Cox proportional hazard model. The same analysis was repeated using the database of a local diabetes outpatient clinic. We retrieved similar observational studies from the literature to perform a meta-analysis. Results from trials reporting pneumonia rates among patients randomized to DPP-4 inhibitors versus placebo/active comparators were also meta-analysed. RESULTS: In the regional database, after matching 6495 patients/group, new users of DPP-4 inhibitors had a lower rate of hospitalization for pneumonia than new users of other OGLMs (HR 0.76; 95% CI 0.61-0.95). In the outpatient database, after matching 867 patients/group, new users of DPP-4 inhibitors showed a non-significantly lower rate of hospitalization for pneumonia (HR 0.65; 95% CI 0.41-1.04). The meta-analysis of observational studies yielded an overall non-significant lower risk of hospitalization for pneumonia among DPP-4 inhibitor users (RR 0.81; 95% CI 0.65-1.01). The meta-analysis of randomized controlled trials showed no overall effect of DPP-4 inhibitors on pneumonia risk (RR 1.06; 95% CI 0.93-1.20). CONCLUSION: The use of DPP-4 inhibitors can be considered as safe with regard to the risk of pneumonia.
Asunto(s)
Diabetes Mellitus Tipo 2 , Inhibidores de la Dipeptidil-Peptidasa IV , Neumonía , Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Diabetes Mellitus Tipo 2/epidemiología , Inhibidores de la Dipeptidil-Peptidasa IV/efectos adversos , Humanos , Hipoglucemiantes/efectos adversos , Neumonía/epidemiología , Ensayos Clínicos Controlados Aleatorios como Asunto , Estudios Retrospectivos , Factores de RiesgoRESUMEN
Because other coronaviruses enter the cells by binding to dipeptidyl-peptidase-4 (DPP-4), it has been speculated that DPP-4 inhibitors (DPP-4is) may exert an activity against severe acute respiratory syndrome coronavirus 2. In the absence of clinical trial results, we analysed epidemiological data to support or discard such a hypothesis. We retrieved information on exposure to DPP-4is among patients with type 2 diabetes (T2D) hospitalized for COVID-19 at an outbreak hospital in Italy. As a reference, we retrieved information on exposure to DPP-4is among matched patients with T2D in the same region. Of 403 hospitalized COVID-19 patients, 85 had T2D. The rate of exposure to DPP-4is was similar between T2D patients with COVID-19 (10.6%) and 14 857 matched patients in the region (8.8%), or 793 matched patients in the local outpatient clinic (15.4%), 8284 matched patients hospitalized for other reasons (8.5%), and when comparing 71 patients hospitalized for COVID-19 pneumonia (11.3%) with 351 matched patients with pneumonia of another aetiology (10.3%). T2D patients with COVID-19 who were on DPP-4is had a similar disease outcome as those who were not. In summary, we found no evidence that DPP-4is might affect hospitalization for COVID-19.
Asunto(s)
COVID-19/complicaciones , COVID-19/epidemiología , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Diabetes Mellitus Tipo 2/epidemiología , Inhibidores de la Dipeptidil-Peptidasa IV/uso terapéutico , Anciano , Anciano de 80 o más Años , COVID-19/diagnóstico , Estudios de Casos y Controles , Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 2/diagnóstico , Brotes de Enfermedades , Femenino , Hospitalización/estadística & datos numéricos , Humanos , Italia/epidemiología , Masculino , Persona de Mediana Edad , Pandemias , Pronóstico , Estudios Retrospectivos , SARS-CoV-2/efectos de los fármacos , SARS-CoV-2/fisiologíaRESUMEN
BACKGROUND AND AIMS: Diabetes can often remain undiagnosed or unregistered in administrative databases long after its onset, even when laboratory test results meet diagnostic criteria. In the present work, we analyse healthcare data of the Veneto Region, North East Italy, with the aims of: (i) developing an algorithm for the identification of diabetes from administrative claims (4,236,007 citizens), (ii) assessing its reliability by comparing its performance with the gold standard clinical diagnosis from a clinical database (7525 patients), (iii) combining the algorithm and the laboratory data of the regional Health Information Exchange (rHIE) system (543,520 subjects) to identify undiagnosed diabetes, and (iv) providing a credible estimate of the true prevalence of diabetes in Veneto. METHODS AND RESULTS: The proposed algorithm for the identification of diabetes was fed by administrative data related to drug dispensations, outpatient visits, and hospitalisations. Evaluated against a clinical database, the algorithm achieved 95.7% sensitivity, 87.9% specificity, and 97.6% precision. To identify possible cases of undiagnosed diabetes, we applied standard diagnostic criteria to the laboratory test results of the subjects who, according to the algorithm, had no diabetes-related claims. Using a simplified probabilistic model, we corrected our claims-based estimate of known diabetes (6.17% prevalence; 261,303 cases) to account for undiagnosed cases, yielding an estimated total prevalence of 7.50%. CONCLUSION: We herein validated an algorithm for the diagnosis of diabetes using administrative claims against the clinical diagnosis. Together with rHIE laboratory data, this allowed to identify possibly undiagnosed diabetes and estimate the true prevalence of diabetes in Veneto.
Asunto(s)
Reclamos Administrativos en el Cuidado de la Salud , Minería de Datos/métodos , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Niño , Preescolar , Bases de Datos Factuales , Femenino , Humanos , Lactante , Recién Nacido , Italia/epidemiología , Masculino , Persona de Mediana Edad , Prevalencia , Reproducibilidad de los Resultados , Adulto JovenRESUMEN
Wearable continuous glucose monitoring (CGM) sensors are revolutionizing the treatment of type 1 diabetes (T1D). These sensors provide in real-time, every 1-5 min, the current blood glucose concentration and its rate-of-change, two key pieces of information for improving the determination of exogenous insulin administration and the prediction of forthcoming adverse events, such as hypo-/hyper-glycemia. The current research in diabetes technology is putting considerable effort into developing decision support systems for patient use, which automatically analyze the patient's data collected by CGM sensors and other portable devices, as well as providing personalized recommendations about therapy adjustments to patients. Due to the large amount of data collected by patients with T1D and their variety, artificial intelligence (AI) techniques are increasingly being adopted in these decision support systems. In this paper, we review the state-of-the-art methodologies using AI and CGM sensors for decision support in advanced T1D management, including techniques for personalized insulin bolus calculation, adaptive tuning of bolus calculator parameters and glucose prediction.
Asunto(s)
Inteligencia Artificial , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 1/terapia , Dispositivos Electrónicos Vestibles , Glucemia/análisis , Manejo de la Enfermedad , Humanos , Sistemas de Infusión de InsulinaRESUMEN
Previous literature has demonstrated that hypoglycemic events in patients with type 1 diabetes (T1D) are associated with measurable scalp electroencephalography (EEG) changes in power spectral density. In the present study, we used a dataset of 19-channel scalp EEG recordings in 34 patients with T1D who underwent a hyperinsulinemic-hypoglycemic clamp study. We found that hypoglycemic events are also characterized by EEG complexity changes that are quantifiable at the single-channel level through empirical conditional and permutation entropy and fractal dimension indices, i.e., the Higuchi index, residuals, and tortuosity. Moreover, we demonstrated that the EEG complexity indices computed in parallel in more than one channel can be used as the input for a neural network aimed at identifying hypoglycemia and euglycemia. The accuracy was about 90%, suggesting that nonlinear indices applied to EEG signals might be useful in revealing hypoglycemic events from EEG recordings in patients with T1D.
RESUMEN
BACKGROUND: Complication screening is recommended for patients with type 2 diabetes (T2D), but the optimal screening intensity and schedules are unknown. In this study, we evaluated whether intensive versus standard complication screening affects long-term cardiovascular outcomes. METHODS: In this observational study, we included 368 T2D patients referred for intensive screening provided as a 1-day session of clinical-instrumental evaluation of diabetic complications, followed by dedicated counseling. From a total of 4906 patients, we selected control T2D patients who underwent standard complication screening at different visits, by 2:1 propensity score matching. The primary endpoint was the 4p-MACE, defined as cardiovascular mortality, or non-fatal myocardial infarction, stroke, or heart failure. The Cox proportional regression analyses was used to compare outcome occurrence in the two groups, adjusted for residual confounders. RESULTS: 357 patients from the intensive screening group (out of 368) were matched with 683 patients in the standard screening group. Clinical characteristics were well balanced between the two groups, except for a slightly higher prevalence of microangiopathy in the intensive group (56% vs 50%; standardized mean difference 0.11, p = 0.1). Median follow-up was 5.6 years. The adjusted incidence of 4p-MACE was significantly lower in the intensive versus standard screening group (HR 0.70; 95% CI 0.52-0.95; p = 0.02). All components of the primary endpoint had nominally lower rates in the intensive versus standard screening group, which was particularly significant for heart failure (HR 0.43; 95% CI 0.22-0.83; p = 0.01). CONCLUSION: Among T2D patients attending a specialist outpatient clinic, intensive complication screening is followed by better long-term cardiovascular outcomes. No significant effect was noted for cardiovascular and all-cause mortality and the benefit was mainly driven by a reduced rate of hospitalization for heart failure.
Asunto(s)
Enfermedades Cardiovasculares/epidemiología , Complicaciones de la Diabetes/diagnóstico , Diabetes Mellitus Tipo 2/diagnóstico , Anciano , Atención Ambulatoria , Enfermedades Cardiovasculares/diagnóstico , Enfermedades Cardiovasculares/mortalidad , Enfermedades Cardiovasculares/prevención & control , Complicaciones de la Diabetes/mortalidad , Complicaciones de la Diabetes/terapia , Diabetes Mellitus Tipo 2/mortalidad , Diabetes Mellitus Tipo 2/terapia , Progresión de la Enfermedad , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/epidemiología , Humanos , Incidencia , Italia/epidemiología , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/epidemiología , Pronóstico , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/epidemiología , Factores de TiempoRESUMEN
Factory-calibrated continuous glucose monitoring (FC-CGM) sensors are new devices used in type 1 diabetes (T1D) therapy to measure the glucose concentration almost continuously for 10-14 days without requiring any in vivo calibration. Understanding and modelling CGM errors is important when designing new tools for T1D therapy. Available literature CGM error models are not suitable to describe the FC-CGM sensor error, since their domain of validity is limited to 12-h time windows, i.e., the time between two consecutive in vivo calibrations. The aim of this paper is to develop a model of the error of FC-CGM sensors. The dataset used contains 79 FC-CGM traces collected by the Dexcom G6 sensor. The model is designed to dissect the error into its three main components: effect of plasma-interstitium kinetics, calibration error, and random measurement noise. The main novelties are the model extension to cover the entire sensor lifetime and the use of a new single-step identification procedure. The final error model, which combines a first-order linear dynamic model to describe plasma-interstitium kinetics, a second-order polynomial model to describe calibration error, and an autoregressive model to describe measurement noise, proved to be suitable to describe FC-CGM sensor errors, in particular improving the estimation of the physiological time-delay.
Asunto(s)
Automonitorización de la Glucosa Sanguínea/instrumentación , Glucemia/análisis , Diabetes Mellitus Tipo 1/sangre , Sistemas de Infusión de Insulina , Algoritmos , Teorema de Bayes , Calibración , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Humanos , Cinética , Estudios Longitudinales , Modelos Teóricos , Reproducibilidad de los ResultadosRESUMEN
Even if still at an early stage of development, non-invasive continuous glucose monitoring (NI-CGM) sensors represent a promising technology for optimizing diabetes therapy. Recent studies showed that the Multisensor provides useful information about glucose dynamics with a mean absolute relative difference (MARD) of 35.4% in a fully prospective setting. Here we propose a method that, exploiting the same Multisensor measurements, but in a retrospective setting, achieves a much better accuracy. Data acquired by the Multisensor during a long-term study are retrospectively processed following a two-step procedure. First, the raw data are transformed to a blood glucose (BG) estimate by a multiple linear regression model. Then, an enhancing module is applied in cascade to the regression model to improve the accuracy of the glucose estimation by retrofitting available BG references through a time-varying linear model. MARD between the retrospectively reconstructed BG time-series and reference values is 20%. Here, 94% of values fall in zone A or B of the Clarke Error Grid. The proposed algorithm achieved a level of accuracy that could make this device a potential complementary tool for diabetes management and also for guiding prediabetic or nondiabetic users through life-style changes.
Asunto(s)
Técnicas Biosensibles , Automonitorización de la Glucosa Sanguínea/métodos , Glucemia/aislamiento & purificación , Diabetes Mellitus/sangre , Algoritmos , Diabetes Mellitus/patología , Humanos , Estudios Longitudinales , Estudios RetrospectivosRESUMEN
In the daily management of type 1 diabetes (T1D), determining the correct insulin dose to be injected at meal-time is fundamental to achieve optimal glycemic control. Wearable sensors, such as continuous glucose monitoring (CGM) devices, are instrumental to achieve this purpose. In this paper, we show how CGM data, together with commonly recorded inputs (carbohydrate intake and bolus insulin), can be used to develop an algorithm that allows classifying, at meal-time, the post-prandial glycemic status (i.e., blood glucose concentration being too low, too high, or within target range). Such an outcome can then be used to improve the efficacy of insulin therapy by reducing or increasing the corresponding meal bolus dose. A state-of-the-art T1D simulation environment, including intraday variability and a behavioral model, was used to generate a rich in silico dataset corresponding to 100 subjects over a two-month scenario. Then, an extreme gradient-boosted tree (XGB) algorithm was employed to classify the post-prandial glycemic status. Finally, we demonstrate how the XGB algorithm outcome can be exploited to improve glycemic control in T1D through real-time adjustment of the meal insulin bolus. The proposed XGB algorithm obtained good accuracy at classifying post-prandial glycemic status (AUROC = 0.84 [0.78, 0.87]). Consequently, when used to adjust, in real-time, meal insulin boluses obtained with a bolus calculator, the proposed approach improves glycemic control when compared to the baseline bolus calculator. In particular, percentage time in target [70, 180] mg/dL was improved from 61.98 (± 13.89) to 67.00 (± 11.54; p < 0.01) without increasing hypoglycemia.
Asunto(s)
Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hiperglucemia/tratamiento farmacológico , Hipoglucemiantes/administración & dosificación , Insulina/administración & dosificación , Algoritmos , Glucemia/efectos de los fármacos , Automonitorización de la Glucosa Sanguínea , Simulación por Computador , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/patología , Relación Dosis-Respuesta a Droga , Humanos , Hiperglucemia/sangre , Hiperglucemia/patología , Sistemas de Infusión de Insulina , Periodo Posprandial , Prueba de Estudio ConceptualRESUMEN
The quantitative study of cross-frequency coupling (CFC) is a relevant issue in neuroscience. In local field potentials (LFPs), measured either in the cortex or in the hippocampus, how γ-oscillation amplitude is modulated by changes in θ-rhythms-phase is thought to be important in memory formation. Several methods were proposed to quantify CFC, but reported evidence suggests that experimental parameters affect the results. Therefore, a simulation tool to support the determination of minimal requirements for CFC estimation in order to obtain reliable results is particularly useful. An approach to generate computer-simulated signals having CFC intensity, sweep duration, signal-to-noise ratio (SNR), and multiphasic-coupling tunable by the user has been developed. Its utility has been proved by a study evaluating minimal sweep duration and SNR required for reliable θ-γ CFC estimation from signals simulating LFP measured in the mouse hippocampus. A MATLAB® software was made available to facilitate methodology reproducibility. The analysis of the synthetic LFPs created by the simulator shows how the minimal sweep duration for achieving accurate θ-γ CFC estimates increases as SNR decreases and the number of CFC levels to discriminate increases. In particular, a sufficient reliability in discriminating five different predetermined CFC levels is reached with 35-s sweep with SNR = 20, while SNR = 5 requires at least 140-s sweep.
Asunto(s)
Simulación por Computador , Hipocampo/fisiología , Ritmo Teta , Animales , Memoria , Reproducibilidad de los Resultados , Relación Señal-RuidoRESUMEN
BACKGROUND: Automated insulin delivery (AID) systems, permit improved treatment of type 1 diabetes (T1D). Unfortunately, malfunctioning in the insulin pump or in the infusion set can prevent insulin from being administered, reducing the AID efficacy and posing the patient at risk. Different data-driven methods available in the literature can be used to deal with the problem of automatically detecting complete insulin suspension in real-time. This article investigates both supervised and unsupervised strategies and proposes a fair comparison under either population or personalized settings. METHODS: Several algorithms are compared using data generated through the UVA/Padova T1D simulator, a computer simulator widely used to test control strategies in silico and accepted by the Food and Drugs Administration (FDA) as a substitute to animal pre-clinical trials. Two synthetic data sets, each consisting of 100 virtual subjects monitored for 1 month, were generated. Occasional faults of the insulin pump are simulated as complete occlusions by suspending the therapy administration. Personalized algorithms are investigated with unsupervised approaches only, since personalized labels are hardly available. RESULTS: In the population scenario, the supervised approach outperforms the unsupervised strategy. In particular, logistic regression and random forest achieves a recall of 72% and 82%, with 0.12 and 0.21 false positives (FP) per day, respectively. In the personalized setting scenario, the unsupervised algorithms are tailored on each patient and outperform the population ones, in particular isolation forest achieves a recall 80% and 0.06 FPs per day. CONCLUSIONS: This article suggests that unsupervised personalized approach, by addressing the large variability in glucose response among individuals with T1D, is superior to other one-fits-all approaches in detecting insulin suspensions caused by malfunctioning. Population methodologies can be effectively used while waiting to collect sufficient patient data, when the system is installed on a new patient.