Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
País como asunto
Tipo del documento
Publication year range
1.
Heart Lung Circ ; 33(2): 222-229, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38245394

RESUMEN

AIM: Transcatheter mitral valve-in-valve (TMViV) replacement for degenerated surgically implanted bioprosthetic valves has been described by both transseptal and transapical approaches. The balloon-expandable Myval transcatheter valve (Meril Life Sciences, Vapi, India) is commonly used for transcatheter valve-in-valve procedures in India. This study aimed to report in-hospital, 30-day, and 1-year outcomes of Myval patients who underwent TMViV in a single tertiary care centre in India. METHODS: Symptomatic patients with surgical bioprosthetic mitral valve failure with New York Heart Association (NYHA) class III-IV symptoms, despite optimal medical therapy and high or very high risk for redo surgery, were assigned to TMViV following heart team discussions. Data were retrospectively collected and outcomes assessed. RESULTS: Twenty patients were treated, with mean age 64.4 years, 60% were female, and mean Society of Thoracic Surgeons (STS) predicted risk of operative mortality score was 8.1. The failure mechanism was combined stenosis and regurgitation in 60% of patients. Technical success was achieved in 100% of patients. The mean postprocedure and 30-day gradients were 4.6±2.7 and 6.3±2.1, respectively. None of them had significant valvular or paravalvular leaks or left ventricular outflow tract obstruction. All-cause mortality at 1 year was 10%, and all survivors were in New York Heart Association (NYHA) class I or II. CONCLUSION: TMViV replacement with a Meril Myval can be safely performed with high technical success, and low 30-day and 1-year mortality.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Femenino , Persona de Mediana Edad , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estudios Retrospectivos , Resultado del Tratamiento , Cateterismo Cardíaco/métodos , Diseño de Prótesis
2.
Cardiovasc Revasc Med ; 63: 1-7, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38423848

RESUMEN

PURPOSE: To evaluate the safety and effectiveness of the novel, next-generation Myval Octacor - Transcatheter Heart Valve (THV) in patients with severe, symptomatic, native aortic stenosis (AS). METHODS: This multicenter, real-world observational registry included 123 patients with severe symptomatic AS, across 16 Indian centers who underwent treatment with the novel Myval Octacor THV. Study endpoints included all-cause mortality, all stroke, acute kidney injury (AKI), major vascular complications, moderate or severe paravalvular leakage (PVL) and new permanent pacemaker implantation (PPI) until 30 days follow-up. RESULTS: Of the 123 patients (average age 70.07 ± 8.33 years), 37.4 % (n = 46) were female and 39.84 % presented with bicuspid valves. The technical success rate of the procedure was 100 % and the device success rate at 30 days was 98.4 %. At 30 days (n = 123) after the procedure, the overall mortality was 1.6 %. AKI occurred in 1.6 % of patients and there was no incidence of stroke, bleeding (types 3 and 4), and major vascular complications. In an analysis of 31 patients whose echocardiographic parameters were available across all timepoints, there were significant improvements in the mean pressure gradient (54.31 ± 18.19 mmHg vs. 10.42 ± 4.24 mmHg; p < 0.0001) and effective orifice area (0.66 ± 0.21 cm2 vs. 1.80 ± 0.44 cm2; p < 0.0001) from baseline to the 30-day follow-up. None of the patients experienced severe PVL, while moderate PVL was observed in two patients (1.6 %). CONCLUSIONS: Early outcomes of the next-generation, novel Myval Octacor THV proved its safety and effectiveness in the treatment of severe AS.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Sistema de Registros , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Masculino , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Resultado del Tratamiento , Anciano , India , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Factores de Tiempo , Anciano de 80 o más Años , Persona de Mediana Edad , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Factores de Riesgo , Recuperación de la Función , Complicaciones Posoperatorias , Estudios Retrospectivos , Hemodinámica
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda