Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 84
Filtrar
1.
Arch Orthop Trauma Surg ; 144(5): 2131-2140, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38520547

RESUMEN

INTRODUCTION: Treatment of both simple and complex patella fractures is a challenging clinical problem. Although tension band wiring has been the standard of care, it can be associated with high complication rates. The aim of this study was to investigate the biomechanical performance of recently developed lateral rim variable angle locking plates versus tension band wiring used for fixation of simple and complex patella fractures. MATERIALS AND METHODS: Sixteen pairs of human anatomical knees were used to simulate either two-part transverse simple AO/OTA 34-C1 or five-part complex AO/OTA 34-C3 patella fractures by means of osteotomies, with each fracture model created in eight pairs. The complex fracture pattern was characterized by a medial and a lateral proximal fragment, together with an inferomedial, an inferolateral, and an inferior (central distal) fragment mimicking comminution around the distal patellar pole. The specimens with simple fractures were pairwise assigned for fixation with either tension band wiring through two parallel cannulated screws or a lateral rim variable angle locking plate. The knees with complex fractures were pairwise treated with either tension band wiring through two parallel cannulated screws plus circumferential cerclage wiring or a lateral rim variable angle locking plate. Each specimen was tested over 5000 cycles by pulling on the quadriceps tendon, simulating active knee extension and passive knee flexion within the range of 90° flexion to full extension. Interfragmentary movements were captured via motion tracking. RESULTS: For both fracture types, the articular displacements measured between the proximal and distal fragments at the central patella aspect between 1000 and 5000 cycles, together with the relative rotations of these fragments around the mediolateral axis were all significantly smaller following the lateral rim variable angle locked plating compared with tension band wiring, p ≤ 0.01. CONCLUSIONS: From a biomechanical perspective, lateral rim variable angle locked plating of both simple and complex patella fractures provides superior construct stability versus tension band wiring under dynamic loading.


Asunto(s)
Placas Óseas , Hilos Ortopédicos , Fijación Interna de Fracturas , Fracturas Óseas , Rótula , Humanos , Rótula/lesiones , Rótula/cirugía , Fenómenos Biomecánicos , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Fracturas Óseas/cirugía , Cadáver , Anciano , Masculino , Femenino , Fractura de Rótula
2.
BMC Musculoskelet Disord ; 24(1): 279, 2023 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-37041618

RESUMEN

BACKGROUND: The aim of this study was to investigate the biomechanical performance of novel anterior variable-angle locking plates versus tension band wiring used for fixation of simple and complex patella fractures. METHODS: Sixteen pairs of human cadaveric knees were used to simulate two-part simple transverse AO/OTA 34-C1 and five-part complex AO/OTA 34-C3 patella fractures. The complex fracture pattern was characterized with a medial and a lateral proximal fragment, together with an inferomedial, an inferolateral and an inferior fragment mimicking comminution around the distal patella pole. Eight pairs with simple fractures were split for fixation via either tension band wiring (TBW) through two parallel cannulated screws or anterior variable-angle locked plating, whereas other eight pairs with complex fractures were split for either TBW through two parallel cannulated screws plus circumferential cerclage wiring, or anterior variable-angle locked plating using a cortical caudo-cranial polar screw. Each specimen was tested over 5000 cycles with a range of motion from 90° flexion to full extension by pulling on the quadriceps tendon. Interfragmentary movements were captured by motion tracking. RESULTS: For both fracture types, the longitudinal and shear articular displacements, measured between the proximal and distal fragments at the central patella aspect between 1000 and 5000 cycles, together with the relative rotations of these fragments around the mediolateral axis were all significantly smaller following anterior variable-angle locked plating versus TBW, p ≤ 0.01. CONCLUSIONS: From a biomechanical perspective, anterior locked plating of both simple and complex patella fractures resulted in less interfragmentary displacement under extended cyclic loading.


Asunto(s)
Fracturas Óseas , Traumatismos de la Rodilla , Fractura de Rótula , Humanos , Fenómenos Biomecánicos , Fracturas Óseas/cirugía , Fijación Interna de Fracturas/métodos , Tornillos Óseos , Traumatismos de la Rodilla/cirugía
3.
J Shoulder Elbow Surg ; 32(5): 1079-1087, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36737031

RESUMEN

BACKGROUND: Coronoid fractures frequently occur as part of complex elbow injuries and account for 2%-15% of the cases with dislocations. Comminuted fractures and nonunions necessitate surgical treatment. Considering the latest technological advancements, the aim of this study was to investigate the fixation strength of coronoid replacement using an individualized 3D printed prosthesis with curved cemented intramedullary (IM) stem vs. both radial head grafted reconstruction and coronoid fixation. METHODS: Twenty-four human cadaveric paired forearms were stripped of soft tissue and their computed tomography scanned ulnas were randomized to 4 groups for coronoid replacement (prosthesis group), radial head grafted reconstruction (radial head group), fixation (fixation group), or no treatment (intact group). The ulnas in all groups, except the intact one, were osteotomized at 40% of the coronoid height and the coronoid process was either replaced with a 3D printed stainless-steel prosthesis with curved cemented IM stem individually designed based on the contralateral scan (prosthesis group), reconstructed with an ipsilateral radial head autograft fixed with 2 anteroposterior screws (radial head group), or fixed in situ with 2 anteroposterior screws (fixation group). All specimens were biomechanically tested under ramped quasistatic axial loading. RESULTS: Bone mineral density was not significantly different among the groups (P = .95). Stiffness and failure load in the prosthesis group was significantly higher compared to all other groups (P ≤ .04) and in addition, it was significantly lower in the fixation group compared to the intact group (P = .03), with no further detected significant differences among the groups (P ≥ .72). Absorbed energy to failure in the prosthesis group was significantly more compared to both radial head and fixation groups (P ≤ .04) but not vs. the intact group. Failure deformation at the osteotomy site was not significantly different among the groups (P = .26). CONCLUSIONS: Coronoid process replacement using an anatomically shaped, individually designed 3D printed prosthesis with curved cemented IM stem seems to be an effective method to restore the coronoid buttress function under axial loading. This method provides superior fixation strength over both radial head grafted reconstruction and screw fixation.


Asunto(s)
Articulación del Codo , Fracturas del Radio , Humanos , Articulación del Codo/cirugía , Implantación de Prótesis , Cúbito/cirugía , Fijación Interna de Fracturas/métodos , Tornillos Óseos , Impresión Tridimensional , Fracturas del Radio/diagnóstico por imagen , Fracturas del Radio/cirugía , Fenómenos Biomecánicos
4.
Arch Orthop Trauma Surg ; 143(8): 4679-4688, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36622424

RESUMEN

INTRODUCTION: After conventional surgical refixation of the hamstrings after proximal hamstring rupture, patients frequently experience pain while sitting and deficits in hamstring muscle strength of the operated side. To improve these outcomes, we have modified the surgical anchor placement and have carried out a thorough follow-up examination. MATERIALS AND METHODS: Thirteen older patients (8 female, 5 males) with a median age of 64.2 (range, 52.1-80.4) years were surgically treated for acute proximal hamstring rupture using modified anchor placement and participated in a follow-up assessment at a median of 46.2 (11.2-75.0) months after surgery. Patients completed the Perth Hamstring Assessment Tool (PHAT), quality of life questionnaire (EQ-5D-5L) and the Lower Extremity Functional Scale (LEFS), and rated their satisfaction level on a scale from 0 to 100%. Local tenderness on the ischial tuberosity and maximum passive hip flexion were measured on both limbs. Maximum isokinetic knee flexor muscle strength was measured bilaterally using a dynamometer. RESULTS: The median (range) PHAT, EQ-5D-5L and LEFS score were 78.8/100 (54.6-99.8), 0.94/1 (0.83-1) and 88.75/100 (61.25-100). The median satisfaction was 100% (90-100%). Only one patient felt discomfort when the ischial tuberosity was palpated. Neither maximum passive hip flexion nor maximum isokinetic flexor muscle strength differed between the operated and non-operated side (P > 0.58). Clinical scores did not correlate with the leg symmetry index of knee flexor muscle strength (Spearman's rho < 0.448, P > 0.125). There were no tendon re-ruptures, or postoperative sciatic radiculopathy, at the time of follow-up. CONCLUSIONS: The modified extra-anatomical anchor placement resulted in good clinical and functional outcome of surgical repair of acute proximal hamstring rupture. Especially the absence of postoperative pain while sitting and the comparable muscle strength to the contralateral side is promising. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT04867746, registered.


Asunto(s)
Músculos Isquiosurales , Tendones Isquiotibiales , Traumatismos de los Tendones , Anciano , Niño , Preescolar , Femenino , Humanos , Masculino , Músculos Isquiosurales/cirugía , Tendones Isquiotibiales/cirugía , Fuerza Muscular , Satisfacción del Paciente , Calidad de Vida , Recuperación de la Función , Rotura/cirugía , Traumatismos de los Tendones/cirugía
5.
Arch Orthop Trauma Surg ; 143(7): 4155-4164, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36460761

RESUMEN

INTRODUCTION: Osteosynthesis of femoral neck fractures (FNFs) is an important treatment option, especially for younger patients. We aimed to assess the rate of early implant-related complications in FNF osteosynthesis using the Femoral Neck System (FNS). PATIENTS AND METHODS: Consecutive patients diagnosed with displaced or nondisplaced FNFs were treated with FNS in this prospective, observational, multicenter investigation. Patients were followed up for minimally 3 months and up to 12 months if radiologic bone union and no pain was not achieved beforehand. Predefined treatment-related adverse events (AEs, defined as implant failure, loss of reduction, iatrogenic fractures, deep infection, and surgical revision), radiologic bone union, and patient-reported Harris hip score (HHS) and EQ-5D-5L index score were assessed. RESULTS: One hundred and twenty-five patients were included in the study. Thirty-eight (30.4%) fractures were displaced (Garden III and IV), and 37 (29.6%) were vertical fractures (Pauwels type III). Predefined treatment-related AE rate at 3 months was 8 patients, 6.4% (95% CI, 2.8-12.2), and at 12 months, 11 patients, 8.8% (95% CI, 4.5-15.2). Cumulative incidences of bone union were 68% at 3 months, 90% at 6 months, and 98% at 12 months. The mean changes of HHS and EQ-5D-5L index score between preinjury and at 12 months were -7.5 (95% CI, [ - 21.1] to [6.2]) and - 0.03 (95% CI, [ - 0.21] to [0.15]), respectively; neither were statistically significant. CONCLUSION: The current study on osteosynthesis of FNFs with the FNS resulted in treatment-related complication rates of 6.4% (95% CI, 2.8-12.2) at 3 months and 8.8% (95% CI, 4.5-15.2) at 12 months. On average, patients returned to preinjury function and quality of life. The current study may also indicate that the conventional wisdom of treating stable FNF in patients aged between 60 and 80 years with osteosynthesis may need to be reconsidered. REGISTRATION: The study is registered with ClinicalTrials.gov (registration number: NCT02422355).


Asunto(s)
Fracturas del Cuello Femoral , Cuello Femoral , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Calidad de Vida , Estudios Prospectivos , Fracturas del Cuello Femoral/cirugía , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Fijación Interna de Fracturas/métodos , Resultado del Tratamiento , Estudios Retrospectivos
6.
Medicina (Kaunas) ; 59(10)2023 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-37893539

RESUMEN

Background and Objectives: Implantation of a short femoral stem in revision total hip arthroplasty (rTHA) could reduce the perioperative time, soft tissue damage, and preserve the bone stock of the proximal femur. The objective of this study was to describe the clinical and radiographic outcomes after the use of short stems in rTHA with a follow-up of 1 to 5 years. Materials and Methods: This retrospective, single center, and observational study analyzed the data of 31 patients (12 female, 19 male) with a median (interquartile range) age of 68.2 years (61.2-78.4) and BMI of 26.7 kg/m2 (24.6-29.4) who received an uncemented short femoral stem in rTHA between 2015 and 2020. Clinical outcomes were extracted from medical reports and assessed using the modified Harris Hip Score (mHHS), the numerical rating scale (NRS) for pain and satisfaction, and the UCLA Physical Activity Score. Radiographs were analyzed for stem subsidence, fixation, and bone parameters. The Wilcoxon test was used for pre-post rTHA differences (p < 0.05); clinical relevance was interpreted based on effect sizes according to Cohen's d. Results: All the clinical outcome measures improved significantly (p ≤ 0.001) at follow-up compared to preoperative status, with large effect sizes (Cohen's d) ranging from 2.8 to 1.7. At the last follow-up, the median (interquartile) mHHS was 80.9 (58.6-93.5). Stem fixation was stable in all cases. Complications included stem subsidence of 3 mm (n = 1) and 10 mm (n = 1), heterotopic ossification Brooker stage III (n = 2), intraoperative femur perforation (n = 1), periprosthetic fracture Vancouver type A (n = 1), and dislocation (n = 2). Conclusions: The good clinical results in our selective study population of patients with mild to moderate bone deficiency, supported by large effect sizes, together with a complication rate within the normal range, support the consideration of short stems as a surgical option after a thorough preoperative analysis.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Masculino , Femenino , Anciano , Artroplastia de Reemplazo de Cadera/efectos adversos , Estudios Retrospectivos , Fémur , Reoperación/métodos , Resultado del Tratamiento
7.
Medicina (Kaunas) ; 59(9)2023 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-37763723

RESUMEN

Background and Objectives: Unstable proximal humerus fractures (PHFs) with metaphyseal defects-weakening the osteosynthesis construct-are challenging to treat. A new augmentation technique of plated complex PHFs with metaphyseal defects was recently introduced in the clinical practice. This biomechanical study aimed to analyze the stability of plated unstable PHFs augmented via implementation of this technique versus no augmentation. Materials and Methods: Three-part AO/OTA 11-B1.1 unstable PHFs with metaphyseal defects were created in sixteen paired human cadaveric humeri (average donor age 76 years, range 66-92 years), pairwise assigned to two groups for locked plate fixation with identical implant configuration. In one of the groups, six-milliliter polymethylmethacrylate bone cement with medium viscosity (seven minutes after mixing) was placed manually through the lateral window in the defect of the humerus head after its anatomical reduction to the shaft and prior to the anatomical reduction of the greater tuberosity fragment. All specimens were tested biomechanically in a 25° adduction, applying progressively increasing cyclic loading at 2 Hz until failure. Interfragmentary movements were monitored by motion tracking and X-ray imaging. Results: Initial stiffness was not significantly different between the groups, p = 0.467. Varus deformation of the humerus head fragment, fracture displacement at the medial humerus head aspect, and proximal screw migration and cut-out were significantly smaller in the augmented group after 2000, 4000, 6000, 8000 and 10,000 cycles, p ≤ 0.019. Cycles to 5° varus deformation of the humerus head fragment-set as a clinically relevant failure criterion-and failure load were significantly higher in the augmented group, p = 0.018. Conclusions: From a biomechanical standpoint, augmentation with polymethylmethacrylate bone cement placed in the metaphyseal humerus head defect of plated unstable PHFs considerably enhances fixation stability and can reduce the risk of postoperative complications.

8.
BMC Musculoskelet Disord ; 23(1): 35, 2022 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-34986819

RESUMEN

Complex intraarticular distal radius fractures (DRFs), commonly managed with volar locking plates, are challenging. Combined volar and dorsal plating is frequently applied for treatment, however, biomechanical investigations are scant. The aim of this biomechanical study was to investigate volar plating versus double plating in DRFs with different degrees of lunate facet comminution.Thirty artificial radii with simulated AO/OTA 23-C2.1 and C3.1 DRFs, including dorsal defect and lunate facet comminution, were assigned to 3 groups: Group 1 with two equally-sized lunate facet fragments; Group 2 with small dorsal and large volar fragment; Group 3 with three equally-sized fragments. The specimens underwent volar and double locked plating and non-destructive ramped loading in 0° neutral position, 40° flexion and 40° extension.In each tested position, stiffness: (1) did not significantly differ among groups with same fixation method (p ≥ 0.15); (2) increased significantly after supplemental dorsal plating in Group 2 and Group 3 (p ≤ 0.02).Interfragmentary displacements between styloid process and lunate facet in neutral position were below 0.5 mm, being not significantly different among groups and plating techniques (p ≥ 0.63).Following volar plating, angular displacement of the lunate facet to radius shaft was significantly lower in Group 1 versus both Group 2 and Group 3 (p < 0.01). It decreased significantly after supplemental dorsal plating in Group 2 and Group 3 (p < 0.01), but not in Group 1 (p ≥ 0.13), and did not differ significantly among the three groups after double plating (p ≥ 0.74).Comminution of the lunate facet within its dorsal third significantly affected the biomechanical outcomes related to complex intraarticular DRFs treated with volar and double locked plates.Double plating demonstrates superior stability versus volar plating only for lunate facet comminution within its dorsal third. In contrast, volar plating could achieve stability comparable with double plating when the dorsal third of the lunate facet is not separated by the fracture pattern. Both fixation methods indicated achievable absolute stability between the articular fragments.


Asunto(s)
Fracturas Conminutas , Hueso Semilunar , Fracturas del Radio , Fenómenos Biomecánicos , Placas Óseas , Fijación Interna de Fracturas , Humanos , Fracturas del Radio/diagnóstico por imagen , Fracturas del Radio/cirugía
9.
Arch Orthop Trauma Surg ; 142(12): 3787-3796, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34748055

RESUMEN

BACKGROUND: Recently, two novel concepts for intramedullary nailing of trochanteric fractures using a helical blade or interlocking dual screws have demonstrated advantages as compared to standard single-screw systems. However, these two concepts have not been subjected to a direct biomechanical comparison so far. The aims of this study were to investigate in a human cadaveric model with low bone quality (1) the biomechanical competence of nailing with the use of a helical blade versus interlocking screws, and (2) the effect of cement augmentation on the fixation strength of the helical blade. METHODS: Twelve osteoporotic and osteopenic human cadaveric femoral pairs were assigned for pairwise implantation using either a short TFN-ADVANCED Proximal Femoral Nailing System (TFNA) with a helical blade head element or a short TRIGEN INTERTAN Intertrochanteric Antegrade Nail (InterTAN) with interlocking screws. Six osteoporotic femora, implanted with TFNA, were augmented with bone cement. Four groups were created: group 1 (TFNA) paired with group 2 (InterTAN), both consisting of osteopenic specimens, and group 3 (TFNA augmented) paired with group 4 (InterTAN), both consisting of osteoporotic specimens. An unstable trochanteric AO/OTA 31-A2.2 fracture was simulated and all specimens were tested until failure under progressively increasing cyclic loading. RESULTS: Stiffness in group 3 was significantly higher versus group 4, p = 0.03. Varus (°) and femoral head rotation around the femoral neck axis (°) after 10,000 cycles were 1.9 ± 1.0/0.3 ± 0.2 in group 1, 2.2 ± 0.7/0.7 ± 0.4 in group 2, 1.5 ± 1.3/0.3 ± 0.2 in group 3 and 3.5 ± 2.8/0.9 ± 0.6 in group 4, being significantly different between groups 3 and 4, p = 0.04. Cycles to failure and failure load (N) at 5° varus or 10° femoral head rotation around the neck axis in groups 1-4 were 21,428 ± 6020/1571.4 ± 301.0, 20,611 ± 7453/1530.6 ± 372.7, 21,739 ± 4248/1587.0 ± 212.4 and 18,622 ± 6733/1431.1 ± 336.7, being significantly different between groups 3 and 4, p = 0.04. CONCLUSIONS: Nailing of trochanteric femoral fractures with use of helical blades is comparable to interlocking dual screws fixation in femoral head fragments with low bone quality. Bone cement augmentation of helical blades provides significantly greater fixation strength compared to interlocking screws constructs.


Asunto(s)
Fijación Intramedular de Fracturas , Fracturas de Cadera , Humanos , Tornillos Óseos , Cementos para Huesos , Uñas , Cadáver , Fracturas de Cadera/cirugía , Clavos Ortopédicos , Fenómenos Biomecánicos
10.
Medicina (Kaunas) ; 58(10)2022 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-36295586

RESUMEN

Background and Objectives: The treatment of proximal humerus fractures in elderly patients is challenging, with reported high complication rates mostly related to implant failure involving screw cut-out and penetration. Metaphyseal defects are common in osteoporotic bone and weaken the osteosynthesis construct. A novel technique for augmentation with polymethylmethacrylate (PMMA) bone cement was developed for the treatment of patients in advanced age with complex proximal humerus fractures and metaphyseal voids, whereby the cement was allowed to partially cure for 5-7 min after mixing to achieve medium viscosity, and then it was manually placed into the defect through the traumatic lateral window with a volume of 4-6 mL per patient. The aim of this retrospective clinical study was to assess this technique versus autologous bone graft augmentation and no augmentation. Materials and Methods: The outcomes of 120 patients with plated Neer three- and four-part fractures, assigned to groups of 63 cases with no augmentation, 28 with bone graft augmentation and 29 with cement augmentation, were assessed in this study. DASH, CS, pain scores and range of motion were analyzed at 3, 6 and 12 months. Statistical analysis was performed with factors for treatment and age groups, Neer fracture types and follow-up periods, and with the consideration of age as a covariate. Results: DASH and CS improved following cement augmentation at three and six months compared to bone grafting, being significant when correcting for age as a covariate (p ≤ 0.007). While the age group had a significant effect on both these scores with worsened values at a higher age for non-augmented and grafted patients (p ≤ 0.044), this was not the case for cement augmented patients (p ≥ 0.128). Cement augmentation demonstrated good clinical results at 12 months with a mean DASH of 10.21 and mean CS percentage of 84.83% versus the contralateral side, not being significantly different among the techniques (p ≥ 0.372), despite the cement augmented group representing the older population with more four-part fractures. There were no concerning adverse events specifically related to the novel technique. Conclusions: This study has detailed a novel technique for the treatment of metaphyseal defects with PMMA cement augmentation in elderly patients with complex proximal humerus fractures and follow-up to one year, whereby the cement was allowed to partially cure to achieve medium viscosity, and then it was manually placed into the defect through the traumatic lateral window. The results demonstrate clinically equivalent short-term results to 6 months compared to augmentation with bone graft or no augmentation-despite the patient group being older and with a higher rate of more severe fracture patterns. The technique appears to be safe with no specifically related adverse events and can be added in the surgeon's armamentarium for the treatment of these difficult to manage fractures.


Asunto(s)
Cementos para Huesos , Fracturas del Hombro , Humanos , Anciano , Cementos para Huesos/uso terapéutico , Polimetil Metacrilato/uso terapéutico , Estudios Retrospectivos , Fracturas del Hombro/cirugía , Fracturas del Hombro/tratamiento farmacológico , Placas Óseas , Fijación Interna de Fracturas , Húmero/cirugía
11.
Sensors (Basel) ; 21(16)2021 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-34450828

RESUMEN

There is a great need for quantitative outcomes reflecting the functional status in patients with knee or hip osteoarthritis (OA) to advance the development and investigation of interventions for OA. The purpose of this study was to determine if gait kinematics specific to the disease-i.e., knee versus hip OA-can be identified using wearable sensors and statistical parametric mapping (SPM) and whether disease-related gait deviations are associated with patient reported outcome measures. 113 participants (N = 29 unilateral knee OA; N = 30 unilateral hip OA; N = 54 age-matched asymptomatic persons) completed gait analysis with wearable sensors and the Knee/Hip Osteoarthritis Outcome Score (KOOS/HOOS). Data were analyzed using SPM. Knee and hip kinematics differed between patients with knee OA and patients with hip OA (up to 14°, p < 0.001 for knee and 8°, p = 0.003 for hip kinematics), and differences from controls were more pronounced in the affected than unaffected leg of patients. The observed deviations in ankle, knee and hip kinematic trajectories from controls were associated with KOOS/HOOS in both groups. Capturing gait kinematics using wearables has a large potential for application as outcome in clinical trials and for monitoring treatment success in patients with knee or hip OA and in large cohorts representing a major advancement in research on musculoskeletal diseases.


Asunto(s)
Osteoartritis de la Cadera , Osteoartritis de la Rodilla , Dispositivos Electrónicos Vestibles , Fenómenos Biomecánicos , Marcha , Humanos , Articulación de la Rodilla , Osteoartritis de la Cadera/diagnóstico , Osteoartritis de la Rodilla/diagnóstico , Medición de Resultados Informados por el Paciente
12.
Medicina (Kaunas) ; 57(8)2021 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-34440969

RESUMEN

Intertrochanteric femur fractures are common in older patients and often have a significant impact on disability. The treatment aims to achieve a rapid return to the prior functional level with a low rate of complications and mortality. Surgical management by internal fixation is the mainstay of treatment for most of these fractures. Even when treated with intramedullary nails, the overall complication rates are high, especially for unstable or highly comminuted fractures or in the presence of poor bone quality. Hip arthroplasty is an alternative in older patients with intertrochanteric femur fractures at high risk of fixation failure or with concomitant intraarticular pathologies. Especially patients whose condition precludes prolonged bedrest and who are at risk of significant deterioration if their locomotor function cannot be restored rapidly are likely to benefit from hip arthroplasty. The choice of the surgical technique mainly depends on the surgeon's preferences and the fracture characteristics. Bipolar hemiarthroplasty is the most common type of prosthesis used with primary or revision femoral stems. Compared with intramedullary nails, hip arthroplasty has a better early functional outcome and lower rates of surgical complications as well as reoperations. However, the functional outcome and the mortality rate in the longer term tend to favor intramedullary nails, even though the results are inconsistent, and a statistically significant difference cannot always be obtained. Currently, there are no guidelines that define the role of hip arthroplasty in the treatment of intertrochanteric femur fractures in older patients. The literature only offers an overview of the possibilities of the usage of hip arthroplasty, but methodological limitations are common, and evidence levels are low. Further studies are needed to identify the intertrochanteric fractures that are at high risk of internal fixation failure, the characteristics that determine which patients may benefit most from hip arthroplasty, and the optimal surgical technique.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Anciano , Artroplastia de Reemplazo de Cadera/efectos adversos , Clavos Ortopédicos , Fémur , Fijación Interna de Fracturas , Articulación de la Cadera , Humanos , Resultado del Tratamiento
13.
Medicina (Kaunas) ; 57(8)2021 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-34440996

RESUMEN

Background and Objectives: Femoral neck fractures are common and constitute one of the largest healthcare burdens of the modern age. Fractures within the joint capsule (intracapsular) provide a specific surgical challenge due to the difficulty in predicting rates of bony union and whether the blood supply to the femoral head has been disrupted in a way that would lead to avascular necrosis. Most femoral neck fractures are treated surgically, aiming to maintain mobility, whilst reducing pain and complications associated with prolonged bedrest. Materials and Methods: We performed a narrative review of intracapsular hip fracture management, highlighting the latest advancements in fixation techniques, generating an evidence-based algorithm for their management. Results: Multiple different fracture configurations are encountered within the category of intracapsular hip fractures, with each pattern having different optimal surgical strategies. Additionally, these injuries typically occur in patients where further procedures due to operative complications are associated with a considerable increase in mortality, highlighting the need for choosing the correct index operation. Conclusions: Factors such as pathological causes for the fracture, pre-existing symptomatic osteoarthritis, patient's physiological age and fracture displacement all need to be considered when choosing optimal management.


Asunto(s)
Fracturas del Cuello Femoral , Algoritmos , Fracturas del Cuello Femoral/cirugía , Cabeza Femoral , Fijación Interna de Fracturas , Humanos , Resultado del Tratamiento
14.
Arch Orthop Trauma Surg ; 140(10): 1381-1394, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32086558

RESUMEN

INTRODUCTION: Hip arthroplasty (HA) is commonly performed to treat various hip pathologies. Its volume is expected to rise further due to the increasing age of the population. Complication rates are low; however, periprosthetic femoral fractures (PFF) are a rare, albeit serious, complication with substantial economic impact. While current guidelines propose revision with long-stemmed prostheses for all Vancouver B2 and B3 PFF, some recent research papers suggest that open reduction with internal fixation (ORIF) could lead to an equivalent outcome. Our aim was to summarize the evidence, elucidating under which circumstances ORIF leads to a favorable outcome after B2 and B3 PFF compared with revision surgery. MATERIALS AND METHODS: A systematic literature search was performed to identify studies on patients treated with ORIF and with stem revision after B2 and/or B3 fractures. Extracted information included initial pathology, stem fixation mechanism, bone quality and stem stability at the time of PFF, clinical outcomes, and mortality. Results of individual studies were summarized in a table in lieu of a quantitative data synthesis due to a lack of standardized information. RESULTS: We identified 14 original research articles including both patients treated with ORIF and with stem revision after B2 and/or B3 PFF. Five studies included statistical comparisons, all were in favor of ORIF or indeterminate. The common lack of rigorous statistical analyses and significant methodological weaknesses made identification of outcome predictors impossible. CONCLUSION: The choice of treatment modality for PFF depends on fracture, implant, and bone characteristics. Recent data show that successful outcome can be achieved without revising loose stems. ORIF may be a viable option if bone stock is adequate around uncemented or tapered polished stems with an intact cement mantle and the fracture geometry allows stable anatomic reconstruction. Conceptional considerations support this idea, but more data are needed to identify outcome predictors.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Fémur , Fijación Interna de Fracturas , Fracturas Periprotésicas/cirugía , Reoperación , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Fracturas del Fémur/etiología , Fracturas del Fémur/cirugía , Prótesis de Cadera/efectos adversos , Humanos , Complicaciones Posoperatorias/cirugía
15.
Arch Orthop Trauma Surg ; 137(6): 779-788, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28391429

RESUMEN

INTRODUCTION: Osteosynthesis of femoral neck fractures is related up to 46% rate of complications. The novel method of biplane double-supported screw fixation (BDSF; Filipov's method) offers better stability using three medially diverging cannulated screws with two of them buttressed on the calcar. Biomechanically, the most effective component is the distal screw placed at steeper angle and supported on a large area along the distal and posterior cortex of the femoral neck following its spiral anterior curve. Thereby, BDSF achieves the strongest possible distal-posterior cortical support for the fixation construct, which allows for immediate full weight-bearing. The aim of this study was to evaluate the outcomes from the first 5-year period of BDSF clinical application. MATERIALS AND METHODS: Subject of this retrospective study were 207 patients with displaced Garden III-IV femoral neck fractures treated with BDSF. Three 7.3-mm cannulated screws were laid in two medially diverging oblique planes. The distal and the middle screws were supported on the calcar. The distal screw had additional support on the posterior neck cortex. RESULTS: The outcomes in 207 patients were analysed in 29.6 ± 16.8 months follow-up. Bone union occurred in 96.6% of the cases (males 97.6%, females 96.4%, P = 0.99). Rate of nonunion was 3.4%, including fixation failure (2.4%), pseudoarthrosis (0.5%) and nonunion with AVN (0.5%). Rate of AVN was 12.1% (males 4.8%, females 13.9%, P = 0.12). Modified Harris hip score was 86.2 ± 18.9 (range 10-100), with no significant difference between genders, P = 0.07. Older patients were admitted with significantly more comorbidities (P = 0.001), and on follow-up they were significantly less mobile (P = 0.005) and had significantly more difficulties to put socks and shoes on (P < 0.001). CONCLUSIONS: By providing additional cortical support, the novel BDSF method enhances femoral neck fracture fixation strength.


Asunto(s)
Placas Óseas , Tornillos Óseos , Fracturas del Cuello Femoral/cirugía , Fijación Interna de Fracturas/métodos , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Insuficiencia del Tratamiento
16.
BMC Musculoskelet Disord ; 17(1): 395, 2016 09 17.
Artículo en Inglés | MEDLINE | ID: mdl-27640188

RESUMEN

BACKGROUND: Cemented stems show good long-term results and the survival of new implants can be predicted by their early subsidence. With EBRA-FCA (Femoral Component Analysis using Einzel-Bild-Röntgen-Analyse) early subsidence as an early indicator for later aseptic loosening can be analysed. For the cemented TwinSys stem mid- and long-term data is only avalible from the New Zeeland Arthroplasty register, thus close monitoring of this implant system is still mandatory. METHODS: We conducted a 2 year follow up of 100 consecutive hybrid THA (Total hip arthroplasty) of a series of 285 primary THA operated between Jan 2009 und Oct 2010. These 100 received a polished, cemented collarless straight stem (twinSys®, Mathys AG® Bettlach, Switzerland) with an uncemented monobloc pressfit cup (RM pressfit®, Mathys AG® Bettlach, Switzerland). The other patients were treated with the uncemented version of this stem and the same cup. Clinical (Harris Hip Score) and radiological (ap and axial x-rays, cementing quality according to Barrack, alignment) outcomes besides an EBRA-FCA subsidence analysis were performed. RESULTS: Median age at operation was 78 (68 to 93) years. 5 patients died in the course of follow-up unrelated to surgery. The KM (Kaplan-Meier) survival at 2 years for the endpoint reoperation for any reason was 94.9 (95 % confidence interval 90.6-100 %). Survival for the endpoint aseptic loosening at 2 years was 100 %. The HHS (Harris Hip Score) improved from 56 (14-86) preoperatively to 95 (60-100) 2 years after the operation. Cementing results were judged 47 % Grade A, 45 % Grade B and 7 % Grade C. Osteolysis was found in 2 stems without clinical symptoms or correlation to subsidence or cementing quality. The EBRA-FCA analysis showed an average subsidence of -0.30 mm (95 % CI -0.5 mm to -0.1 mm). 11 patients showed a subsidence of more than 1 mm. In this group one patient showed a subsidence of 1.5 mm and one of 3.1 mm without further radiological changes. CONCLUSIONS: The twinSys stem showed excellent clinical and radiologic short term results at 2 years follow-up and seems to be a reliable implant.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Prótesis de Cadera/estadística & datos numéricos , Anciano , Anciano de 80 o más Años , Cementos para Huesos , Femenino , Articulación de la Cadera/diagnóstico por imagen , Humanos , Masculino , Estudios Prospectivos , Diseño de Prótesis , Resultado del Tratamiento
17.
Arch Orthop Trauma Surg ; 136(4): 553-61, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26781127

RESUMEN

INTRODUCTION: A systematic literature review on periprosthetic/interprosthetic fracture fixation after hip arthroplasties was performed to summarize available clinical data. Operation techniques and implants used were evaluated as possible risk factors for outcomes. MATERIALS AND METHODS: MEDLINE and Cochrane databases were searched. Articles describing patients with postoperative periprosthetic femur fractures sustained around a hip arthroplasty and with interprosthetic fractures treated with plates, nails, screws and/or cerclage were included. Considered articles were from 2000 or newer. Eligible abstracts were screened by two independent persons and discrepancies were resolved by consensus. Absolute numbers of complications and/or reoperation events along with their corresponding rates were calculated according to operation technique and type of implant. Relative risks of having a complication and/or a reoperation according to the operation technique and the type of implant used were estimated. RESULTS: Available data from 49 prospective and retrospective studies were analyzed. Of 1574 fractures, 81.7 % were treated with plating. For 83.0 % of all fractures, an open approach was applied. The overall complication rate was 14.3 %. Fixation failure and nonunion were most often reported (fixation failure: 4.4 %; nonunion: 3.9 %). Nonunion and refracture occurred more often after open approaches than after minimal invasive osteosynthesis (nonunion: 4.5 vs. 0.0 %, p = 0.001; refracture: 3.8 vs. 0.6 %. p = 0.024). The relative risk for nonunion was 11.9 (95 % CI 4.5-31.5) times higher (p < 0.0001) for non-locking plates (13.0 %) than for locking plates (1.1 %). CONCLUSIONS: The clinical evidence of published studies dealing with periprosthetic/interprosthetic fractures after hip arthroplasty is generally low. This literature search suggested higher rates of nonunion and refracture after an open approach and a higher risk of nonunion for non-locking plates compared to locking plates. Based on the available clinical evidence, no treatment recommendations can be given.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Fijación Interna de Fracturas/métodos , Fracturas de Cadera/cirugía , Prótesis de Cadera/efectos adversos , Fracturas Periprotésicas/cirugía , Artroplastia de Reemplazo de Cadera/instrumentación , Fijación Interna de Fracturas/instrumentación , Fracturas de Cadera/etiología , Humanos , Fracturas Periprotésicas/etiología , Resultado del Tratamiento
18.
Arch Orthop Trauma Surg ; 136(2): 277-84, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26739137

RESUMEN

INTRODUCTION: Uncemented short, curved femoral stems may help save proximal bone stock during total hip arthroplasty (THA) and facilitate insertion in minimal invasive surgery. The aim of this 2 year, prospective, single-center study was to examine the stability and migration of the Fitmore (®) stem in THA using model-based radiostereometric analysis (RSA), and thus predict the implant's long-term survival. In addition, we evaluated the stem's clinical performance using standard clinical measures. PATIENTS AND METHODS: We conducted a prospective cohort study of 34 THA patients who received the short Fitmore Hip Stem (Zimmer, Winterthur, Switzerland). At 3, 6, 12 and 24 months postoperatively, the patients underwent clinical evaluation and radiostereometric analysis (RSA) to measure stem migration. RESULTS: RSA analysis revealed a mean subsidence of -0.39 mm (95 % CI -0.60 to -0.18) at 3 months with no further migration after 2 years. Mean internal rotation along the longitudinal axis was 1.09° (95 % CI 0.52-1.66) at 2 years, versus 0.85° (95 % CI 0.44-1.26) at 3 months. The Harris hip score improved from 60 (range 30-80) preoperatively to 99 (range 83-100) after 2 years. Three patients underwent revision due to deep infection, non-specific thigh pain and aseptic loosening in one case. CONCLUSION: We conclude that the Fitmore Hip Stem stabilizes after 3 months and achieves good short-term clinical results in most cases.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Articulación de la Cadera/diagnóstico por imagen , Prótesis de Cadera , Análisis Radioestereométrico , Adulto , Anciano , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Evaluación del Resultado de la Atención al Paciente , Diseño de Prótesis , Adulto Joven
19.
J Arthroplasty ; 29(6): 1308-12, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24439999

RESUMEN

Periprosthetic femoral fractures (PFF) are a serious complication after total hip arthroplasty. Plate fixation with screws perforating the cement mantle is a common treatment option. The study objective was to investigate hip stem stability and cement mantle integrity under dynamic loading. A cemented hip stem was implanted in 17 composite femur models. Nine bone models were osteotomised just distal to the stem and fixed with a polyaxial locking plate the other eight constructs served as the control group. All specimens were tested in a bi-axial material testing machine (100000 cycles). There were no statistically significant differences in axial nor in medial (varus) stem migration. No cement cracks were detected in both groups. Plate fixation of a PFF with a stable, cemented prosthesis did not lead to cement mantle failure in this in vitro study.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Placas Óseas/efectos adversos , Fracturas del Fémur/cirugía , Fracturas Periprotésicas/cirugía , Artroplastia de Reemplazo de Cadera/instrumentación , Fenómenos Biomecánicos , Cementos para Huesos , Cementación , Fracturas del Fémur/etiología , Fémur/cirugía , Prótesis de Cadera/efectos adversos , Humanos , Modelos Biológicos , Osteotomía , Fracturas Periprotésicas/etiología , Falla de Prótesis
20.
Praxis (Bern 1994) ; 113(1): 15-19, 2024 Jan.
Artículo en Alemán | MEDLINE | ID: mdl-38381105

RESUMEN

INTRODUCTION: Osteoanabolic osteoporosis drugs have become better available. The osteoanabolic therapeutic principle has a stronger, faster-onset fracture-reducing effect than the antiresorptive preparations. It has also been newly recognized that the significance of a first fragility fracture as a risk factor is time-dependent: the less time that has elapsed since the first fracture, the higher the resulting re-fracture risk. Patients older than 65 years whose index fragility fracture occurred less than two years before are therefore grouped in a separate "Imminent Fracture Risk" category. These innovations were implemented by updating the osteoporosis therapy guideline. According to this guideline, patients in the "Imminent Fracture Risk" category should be offered osteoporosis therapy as soon as possible, in order to avoid as many fractures as possible. We are critical of an overly strict implementation of this algorithm in very old fracture patients. Our own data indicate that more than 30 % of this subpopulation do not experience the effect of a newly started osteoporosis therapy. We advocate a clinically based indication for osteoporosis therapy. For this, we propose a "Question Surprise" modified for osteological purposes. "Would I be surprised if I had to treat the same patient for a fracture again in a year?" If the question is answered with "No," then that patient could be a candidate for specific osteoporosis treatment.


Asunto(s)
Fracturas Óseas , Osteoporosis , Humanos , Osteoporosis/tratamiento farmacológico , Algoritmos , Pacientes , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda