Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Publication year range
1.
J Clin Med ; 12(17)2023 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-37685536

RESUMEN

The importance of assessing the collateral status (CS) in patients with ischaemic stroke (IS) has repeatedly been emphasised in clinical guidelines. Various publications offer qualitative or semiquantitative scales with gradations corresponding to the different extents of the collaterals, visualised mostly on the basis of CTA images. However, information on their inter-rater reliability is limited. Therefore, the aim of this study is to investigate the inter-rater reliability of the scales for collateral assessment. CTA images of 158 patients in the acute period of IS were used in the study. The assessment of CS was performed by two experts using three methodologies: the modified Tan scale, the Miteff scale, and the Rosenthal scale. Cohen's kappa, weighted kappa and Krippendorff's alpha were used as reliability measures. For the modified Tan scale and the Miteff and Rosenthal scales, the weighted kappa values were 0.72, 0.49 and 0.59, respectively. Although the best measure of consistency was found for the modified Tan scale, no statistically significant differences were revealed among the scales. The impact of the CS on the degree of neurological deficit at discharge was shown for the modified Tan and Rosenthal scales. In conclusion, the analysis showed a moderate inter-rater reliability of the three scales, but was not able to distinguish the best one among them.

2.
J Clin Neurophysiol ; 37(1): 50-55, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31335563

RESUMEN

PURPOSE: Navigated transcranial magnetic stimulation (nTMS) provides noninvasive visualization of eloquent brain areas. The nTMS is usually applied in presurgical planning to minimize the risk of surgery-related neurological deterioration. The aim of this study was to evaluate the usefulness of nTMS data for GammaKnife treatment planning for patients suffering from brain metastases. METHODS: Motor cortex mapping with nTMS was performed in eight patients with brain metastases within or adjacent to the precentral gyrus. The nTMS data set was imported into the planning software and fused with anatomical MRI. Then contouring of the target and critical structures was performed. Treatment plans with and without visualization of the functional structures by nTMS were analyzed and compared by neurosurgeon and medical physicist. RESULTS: The primary motor cortex was successfully delineated even in all cases despite significant peritumoral edema. Beam shaping and combined isocenters were used for conformal dose distribution and steeper dose fall-off near the identified eloquent zone. Compared with plans without nTMS data, treatment plans with integration of cortical nTMS mapping data showed a 2% to 78% (mean, 35.2% ± 22.7%) lower 12-Gy volume within the motor cortex without reduction of the dose applied to the tumor. CONCLUSIONS: The presented approach allows the easy and reliable integration of neurophysiological mapping data into GammaKnife treatment plans by the standard GammaPlan software. Diminishing the dose to critical structures might help to minimize side effects and therefore improve quality of life for brain metastasis patients.


Asunto(s)
Mapeo Encefálico/métodos , Neoplasias Encefálicas/cirugía , Corteza Motora/diagnóstico por imagen , Neuronavegación/métodos , Radiocirugia/métodos , Adulto , Anciano , Neoplasias Encefálicas/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Calidad de Vida , Estimulación Magnética Transcraneal/métodos
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda