Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Radiologe ; 56(3): 266-74, 2016 Mar.
Artículo en Alemán | MEDLINE | ID: mdl-26885652

RESUMEN

CLINICAL/METHODICAL ISSUE: This article gives an overview of the current importance of so-called subintimal recanalization in the lower extremities. STANDARD RADIOLOGICAL METHODS: The primary technical goal of endovascular interventions in the lower extremities is the endoluminal restoration of blood circulation from the iliac arteries into the feet. METHODICAL INNOVATIONS: If endoluminal recanalization of e.g. high-grade flow-relevant stenoses or chronic total occlusion (CTO) is technically not possible, subintimal recanalization is a promising option and the only remaining minimally invasive alternative. During subintimal recanalization a channel is intentionally generated in the vessel wall (dissection) in order to bypass e. g. a chronic vascular occlusion over as short a distance as possible. PERFORMANCE: The technical success rate for subintimal recanalization of CTO of the lower extremities is 65-100 %. Technical failure occurs in approximately 25 % using the catheter and wire technique and is caused in most cases by difficulties in reaching the true lumen after the subintimal passage (the so-called re-entry). ACHIEVEMENTS: Compared to conventional subintimal recanalization, in recent years so-called re-entry devices have expanded the technical possibilities and depending on the medical experience and training level of the physician, provide an improvement in the technical success rate, a lower complication rate, a reduction of fluoroscopy time and the amount of necessary contrast medium but also result in higher costs. PRACTICAL RECOMMENDATIONS: Subintimal recanalization, whether carried out conventionally with a catheter and wire or using re-entry devices, of high-grade stenoses or CTO in the lower extremities provides a high technical success rate but requires an experienced and trained physician who is capable of operating the elaborate materials and mastering any possible complications.


Asunto(s)
Arteriopatías Oclusivas/cirugía , Procedimientos Endovasculares/métodos , Isquemia/cirugía , Pierna/irrigación sanguínea , Pierna/cirugía , Túnica Íntima/cirugía , Arteriopatías Oclusivas/diagnóstico , Medicina Basada en la Evidencia , Humanos , Isquemia/diagnóstico , Resultado del Tratamiento
2.
Radiologe ; 55(6): 501-9; quiz 510, 2015 Jun.
Artículo en Alemán | MEDLINE | ID: mdl-26063076

RESUMEN

In the context of pre-interventional drug therapy, a premedication is given to patients who are known to have an allergy to contrast media, have renal impairment or hyperthyroidism. An already existing anticoagulation therapy, in anticipation of the planned intervention, must be reviewed and changed or even suspended as required. For peri-interventional drug therapy it is important to consider how strenuous the procedure will be as well as the general condition of the patient. Further discussion with anesthetists may be required for the planning of pain therapy or sedation during the procedure. These factors help to ensure maximum patient comfort as well as the success of the intervention. Post-interventional anticoagulation therapy, usually started peri-interventionally, plays an important role in minimizing the risk of acute thrombosis as well as in maintaining long-term functioning of the implanted material. The form of the anticoagulation therapy is set according to the type of intervention.


Asunto(s)
Anticoagulantes/administración & dosificación , Dolor Postoperatorio/prevención & control , Premedicación/métodos , Radiografía Intervencional/métodos , Trombosis/prevención & control , Humanos , Dolor Postoperatorio/etiología , Radiografía Intervencional/efectos adversos , Trombosis/etiología
3.
Radiologe ; 54(7): 642-53, 2014 Jul.
Artículo en Alemán | MEDLINE | ID: mdl-25047521

RESUMEN

CLINICAL/METHODICAL ISSUE: Evidence-based therapeutic and diagnostic algorithm for hepatocellular carcinoma. STANDARD RADIOLOGICAL METHODS: Ultrasound, computed tomography, magnetic resonance imaging, image-guided percutaneous biopsy, percutaneous thermal ablation and transarterial chemoembolization. METHODICAL INNOVATIONS: Diagnostic and therapy of hepatocellular carcinoma according to the official German interdisciplinary guidelines. PERFORMANCE: The formulation of the German S3 guidelines on diagnosis and therapy of hepatocellular carcinoma was performed under special consideration of quality indicators and standardized quality improvement methods. ACHIEVEMENTS: In 2013 the German S3 guidelines on diagnosis and therapy of hepatocellular carcinoma were published and clinically implemented as part of the nationwide guideline program in oncology of the Deutsche Krebsgesellschaft (German Cancer Society). PRACTICAL RECOMMENDATIONS: The German S3 guidelines on diagnosis and therapy of hepatocellular carcinoma have to be considered as the national gold standard with the goal of optimization of patient care.


Asunto(s)
Carcinoma Hepatocelular/diagnóstico , Carcinoma Hepatocelular/terapia , Hepatectomía/normas , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/terapia , Imagen Multimodal/normas , Guías de Práctica Clínica como Asunto , Alemania , Humanos , Neoplasias Hepáticas/epidemiología , Oncología Médica/normas , Radiología/normas
4.
Radiologe ; 52(1): 44-55, 2012 Jan.
Artículo en Alemán | MEDLINE | ID: mdl-22249701

RESUMEN

Hepatocellular carcinoma (HCC) is the fifth most common cancer worldwide and represents the main cause of death among European patients with liver cirrhosis. Only 30-40% of patients diagnosed with HCC are candidates for curative treatment options (e.g. surgical resection, liver transplantation or ablation). The remaining majority of patients must undergo local regional and palliative therapies. Transvascular ablation of HCC takes advantage of the fact that the hypervascularized HCC receives most of its blood supply from the hepatic artery. In this context transvascular ablation describes different therapy regimens which can be assigned to four groups: cTACE (conventional transarterial chemoembolization), bland embolization (transarterial embolization TAE), DEB-TACE (TACE with drug-eluting beads, DEB) and SIRT (selective internal radiation therapy, radioembolization). Conventional TACE is the most common type of transvascular ablation and represents a combination of intra-arterial chemotherapy and embolization with occlusion of the arterial blood supply. However, there is no standardized regimen with respect to the chemotherapeutic drug, the embolic agent, the usage of lipiodol and the interval between the TACE procedures. Even the exact course of a cTACE procedure (order of chemotherapy or embolization) is not standardized. It remains unclear whether or not intra-arterial chemotherapy is definitely required as bland embolization using very small, tightly calibrated spherical particles (without intra-arterial administration of a chemotherapeutic drug) shows tumor necrosis comparable to cTACE. For DEB-TACE microparticles loaded with a chemotherapeutic drug combine the advantages of cTACE and bland embolization. Thereby, a continuing chemotherapeutic effect within the tumor might cause a further increase in intratumoral cytotoxicity and at the same time a decrease in systemic toxicity.


Asunto(s)
Carcinoma Hepatocelular/terapia , Embolización Terapéutica/métodos , Embolización Terapéutica/tendencias , Hemostáticos/administración & dosificación , Arteria Hepática , Neoplasias Hepáticas/terapia , Humanos , Infusiones Intraarteriales
5.
Br J Surg ; 98(12): 1760-5, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22021030

RESUMEN

BACKGROUND: Liver ischaemia after pancreatic resection is a rare but potentially serious complication. The aim of this study was to determine the impact of postoperative liver ischaemia after pancreatic resection. METHODS: All consecutive patients undergoing pancreatic resection between January 2007 and August 2008 in the Department of Surgery in Heidelberg were identified retrospectively from a prospectively collected database and analysed with a focus on postoperative hepatic perfusion failure. Laboratory data, computed tomography (CT) findings, symptoms, therapy and outcome were recorded. RESULTS: A total of 762 patients underwent pancreatic resection in the study period. Seventeen patients (2·2 per cent) with a postoperative increase in liver enzymes underwent contrast-enhanced CT for suspected liver perfusion failure. The types of perfusion failure were hypoperfusion without occlusion of major hepatic vessels (6 patients) and ischaemia with arterial (5) and/or portal vein (6) involvement. The overall mortality rate was 29 per cent (5 of 17 patients). Therapy included conservative treatment (7), radiological or surgical revascularization and necrosectomy or resection of necrotic liver tissue (10). Outcome varied from full recovery (4 patients) to moderate systemic complications (6) and severe complications (7) including death. Simultaneous involvement of the portal vein and hepatic artery was always fatal. CONCLUSION: Postoperative liver perfusion failure is a rare but potentially severe complication following pancreatic surgery requiring immediate recognition and, if necessary, radiological or surgical intervention.


Asunto(s)
Isquemia/etiología , Hígado/irrigación sanguínea , Páncreas/cirugía , Enfermedades Pancreáticas/cirugía , Complicaciones Posoperatorias/etiología , Alanina Transaminasa/metabolismo , Aspartato Aminotransferasas/metabolismo , Proteína C-Reactiva/metabolismo , Constricción Patológica/etiología , Humanos , Vena Porta , Estudios Prospectivos , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
6.
Eur Surg Res ; 45(1): 26-33, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20720430

RESUMEN

BACKGROUND/AIMS: To determine whether intravenous morphine comedication improves bile duct visualization, diameter and/or volume applying intravenous CT cholangiography in a porcine liver model. METHODS: 12 Landrace pigs underwent intravenous CT cholangiography. Eight minutes after initiation of the contrast material infusion, either morphine sulfate (n = 6 animals) or normal saline (n = 6 animals) was administered. Eighteen consecutive CT scans of the liver were acquired with 2-min intervals starting with initiation of the contrast material infusion. Maximum bile duct visualization scores, diameters and volumes and time to maximum bile duct visualization scores, diameters and volumes were determined. RESULTS: Maximum bile duct visualization scores, diameters and volumes and time to maximum bile duct visualization scores, diameters and volumes were not significantly different when the morphine group was compared to the normal saline group. Maximum bile duct visualization scores ranged between 4.00 ± 0.00 and 2.83 ± 1.47. Maximum bile duct diameters ranged between 6.77 ± 0.40 and 2.10 ± 1.35 mm. Maximum bile duct volume was 16.41 ± 7.33 ml in the morphine group and 16.79 ± 5.65 ml in the normal saline group. CONCLUSION: Intravenous morphine comedication failed to improve bile duct visualization and to increase bile duct diameter and volume applying CT cholangiography.


Asunto(s)
Morfina/administración & dosificación , Analgésicos Opioides/administración & dosificación , Animales , Colecistografía/métodos , Conducto Colédoco/anatomía & histología , Conducto Colédoco/diagnóstico por imagen , Conducto Cístico/diagnóstico por imagen , Infusiones Intravenosas , Radiografía Abdominal , Porcinos , Tomografía Computarizada por Rayos X/métodos
7.
Rofo ; 179(7): 669-75, 2007 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-17592806

RESUMEN

PURPOSE: Investigation of the hardware and image characteristics of a novel micro-CT system and evaluation of its potential to image animals and tissue samples. MATERIALS AND METHODS: The scanner was characterized by phantom studies regarding image homogeneity, CT number stability, soft-tissue contrast, spatial resolution and X-ray dose. The phantoms used were specially designed to evaluate the imaging of mice and rats. Scans of hearts with coronary stents were performed and the tissue morphology and vascularization of tumor-bearing rodents were studied with dynamic contrast-enhanced (DCE) CT. RESULTS: The CT numbers of the acrylic phantoms were reproducible with a 4 HU deviation. The inter-pixel deviation was low but depended on the scan mode. The correlation coefficient between CT number and iodine concentration (0 - 6000 HU) was 0.99. Single wires, lumen and endo-luminal plaques of heart stents were distinguishable. The density-time courses were reliably recorded and made it possible to distinguish the tumor and muscle tissue in DCE micro-CT scans CONCLUSION: The novel micro-CT scanner is suitable for studying tissue densities and contrast agent kinetics.


Asunto(s)
Aumento de la Imagen/instrumentación , Procesamiento de Imagen Asistido por Computador/instrumentación , Imagenología Tridimensional/instrumentación , Miniaturización/instrumentación , Tomógrafos Computarizados por Rayos X , Animales , Materiales Biocompatibles Revestidos , Medios de Contraste/farmacocinética , Angiografía Coronaria , Reestenosis Coronaria/diagnóstico por imagen , Diseño de Equipo , Glioma/diagnóstico por imagen , Humanos , Yohexol/análogos & derivados , Yohexol/farmacocinética , Yopamidol/análogos & derivados , Yopamidol/farmacocinética , Ratones , Ratones Desnudos , Músculo Esquelético/diagnóstico por imagen , Trasplante de Neoplasias , Paclitaxel , Fantasmas de Imagen , Dosis de Radiación , Ratas , Sensibilidad y Especificidad , Neoplasias de los Tejidos Blandos/diagnóstico por imagen , Stents , Porcinos
8.
Rofo ; 188(4): 353-8, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26716403

RESUMEN

UNLABELLED: On February 26th, 2013 the patient law became effective in Germany. Goal of the lawmakers was a most authoritative case law for liability of malpractice and to improve enforcement of the rights of the patients. The following article contains several examples detailing legal situation. By no means should these discourage those persons who treat patients. Rather should they be sensitized to to various aspects of this increasingly important field of law. To identify relevant sources according to judicial standard research was conducted including first- and second selection. Goal was the identification of jurisdiction, literature and other various analyses that all deal with liability of malpractice and patient law within the field of Interventional Radiology--with particular focus on transarterial chemoembolization of the liver and related procedures. In summary, 89 different sources were included and analyzed. The individual who treats a patient is liable for an error in treatment if it causes injury to life, the body or the patient's health. Independent of the error in treatment the individual providing medical care is liable for mistakes made in the context of obtaining informed consent. Prerequisite is the presence of an error made when obtaining informed consent and its causality for the patient's consent for the treatment. Without an effective consent the treatment is considered illegal whether it was free of treatment error or not. The new patient law does not cause material change of the German liablity of malpractice law. KEY POINTS: •On February 26th, 2013 the new patient law came into effect. Materially, there was no fundamental remodeling of the German liability for medical malpractice. •Regarding a physician's liability for medical malpractice two different elements of an offence come into consideration: for one the liability for malpractice and, in turn, liability for errors made during medical consultation in the process of obtaining informed consent. •Forensic practice shows that patients frequently enforce both offences concurrently.


Asunto(s)
Consentimiento Informado/legislación & jurisprudencia , Responsabilidad Legal , Errores Médicos/legislación & jurisprudencia , Médicos/legislación & jurisprudencia , Radiografía Intervencional/normas , Radiología Intervencionista/legislación & jurisprudencia , Alemania , Regulación Gubernamental
9.
Aliment Pharmacol Ther ; 43(9): 955-65, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26919285

RESUMEN

BACKGROUND: Transjugular intrahepatic portosystemic shunt (TIPSS) cause haemodynamic changes in patients with cirrhosis, yet little is known about long-term cardiopulmonary outcomes. AIM: To evaluate the long-term cardiopulmonary outcome after TIPSS. METHODS: We evaluated cardiopulmonary parameters including echocardiography during long-term follow-up after TIPSS. Results at 1-5 years after TIPSS were compared to those of cirrhotic controls. Pulmonary hypertension (PH) diagnoses rates were included. Endothelin 1, thromboxane B2 and serotonin were measured. RESULTS: We found significant differences 1-5 years after TIPSS compared to pre-implantation values: median left atrial diameter (LAD) increased from 37 mm [interquartile range (IQR): 33-43] to 40 mm (IQR: 37-47, P = 0.001), left ventricular end-diastolic diameter (LV-EDD) increased from 45 mm (range: 41-49) to 48 mm (IQR: 45-52, P < 0.001), pulmonary artery systolic pressure (PASP) increased from 25 mmHg (IQR: 22-33) to 30 mmHg (IQR: 25-36, P = 0.038). Comparing results 1-5 years post-implantation to the comparison cohort revealed significantly higher (P < 0.05) LAD, LV-EDD and PASP values in TIPSS patients. PH prevalence was higher in the shunt group (4.43%) compared to controls (0.91%, P = 0.150). Thromboxane B2 levels correlated with PASP in the TIPSS cohort (P = 0.033). There was no transhepatic gradient observed for the vasoactive substances analysed. CONCLUSIONS: TIPSS placement is accompanied by long-term cardiovascular changes, including cardiac volume overload, and is associated with an increased rate of pulmonary hypertension. The need for regular cardiac follow-up after TIPSS requires further evaluation.


Asunto(s)
Volumen Cardíaco/fisiología , Hipertensión Pulmonar/fisiopatología , Cirrosis Hepática/terapia , Derivación Portosistémica Intrahepática Transyugular/efectos adversos , Adulto , Endotelina-1/metabolismo , Femenino , Estudios de Seguimiento , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Derivación Portosistémica Intrahepática Transyugular/métodos , Serotonina/metabolismo , Tromboxano B2/metabolismo
10.
Urologe A ; 54(2): 219-30, 2015 Feb.
Artículo en Alemán | MEDLINE | ID: mdl-25690575

RESUMEN

BACKGROUND: Stage I renal cell carcinoma is a malignancy with a relatively good prognosis. The incidence of all renal cell carcinomas is approximately 9/100,000 persons. There are nearly 15,000 newly diagnosed patients every year (men twice as often as women). TREND: In the last decade, a trend away from radical open resection towards nephron-sparing approaches has been observed. Currently, partial nephrectomy is the surgical gold standard for the treatment of small renal tumors. However, excellent clinical results are obtained using percutaneous radiofrequency ablation (RFA): low complication rates and preservation of the renal function. RESULTS: Primary and secondary technical success rates are 69-100% and 90-100%, respectively. In large series, major complication rates of RFA of 0-14% are reported. A relevant deterioration of renal function after RFA is very rare. The 5-year local recurrence-free survival rates, metastasis-free survival rates, cancer-specific survival rates, and overall survival rates are 88-93, 95-100, 98-100, and 58.3-85%, respectively. In this context, the lack of appropriate long-term data is often cited as a limitation. CONCLUSION: Different meta-analyses come to the conclusion that in case of adequate tumor and patient selection RFA shows oncologic results comparable with surgical resection. Accepted indications for RFA are T1 renal tumors in patients with advanced age, significant comorbidities, reduced renal function, single kidney, and/or no wish for operation. Predictors for the success include tumor size and location as well as operator experience. To define the real efficacy of RFA in the treatment of renal tumors, randomized controlled clinical long-term studies are indicated.


Asunto(s)
Carcinoma de Células Renales/cirugía , Ablación por Catéter/métodos , Neoplasias Renales/cirugía , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Tratamientos Conservadores del Órgano/métodos , Carcinoma de Células Renales/diagnóstico , Medicina Basada en la Evidencia , Humanos , Neoplasias Renales/diagnóstico , Resultado del Tratamiento
11.
Cardiovasc Intervent Radiol ; 38(1): 191-200, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24870700

RESUMEN

PURPOSE: To evaluate the effect of previous transarterial iodized oil tissue marking (ITM) on technical parameters, three-dimensional (3D) computed tomographic (CT) rendering of the electroporation zone, and histopathology after CT-guided irreversible electroporation (IRE) in an acute porcine liver model as a potential strategy to improve IRE performance. METHODS: After Ethics Committee approval was obtained, in five landrace pigs, two IREs of the right and left liver (RL and LL) were performed under CT guidance with identical electroporation parameters. Before IRE, transarterial marking of the LL was performed with iodized oil. Nonenhanced and contrast-enhanced CT examinations followed. One hour after IRE, animals were killed and livers collected. Mean resulting voltage and amperage during IRE were assessed. For 3D CT rendering of the electroporation zone, parameters for size and shape were analyzed. Quantitative data were compared by the Mann-Whitney test. Histopathological differences were assessed. RESULTS: Mean resulting voltage and amperage were 2,545.3 ± 66.0 V and 26.1 ± 1.8 A for RL, and 2,537.3 ± 69.0 V and 27.7 ± 1.8 A for LL without significant differences. Short axis, volume, and sphericity index were 16.5 ± 4.4 mm, 8.6 ± 3.2 cm(3), and 1.7 ± 0.3 for RL, and 18.2 ± 3.4 mm, 9.8 ± 3.8 cm(3), and 1.7 ± 0.3 for LL without significant differences. For RL and LL, the electroporation zone consisted of severely widened hepatic sinusoids containing erythrocytes and showed homogeneous apoptosis. For LL, iodized oil could be detected in the center and at the rim of the electroporation zone. CONCLUSION: There is no adverse effect of previous ITM on technical parameters, 3D CT rendering of the electroporation zone, and histopathology after CT-guided IRE of the liver.


Asunto(s)
Electroporación/métodos , Imagenología Tridimensional/métodos , Aceite Yodado/administración & dosificación , Hígado/diagnóstico por imagen , Radiografía Intervencional/métodos , Tomografía Computarizada por Rayos X/métodos , Animales , Modelos Animales , Porcinos
12.
Cardiovasc Intervent Radiol ; 38(2): 442-52, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25167958

RESUMEN

PURPOSE: This study was designed to compare technical parameters during ablation as well as CT 3D rendering and histopathology of the ablation zone between sphere-enhanced microwave ablation (sMWA) and bland microwave ablation (bMWA). METHODS: In six sheep-livers, 18 microwave ablations were performed with identical system presets (power output: 80 W, ablation time: 120 s). In three sheep, transarterial embolisation (TAE) was performed immediately before microwave ablation using spheres (diameter: 40 ± 10 µm) (sMWA). In the other three sheep, microwave ablation was performed without spheres embolisation (bMWA). Contrast-enhanced CT, sacrifice, and liver harvest followed immediately after microwave ablation. Study goals included technical parameters during ablation (resulting power output, ablation time), geometry of the ablation zone applying specific CT 3D rendering with a software prototype (short axis of the ablation zone, volume of the largest aligned ablation sphere within the ablation zone), and histopathology (hematoxylin-eosin, Masson Goldner and TUNEL). RESULTS: Resulting power output/ablation times were 78.7 ± 1.0 W/120 ± 0.0 s for bMWA and 78.4 ± 1.0 W/120 ± 0.0 s for sMWA (n.s., respectively). Short axis/volume were 23.7 ± 3.7 mm/7.0 ± 2.4 cm(3) for bMWA and 29.1 ± 3.4 mm/11.5 ± 3.9 cm(3) for sMWA (P < 0.01, respectively). Histopathology confirmed the signs of coagulation necrosis as well as early and irreversible cell death for bMWA and sMWA. For sMWA, spheres were detected within, at the rim, and outside of the ablation zone without conspicuous features. CONCLUSIONS: Specific CT 3D rendering identifies a larger ablation zone for sMWA compared with bMWA. The histopathological signs and the detectable amount of cell death are comparable for both groups. When comparing sMWA with bMWA, TAE has no effect on the technical parameters during ablation.


Asunto(s)
Ablación por Catéter/métodos , Imagenología Tridimensional/métodos , Hígado/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Animales , Medios de Contraste , Aumento de la Imagen , Hígado/ultraestructura , Microondas , Modelos Animales , Ovinos
13.
Cardiovasc Intervent Radiol ; 36(3): 731-7, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22926302

RESUMEN

PURPOSE: This study was designed to evaluate the clinical efficacy of CT-guided bipolar and multipolar radiofrequency ablation (RF ablation) of renal cell carcinoma (RCC) and to analyze specific technical aspects between both technologies. METHODS: We included 22 consecutive patients (3 women; age 74.2 ± 8.6 years) after 28 CT-guided bipolar or multipolar RF ablations of 28 RCCs (diameter 2.5 ± 0.8 cm). Procedures were performed with a commercially available RF system (Celon AG Olympus, Berlin, Germany). Technical aspects of RF ablation procedures (ablation mode [bipolar or multipolar], number of applicators and ablation cycles, overall ablation time and deployed energy, and technical success rate) were analyzed. Clinical results (local recurrence-free survival and local tumor control rate, renal function [glomerular filtration rate (GFR)]) and complication rates were evaluated. RESULTS: Bipolar RF ablation was performed in 12 procedures and multipolar RF ablation in 16 procedures (2 applicators in 14 procedures and 3 applicators in 2 procedures). One ablation cycle was performed in 15 procedures and two ablation cycles in 13 procedures. Overall ablation time and deployed energy were 35.0 ± 13.6 min and 43.7 ± 17.9 kJ. Technical success rate was 100 %. Major and minor complication rates were 4 and 14 %. At an imaging follow-up of 15.2 ± 8.8 months, local recurrence-free survival was 14.4 ± 8.8 months and local tumor control rate was 93 %. GFR did not deteriorate after RF ablation (50.8 ± 16.6 ml/min/1.73 m(2) before RF ablation vs. 47.2 ± 11.9 ml/min/1.73 m(2) after RF ablation; not significant). CONCLUSIONS: CT-guided bipolar and multipolar RF ablation of RCC has a high rate of clinical success and low complication rates. At short-term follow-up, clinical efficacy is high without deterioration of the renal function.


Asunto(s)
Carcinoma de Células Renales/cirugía , Ablación por Catéter/métodos , Neoplasias Renales/cirugía , Radiografía Intervencional/métodos , Tomografía Computarizada por Rayos X , Anciano , Anciano de 80 o más Años , Carcinoma de Células Renales/diagnóstico por imagen , Carcinoma de Células Renales/patología , Femenino , Humanos , Pruebas de Función Renal , Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/patología , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Estudios Retrospectivos , Resultado del Tratamiento
14.
Cardiovasc Intervent Radiol ; 35(3): 653-60, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21562934

RESUMEN

PURPOSE: This study was designed to analyze the effect of two different ablation modes ("temperature control" and "power control") of a microwave system on procedural outcome in porcine kidneys in vivo. METHODS: A commercially available microwave system (Avecure Microwave Generator; MedWaves, San Diego, CA) was used. The system offers the possibility to ablate with two different ablation modes: temperature control and power control. Thirty-two microwave ablations were performed in 16 kidneys of 8 pigs. In each animal, one kidney was ablated twice by applying temperature control (ablation duration set point at 60 s, ablation temperature set point at 96°C, automatic power set point; group I). The other kidney was ablated twice by applying power control (ablation duration set point at 60 s, ablation temperature set point at 96°C, ablation power set point at 24 W; group II). Procedural outcome was analyzed: (1) technical success (e.g., system failures, duration of the ablation cycle), and (2) ablation geometry (e.g., long axis diameter, short axis diameter, and circularity). RESULTS: System failures occurred in 0% in group I and 13% in group II. Duration of the ablation cycle was 60±0 s in group I and 102±21 s in group II. Long axis diameter was 20.3±4.6 mm in group I and 19.8±3.5 mm in group II (not significant (NS)). Short axis diameter was 10.3±2 mm in group I and 10.5±2.4 mm in group II (NS). Circularity was 0.5±0.1 in group I and 0.5±0.1 in group II (NS). CONCLUSIONS: Microwave ablations performed with temperature control showed fewer system failures and were finished faster. Both ablation modes demonstrated no significant differences with respect to ablation geometry.


Asunto(s)
Ablación por Catéter/métodos , Riñón/cirugía , Microondas/uso terapéutico , Nefrectomía/métodos , Animales , Ablación por Catéter/instrumentación , Modelos Animales , Nefrectomía/instrumentación , Porcinos , Temperatura
15.
Eur J Radiol ; 81(9): 2007-13, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21696902

RESUMEN

PURPOSE: To prospectively evaluate whether intravenous morphine co-medication improves bile duct visualization of dual-energy CT-cholangiography. MATERIALS AND METHODS: Forty potential donors for living-related liver transplantation underwent CT-cholangiography with infusion of a hepatobiliary contrast agent over 40 min. Twenty minutes after the beginning of the contrast agent infusion, either normal saline (n=20 patients; control group [CG]) or morphine sulfate (n=20 patients; morphine group [MG]) was injected. Forty-five minutes after initiation of the contrast agent, a dual-energy CT acquisition of the liver was performed. Applying dual-energy post-processing, pure iodine images were generated. Primary study goals were determination of bile duct diameters and visualization scores (on a scale of 0 to 3: 0--not visualized; 3--excellent visualization). RESULTS: Bile duct visualization scores for second-order and third-order branch ducts were significantly higher in the MG compared to the CG (2.9±0.1 versus 2.6±0.2 [P<0.001] and 2.7±0.3 versus 2.1±0.6 [P<0.01], respectively). Bile duct diameters for the common duct and main ducts were significantly higher in the MG compared to the CG (5.9±1.3 mm versus 4.9±1.3 mm [P<0.05] and 3.7±1.3 mm versus 2.6±0.5 mm [P<0.01], respectively). CONCLUSION: Intravenous morphine co-medication significantly improved biliary visualization on dual-energy CT-cholangiography in potential donors for living-related liver transplantation.


Asunto(s)
Absorciometría de Fotón/métodos , Colangiografía/métodos , Selección de Donante/métodos , Trasplante de Hígado/diagnóstico por imagen , Morfina/administración & dosificación , Tomografía Computarizada por Rayos X/métodos , Analgésicos Opioides/administración & dosificación , Conductos Biliares , Medios de Contraste/administración & dosificación , Femenino , Humanos , Aumento de la Imagen/métodos , Inyecciones Intravenosas , Donadores Vivos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
16.
Eur J Radiol ; 81(6): 1165-72, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21458182

RESUMEN

PURPOSE: To describe angiographic, macroscopic and microscopic features of super-micro-bland particle embolization in combination with RF-ablation in kidneys. Thereby, a special focus was given on the impact of the sequence of the different procedural steps. MATERIALS AND METHODS: In ten pigs, super-micro-bland particle embolization combined with RF-ablation was carried out. Super-micro-bland embolization was performed with spherical particles of very small size and tight calibration (40 ± 10 µm). In the left kidneys, RF-ablations were performed before embolization (I). In the right kidneys, RF-ablations were performed after embolization (II). The animals were killed three hours after the procedures. Angiographic (e.g. vessel architecture), macroscopic (e.g. long and short axes of the RF-ablations) and microscopic (e.g. particle distribution) study goals were defined. RESULTS: Angiography detected almost no vessels in the center of the RF-ablations in I. In II, angiography could not define the RF-ablations. Macroscopy detected significantly larger long and short axes of the RF-ablations in II compared to I (52.2 ± 3.2 mm vs. 45.3 ± 6.9 mm [P<0.05] and 25.1 ± 3.5mm vs. 20.0 ± 1.9 mm [P<0.01], respectively). Microscopy detected irregular particle distribution at the rim of the RF-ablations in I. In II, microscopy detected homogeneous particle distribution at the rim of the RF-ablations. Microscopy detected no particles in the center of the RF-ablations in I and II. CONCLUSION: The sequence of the different procedural steps of super-micro-bland particle embolization combined with RF-ablation impacts angiographic, macroscopic and microscopic features in kidneys in the acute setting.


Asunto(s)
Ablación por Catéter/métodos , Embolización Terapéutica/métodos , Riñón/irrigación sanguínea , Riñón/patología , Angiografía , Animales , Riñón/cirugía , Tamaño de la Partícula , Radiografía Intervencional , Reproducibilidad de los Resultados , Estadísticas no Paramétricas , Porcinos
17.
Cardiovasc Intervent Radiol ; 34(5): 1085-9, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21553163

RESUMEN

A 37-year-old man with known intravenous drug abuse presented in the surgical ambulatory care unit with acute leg ischemia after accidental intra-arterial injection of dissolved flunitrazepam tablets into the right femoral artery. A combination of anticoagulation, vasodilatation, and local selective and superselective thrombolysis with urokinase was performed to salvage the leg. As a result of the severe ischemia-induced pain, the patient had to be monitored over the complete therapy period on the intensive care unit with permanent administration of intravenous fluid and analgetics. We describe the presenting symptoms and the interventional technique, and we discuss the recent literature regarding the management of accidental intra-arterial injection of dissolved flunitrazepam tablets.


Asunto(s)
Ansiolíticos/administración & dosificación , Ansiolíticos/efectos adversos , Flunitrazepam/efectos adversos , Isquemia/inducido químicamente , Pierna/irrigación sanguínea , Trastornos Relacionados con Sustancias , Terapia Trombolítica , Enfermedad Aguda , Adulto , Alprostadil/uso terapéutico , Anestésicos Locales , Fibrinolíticos/uso terapéutico , Flunitrazepam/administración & dosificación , Humanos , Inyecciones Intraarteriales , Isquemia/diagnóstico por imagen , Isquemia/tratamiento farmacológico , Lidocaína/uso terapéutico , Masculino , Radiografía , Activador de Plasminógeno de Tipo Uroquinasa/uso terapéutico , Vasoconstricción/efectos de los fármacos , Vasodilatadores/uso terapéutico
18.
Cardiovasc Intervent Radiol ; 34(1): 139-48, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20976452

RESUMEN

OBJECTIVE: To investigate the safety and efficacy of a Polyzene-F nanocoat on new low-profile self-expandable nitinol stents in minipig renal arteries. MATERIALS AND METHODS: Ten bare nitinol stents (BNS) and 10 stents coated with a 50 nm-thin Polyzene-F coating were randomly implanted into renal arteries of 10 minipigs (4- and 12-week follow-up, 5 animals/group). Thrombogenicity, on-stent surface endothelialization, vessel wall injury, late in-stent stenosis, and peristrut vessel wall inflammation were determined by quantitative angiography and postmortem histomorphometry. RESULTS: In 6 of 10 BNS, >50% stenosis was found, but no stenosis was found in stents with a nanothin Polyzene-F coating. Histomorphometry showed a statistically significant (p < 0.05) different average maximum luminal loss of 55.16% ± 8.43% at 12 weeks in BNS versus 39.77% ± 7.41% in stents with a nanothin Polyzene-F coating. Stents with a nanothin Polyzene-F coating had a significantly (p < 0.05) lower inflammation score after 12 weeks, 1.31 ± 1.17 versus 2.17 ± 0.85 in BNS. The results for vessel wall injury (0.6 ± 0.58 for Polyzene-F-coated stents; 0.72 ± 0.98 for BNS) and re-endothelialization, (1.16 ± 0.43 and 1.23 ± 0.54, respectively) were not statistically significant at 12-week follow-up. No thrombus deposition was observed on the stents at either follow-up time point. CONCLUSION: Nitinol stents with a nanothin Polyzene-F coating successfully decreased in-stent stenosis and vessel wall inflammation compared with BNS. Endothelialization and vessel wall injury were found to be equal. These studies warrant long-term pig studies (≥120 days) because 12 weeks may not be sufficient time for complete healing; thereafter, human studies may be warranted.


Asunto(s)
Oclusión de Injerto Vascular/prevención & control , Arteria Renal , Stents , Aleaciones , Angiografía , Animales , Materiales Biocompatibles Revestidos , Nanotecnología , Compuestos Organofosforados , Polímeros , Radiografía Intervencional , Distribución Aleatoria , Estadísticas no Paramétricas , Porcinos , Porcinos Enanos
19.
Cardiovasc Intervent Radiol ; 34(4): 808-15, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21301846

RESUMEN

PURPOSE: This study was designed to investigate the benefit of percutaneous interventional management of patients with postoperative bile leak on clinical outcome. Primary study endpoints were closure of the bile leak and duration of percutaneous transhepatic biliary drainage (PTBD) treatment. Secondary study endpoints were necessity of additional CT-guided drainage catheter placement, course of serum CRP level as parameter for inflammation, and patients' survival. METHODS: Between January 2004 and April 2008, all patients who underwent PTBD placement after upper gastrointestinal surgery were analyzed regarding site of bile leak and previous attempt of operative bile leak repair, interval between initial surgery and PTBD placement, procedural interventional management, course of inflammation parameters, duration of PTBD therapy, PTBD-related complications, and patients' survival. RESULTS: Thirty patients underwent PTBD placement for treatment of postoperative bile leaks. In 12 patients (40%), PTBD was performed secondary to a surgical attempt of bile leak repair. Additional percutaneous drainage of bilomas was performed in 14 patients (47%). CRP serum level decreased from 138.1 ± 73.4 mg/l before PTBD placement to 43.5 ± 33.4 mg/l 30 days after PTBD placement. The mean duration of PTBD treatment was 55.2 ± 32.5 days in the surviving patients. In one patient, a delayed stenosis of the bile duct required balloon dilation. Two PTBD-related complications (portobiliary fistula, hepatic artery aneurysm) occurred, which were successfully treated by embolization. Overall survival was 73% (22 patients). CONCLUSIONS: PTBD treatment is an effective therapy. PTBD treatment and additional CT-guided drainage of bilomas helped to reduce intraabdominal inflammation, as shown by reduction of inflammation parameters.


Asunto(s)
Fuga Anastomótica/terapia , Fístula Biliar/terapia , Cateterismo/métodos , Drenaje/métodos , Complicaciones Posoperatorias/terapia , Tomografía Computarizada Espiral , Tracto Gastrointestinal Superior/cirugía , Adulto , Anciano , Fuga Anastomótica/mortalidad , Fístula Biliar/mortalidad , Causas de Muerte , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/mortalidad , Estudios Retrospectivos , Tasa de Supervivencia
20.
Eur J Radiol ; 80(3): 686-91, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-20971592

RESUMEN

AIM: To report our experience of combined CT- and fluoroscopy-guided nephrostomy in patients with non-obstructive uropathy due to urine leaks in cases of failed ultrasound-guided procedures. PATIENTS AND METHODS: Eighteen patients (23 kidneys) with non-obstructive uropathy due to urine leaks underwent combined CT- and fluoroscopy-guided nephrostomy. All procedures were indicated as second-line interventions after failed ultrasound-guided nephrostomy. Thirteen males and five females with an age of 62.3±8.7 (40-84) years were treated. Urine leaks developed in majority after open surgery, e.g. postoperative insufficiency of ureteroneocystostomy (5 kidneys). The main reasons for failed ultrasound-guided nephrostomy included anatomic obstacles in the puncture tract (7 kidneys), and inability to identify pelvic structures (7 kidneys). CT-guided guidewire placement into the collecting system was followed by fluoroscopy-guided nephrostomy tube positioning. Procedural success rate, major and minor complication rates, CT-views and needle passes, duration of the procedure and radiation dose were analyzed. RESULTS: Procedural success was 91%. Major and minor complication rates were 9% (one septic shock and one perirenal abscess) and 9% (one perirenal haematoma and one urinoma), respectively. 30-day mortality rate was 6%. Number of CT-views and needle passes were 9.3±6.1 and 3.6±2.6, respectively. Duration of the complete procedure was 87±32 min. Dose-length product and dose-area product were 1.8±1.4 Gy cm and 3.9±4.3 Gy cm2, respectively. CONCLUSIONS: Combined CT- and fluoroscopy-guided nephrostomy in patients with non-obstructive uropathy due to urine leaks in cases of failed ultrasound-guided procedures was feasible with high technical success and a tolerable complication rate.


Asunto(s)
Fluoroscopía/métodos , Nefrostomía Percutánea/métodos , Cirugía Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Obstrucción Ureteral/diagnóstico por imagen , Obstrucción Ureteral/cirugía , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reoperación/métodos , Resultado del Tratamiento , Ultrasonografía/métodos
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda