Mar Pollut Bull ; 135: 150-158, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30301024

RESUMEN

This study defines performance characteristics of the temperature-modified ISO 9308-1 method for E. coli enumeration in bathing water. After a 4-hour resuscitation period at 36 ±â€¯2 °C, the incubation temperature was changed to 44 ±â€¯0.5 °C. Elevated incubation temperature significantly suppressed the growth of thermo-intolerant bacteria, and enhanced the selectivity of Chromogenic Coliform Agar (CCA) up to 49.5% for inland and up to 66.0% for coastal water. Consequently, most of the selectivity-related performance characteristics are improved. Relative recovery was determined by comparing an alternative method against the reference, ISO 9308-1:2014 method, following the criteria set out in ISO 17994:2014. Temperature modification did not significantly alter the results and the methods were evaluated as "not different" for both, coastal and inland waters. Chromogenic Coliform Agar was assessed as a suitable medium for reliable E. coli enumeration in bathing water when incubated for 17-19 h at 44 ±â€¯0.5 °C after the 4-5 h resuscitation period at 36 ±â€¯2 °C.


Asunto(s)
Técnicas Bacteriológicas/métodos , Escherichia coli , Microbiología del Agua , Agar , Playas , Medios de Cultivo , Escherichia coli/crecimiento & desarrollo , Escherichia coli/aislamiento & purificación , Agua de Mar/microbiología , Temperatura